Description | Shipped From Abroad
All of the advantages and performance of the cutting-edge Dolphin TCD technology for measurements of cerebral blood flow velocities are implemented in the smart and compact Dolphin/IQ Transcranial Doppler module.
Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| In stock
Four sizes from small adult to extra large adult. A range of color-coded economy anesthetic face masks for single patient use to prevent the possibility of cross infection.
Delivery & Availability:
Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | | Shipped from Abroad
- Compact design
- save space in O.R or Laboratory Room
- High quality & Durability design
- Easy operation & easy maintenance
- New integrated respiratory circuit available with own patent
- LED Ventilator inside & One standard ZF-1000 precise vaporizer
- Optional: Two precise ZF-1000 vaporizers
Delivery & Availability:
Typically 21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | In Stock
Sirius-XL Eclipse blades feature a flexible tip designed for difficult intubations and are available in Macintosh 4, 3 and 2. Supplied as a blade only in a case or as a blade and handle set in a case.
Delivery & Availability:
Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | Shipped from Abroad
The Genesis anaesthesia workstations meet your most ambitious requirements. They stand out for their lung protective ventilation.
Application Field: Neonates, Pediatrics & Adults
Ventilation Modes: Volume controlled (VC), Pressure controlled (PC), Adaptive Pressure with Volume Guaranteed (APVG) & Pressure Support Ventilation (PSV)
Delivery & Availability:
Typically 21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. |
Content | https://youtu.be/Id0Ma1_lEo0?si=kRJ1bUMjUCBuCAqR
Features of Dolphin TCD Machine
| Four sizes from small adult to extra large adult. A range of color-coded economy anesthetic face masks for single patient use to prevent the possibility of cross infection.
Features:
- Soft cushion for patient comfort and air tight fit
- Clear flexible housing and cushion for good patient visibility
- Four sizes available, from small adultl to extra large adult
- Each mask supplied with color-coded hook ring.
| Two speed fan motor and two levels of flow rates. CWS 5000 can inflate a very large blanket as well as a small blanket.
• Uses a DC motor, quieter and state of the art blower.
• CWS 5000 is controlled and operated through a unique robust software developed by Care Essentials.
• The Cocoon™ CWS 5000 is light and compact, yet very sturdy.
• Designed to be user friendly.
• We comply with all essential regulatory standards. We have FDA, CE, TGA, Japan Health approvals. CWS 5000 has been tested for IEC 60601-1 3rd Edition, AM 1 by UL, USA. |
- Compact design
- save space in O.R or Laboratory Room
- High quality & Durability design
- Easy operation & easy maintenance
- New integrated respiratory circuit available with own patent
- LED Ventilator inside & One standard ZF-1000 precise vaporizer
- Optional: Two precise ZF-1000 vaporizers
| Sirius-XL Eclipse blades feature a flexible tip designed for difficult intubations and are available in Macintosh 4, 3 and 2. Supplied as a blade only in a case or as a blade and handle set in a case.
- The non-replaceable glass fibre bundle is fully enclosed in the blade which allows easy cleaning.
- Rigid metal construction from fully autoclaveable, antimagnetic stainless steel.
- Lever positioned at the rear of the blade to control the tilting tip.
- 3 metal ball bearings for secure fitting.
- Green ISO 7376 fitting metal block compatible with fibre optic handles.
- Tilting tip for elevation of the epiglottis, providing an improved view of the larynx, without excessive force.
- Atraumatic distal end.
- Fully autoclaveable metal blade, covered by a 5 year guarantee or 4,000 autoclaves, whichever is sooner.
| The Genesis anaesthesia workstations meet your most ambitious requirements. They stand out for their lung protective ventilation, accuracy and performance, cost saving, design and ergonomics, safety and versatility.
TECHNICAL SPECIFICATION
OPERATING DATA
- Weight - 105 kg
- Dimensions - 92 cm Wide x 68 cm Deep x 139 cm High (93 cm to the table surface)
- Packaging Dimensions - 105 cm Wide x 75 cm Deep x 160 cm High
- Operating voltage supply - 110 to 240 V~, 47 to 63 Hz (12 to 6 A)
- Power input - 120 W typically (max. 1.2 kW with auxiliary outlets used)
- Battery autonomy - 90 min typically
- Auxiliary power outlets - 4, with automatic protection
- O2, N2O and Air supply - 2.7 to 6.9 bar (39.1 to 100 psi)
- Screen - TFT 18.5" (47 cm) projected capacitive touchscreen
- Protection class - Class I, gas analyser type BF defibrillation proof
- Classification - Class II b
- Storage - One front drawer with self-brake system and two back cabinets with door
- Lighting - LED bar below the screen controlled from the touchscreen
- Auxiliary integrated systems - Auxiliary 02 flow meter (0-15 L/min), Auxiliary 02 suppy valve (NF standard) and Suction device
- Communication ports - 1 x RS-232, 2 x USB, 1 x LAN Ethernet
Fresh Gases (02, N20 and Air, electronically controlled)
- Fresh gas flow - 0 and 0.1 to 18 L/min 02/N20/Air
- Accuracy - 0.1 to 0.5 L/min = ±0.05 L/min; 0.5 to 18 L/min = ±10 %
- 02 concentration - 21 to 100% vol. with Air, 25 to 100% with N20 (minimum 200 ml/min 02)
- 02 Safety fresh gas (backup) - 0-0.2-0.4-0.7-1-1.5- 2- 3- 4- 6- 8-10-12-15 L/min 02
- 02 flush (+02) - 40 L/min standard (adjustable 25 - 75 L/min upon requirement)
Breathing System (CABS)
- Autoclavable - 134 °C
- Weight of breathing system - 9.8 kg
- C02 absorber volume - 1.5 L
- Leakage - < 150 mL/min (at 30 hPa)
- Pressure limiting valve APL - 0 to 70 hPa
- Pressure relief valve - 125 hPa
- Vacuum safety valve - 0.3 hPa
- resistance at 60L/min - 5.80 hPa
- resistance at 60L/min - 2.90 hPa
- resistance at 30L/min - 3.55 hPa
- resistance at 30L/min - 0.89 hPa
- Internal Compliance at 30 hPa - 15 mL
VENTILATOR
Operation / Ventilation Modes
Volume controlled (VC) modes:
- Volume Controlled Ventilation (VCV)
- VC Synchronized Intermittent Mandatory Ventilation (VC-SIMV)
- VC-SIMV with Pressure Support (VC-SIMV-PS) *
Pressure controlled (PC) modes:
- Pressure Controlled Ventilation (PCV)
- PC Synchronized Intermittent Mandatory (PC-SIMV)
- PC-SIMV with Pressure Support (PC-SIMV-PS) *
Adaptive Pressure with Volume Guaranteed (APVG) modes (other trade names: Autoflow,PCVR, PRVC, AVAPS, VC+)
- Adaptive Pressure with Volume Guaranteed (APVG) *
- APVG Synchronized Intermittent Mandatory (APVG-SIMV) *
- APVG -SIMV with Pressure Support (APVG-SIMV-PS) *
Pressure Support Ventilation (PSV) *
- (other trade names: PS, ASB, SPS, IPS)
Non-mechanical Operation / Ventilation Modes
- Manual ventilation through the CABS system (Auto/Manual software controlled)
- Spontaneous ventilation either through the bellows (auto mode) or through the bag
- (manual mode) Manual ventilation through the external fresh gas outlet for non-rebreathing systems (Bain, Mapleson, ...)
Application field: Neonates, Pediatrics & Adults
- Tidal volume - 5 to 1500 mL
- Inspiratory pressure - 0 to 68 hPa
- Ventilation frequency - 3 to 120/min
- Inspiratory time - 0.05 to 16.6s
- l:E ratio - 5:1 to 1:8
- Inspiratory pause - 0 to 60%
- Inspiratory flow - max. 150 L/min
- PEEP - 0 to 30 hPa
- Flow trigger - 0.2 to 15 L/min
- Pressure support - 5 to 50 hPa
- Ramp time - 0.1 to 2 s
- Maximum pressure - 0 to 68 hPa
MONITORING
- 5" (47 cm) projected capacitive touchscreen, supported on a 360° rotating and 2 axis tilting arm.
- Measurements displayed: Peak pressure; Plateau pressure; Mean pressure; Expiratory minute ventilation; Expiratory tidal volume; Inspiratory tidal volume; Expiratory volumeter; Breathing rate; Compliance and Resistance (in VC modes); Patient info (age, weight, MAC, Class ASA); Connected sensors; Battery status; Power supply status; Gases supply pressures for 02, N20 and Air; Inspiratory and expiratory concentration of 02, N20, C02 and Anaesthetic gas*
- Parametres charted as curves (up to 3 simultaneously): Airway pressure; Expiratory flow; Inspiratory flow; Volume; Fresh gases (Rotstyle); Concentration of 02, N20, C02 and Anaesthetic gas*; Trends: Minute volume, MAC and gases (02, N20, C02 and Anaesthetic gas).
- Display for the performance of the hospital Anaesthetic Gas Scavenging System (AGSS).
- Configurable interface: bright/dark, multi-language.
- Loops (up to 2 simultaneously): Volume-Pressure, Flow-Volume, Pressure-Flow, C02-Volume.
- Fresh gas virtual rotameters for 02, N20, Air. * C02, N20 and Anaesthetic gas monitoring with the accessory multigas analyzer main-stream or side-stream; 02 real-time monitoring via paramagnetic
|
Reviews