The DrGem Ceiling Analogue X-ray Machine is a diagnostic radiography system that provides reliable high quality radiographic images with a reduced dose. The reliable high-frequency x-ray generators that are known worldwide for their excellent performance, lifetime and stability. Patient tables and wall stands are also offered.

Delivery & Availability:
Typically 21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.

SF1033560074-7
DrGem Corporation

Description

DrGem Ceiling Analogue X-ray Machine is a diagnostic radiography system X-ray Machine that provides reliable high quality radiographic images with a reduced dose. The reliable high-frequency x-ray generators that are known worldwide for their excellent performance, lifetime and stability. Patient tables and wall stands are also offered.

Features of DrGem Ceiling Analogue X-ray Machine

  • TS-CSA-A (Vertical movement, 1.6m stroke, rail length 3x4meter) including HV cable 15m
  • WBS-TA:  Vertical movement
  1. V Stroke:1,450mm in Uprigh Bucky Position,
  2. 1,526mm in Horizontal Bucky position.
  • PBT-4 is a 4 way Floating Tabletop with. A large tabletop with extended travel enables all radiography studies with minimal patient movement. Fully fat tabletop without a frame on the edge makes cleanliness and odors free

Technical Specifications of DrGem Ceiling Analogue X-ray Machine

  • Power Rating – 32KW
  • Generator – GXR-32S
  • Rotor – Dual Speed Starter(DSS)
  • Input Power – 400/480VAC, Three phase
  • Line Frequency – 50/60Hz
  • X-ray tube – DXT-12M, (0.6/1.2mm, 300kHU)
  • Tube Voltage – 40 to 150kV, 1kV Step
  • Tube Current – 10 to 640mA
  • Output – 640mA@81kV,  500mA@104kV, 400mA@130kV, 320mA@150kV
  • Time Range – 1ms to 10s
  • mAs Range – 0.1 to 800mAs
  • Reproducibility – Coe­cient of Variation : kV < 0.005, Time < 0.005,mAs < 0.01
  • Accuracy – kV < ±(1%+1kV), mA < ±(3%+1mA), Time <±(1%+0.5ms), mAs < ±(3%+0.1mAs)
  • Linearity – Coe­cient of Linearity < 0.01 : CL = (X1-X2)/(X1+X2), where X is mR/mAs
  • Mechanical Parts:

-TS-CSA-A (Vertical movement, 1.6m, stroke rail length 3x4meter) including HV cable 15m

– PBT-4: 4 way Floating Tabletop with Elevating Feature (66cm).

– WBS-TA:   a.  Vertical    movement

  1.   V Stroke:1,450mm in Upright Bucky
  2. Position, 1,526mm in Horizontal Bucky position.

– HVC-15: 15M HV cable

– Auto Collimator

 

Click Here To Download Catalogue

Review(1)

0 average based on 0 ratings.
  1. vorbelutrioperbir

    Only wanna input that you have a very nice website , I enjoy the design it really stands out.

    (0) (0)
Add a review

Your email address will not be published. Required fields are marked *

Quick Comparison

SettingsDrGem Ceiling Analogue X-ray Machine removeSIGNERS SUPiA Dry Thermal X-ray Film Printer removeSonoscape E2 Ultrasound Machine removeSonoscape E1 Ultrasound Machine With Two Probes removeASPEL AsCARD Grey ECG Machine removeDrGem Floor Mounted Analogue X-ray remove
NameDrGem Ceiling Analogue X-ray Machine removeSIGNERS SUPiA Dry Thermal X-ray Film Printer removeSonoscape E2 Ultrasound Machine removeSonoscape E1 Ultrasound Machine With Two Probes removeASPEL AsCARD Grey ECG Machine removeDrGem Floor Mounted Analogue X-ray remove
ImageDrGem GXR-S 400mA Ceiling Mounted Analogue X-ray MachineSigners Dry Thermal X-ray Film Printerportable ultrasound machineASPEL AsCARD Grey ECG MachineDrGem GXR-S 400mA Floor Mounted Analogue X-ray Machine
SKUSF1033560074-7SF1033560050-02SF1033560012-17SF1033560012-20SF1033560075-5SF1033560074-6
Rating
Price

$0.00

$0.00

$4,300.00

$0.00

$0.00

$26,924.00

Stock
Availability
Add to cart

DescriptionShipped from abroad The DrGem Ceiling Analogue X-ray Machine is a diagnostic radiography system that provides reliable high quality radiographic images with a reduced dose. The reliable high-frequency x-ray generators that are known worldwide for their excellent performance, lifetime and stability. Patient tables and wall stands are also offered. Delivery & Availability: Typically 21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.Shipped from Abroad Signers Digital Dry Thermal X-ray Film Printer - Is a dry imager designed to output information processed through DICOM network protocol, supports 4 films sizes. 8”x10”, 10”x12”, 11”x14” and 14”x17” Achieve the convenience of multiple sizes.

Delivery & Availability:

Typically 14 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped from Abroad Sonoscape E2 portable ultrasound machine is a color Doppler ultrasound system that reaches beyond your expectations due to its compact and fashionable appearance. It fulfills GI, OB/GYN, Cardiac and POC applications to fit your routine scanning needs while its color mode will help you for more accurate and efficient diagnosis of lesions. E2 provides a wide range of applications to assist users with routine scanning. E2 provides automatic calculations to enhance your diagnostic confidence and save you time for patient communication. Delivery & Availability: Typically 14 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.Shipped from Abroad SonoScape has developed a new probe and function for the E1 Exp. With these additions the E1 Exp will bring users a more efficient examination experience with satisfying image quality and a smooth workflow. Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.Shipped from Abroad Electrocardiograph AsCARD Grey v.07.225 - is a 1, 3, 6, 12 channel ECG unit which enables to make electrocardiogram in full 12 leads. It is intended to conduct ECG examinations of adults and paediatric patients in all types of health care centres. ECG examination may be recorded in manual or automatic mode, with the possibility of analysis and interpretation. The device can be powered from 100 V ÷ 240 V mains supply or by an internal battery. Delivery & Availability: Typically 10 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.In Stock GXR Analogue X-ray system matches with a radiographic room which perfectly fits your workow and can be easily upgraded to DR system with the help of DR interface and PC interface in GXR generator as well as Bucky suitable to Flat Panel Detector. GXR X-ray system is equipped with a high frequency X-ray generator which consistently produces high quality radiograph in favor of high quality X-ray output with a very small kV ripple and accurate mA and mAs. GXR X-ray system is designed to provide convenience to operator and comfort to patient. Delivery & Availability: Typically 21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
ContentDrGem Ceiling Analogue X-ray Machine is a diagnostic radiography system X-ray Machine that provides reliable high quality radiographic images with a reduced dose. The reliable high-frequency x-ray generators that are known worldwide for their excellent performance, lifetime and stability. Patient tables and wall stands are also offered. Features of DrGem Ceiling Analogue X-ray Machine
  • TS-CSA-A (Vertical movement, 1.6m stroke, rail length 3x4meter) including HV cable 15m
  • WBS-TA:  Vertical movement
  1. V Stroke:1,450mm in Uprigh Bucky Position,
  2. 1,526mm in Horizontal Bucky position.
  • PBT-4 is a 4 way Floating Tabletop with. A large tabletop with extended travel enables all radiography studies with minimal patient movement. Fully fat tabletop without a frame on the edge makes cleanliness and odors free
Technical Specifications of DrGem Ceiling Analogue X-ray Machine
  • Power Rating - 32KW
  • Generator - GXR-32S
  • Rotor - Dual Speed Starter(DSS)
  • Input Power - 400/480VAC, Three phase
  • Line Frequency - 50/60Hz
  • X-ray tube - DXT-12M, (0.6/1.2mm, 300kHU)
  • Tube Voltage - 40 to 150kV, 1kV Step
  • Tube Current – 10 to 640mA
  • Output - 640mA@81kV,  500mA@104kV, 400mA@130kV, 320mA@150kV
  • Time Range - 1ms to 10s
  • mAs Range - 0.1 to 800mAs
  • Reproducibility - Coe­cient of Variation : kV < 0.005, Time < 0.005,mAs < 0.01
  • Accuracy - kV < ±(1%+1kV), mA < ±(3%+1mA), Time <±(1%+0.5ms), mAs < ±(3%+0.1mAs)
  • Linearity - Coe­cient of Linearity < 0.01 : CL = (X1-X2)/(X1+X2), where X is mR/mAs
  • Mechanical Parts:
-TS-CSA-A (Vertical movement, 1.6m, stroke rail length 3x4meter) including HV cable 15m - PBT-4: 4 way Floating Tabletop with Elevating Feature (66cm). - WBS-TA:   a.  Vertical    movement
  1.   V Stroke:1,450mm in Upright Bucky
  2. Position, 1,526mm in Horizontal Bucky position.
- HVC-15: 15M HV cable - Auto Collimator  
Click Here To Download Catalogue
Signers Digital Dry Thermal X-ray Film Printer - Is a dry imager designed to output information processed through DICOM network protocol, supports 4 films sizes. 8”x10”, 10”x12”, 11”x14” and 14”x17” Achieve the convenience of multiple sizes. Technical Specifications:
  • Print Technology - Direct thermal (dry, daylight-load film)
  • Spatial Resolution - 320dpi (12.6 pixels/mm)
  • Throughput - 14”x17” ≥ 50 sheets/h, 8”x10” ≥ 70 sheets/h
  • Film Tray - 2 supply tray
  • Gray scale Contrast Resolution - 14 bits
  • Network Protocol - Standard DICOM 0 connection
  • Film Transferring Method - Rubbing
 
Click Here To Download Catalogue
SONOSCAPE E2 DETAILS Auto Image Optimization A portable ultrasound machine with the press of a button, the image is automatically adjusted and optimized, saving you time with parameter adjustments. Additionally, with Auto Focus on, the focus area follows the depth of the ROI box as it is moved in the scanning field, providing users with excellent image quality in the desired area of interest. Automated Calculation Auto IMT is used when determining the level of vascular sclerosis present in the patient by automatically tracing the thickness of the carotid vessels. Auto trace provides users sensitive and accurate wave tracing, avoiding the error of manual trace and giving out calculation result in no time In-Build Battery pack This portable ultrasound machine was equipped with an in-build battery pack which enable the user to perform image scanning when AC power is not available.  
Click Here To Download Catalogue
DETAILS Efficient Diagnosis μ-Scan, Speckle Reduction & Edge Enhancement Spatial Compound Imaging PIH - Pure Inversion Harmonic Wide Scan - Enlarged Image Area Tissue-Specific Imaging SR Flow Ergonomic Designs Up to 2 Transducer Ports Light Weight and Compact 15.6 inch Anti-flickering HD LED Screen Tilting Monitor Angle Adjustment Backlit Keyboard and Intelligent Panel Long-lasting Battery for 90 mins Ease of Use Quick Boot Up Auto-Brightness Adjustment Auto Image Optimization Auto IMT Auto Trace Equipped Accessories Wi-Fi and Bluetooth Available DICOM 500GB Hard Disk Height Adjustable Trolley Durable, Carry-on Site Suitcase  
Click Here To Download Catalogue
Electrocardiograph AsCARD Grey v.07.225 - is a 1, 3, 6, 12 channel ECG unit which enables to make electrocardiogram in full 12 leads. It is intended to conduct ECG examinations of adults and paediatric patients in all types of health care centres. ECG examination may be recorded in manual or automatic mode, with the possibility of analysis and interpretation. The device can be powered from 100 V ÷ 240 V mains supply or by an internal battery. Technical Specification:1. Visualisation of 1, 3, 6 or 12 ECG waveforms, analysis results and interpretations, examinations stored in memory. 2. Recording of 12 standard leads. 3. Print out in 1, 3, 6 or 12 ECG waveforms mode. Printing of a selected group:
  • 1 channel - (I, II, III, aVR, aVL, aVF, V1, V2, V3, V4, V5, V6),
  • 3 channels in standard format - (I-II-III, aVR-aVL-aVF, V1-V2-V3, V4-V5-V6),
  • 3 channels in Cabrera format - (aVL-I-aVR, II-aVF-III, V1-V2-V3, V4-V5-V6),
  • 6 channels in standard format - (I-II-III-aVR-aVL-aVF, V1-V2-V3-V4-V5-V6),
  • 6 channels in Cabrera format - (aVL-I-aVR-II-aVF-III, V1-V2-V3-V4-V5-V6),
  • 12 channels in standard format - (I-II-III-aVR-aVL-aVF-V1-V2-V3-V4-V5-V6),
  • 12 channels in Cabrera format - (aVL-I-aVR-II-aVF-III-V1-V2-V3-V4-V5-V6).
4. Available types of examinations: manual, AUTO, SPIRO, automatic to clipboard, AUTOMANUAL, LONG (v.07.xx5). 5. Automatic record ECG signal from all 12 leads simultaneously, with save to temporary memory function, then depending on the settings: print out examination's result, analysis, interpretation or save to database. 6. Adjustable length of automatic examination recording — interval of 6–30 seconds. 7. Reverse recording in automatic examination to clipboard and in manual examination (v.07.xx5). 8. Rhythm print out in AUTO examination and automatic examination to clipboard. 9. Definable stages of examination according to set up parameters in AUTOMANUAL examination. 10. Storing an examination in memory, 1–15 minutes in LONG mode (v.07.xx5). 11. ECG printed directly from the electrocardiograph using PCL5/6 printer. 12. Printout from database. Possibility to printout additional information about examination or patient. 13. Alpha-numerical soft-key keyboard with functional buttons. 14. Possibility to set parameters: speed, sensitive, intensity of printing. 15. Menu displayed on the screen for easy operation using touch panel. 16. Database of patients and examinations. Internal memory up to 1000 patients, 1000 examinations. 17. Viewing of the memory-stored examinations on display, with the possibility of changing the number of leads, augmentation and speed. 18. Automatic analysis and interpretation in compliance with EN 60601-2-51 (CSE database) - Analysis and interpretation dependable on age & sex of a patient. 19. Up to 130 automatic examinations in battery mode. 20. Continuous heart rate (HR) measurement and display. 21. Adapted to direct operation on an open heart. 22. Device allows to enable and disable the following filters:
  • power line interference filter; filters available: 50 Hz, 60 Hz,
  • muscle interference filter; filters available: 25 Hz, 35 Hz, 45 Hz,
  • contour line filters; filters available: 0.15 Hz, 0.45 Hz, 0.75 Hz, 1.5 Hz,
  • the low-pass filter (v.07.224, v.07.324, v.07.225, v.07.325): 75 Hz, 100 Hz, 125 Hz, 150 Hz,
  • the auto-adaptive filter (v.07.224, v.07.324, v.07.225, v.07.325).
23. Detection of electrode detachment, independent for each channel (INOP control). 24. Detection of cardiac stimulator. 25. Sound signalling of detected stimulations of heart stimulator. 26. Protection against defibrillation pulse. 27. ECG recordings optionally saved on PenDrive, send on email or to other AsCARD via EKG-MAIL. 28. Wireless communication with the LAN or the Internet (v.07.3xx). 29. Wired communication with the LAN or the Internet. 30. Cooperation with CardioTEKA and CardioTEL. 31. Possibility of accepting orders for examination and sending back the results in HL7 standard via Internet (v.07.3xx). 32. Possibility of conducting preliminary spirometry examinations by using SPIRO-31 attachment. 33. EMR – keep performed examinations in specified period of time on external data storage (USB memory). Accessories 1. Limb electrodes, 4 pieces (EKK type). 2. Chest electrodes, 6 pieces (EPP type). 3. KEKG 30R ECG cable. 4. Main cable. 5. R-A4 paper, 112 mm wide (1 reel). 6. ECG gel. 7. Operation manual.  
Click Here To Download Catalogue
DrGem GXR Floor Mounted Analogue X-ray system matches with a radiographic room which perfectly fits your workflow and can be easily upgraded to DR system with the help of DR interface and PC interface in GXR generator as well as Bucky suitable to Flat Panel Detector. GXR (Analogue X-ray)system is equipped with a high frequency X-ray generator which consistently produces high quality radiograph in favor of high quality X-ray output with a very small kV ripple and accurate mA and mAs. GXR (Analogue X-ray) system is designed to provide convenience to operator and comfort to patient. Features of DrGem GXR Floor Mounted Analogue X-ray:
  • 4 way Tabletop Patient Table (PBT-4) A large tabletop with extended travel enables all radiography studies with minimal patient movement, and supporting patient weight up to 300kg. Fully at tabletop without a frame on the edge makes cleanliness and odors free
  • Floor Mount Tube Stand (TS-FM6) Floor Rail type tube stand provides all radiography studies with smooth movement on the rail.
  • Wall Bucky Stand (WBS) Elegant design, durable and easy-to-use Wall Bucky Stand provides full satisfaction.
Technical Specifications of DrGem GXR Floor Mounted Analogue X-ray:
  • Power Rating - 32KW
  • Generator - GXR-32S
  • Rotor - Dual Speed Starter(DSS)
  • Input Power - 400/480VAC, Three phase
  • Line Frequency - 50/60Hz
  • X-ray tube - DXT-12M, (0.6/1.2mm, 300kHU)
  • Tube Voltage - 40 to 150kV, 1kV Step
  • Tube Current – 10 to 640mA
  • Output - 640mA@81kV,  500mA@104kV, 400mA@130kV, 320mA@150kV
  • Time Range - 1ms to 10s
  • mAs Range - 0.1 to 800mAs
  • Reproducibility - Coe­cient of Variation : kV < 0.005, Time < 0.005,mAs < 0.01
  • Accuracy - kV < ±(1%+1kV), mA < ±(3%+1mA), Time <±(1%+0.5ms), mAs < ±(3%+0.1mAs)
  • Linearity - Coe­cient of Linearity < 0.01 : CL = (X1-X2)/(X1+X2), where X is mR/mAs
 
Click Here To Download Catalogue
WeightN/AN/AN/AN/AN/AN/A
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • Rating
  • Price
  • Description
Click outside to hide the comparison bar
Compare