Drying oven PE-4610 (vertical) (65 L / 300°С)

Ask for Price$0.00

Shipped From Abroad

The drying oven is to be used for drying, firing, melting, curing and sterilization of various articles, treatment of tools and samples as well as performance of laboratory investigations of every sort and kind in the laboratories of industrial enterprises, research establishments and medical institutions, colleges, universities, etc.

Delivery & Availability:
Typically 14-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.

SF10335601088
Brands:: ECROSKHIM

Description

Purpose:
The drying oven is to be used for drying, firing, melting, curing and sterilization of various articles, treatment of tools and samples as well as performance of laboratory investigations of every sort and kind in the laboratories of industrial enterprises, research establishments and medical institutions, colleges, universities, etc.

The following functions are implemented in the device:
– maintenance of the specified temperature with the required accuracy;
– digital indication of the specified temperature and current temperature of the working chanber;
– overheating protection with the operation alarm;
– setting the timer to stopping the heating;
– control of the rotation speed of the fan

Technical specifications:
– Working temperature range, °C – from ambient +10 to +300
– Temperature setting discreteness, °C – ±0.1
– Chamber volume, l – 56,3
– Standard/maximum number of shelves, pcs – 2/8
– Power consumption, W – 1600
– Supply voltage, V – 220 V, 50 Hz
– Chamber dimensions, mm – 372х338х448
– External dimensions, mm – 540х570х830
– Weight, kg – 42

The scope of delivery of the standard equipment includes:
1. Drying oven PE-4610 – 1 pc.
2. Shelf made of stainless steel – 2 pcs.
3. Mains cable – 1 pc.
4. Data Sheet and Operating Manual – 1 pc.

Reviews

There are no reviews yet.

Be the first to review “Drying oven PE-4610 (vertical) (65 L / 300°С)”

Your email address will not be published. Required fields are marked *

Quick Comparison

SettingsDrying oven PE-4610 (vertical) (65 L / 300°С) removeZenithlab (IB-9025A) Laboratory Incubator removeTest Strip for ApexBio HemoSmart Gold Hemoglobin Meter removeSkyla Hi POC Clinical Chemistry Analyzer removeSugentech Inclix (POCT) Immunoassay Analyzer removeAvalun LabPad Device remove
NameDrying oven PE-4610 (vertical) (65 L / 300°С) removeZenithlab (IB-9025A) Laboratory Incubator removeTest Strip for ApexBio HemoSmart Gold Hemoglobin Meter removeSkyla Hi POC Clinical Chemistry Analyzer removeSugentech Inclix (POCT) Immunoassay Analyzer removeAvalun LabPad Device remove
ImageAvalun Labpad machine
SKUSF10335601088SF1033560084-109SF1033560084-30SF1033560060-2SF1033560084-89SF1033560084-65
Rating
Price

Ask for Price$0.00

$350.00

$9.50

Ask for Price$0.00

Ask for Price$0.00

Ask for Price$0.00

Stock
Availability
Add to cart

DescriptionShipped From Abroad

The drying oven is to be used for drying, firing, melting, curing and sterilization of various articles, treatment of tools and samples as well as performance of laboratory investigations of every sort and kind in the laboratories of industrial enterprises, research establishments and medical institutions, colleges, universities, etc.

Delivery & Availability: Typically 14-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock
  • Microprocessor control.
  • Digital display setting and actual temperature.
  • Over temperature alarm, PID self-tuning.
  • Digital display running timer.
  • Stainless steel interior.
  • Electricity leakage protection.
  • With glass inner door, With hidden door locks.
  • Mechanical overheat protection, cut off the heating sources.
  • Automatic alarm after operation.
  • Suitable for constant temperature tests.
  • Suitable for bacteria cultivation, breeding, ferment.
Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In Stock Twenty Five (25) Test Strip per Pack

Delivery & Availability:

Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped from Abroad The skyla Hi POC Clinical Chemistry Analyzer provides clinical testing laboratories of medical facilities and clinics with an in-vitro clinical chemistry diagnostic tool that is compact, portable, and reports rapid results.The use of skyla Hi in the management of diabetes enables better access to testing and rapid clinical decision making, discussion,and implementation of optimized treatment. Delivery & Availability: Typically 14 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.In stock INCLIX™ is an immunochromatographic analyzer providing immediate point-of-care testing (POCT) at patient care settings or clinical laboratories. It facilitates automatic detection of various biomarkers for cardiovascular disease, infectious disease, cancer, diabetes, allergy, and etc. with high accuracy and sensitivity. INCLIX™ analyzer is a compact, easy-to-use and cost-effective multi-parameter POCT instrument and its unique user friendly software provides an efficient data management system. Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.In stock The coagulometer, LabPad® INR, measures blood coagulation time thanks to a patented optical technology. This portable In-Vitro Diagnostics (IVD) device works with the Tsmart® INR single-use microcuvettes. Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Content

Purpose: The drying oven is to be used for drying, firing, melting, curing and sterilization of various articles, treatment of tools and samples as well as performance of laboratory investigations of every sort and kind in the laboratories of industrial enterprises, research establishments and medical institutions, colleges, universities, etc.

The following functions are implemented in the device: - maintenance of the specified temperature with the required accuracy; - digital indication of the specified temperature and current temperature of the working chanber; - overheating protection with the operation alarm; - setting the timer to stopping the heating; - control of the rotation speed of the fan

Technical specifications: - Working temperature range, °C – from ambient +10 to +300 - Temperature setting discreteness, °C - ±0.1 - Chamber volume, l – 56,3 - Standard/maximum number of shelves, pcs – 2/8 - Power consumption, W – 1600 - Supply voltage, V – 220 V, 50 Hz - Chamber dimensions, mm – 372х338х448 - External dimensions, mm – 540х570х830 - Weight, kg – 42 The scope of delivery of the standard equipment includes: 1. Drying oven PE-4610 – 1 pc. 2. Shelf made of stainless steel – 2 pcs. 3. Mains cable – 1 pc. 4. Data Sheet and Operating Manual – 1 pc.
Features:
  • Microprocessor control.
  • Digital display setting and actual temperature.
  • Over temperature alarm, PID self-tuning.
  • Digital display running timer.
  • Stainless steel interior.
  • Electricity leakage protection.
  • With glass inner door, With hidden door locks.
  • Mechanical overheat protection, cut off the heating sources.
  • Automatic alarm after operation.
  • Suitable for constant temperature tests.
  • Suitable for bacteria cultivation, breeding, ferment.
  Technical Specification: Model: IB-9025A Working size: 250x250x250mm/9.84x9.84x9.84inch Power: 150W Temperature range: Room temperature+5~65℃ Temperature resolution: 0.1℃ Temperature fluctuation: ±0.5℃ Timer: 0-9999min Voltage: 110V 60Hz / 220V 50Hz Dimension: 380x370x580mm/14.96x14.57x22.83inch Size: 52cm*46cm*75cm / 20.5in*18.2in*29.6in Gross Weight:42kg / 93lb Net Weight: 23kg / 51lb Warranty: 1 year
Twenty Five (25) Test Strip per Packskyla Hi Analyzer enables better access to testing and rapid clinical decision making, discussion, and implementation of optimized treatment. To get the result, only prepare <1 μl fingertips blood or venous blood (depends on test item) without pretreatment with easy steps and then read the result after 6 mins. The device allows two specimens be tested in one run and provides fully automatic procedures from checking the validity of cartridge to printing the results. Reagent Kit
  • HbA1C
  • CRP
  • Lipid Panel (TC,TG, HDL, LDL#)
  • Lipid Plus Panel (Glu,TC,TG, HDL, LDL#)
Main Specification
Principle
Turbidimetric Method / Biochemistry
Device
Testing Time
5~20 minutes (depends on test items)
Display and Interface
5″ TFT color touch screen LCD
Memory Capacity
50,000 test results
Dimension of Analyzer
270 x 188 x 148 mm
Weight of Analyzer
1.7 kg
Dimension of Printer Module
134 x 100 x 82.7 mm
Weight of Printer Module
0.37 kg
Power Supply
100~240 volts AC, 50-60Hz
Data Transmission
USB 2.0*4 / USB 3.0*1 / RS232*1 / RJ45*1 / Wi-Fi (optional)
Reagent and Samples
Samples
Fingertips blood or venous blood
Samples Volume
0.8 ~ 30 μL (depends on test item)
Storage Temperature (Reagent)
2 ~ 8˚C
Humidity
Relative humidity < 95% (Non-condensing)
Temperature
10 ~ 32 ˚C
Click Here To Download Catalogue
INCLIX™ is an immunochromatographic analyzer providing immediate point-of-care testing (POCT) at patient care settings or clinical laboratories. It facilitates automatic detection of various biomarkers for cardiovascular disease, infectious disease, cancer, diabetes, allergy, and etc. with high accuracy and sensitivity. INCLIX™ analyzer is a compact, easy-to-use and cost-effective multi-parameter POCT instrument and its unique user friendly software provides an efficient data management system. Features: • Good accuracy owning to superior CMOS sensor & our own Algorism • 10,000 test results data storage • Instrument Check by Reference Kit • Remote Support available (when connected via Internet) • Built-in Thermal Printer and Barcode Scanner • Data export to USB(PDF, Excel), Email and LIS • Storage Temperature of Test Cassette & Buffer : Room temperature, 2 ~ 30 ℃ • Shelf Life of Test Cassette & Buffer : 24 months  
Click Here To Download Catalogue
 
The coagulometer, LabPad® INR, measures blood coagulation time thanks to a patented optical technology. This portable In-Vitro Diagnostics (IVD) device works with the Tsmart® INR single-use microcuvettes.
  • User-friendly: the LabPad® INR is designed to be easy to use especially thanks to its 3D-shaped microcuvette that only requires a small drop of blood from a fingertip. Thanks to the color screen, both measurement steps and browsing the list of results are easy to visualize.
  • Quick and reliable: the reliability of INR results is obtained by quality controls that are performed automatically before each measurement. In less than one minute, you can see if you are in your therapeutic range.
  • Connected: the result obtained after performing the test can be transferred to healthcare professionals in charge of your treatment monitoring. This result is complementary to the pie charts and trend reports directly displayed on the LabPad® INR to help you monitoring your treatment
 
Click Here To Download Catalogue
   
WeightN/AN/AN/AN/AN/AN/A
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • Rating
  • Price
  • Description
Click outside to hide the comparison bar
Compare