Description | Shipped From Abroad
Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| In stock
The coagulometer, LabPad® INR, measures blood coagulation time thanks to a patented optical technology. This portable In-Vitro Diagnostics (IVD) device works with the Tsmart® INR single-use microcuvettes.
Delivery & Availability:
Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | In stock
This Automatic Pipette will help you get your lab up and running in no time—at a great price!
Delivery & Availability:
Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | In stock
The Discover Cup is an all-in-one drug of abuse test cup. The strips are self contained and the entire cup is tamper resistant.
Delivery & Availability:
Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | In stock
Powerful and user-friendly MiniSpin Centrifuge are small enough so that each workstation can be equipped with a “personal” centrifuge. The rotor, inner centrifuge lid, and lid latch are made of metal for maximum operation safety.
Delivery & Availability:
Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | Shipped From Abroad
Electrolyte Analyzer ERMA EL-120 is ideal for medium to high volume Laboratories and Hospitals . It offers reliable, automated samples handling and work flow offences . It also allows measurement of specific ions, accurately and precisely . This supports fast diagnosis of critically ill patients and reduces the risks of patient discomfort associated with repeated sampling Precise & Accurate Results Economical to use Large Touchscreen Display with Graphical User Interface.
Delivery & Availability:
Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. |
Content |
|
The coagulometer, LabPad® INR, measures blood coagulation time thanks to a patented optical technology. This portable In-Vitro Diagnostics (IVD) device works with the Tsmart® INR single-use microcuvettes.
- User-friendly: the LabPad® INR is designed to be easy to use especially thanks to its 3D-shaped microcuvette that only requires a small drop of blood from a fingertip. Thanks to the color screen, both measurement steps and browsing the list of results are easy to visualize.
- Quick and reliable: the reliability of INR results is obtained by quality controls that are performed automatically before each measurement. In less than one minute, you can see if you are in your therapeutic range.
- Connected: the result obtained after performing the test can be transferred to healthcare professionals in charge of your treatment monitoring. This result is complementary to the pie charts and trend reports directly displayed on the LabPad® INR to help you monitoring your treatment
| This Automatic Pipette will help you get your lab up and running in no time—at a great price!
Features:
- Lowest operation and tip ejection forces
- Fully autoclavable
- Ultra light weight with space-age materials
- Secondary adjustment option for various liquid classes
- Spring loaded tip con
- For transferring molecular samples and PCR mix solutions.
- One set is for DNA work and the other for RNA work. Each with the following specs
- Light weight, traditional tip shaft, and will fit all generic brands of tips
- Equal to or better than accuracy and precision compared to ISO 8655, so results can be trusted.
- Easy and quick volume adjustment with or without gloves. Foolproof volume lock prevents accidental volume changes.
- Low maintenance and autoclavable 121° for at least 20 minutes
- Quick release
|
FDA 510(K) & CLIA Waived
Up to 99% accuracy rate
Results in as little as 1 minute
24 Month Shelf Life from Date of Manufacture
Secure, seal and send to lab for confirmation
Built in temperature strip
Available to test up to 17 substances with adulterants or 18 without adulterants
Adulterants available
| Powerful and user-friendly MiniSpin Centrifuge are small enough so that each workstation can be equipped with a “personal” centrifuge. The rotor, inner centrifuge lid, and lid latch are made of metal for maximum operation safety.
Features:
- Rotor capacity: 12 x 1.5/2.0 mL vessels, 2 x PCR strip
- Max. speed: 14,100 x g (14,500 rpm)
- Extremely compact footprint — measures 9”W x 4.”H x 9ó”D!
- Aluminum rotor accommodates twelve 1.5- or 2.0-mL tubes (maximum diameter of 11 mm)
- Rotor can be autoclaved at 121°C for 20 minutes
- Minimal sample heat transfer — maximum of 12°C after 20 minutes at max speed
- Eliminate costly repairs with the low maintenance drive
- Soft-touch lid closure for ergonomic lid locking — and releases automatically at the end of a run
Technical Specifications:
Speed: |
800 – 13,400 rpm (100 rpm steps) |
Capacity: |
12 x 1.5/2.0 mL |
Electrical: |
120 V, 60 Hz |
Dimensions: |
(W x D x H) 22.6 x 23.9 x 12.0 cm |
Weight: |
4.3 kg |
| Electrolyte Analyzer ERMA EL-120 is ideal for medium to high volume Laboratories and Hospitals . It offers reliable, automated samples handling and work flow offences . It also allows measurement of specific ions, accurately and precisely . This supports fast diagnosis of critically ill patients and reduces the risks of patient discomfort associated with repeated sampling Precise & Accurate Results Economical to use Large Touchscreen Display with Graphical User Interface.
Features:
- Parameters: Na+,K+,Cl-, iCa++ / Li
- It works on ISE principle
- Sample Type: Whole blood, Serum, Plasma, Urine
- Low reagent consumption
- Sample requirement is only 90ul
- 60 samples per hour
- Automatic two point calibration after 4hrs and one point calibration with each sample analysis
- Air bubble detection
- Track reagents consumption and provides alerts
- For low reagent volume
- Precision testing facility to get CV and SD
- Trilevel Quality Control with LJ plots of last 30days
- Low aspiration volume
- Fast sample processing
- Accurate and Precise results
Technical Specifications:
Parameters |
Na+, K+, Cl– /Ca++ |
Principle |
Ion Selective Electrode (ISE) |
Sample Type |
Analyses whole blood, serum, plasma and urine |
Sample Volume |
≤100 µL |
Analysis Time |
≤60 seconds |
Throughout |
≤60 samples per hour |
Data Link |
Serial (RS232) |
External Interface |
USB (Keyboard, Mouse) |
Operating Condition |
10° C to 35° C, Relative Humidity up to 85% |
Storage Condition |
Temp: 10° C to 40° C |
Relative Humidity |
up to 85% non- condensing |
Power Supply |
100 to 240 VAC ±10%, 50Hz |
Dimensions |
395 x 260 x 375 mm |
Weight |
7.5 kg |
|