Extractor PE-8000

$0.00

Shipped From Abroad

Purpose:
PE-8000 extractor shall be used for extraction concentration of heavy metals, petroleum hydrocarbons, polyaromatic hydrocarbons, organochlorine compounds and other pollutants from water samples by any organic solvents in separating funnels, round-bottomed flasks and flat-bottomed flasks, .

Delivery & Availability:
Typically 14-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.

SF10335601085
Brands:: ECROSKHIM

Description

Purpose:
PE-8000 extractor shall be used for extraction concentration of heavy metals, petroleum hydrocarbons, polyaromatic hydrocarbons, organochlorine compounds and other pollutants from water samples by any organic solvents in separating funnels, round-bottomed flasks and flat-bottomed flasks, with the IM9 fluoroplastic turbine stirrer used to create high-speed radial liquid flows to ensure effective mixing and uniform distribution of extraction agent throughout the sample volume.
Extractor is provided with electronic stepless speed control unit.
Extractor is provided with built-in control unit with large LCD. It is possible to set a timer.

Technical specifications:
– Volume of stirred sample, L – 1.0
– Rotation speed of stirrer shaft, rpm – 100-3000
– Maximum torque, H-cm – 60
– Maximum diameter stirrer shaft, mm – 10
– Accuracy of speed maintenance, rpm, at least – ±20
– Stirrer material – PTFE and stainless steel
– Stirrer type – turbine
– Maximum power consumption, W – 100
– Power supply voltage (50 Hz), V – 220 ± 10
– Overall dimensions (with rack), mm – 420х380х800
– Weight, kg – 9

Scope of delivery: 
1. Overhead stirrer PE-8300 – 1 pc.
2. ES-2720 rack for stirrers – 1 pc.
3. Clamp for fastening the stirrer on the rack – 1 pc.
4. Clamp for fastening holding ring on the rack – 1 pc.
5. Fluoroplastic turbine stirrer IM9 – 1 pc.
6. ТS-2 sealing unit made of fluoroplastic – 1 pc.
7. Holding ring – 1 pc.
8. Round separating funnel – 1 pc.

Reviews

There are no reviews yet.

Be the first to review “Extractor PE-8000”

Your email address will not be published. Required fields are marked *

Quick Comparison

SettingsExtractor PE-8000 removeAlcohol Pad Per Pack removePlastic Urine Container Per Pack removeErma B-111 Bilirubin Meter removeiSED Fully Automated ESR Analyzer removeEppendorf Pipette Tip 200ul Per Pack remove
NameExtractor PE-8000 removeAlcohol Pad Per Pack removePlastic Urine Container Per Pack removeErma B-111 Bilirubin Meter removeiSED Fully Automated ESR Analyzer removeEppendorf Pipette Tip 200ul Per Pack remove
ImageEppendorf Pipette Tip 200ul Per Pack
SKUSF10335601085SF1033560084-64SF1033560084-106SF1033560084-6SF1033560084-129SF1033560084-137
Rating
Price

$0.00

$4.25

$8.20

$715.00

$0.00

$0.00

Stock
Availability
Add to cart

DescriptionShipped From Abroad

Purpose: PE-8000 extractor shall be used for extraction concentration of heavy metals, petroleum hydrocarbons, polyaromatic hydrocarbons, organochlorine compounds and other pollutants from water samples by any organic solvents in separating funnels, round-bottomed flasks and flat-bottomed flasks, .

Delivery & Availability: Typically 14-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock Alcohol Pad (70% Isopropyl Alcohol Pre Pad, Alcohol Cleansing Swab). Clean the required area. Discard after single use. Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.In stock
  • Total Volume: 60mL.
  • Specimen Container, Leak-proof, Ideal for Pathology/Histology/Cytology reagent pre-filling sample preparation.
  • Made of premium PP material, it is durable for usage.
  • Some measurements can be used to not only use urine samples, it can also be used for other liquids.
Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Aboard  The advanced B111 Bilirubinmeter provides fast, accurate results for Total bilirubin level in neonates with only 40μl serum or plasma sample. It determines total bilirubin by dual wavelength photometric analysis. Suited for pediatric setups, small workload labs & hospitals because of its compact and portable design. Advanced, benchtop and precise instrument for measuring Total Bilirubin.

Delivery & Availability:

Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock
The technical innovation of the iSED® fully-automated ESR analyzer consists of directly measuring the intensity of the red cell aggregation which is responsible for Erythrocyte Sedimentation Rate (ESR). Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock
  • Made of high quality PP material with good transparency.
  • Applied for Gilson/Finland/Eppendorf Pipettors.
  • Carefully inspect of raw material and manufactured under strict process check, all tips are with excellent accuracy and precison.
  • Special siliconizing on the inner surface ensure no liquid adhesion and accurate sample transfer.
  • Standard tips and filter tips can be autoclaved, high temperature sterilization acceptable.
Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Content

Purpose: PE-8000 extractor shall be used for extraction concentration of heavy metals, petroleum hydrocarbons, polyaromatic hydrocarbons, organochlorine compounds and other pollutants from water samples by any organic solvents in separating funnels, round-bottomed flasks and flat-bottomed flasks, with the IM9 fluoroplastic turbine stirrer used to create high-speed radial liquid flows to ensure effective mixing and uniform distribution of extraction agent throughout the sample volume. Extractor is provided with electronic stepless speed control unit. Extractor is provided with built-in control unit with large LCD. It is possible to set a timer.

Technical specifications: - Volume of stirred sample, L – 1.0 - Rotation speed of stirrer shaft, rpm - 100-3000 - Maximum torque, H-cm - 60 - Maximum diameter stirrer shaft, mm - 10 - Accuracy of speed maintenance, rpm, at least - ±20 - Stirrer material – PTFE and stainless steel - Stirrer type – turbine - Maximum power consumption, W – 100 - Power supply voltage (50 Hz), V - 220 ± 10 - Overall dimensions (with rack), mm - 420х380х800 - Weight, kg – 9

Scope of delivery:  1. Overhead stirrer PE-8300 - 1 pc. 2. ES-2720 rack for stirrers - 1 pc. 3. Clamp for fastening the stirrer on the rack – 1 pc. 4. Clamp for fastening holding ring on the rack – 1 pc. 5. Fluoroplastic turbine stirrer IM9 – 1 pc. 6. ТS-2 sealing unit made of fluoroplastic - 1 pc. 7. Holding ring – 1 pc. 8. Round separating funnel – 1 pc.

Alcohol Pad (70% Isopropyl Alcohol Pre Pad, Alcohol Cleansing Swab). Clean the required area. Discard after single use. Size and packing of Medical Alcohol pad:
  • Pad Size: Unfolded: 30 x 60 mm (other size can be request ).
  • Folded: 30x30 mm, 30 x 35mm,can be 2ply or 4ply ( other size, ply can be request ).
  • Aluminum Package: 60 x 50 mm , 50 x 50mm approximate ( other size can be request ).
  • Packing: 100/200 pcs per inner box, 50/ 100 boxes per carton(packing can be request).
Use of Medical Alcohol pad:
  • For cleaning prior to injection or to disinfect the hurted skin for family and medical treatment organization use.
  • For preparation and immediate disinfection of skin, wound area orr Instrument and utensil.
Notice of Medical Alcohol pad:
  • Not for eyes;
  • keep out of reach of children;
  • For external use only;
  • please stop using if you feel allergic or amyctic
Materials - Non-Woven Fabric
Trademark - OEM/ODM
Specification - CE&ISO13485
   
  • Total Volume: 60mL.
  • Specimen Container, Leak-proof, Ideal for Pathology/Histology/Cytology reagent pre-filling sample preparation.
  • Made of premium PP material, it is durable for usage.
  • Some measurements can be used to not only use urine samples, it can also be used for other liquids.
The advanced B111 Bilirubinmeter provides fast, accurate results for Total bilirubin level in neonates with only 40μl serum or plasma sample. It determines total bilirubin by dual wavelength photometric analysis. Suited for pediatric setups, small workload labs & hospitals because of its compact and portable design. Advanced, benchtop and precise instrument for measuring Total Bilirubin. Feature
  • Auto zero function: Manual blanking not required
  • Dual wavelength measurement system:
  • 2 wave lengths 455nm and 575nm
  • Plays major role to remove the interference caused due to Hemolysis & turbidity of sample
  • LED Light source:
  • LED does not require replacement as it lasts longer
  • As compared to Lamp, LED are more suitable as there is no intensity fluctuations
  • No warm up time required.
  • Flexible unit selection:
  • Two units either mg/dl or umol/L are selectable, ease of reporting
  • Compact slot for Capillary:
  • Accuracy of results are directly related to proper alignment of Capillary
  • B-111 has the easiest mode to ensure precise values
  • Data transfer:
  • External device can be connected to instrument through RS232 por
  • USB port
Technical Specification
  • Light source - LED
  • Wavelength - 455nm and 575nm
  • Net weight - 1kg
  • Measuring range - 0-30 mg/dl , 510 umol/L
  • Display - 16×2 LCD module with backlight
  • Auto calibration - Yes
  • Sample type - Serum or plasma
  • Sample volume - 40-80μL
  • Test time - <5sec
  • Units - mg/dl or umol/L
  • Dimensions - 150 (W) × 115 (H) × 190 (D) mm
  • Interface - RS232
  • Reading cuvette - Heparinized micro capillary holder
  • Storage temperature - 15-40°c
  • Power supply - DC 9V(DC adapter)
  • Power consumption - <2W
The technical innovation of the iSED® fully-automated ESR analyzer consists of directly measuring the intensity of the red cell aggregation which is responsible for Erythrocyte Sedimentation Rate (ESR). Unlike traditional ESR methodologies that measure the aggregation of the red blood cells indirectly, the iSED measures it directly and expresses the values in mm/hr. Features:
  • Results in 20 Seconds

  • 100µL sample drawn directly from primary EDTA tube

  • Fully automated, walk-away operation

  • Random access

  • Positive patient identification via internal barcode reader

  • Compatible with pediatric tube

     
Technical Specifications: 
Principle of Measure: Photometrical
Results: “Printed mm/hr, Range from 1-130 mm/hr”
Sample Requirements: 500uL whole blood, collected in EDTA anti-coagulant tested 24 hours from venipuncture at room temperature or refrigerated.
Tube Requirements: 13 x 75 mm, pierceable capped tube
Quality Control: Barcoded Seditrol® QC
Barcode Reader: Internal
Printer: Internal
Interface Specifications: serial RS232 port for LIS connection
Weight: 14 kg
Dimensions (H x W x D): 36 x 27 x 34 (cm) /14.3 x 10.5 x13.4 (in)
Voltage: 100-240VAC
Frequency Range: 50-60 Hz
Power: 160W
Click Here To Download Catalogue
  • Made of high quality PP material with good transparency.
  • Applied for Gilson/Finland/Eppendorf Pipettors.
  • Carefully inspect of raw material and manufactured under strict process check, all tips are with excellent accuracy and precison.
  • Special siliconizing on the inner surface ensure no liquid adhesion and accurate sample transfer.
  • Standard tips and filter tips can be autoclaved, high temperature sterilization acceptable.
  Classification: PIPETTE Brand Name: Vchanslab,Yingmed,OEM Model Number: YM-K7028 Place of Origin: China Product name: Pipette Tips Material: Polypropylene Certificate: CE/ISO13485/FDA Color: Natural, Blue, Yellow Application: Laboratory, Teaching, Hospital
WeightN/AN/AN/AN/AN/AN/A
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • Rating
  • Price
  • Description
Click outside to hide the comparison bar
Compare