Description | Shipped From Abroad
The Ready-Med HeartStart MRx IntelliVue 12-Pin 10-Lead EKG Trunk Cable (M1663A + M1968A) offers a durable, shielded connection for accurate cardiac monitoring. Compatible with Philips HeartStart MRx and IntelliVue systems, it features a 3.2-meter TPU-jacketed cable, AHA/IEC color-coded leads, and is CE and ISO13485 certified for clinical reliability.
Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| Shipped from Abroad
Electrocardiograph AsCARD Grey v.07.225 - is a 1, 3, 6, 12 channel ECG unit which enables to make electrocardiogram in full 12 leads. It is intended to conduct ECG examinations of adults and paediatric patients in all types of health care centres. ECG examination may be recorded in manual or automatic mode, with the possibility of analysis and interpretation. The device can be powered from 100 V ÷ 240 V mains supply or by an internal battery.
Delivery & Availability:
Typically 10 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | Shipped from Abroad
AsCARD Green electrocardiograph is a 1- and 3-channel ECG unit which enables to make electrocardiogram in full 12 leads. Intended for ECG examinations of adult and paediatric patients aimed at identification of cardiological abnormalities, myocardial ischaemia or infarction. The device is intended for use in healthcare facilities by duly trained personnel. ECG examination may be recorded in manual or automatic mode with the ability to perform the analysis and interpretation.
Delivery & Availability:
Typically 10 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | In Stock
The Classic III stethoscope brings new design, materials, and technology to the Littmann stethoscope series that’s been used and trusted by millions of medical professionals worldwide for decades. With a two-sided chestpiece, dual tunable diaphragms, improved tubing, and much more, the Classic III stethoscope combines the best of new and traditional.
Delivery & Availability:
Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | Shipped from Abroad
Ergometer CRG 200 is dedicated for Exercise Stress Tests System CardioTEST. The Ergometer has been designed according to modern technologies. It is controlled from PC equipped in CardioTEST software. Load level is controlled by a microprocessor, therefore it does not depend on speed, which in turn can be adjusted according to patient’s individual needs. Ergometer is equipped with ECG mode recording 12 standard leads.
Delivery & Availability:
Typically 21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | Shipped from Abroad
Bistos BT - 740 Patient Monitor: Bistos Patient Vital Signs Monitor, ECG, Resp., SpO2, NIBP, Temp., BT-740. The Bistos BT-740 is a multi-parameter patient monitor with an 8.4" TFT Color screen. The standard paramaters are ECG, respiratory, SpO2, NIBP and temperature. Additional options are EtCO2, IBP, Multi-gas, CO and Masimo SpO2. The BT-740 has a fanless design for quiet operation.
Delivery & Availability:
Typically 7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. |
Content | Features
-
Compatibility: Designed for Philips HeartStart MRx and IntelliVue monitors.
-
Connector: 12-pin round connector for seamless integration.
-
Lead Configuration: 10-lead (5+5) setup with AHA/IEC color-coded labels.
-
Cable Length: 3.2 meters for flexible patient monitoring.
-
Construction: Shielded cable with durable TPU jacket for enhanced longevity.
-
Certifications: CE and ISO13485 certified, ensuring compliance with medical standards..
-
Latex-Free: Safe for patients with latex sensitivities.
-
Use Case: Ideal for hospitals, clinics, and emergency medical services requiring reliable ECG monitoring.
|
Electrocardiograph AsCARD Grey v.07.225 - is a 1, 3, 6, 12 channel ECG unit which enables to make electrocardiogram in full 12 leads. It is intended to conduct ECG examinations of adults and paediatric patients in all types of health care centres. ECG examination may be recorded in manual or automatic mode, with the possibility of analysis and interpretation. The device can be powered from 100 V ÷ 240 V mains supply or by an internal battery.
Technical Specification:1. Visualisation of 1, 3, 6 or 12 ECG waveforms, analysis results and interpretations, examinations stored in memory.
2. Recording of 12 standard leads.
3. Print out in 1, 3, 6 or 12 ECG waveforms mode. Printing of a selected group:
- 1 channel - (I, II, III, aVR, aVL, aVF, V1, V2, V3, V4, V5, V6),
- 3 channels in standard format - (I-II-III, aVR-aVL-aVF, V1-V2-V3, V4-V5-V6),
- 3 channels in Cabrera format - (aVL-I-aVR, II-aVF-III, V1-V2-V3, V4-V5-V6),
- 6 channels in standard format - (I-II-III-aVR-aVL-aVF, V1-V2-V3-V4-V5-V6),
- 6 channels in Cabrera format - (aVL-I-aVR-II-aVF-III, V1-V2-V3-V4-V5-V6),
- 12 channels in standard format - (I-II-III-aVR-aVL-aVF-V1-V2-V3-V4-V5-V6),
- 12 channels in Cabrera format - (aVL-I-aVR-II-aVF-III-V1-V2-V3-V4-V5-V6).
4. Available types of examinations: manual, AUTO, SPIRO, automatic to clipboard, AUTOMANUAL, LONG (v.07.xx5).
5. Automatic record ECG signal from all 12 leads simultaneously, with save to temporary memory function, then depending on the settings:
print out examination's result, analysis, interpretation or save to database.
6. Adjustable length of automatic examination recording — interval of 6–30 seconds.
7. Reverse recording in automatic examination to clipboard and in manual examination (v.07.xx5).
8. Rhythm print out in AUTO examination and automatic examination to clipboard.
9. Definable stages of examination according to set up parameters in AUTOMANUAL examination.
10. Storing an examination in memory, 1–15 minutes in LONG mode (v.07.xx5).
11. ECG printed directly from the electrocardiograph using PCL5/6 printer.
12. Printout from database. Possibility to printout additional information about examination or patient.
13. Alpha-numerical soft-key keyboard with functional buttons.
14. Possibility to set parameters: speed, sensitive, intensity of printing.
15. Menu displayed on the screen for easy operation using touch panel.
16. Database of patients and examinations. Internal memory up to 1000 patients, 1000 examinations.
17. Viewing of the memory-stored examinations on display, with the possibility of changing the number of leads, augmentation and speed.
18. Automatic analysis and interpretation in compliance with EN 60601-2-51 (CSE database) - Analysis and interpretation dependable on age & sex of a patient.
19. Up to 130 automatic examinations in battery mode.
20. Continuous heart rate (HR) measurement and display.
21. Adapted to direct operation on an open heart.
22. Device allows to enable and disable the following filters:
- power line interference filter; filters available: 50 Hz, 60 Hz,
- muscle interference filter; filters available: 25 Hz, 35 Hz, 45 Hz,
- contour line filters; filters available: 0.15 Hz, 0.45 Hz, 0.75 Hz, 1.5 Hz,
- the low-pass filter (v.07.224, v.07.324, v.07.225, v.07.325): 75 Hz, 100 Hz, 125 Hz, 150 Hz,
- the auto-adaptive filter (v.07.224, v.07.324, v.07.225, v.07.325).
23. Detection of electrode detachment, independent for each channel (INOP control).
24. Detection of cardiac stimulator.
25. Sound signalling of detected stimulations of heart stimulator.
26. Protection against defibrillation pulse.
27. ECG recordings optionally saved on PenDrive, send on email or to other AsCARD via EKG-MAIL.
28. Wireless communication with the LAN or the Internet (v.07.3xx).
29. Wired communication with the LAN or the Internet.
30. Cooperation with CardioTEKA and CardioTEL.
31. Possibility of accepting orders for examination and sending back the results in HL7 standard via Internet (v.07.3xx).
32. Possibility of conducting preliminary spirometry examinations by using SPIRO-31 attachment.
33. EMR – keep performed examinations in specified period of time on external data storage (USB memory).
Accessories
1. Limb electrodes, 4 pieces (EKK type).
2. Chest electrodes, 6 pieces (EPP type).
3. KEKG 30R ECG cable.
4. Main cable.
5. R-A4 paper, 112 mm wide (1 reel).
6. ECG gel.
7. Operation manual.
| AsCARD Green electrocardiograph is a 1- and 3-channel ECG unit which enables to make electrocardiogram in full 12 leads. Intended for ECG examinations of adult and paediatric patients aimed at identification of cardiological abnormalities, myocardial ischaemia or infarction. The device is intended for use in healthcare facilities by duly trained personnel. ECG examination may be recorded in manual or automatic mode with the ability to perform the analysis and interpretation.
Electrocardiograph is based on advanced microprocessor technology. It is equipped with a thermal printer with high-resolution head and graphical LCD display. A hightech membrane keyboard makes the AsCARD Green device operation intuitive, and its menu navigation exceptionally easy. This light-weight, small-footprint and battery powered cause that device can be easily transported to any location. With plastic casing and foil covered keyboard, the device is neat and easy to clean.
Technical Specifications:
- dimensions: 220x153x55 mm (L x W x H)
- weight: < 0,6 kg
- recording of standard 12 ECG lead
- saving the ECG signal simultaneously from all the 12 leads during the automatic recording, together with the date and time of the examination, filter settings, examination recording time and, optionally, patient's data, in the internal memory
- printout of the automatic ECG recording from internal memory, in groups of three leads
- printout of the analysis, interpretation of automatic ECG examination
- display of 1, 3, 6 or 12 lead ECG recordings
- printout of 1 or 3 lead ECG of selected group:
- attaching the name of the patient to the ECG printout
- ECG printout in 1- or 3-channel modes
- membrane alphanumeric keyboard with functional keys
- graphical menu displayed on the screen for easy operation using keyboard
- automatic analysis and interpretation in compliance with EN 60601-2-25 (CSE database) - interpretation dependable on age & sex of a patient
- memory of the last automatic examinations, with a limit from 5 to 1000
- up to 130 automatic examinations in battery mode
- continuous heart rate (HR) measurement and display
- automatic detection of QRS complex
- adapted to direct operation on an open heart
- power line interference filter: 50 Hz, 60 Hz
- muscle interference filter; filters available: 25 Hz, 35 Hz, 45 Hz
- contour line filters; filters available: 0.15 Hz, 0.45 Hz, 0.75 Hz, 1.5 Hz
- detection of electrode detachment, independent for each channel
- selectable channel to detect heart rate
- the thickness of the printing ECG waveforms line to choose from: normal or bold
- presentation of the curves in the standard layout or Cabrera layout
- multilingual menu
- external USB communication port to connect a PC and the CardioTEKA software, for real-time transmission of ECG signal
- acoustic signalling of detected beats
- protection against defibrillation pulse
- detection and presentation of stimulating pulses on printout
- automatic examination with the printout of patient data and clinic data
- battery power saving functions
Standard Equipment:
- limb electrodes, 4 pieces
- chest electrodes, 6 piece
- KEKG-30R ECG cable
- medical power connector, M12-15
- RB1 paper 58 mm wide (1 roll)
- ECG gel
- operation manual
| The Classic III stethoscope brings new design, materials, and technology to the Littmann stethoscope series that’s been used and trusted by millions of medical professionals worldwide for decades. With a two-sided chestpiece, dual tunable diaphragms, improved tubing, and much more, the Classic III stethoscope combines the best of new and traditional.
Full adult and pediatric auscultation is available through its dual head chestpiece simply by rotating the central spline to alternate between the two sides. The more compact one piece diaphragm and rim assemblies have further increased acoustic sensitivity. The binaurals have been redesigned with larger diameter ear tubes and a thicker single lumen binaural to transfer sound more effectively. The selector spline is now recessed to allow a flush fit with the binaural tube and now features a visual indicator for easy identification of the operational diaphragm.
Features
- NEW: double-sided, dual diaphragm chestpiece for both adult and paediatric assessment.
- NEW: The paediatric side is also easily transformed into a traditional open bell by replacing the single-piece diaphragm with the supplied non-chill rim.
- NEW: chestpiece is precision-machined into an aesthetically pleasing, less angular shape.
- NEW: single-piece diaphragm instead of separate diaphragm/rim making it easier to attach and easier to clean due to the smooth unbroken surface.
- NEW: The stem features an open side indicator to easily identify which diaphragm is in operation.
- NEW: next-generation tubing gives even longer tube life with improved resistance to skin oils, alcohol and staining.
- 3M’s ‘Tunable Technology’ lets you easily switch from low to high frequency sounds by switching from light to firm pressure on both the adult and paediatric sides of the chestpiece.
- High acoustic sensitivity when performing general physical assessment.
- Laser engraving of text and symbols to personalise your scope and avoid theft/loss
- Larger ear tubes on the anatomically designed headset comfortably positioned for better sound transfer. Easy adjustment by simply squeezing or pulling apart the eartubes.
- Comfortable Snap-Tight soft seal eartips create an excellent acoustic seal to reduce ambient noise.
- No natural rubber latex or phthalate plasticisers are used in the tubing or any other component—to help protect health and the environment.
- Complement your personal style with Littmann’s large range of chestpiece finishes and tubing colours.
- Used as a diagnostic aid as part of the physical assessment of a patient.
| Ergometer CRG 200 is dedicated for Exercise Stress Tests System CardioTEST. The Ergometer has been designed according to modern technologies. It is controlled from PC equipped in CardioTEST software. Load level is controlled by a microprocessor, therefore it does not depend on speed, which in turn can be adjusted according to patient’s individual needs. Ergometer is equipped with ECG mode recording 12 standard leads.
Technical Specifications:
- Cooperation with the CardioTEST cardiovascular exercise system and AsTER cardiac rehabilitation system,
- Control using a computer through the RS-232 port,
- Braking: a processor-controlled brake with torque measurement,
- Load range: 25 - 1000 W,
- Speed range: 20 - 150 rpm,
- Load independent of the number of turns,
- Built-in ECG module,
- 12 standard leads in diagnostic mode,
- 2 leads in training mode,
- Sensitivity 2,5 / 5/10/20 mm / mV,
- Shift 25/50/100 mm / s,
- Digital filters 25 Hz, 35 Hz, 50 Hz, anti-frit filter,
- Digital filter of the isoelectric line,
- Measuring range HR 15-240 bpm,
- Maximum patient weight 200 kg,
- Power supply: 230 V, 50 Hz, 60VA,
- Dimensions: (LxWxH) 1190x600x1370 mm.
CardioTEST Software:
- excellent quality of ECG waveforms thanks to the use of digital filters eliminating the swimming of the isoelectric line and disruption of muscle origin,
- uninterrupted recording and presentation of 12-lead ECG signal,
- presentation of averaged P-QRS-T units with 12 leads along with the results of ST level and slope measurements,
- automatic HR measurement, ST level and ST segment slope,
- automatic control of cycloergometer and treadmill load,
- archiving and printing of the research report,
- automatic determination of measuring points with the possibility of manual correction,
- automatic arrhythmia analysis,
- presentation of parameters regarding: test phase, current load, stage time and total effort time,
- monitored parameters: rhythm rate, MET, double product, blood pressure, level, ST segment slope and load,
- real-time ECG printout,
- preview of trends of all measured parameters during the test,
- alarm system for monitored parameters and arrhythmia,
- an option to automatically measure blood pressure,
- archiving and printing a report enabling a reliable assessment of the study (such an report contains ECG, average P-QRS-T assemblies and a table with measurement results),
- standard test protocols and the ability to define your own protocols also in RAMP mode,
- preview the report on the screen before printing the report,
- function of reanalysis of the performed test,
- presentation of 3D trends illustrating ST segment changes.
| Bistos BT - 740 Patient Monitor: Bistos Patient Vital Signs Monitor, ECG, Resp., SpO2, NIBP, Temp., BT-740. The Bistos BT-740 is a multi-parameter patient monitor with an 8.4" TFT Color screen. The standard paramaters are ECG, respiratory, SpO2, NIBP and temperature. Additional options are EtCO2, IBP, Multi-gas, CO and Masimo SpO2. The BT-740 has a fanless design for quiet operation.
Features:
- 8.4" TFT Color Screen - (Optional Touch Screen Upgrade)
- Standard parameters are ECG, Resp., SpO2, NIBP, Temp.
- Ultra-low power consumption
- Quiet operation
- High accuracy SpO2 reading
- Data transfer or firmware upgrade via USB
- 2 Years Manufacturer's Warranty
Technical Specifications:
Model |
BT-740 |
Display |
8.4" Color TFT Screen |
ECG |
Lead type |
3/5 Lead |
Gain Selection |
x0.25, x0.5, x1, x2, x4, auto |
Sweep speed (mm/s) |
12.5, 25, 50 |
Bandwith:(Diagnostic Mode) |
0.05-130Hz |
Monitoring Mode |
0.5-40Hz |
Surgery Mode |
1-25Hz |
Strong Mode |
5-20Hz |
Heart Rate Range (bpm) |
Adult:15-300 |
Pediatric/neonate: 15-350 |
Respiration |
Method |
Trance-thoracic Impedance |
Measurement Range |
0-120rpm |
Sweep Speed (mm/s) |
6.25, 12.5, 25 |
SpO2 |
Measurement Range |
0-100% |
Accuracy (70-100%) |
Adult/Pediatric |
+/-2% |
Neonate |
+/-3% |
Accuracy (0-69%) |
Unspecified |
Perfusion Index |
0.05-20% |
Pulse Rate |
Range (bpm) |
25-250bpm |
NIBP** |
Method |
Automatic (Oscillometric) |
Operation Mode |
Manual/Auto/STAT |
Parameter |
Systolic, Diastolic, Mean |
Systolic Range (mmHg) |
Adult |
40-270 |
Pediatric |
40-200 |
Neonate |
40-130 |
Diastolic Range (mmHg) |
Adult |
10-210 |
Pediatric |
10-160 |
Neonate |
10-90 |
Mean Range (mmHg) |
Adult |
20-230 |
Pediatric |
20-175 |
Neonate |
20-100 |
Temperature |
Range |
0-50°C |
Parameter |
T1, T2 and TD |
IBP" |
Channel |
2 Channel, 4 Channel |
Range (mmHg) |
-50-400 |
Printer* |
Type |
Thermal dot array |
Print Speed (mm/s) |
12.5, 25, 50 |
Paper Size (mm) |
50 |
CO2* |
Sidestream |
Masimo ISA / Bistos |
Mainstream |
Masimo IRMA / Bistos |
Multi-gas O2* |
Masimo ISA |
SpO2 Masimo* |
Masimo SpO2 |
CO* |
Method |
Thermodilution |
Range |
0.2-20 L/min |
Battery |
Type (Capacity) |
Li-ion (440mAh) |
Run Time |
6 hour |
Charging Time |
4 hour |
Interface |
RJ45, USB, Nursing Call |
Warranty |
2 Years |
|
Reviews
There are no reviews yet.