Heating Mantle PE-4130 (2.0L) Digital
$0.00
Shipped From Abroad
Purpose: the heating mantle is intended for heating liquids in round-bottomed flasks made of heat-resistant glass with the volume of 2000 ml within the temperature range from the ambient one to 400°С
Delivery & Availability:
Typically 14-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Description
Purpose: the heating mantle is intended for heating liquids in round-bottomed flasks made of heat-resistant glass with the volume of 2000 ml within the temperature range from the ambient one to 400°С
Advantages:
– two-zone heating with the possibility of switching off the heating of the top zone
– heating element is made of safe fiberglass with nichrome wire which excludes permanent deformation and provides firm adherence to vessel walls to avoid heat losses and improve energy performance of the device
– indication of parameters on the liquid crystal display
– electronic (PID) temperature controller
– automatic and heating tuning of the heating intensity
– timer with visual and audible signaling of finishing of the heating
– locking of the control to provide the protection against accidental change of the operation mode
– possibility of connection of a remote sensor (option)
– determination and indication of the possible faults and malfunctions
– metal housing of the device is covered with powder paint KARUMEL which provides resistance to adhesion, scratching and corrosion
Remarks:
– the maximum heating temperature is reached when both heating zones are switched on
– due to presence of heat losses, the liquid temperature in the vessel can never reach the maximum temperature of the heating element; therefore, the settable temperature is limited by a value of 400°С
Technical specifications:
– Housing material: steel covered with powder paint resistant to chemical action
– Heating element: fabric fiberglass with nichrome wire
– Maximum heater temperature, °С – 450
– Flask volume, ml – 2000
– Weight, kg – 3.8
– Power supply voltage (50/60Hz), V – 220-230
– Power consumption, W – 470
Quick Comparison
Settings | Heating Mantle PE-4130 (2.0L) Digital remove | Alcohol Pad Per Pack remove | Test Strip for ApexBio HemoSmart Gold Hemoglobin Meter remove | 8 Bucket Centrifuge remove | ApexBio HemoSmart Gold Hemoglobin Meter remove | Avalun LabPad Device remove | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Name | Heating Mantle PE-4130 (2.0L) Digital remove | Alcohol Pad Per Pack remove | Test Strip for ApexBio HemoSmart Gold Hemoglobin Meter remove | 8 Bucket Centrifuge remove | ApexBio HemoSmart Gold Hemoglobin Meter remove | Avalun LabPad Device remove | ||||||||||||||
Image | ![]() | ![]() | ![]() | ![]() | ![]() | ![]() | ||||||||||||||
SKU | SF10335601093 | SF1033560084-64 | SF1033560084-30 | SF1033560084-114 | SF1033560084-29 | SF1033560084-65 | ||||||||||||||
Rating | ||||||||||||||||||||
Price |
| $4.25 | $9.50 | $72.50 | $55.00 |
| ||||||||||||||
Stock | ||||||||||||||||||||
Availability | ||||||||||||||||||||
Add to cart | ||||||||||||||||||||
Description | Shipped From Abroad
Purpose: the heating mantle is intended for heating liquids in round-bottomed flasks made of heat-resistant glass with the volume of 2000 ml within the temperature range from the ambient one to 400°С Delivery & Availability: Typically 14-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | In stock Alcohol Pad (70% Isopropyl Alcohol Pre Pad, Alcohol Cleansing Swab). Clean the required area. Discard after single use. Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | In Stock
Twenty Five (25) Test Strip per Pack
Delivery & Availability: Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | In stock
| In Stock
HemoSmart GOLD offers a fast and easy way to measure hemoglobin level and is the first biosensor-based palm sized hemoglobin testing system in the world.The one of its kind strip-based testing method offers ease of use and portability and requires only 1μL of blood.
Delivery & Availability: Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | In stock The coagulometer, LabPad® INR, measures blood coagulation time thanks to a patented optical technology. This portable In-Vitro Diagnostics (IVD) device works with the Tsmart® INR single-use microcuvettes. Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | ||||||||||||||
Content | Purpose: the heating mantle is intended for heating liquids in round-bottomed flasks made of heat-resistant glass with the volume of 2000 ml within the temperature range from the ambient one to 400°С Advantages: - two-zone heating with the possibility of switching off the heating of the top zone - heating element is made of safe fiberglass with nichrome wire which excludes permanent deformation and provides firm adherence to vessel walls to avoid heat losses and improve energy performance of the device - indication of parameters on the liquid crystal display - electronic (PID) temperature controller - automatic and heating tuning of the heating intensity - timer with visual and audible signaling of finishing of the heating - locking of the control to provide the protection against accidental change of the operation mode - possibility of connection of a remote sensor (option) - determination and indication of the possible faults and malfunctions - metal housing of the device is covered with powder paint KARUMEL which provides resistance to adhesion, scratching and corrosion Remarks: - the maximum heating temperature is reached when both heating zones are switched on - due to presence of heat losses, the liquid temperature in the vessel can never reach the maximum temperature of the heating element; therefore, the settable temperature is limited by a value of 400°С Technical specifications: - Housing material: steel covered with powder paint resistant to chemical action - Heating element: fabric fiberglass with nichrome wire - Maximum heater temperature, °С – 450 - Flask volume, ml – 2000 - Weight, kg – 3.8 - Power supply voltage (50/60Hz), V - 220-230 - Power consumption, W – 470 | Alcohol Pad (70% Isopropyl Alcohol Pre Pad, Alcohol Cleansing Swab). Clean the required area. Discard after single use.
Size and packing of Medical Alcohol pad:
Materials - Non-Woven Fabric
Trademark - OEM/ODM
Specification - CE&ISO13485
| Twenty Five (25) Test Strip per Pack | 800-1 electric centrifuge is widely used in hospitals, chemical and Biological Chemistry Laboratory for serum, plasma, immune qualitative analysis experiment. Has beautiful shape, large capacity, small volume, complete function. Its performance is stable, the speed is adjustable and can automatically adjust the balance, low temperature, high efficiency and wide applicability and advantages.
Technical Specifications:
Click Here To Download Catalogue | HemoSmart GOLD offers a fast and easy way to measure hemoglobin level and is the first biosensor-based palm sized hemoglobin testing system in the world.The one of its kind strip-based testing method offers ease of use and portability and requires only 1μL of blood.
Feature
Click Here To Download Catalogue | The coagulometer, LabPad® INR, measures blood coagulation time thanks to a patented optical technology. This portable In-Vitro Diagnostics (IVD) device works with the Tsmart® INR single-use microcuvettes.
Click Here To Download Catalogue | ||||||||||||||
Weight | N/A | N/A | N/A | N/A | N/A | N/A | ||||||||||||||
Dimensions | N/A | N/A | N/A | N/A | N/A | N/A | ||||||||||||||
Additional information |
Reviews
There are no reviews yet.