Description

Technical Advantages
  • Low temperature sterilization at 50℃±5℃, preserving delicate items without damage.
  • Green and pollution-free process using hydrogen peroxide solution, no toxic substances or pollution.
  • Stable sterilization with balanced temperature and stable hydrogen peroxide concentration.
  • Efficient design with rectangular sterilization chamber for increased loading capacity.
  • Safe and stable operation with electric lift door and safety interlock device.
  • Simple operation with intelligent control processor and one-key start.
  • Configured with high-quality components for reliable performance.
  • Time and cost-saving with short sterilization cycle and low operating costs.
  • Equipped with sterile filter for air inlet to prevent secondary pollution.
  • U disk storage function for storing and recording sterilization data.
Model Advantage
  • High-quality 5052 aluminum material for sterilization room, with excellent thermal conductivity.
  • ABS plastic disposable outer box material.
  • Aluminum alloy electrode mesh and sealing door material.
  • Upper and lower layers of aluminum alloy punching plates for loading sterilized items.
  • Electric lifting door with infrared sensor switch and door anti-pinch function.
  • Preheating heating time of ≤30 minutes.
  • Electric lifting door with infrared sensor switch and door anti-pinch function.
  • Preheating heating time of ≤30 minutes.
  • Full automatic control system with LCD touch screen display and PLC circuit design.
  • Micro-printer for printing and saving data during sterilization.
  • Siemens smart series PLC control system.
  • 7-inch color touch screen display with various status information.
  • Storage function for recording sterilization data.
  • Dedicated constant temperature incubator for biological indicator monitoring.
  • Built-in pressure and temperature sensors for precise control.
  • Two program options for circulation and rapid circulation.
  • Network connection port available.
  • Vacuum system with fast vacuum rate and long service life.
  • Oil mist filter and air filter for exhaust filtration.
  • Transistor control power supply for stable power output.
  • Cartridge filling method for hydrogen peroxide.
  • Explosion-proof flame retardant heating system.
  • Over-voltage and over-temperature protection functions.
Low Temp H₂O₂ Plasma Sterilizer Specifications:
Model ST-HT100P ST-HT130P ST-HT220P
Effective Volume 108L 135L 192L
Product Form Automatic door vertical
Heating Method Electric heating
Working Temperature 40-60 ℃
Select Sterilizer 58%-60% hydrogen peroxide (H2O2)
Sterilization Time 35-55 minutes
Installation Environment 10-40℃
Temperature Display LCD touch screen
Maximum Anti-stress Value 10pa
Operation Height ≤160cm
Voltage/Frequency(V/Hz) AC220V, 50Hz
Power 3.5KVA 4.2KVA 4.8KVA
Size(WxDxH) Internal (mm) 700x420x360 750x440x400 820x510x 460
External (mm) 1120x790x1770
Shipping Size (WxDxH)(mm) 1300x950x1950 1300x950x1950 1300x950x1950
N.W./G.W. (kg) 265/320 272/325 305/360

Reviews

There are no reviews yet.

Be the first to review “H₂O₂ Low Temperature Plasma Sterilizer”

Your email address will not be published. Required fields are marked *

Quick Comparison

SettingsH₂O₂ Low Temperature Plasma Sterilizer removeZenithlab (IB-9025A) Laboratory Incubator removeDiscover 14 Panel Cup with Adulterants Per Pack removeAlcohol Pad Per Pack removePlastic Urine Container Per Pack removeErma B-111 Bilirubin Meter remove
NameH₂O₂ Low Temperature Plasma Sterilizer removeZenithlab (IB-9025A) Laboratory Incubator removeDiscover 14 Panel Cup with Adulterants Per Pack removeAlcohol Pad Per Pack removePlastic Urine Container Per Pack removeErma B-111 Bilirubin Meter remove
ImageDrug Test Cup
SKUSF1033560130127-42SF1033560084-109SF1033560084-28SF1033560084-64SF1033560084-106SF1033560084-6
Rating
Price

$0.00

$350.00

$0.00

$4.25

$8.20

$715.00

Stock
Availability
Add to cart

DescriptionShipped From Abroad Low temperature hydrogen peroxide plasma sterilizers are used for sterilizing heat-sensitive medical devices, dental equipment, laboratory equipment, pharmaceuticals, veterinary instruments, and beauty industry tools. They provide safe and effective sterilization while preserving delicate material
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock
  • Microprocessor control.
  • Digital display setting and actual temperature.
  • Over temperature alarm, PID self-tuning.
  • Digital display running timer.
  • Stainless steel interior.
  • Electricity leakage protection.
  • With glass inner door, With hidden door locks.
  • Mechanical overheat protection, cut off the heating sources.
  • Automatic alarm after operation.
  • Suitable for constant temperature tests.
  • Suitable for bacteria cultivation, breeding, ferment.
Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock
The Discover Cup is an all-in-one drug of abuse test cup. The strips are self contained and the entire cup is tamper resistant. Delivery & Availability:
Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock Alcohol Pad (70% Isopropyl Alcohol Pre Pad, Alcohol Cleansing Swab). Clean the required area. Discard after single use. Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.In stock
  • Total Volume: 60mL.
  • Specimen Container, Leak-proof, Ideal for Pathology/Histology/Cytology reagent pre-filling sample preparation.
  • Made of premium PP material, it is durable for usage.
  • Some measurements can be used to not only use urine samples, it can also be used for other liquids.
Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Aboard  The advanced B111 Bilirubinmeter provides fast, accurate results for Total bilirubin level in neonates with only 40μl serum or plasma sample. It determines total bilirubin by dual wavelength photometric analysis. Suited for pediatric setups, small workload labs & hospitals because of its compact and portable design. Advanced, benchtop and precise instrument for measuring Total Bilirubin.

Delivery & Availability:

Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Content
Technical Advantages
  • Low temperature sterilization at 50℃±5℃, preserving delicate items without damage.
  • Green and pollution-free process using hydrogen peroxide solution, no toxic substances or pollution.
  • Stable sterilization with balanced temperature and stable hydrogen peroxide concentration.
  • Efficient design with rectangular sterilization chamber for increased loading capacity.
  • Safe and stable operation with electric lift door and safety interlock device.
  • Simple operation with intelligent control processor and one-key start.
  • Configured with high-quality components for reliable performance.
  • Time and cost-saving with short sterilization cycle and low operating costs.
  • Equipped with sterile filter for air inlet to prevent secondary pollution.
  • U disk storage function for storing and recording sterilization data.
Model Advantage
  • High-quality 5052 aluminum material for sterilization room, with excellent thermal conductivity.
  • ABS plastic disposable outer box material.
  • Aluminum alloy electrode mesh and sealing door material.
  • Upper and lower layers of aluminum alloy punching plates for loading sterilized items.
  • Electric lifting door with infrared sensor switch and door anti-pinch function.
  • Preheating heating time of ≤30 minutes.
  • Electric lifting door with infrared sensor switch and door anti-pinch function.
  • Preheating heating time of ≤30 minutes.
  • Full automatic control system with LCD touch screen display and PLC circuit design.
  • Micro-printer for printing and saving data during sterilization.
  • Siemens smart series PLC control system.
  • 7-inch color touch screen display with various status information.
  • Storage function for recording sterilization data.
  • Dedicated constant temperature incubator for biological indicator monitoring.
  • Built-in pressure and temperature sensors for precise control.
  • Two program options for circulation and rapid circulation.
  • Network connection port available.
  • Vacuum system with fast vacuum rate and long service life.
  • Oil mist filter and air filter for exhaust filtration.
  • Transistor control power supply for stable power output.
  • Cartridge filling method for hydrogen peroxide.
  • Explosion-proof flame retardant heating system.
  • Over-voltage and over-temperature protection functions.
Low Temp H₂O₂ Plasma Sterilizer Specifications:
Model ST-HT100P ST-HT130P ST-HT220P
Effective Volume 108L 135L 192L
Product Form Automatic door vertical
Heating Method Electric heating
Working Temperature 40-60 ℃
Select Sterilizer 58%-60% hydrogen peroxide (H2O2)
Sterilization Time 35-55 minutes
Installation Environment 10-40℃
Temperature Display LCD touch screen
Maximum Anti-stress Value 10pa
Operation Height ≤160cm
Voltage/Frequency(V/Hz) AC220V, 50Hz
Power 3.5KVA 4.2KVA 4.8KVA
Size(WxDxH) Internal (mm) 700x420x360 750x440x400 820x510x 460
External (mm) 1120x790x1770
Shipping Size (WxDxH)(mm) 1300x950x1950 1300x950x1950 1300x950x1950
N.W./G.W. (kg) 265/320 272/325 305/360
Features:
  • Microprocessor control.
  • Digital display setting and actual temperature.
  • Over temperature alarm, PID self-tuning.
  • Digital display running timer.
  • Stainless steel interior.
  • Electricity leakage protection.
  • With glass inner door, With hidden door locks.
  • Mechanical overheat protection, cut off the heating sources.
  • Automatic alarm after operation.
  • Suitable for constant temperature tests.
  • Suitable for bacteria cultivation, breeding, ferment.
  Technical Specification: Model: IB-9025A Working size: 250x250x250mm/9.84x9.84x9.84inch Power: 150W Temperature range: Room temperature+5~65℃ Temperature resolution: 0.1℃ Temperature fluctuation: ±0.5℃ Timer: 0-9999min Voltage: 110V 60Hz / 220V 50Hz Dimension: 380x370x580mm/14.96x14.57x22.83inch Size: 52cm*46cm*75cm / 20.5in*18.2in*29.6in Gross Weight:42kg / 93lb Net Weight: 23kg / 51lb Warranty: 1 year
All-in-One Design
FDA 510(K) & CLIA Waived Up to 99% accuracy rate Results in as little as 1 minute 24 Month Shelf Life from Date of Manufacture Secure, seal and send to lab for confirmation Built in temperature strip Available to test up to 17 substances with adulterants or 18 without adulterants Adulterants available
 
 
Alcohol Pad (70% Isopropyl Alcohol Pre Pad, Alcohol Cleansing Swab). Clean the required area. Discard after single use. Size and packing of Medical Alcohol pad:
  • Pad Size: Unfolded: 30 x 60 mm (other size can be request ).
  • Folded: 30x30 mm, 30 x 35mm,can be 2ply or 4ply ( other size, ply can be request ).
  • Aluminum Package: 60 x 50 mm , 50 x 50mm approximate ( other size can be request ).
  • Packing: 100/200 pcs per inner box, 50/ 100 boxes per carton(packing can be request).
Use of Medical Alcohol pad:
  • For cleaning prior to injection or to disinfect the hurted skin for family and medical treatment organization use.
  • For preparation and immediate disinfection of skin, wound area orr Instrument and utensil.
Notice of Medical Alcohol pad:
  • Not for eyes;
  • keep out of reach of children;
  • For external use only;
  • please stop using if you feel allergic or amyctic
Materials - Non-Woven Fabric
Trademark - OEM/ODM
Specification - CE&ISO13485
   
  • Total Volume: 60mL.
  • Specimen Container, Leak-proof, Ideal for Pathology/Histology/Cytology reagent pre-filling sample preparation.
  • Made of premium PP material, it is durable for usage.
  • Some measurements can be used to not only use urine samples, it can also be used for other liquids.
The advanced B111 Bilirubinmeter provides fast, accurate results for Total bilirubin level in neonates with only 40μl serum or plasma sample. It determines total bilirubin by dual wavelength photometric analysis. Suited for pediatric setups, small workload labs & hospitals because of its compact and portable design. Advanced, benchtop and precise instrument for measuring Total Bilirubin. Feature
  • Auto zero function: Manual blanking not required
  • Dual wavelength measurement system:
  • 2 wave lengths 455nm and 575nm
  • Plays major role to remove the interference caused due to Hemolysis & turbidity of sample
  • LED Light source:
  • LED does not require replacement as it lasts longer
  • As compared to Lamp, LED are more suitable as there is no intensity fluctuations
  • No warm up time required.
  • Flexible unit selection:
  • Two units either mg/dl or umol/L are selectable, ease of reporting
  • Compact slot for Capillary:
  • Accuracy of results are directly related to proper alignment of Capillary
  • B-111 has the easiest mode to ensure precise values
  • Data transfer:
  • External device can be connected to instrument through RS232 por
  • USB port
Technical Specification
  • Light source - LED
  • Wavelength - 455nm and 575nm
  • Net weight - 1kg
  • Measuring range - 0-30 mg/dl , 510 umol/L
  • Display - 16×2 LCD module with backlight
  • Auto calibration - Yes
  • Sample type - Serum or plasma
  • Sample volume - 40-80μL
  • Test time - <5sec
  • Units - mg/dl or umol/L
  • Dimensions - 150 (W) × 115 (H) × 190 (D) mm
  • Interface - RS232
  • Reading cuvette - Heparinized micro capillary holder
  • Storage temperature - 15-40°c
  • Power supply - DC 9V(DC adapter)
  • Power consumption - <2W
WeightN/AN/AN/AN/AN/AN/A
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • Rating
  • Price
  • Description
Click outside to hide the comparison bar
Compare