Internal Sidestream ETCO2 Sensor LH820
$0.00
Shipped From Abroad
LH820 is an internal plug-and-play sidestream ETCO2 sensor. It does not occupy any host space and connects to the host just with one eight-pin plug. Measuring respiration rate, ETCO2 concentration, inspired CO2 concentration. generally used in patient monitors and anesthetic machines. With a sampling rate low to 50 mL/min, it is ideal for use on adult, pediatric, and infant patients; patients undergoing procedural sedation; and short-term monitoring of intubated patients.
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Description
Features of Internal Sidestream ETCO2 Sensor LH820
- Suitable for incubated and non-incubated patients.
- Plug and play, long service life
- No calibration required
- Barometer pressure: CO2, N2O, HE compensation for accurate measurement
- Monitoring the patient’s real-time ETCO2, respiration rate, and inspired CO2
- Checking and confirming ET tube placement
- Detecting ventilator airway connection
- Fully compatible with Respironics module’s protocol
- Customized connector
Specifications of Internal Sidestream ETCO2 Sensor LH820
Principle | NDIR |
CO2 Measuring range | 0-150mmHg |
0 – 19.7 % | |
0 – 20 kPa | |
Accuracy | 0-40mmHg @ ±2% of reading, 41-70mmHg @ ±5% of reading, 71-100mmHg @ ±8% of reading, 101-150mmHg @ ±10% of reading. |
Respiration | 3 – 120 BPM; Accuracy: ±1 BPM |
Voltage & Power | 5.0VDC ±5%, 600mA (Sensor Average Power Consumption Less than 1.2W) |
Interface | RS232, TTL (customized) |
Temp & Humidity | Operating: 0º to 40°, 10 to 90% RH, |
Storage: -40º to 70ºC, <90% RH |
Compatible Brands:
![]() |
![]() |
|
![]() |
Philips | Nihon Kohden | Mindray | Biolight |
![]() |
![]() |
![]() |
![]() |
Bionet, Edan, Yonker, Infinium, DRE, Axia Surgical | Contec | Comen | Masimo |
Quick Comparison
Settings | Internal Sidestream ETCO2 Sensor LH820 remove | Spinal Epidural Pack remove | Hersill Genesis Anaesthetic Machine remove | Lab/Ward Coat remove | Elastomeric Pump (Disposable Infusion Pump) with PCA remove | Littman Stethoscope remove | |||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Name | Internal Sidestream ETCO2 Sensor LH820 remove | Spinal Epidural Pack remove | Hersill Genesis Anaesthetic Machine remove | Lab/Ward Coat remove | Elastomeric Pump (Disposable Infusion Pump) with PCA remove | Littman Stethoscope remove | |||||||||||||||||||||||||||||||||
Image | ![]() | ![]() | ![]() | ![]() | ![]() | ![]() | |||||||||||||||||||||||||||||||||
SKU | SF1033560084-25 | SF1033560450-1 | SF1033560084-222 | SF1033560084-18 | SF1033560084-5 | ||||||||||||||||||||||||||||||||||
Rating | |||||||||||||||||||||||||||||||||||||||
Price |
|
|
| $11.00 |
| $13.20 | |||||||||||||||||||||||||||||||||
Stock | |||||||||||||||||||||||||||||||||||||||
Availability | |||||||||||||||||||||||||||||||||||||||
Add to cart | |||||||||||||||||||||||||||||||||||||||
Description | Shipped From Abroad
LH820 is an internal plug-and-play sidestream ETCO2 sensor. It does not occupy any host space and connects to the host just with one eight-pin plug. Measuring respiration rate, ETCO2 concentration, inspired CO2 concentration. generally used in patient monitors and anesthetic machines. With a sampling rate low to 50 mL/min, it is ideal for use on adult, pediatric, and infant patients; patients undergoing procedural sedation; and short-term monitoring of intubated patients. Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| In Stock
It is for performing spinal/epidural or combined spinal/epidural or never-block loco-regional anaesthesia on patinet in clinical surgery.
Delivery & Availability: Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | Shipped from Abroad The Genesis anaesthesia workstations meet your most ambitious requirements. They stand out for their lung protective ventilation. Application Field: Neonates, Pediatrics & Adults Ventilation Modes: Volume controlled (VC), Pressure controlled (PC), Adaptive Pressure with Volume Guaranteed (APVG) & Pressure Support Ventilation (PSV) Delivery & Availability: Typically 21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | In stock
| In Stock
This product make the tension of silicon capsule as the driving force to control the flow by micro porous tube, it was pre-selected by doctor base on patients'situation, and then and then handed over to the patients ' self- management “to relieve or ease the pain
Delivery & Availability: Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | In Stock
Delivery & Availability: Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | |||||||||||||||||||||||||||||||||
Content | Features of Internal Sidestream ETCO2 Sensor LH820
Specifications of Internal Sidestream ETCO2 Sensor LH820
Compatible Brands:
| It is for performing spinal/epidural or combined spinal/epidural or never-block loco-regional anaesthesia on patinet in clinical surgery.
Component:
| The Genesis anaesthesia workstations meet your most ambitious requirements. They stand out for their lung protective ventilation, accuracy and performance, cost saving, design and ergonomics, safety and versatility.
TECHNICAL SPECIFICATION
OPERATING DATA
Click Here To Download Catalogue |
| This product make the tension of silicon capsule as the driving force to control the flow by micro porous tube, it was pre-selected by doctor base on patients'situation, and then and then handed over to the patients ' self- management “to relieve or ease the pain Product Components: one-way valve medicated device, elastic liquid storage device, liquid medicine filter, current limiting device, automatic liquid feeding device ( CBI & PCA ), pipe and the external connector; Product Features: 1. The continued to liquid (CBI) make the drug-stored sac mechanical stretch as a driving force, limited the flow through the micro porous tube to the patient safely, effectively, slightly, continuous uniform injection of liquid to analgesic effect; extrusion pump body does not affect the liquid normal velocity; liquid filtering device which can control the particles enter the body better; 2. Continued to liquid + self control to liquid ( CBI+PCA ) make the drug-stored sac mechanical stretch as a driving force, limited the flow through the micro porous tube to the patient safely, effectively, slightly, continuous uniform injection of liquid to analgesic effect; Automatic medicated function is the patients can medicate according to pain independently. Extrusion pump body does not affect the liquid normal velocity; liquid filtering device which can control the particles enter the body better; How to use: 1. Get analgesia pump out from sterile packaging, removing the cap of medicine inlet and outlet; pour the analgesic liquid in the liquid storage device, draw out the air from the liquid storage. 2. Finish medicating, waiting for the liquid outflow from the medicine outlet; please clamp tightly to stop flowing for preparation. 3. Control keys (PCA key) is a function key to add the medicine base on continue to medicated by patients' self-controlled. So the patients can self-control the PCA key under the guidance of doctors, according to the needs while they are in treatment. At the same time, doctor should fill in PCA treatment card, so that they can analyze the condition from PCA additional times. | Littman Stethoscope Features:
| |||||||||||||||||||||||||||||||||
Weight | N/A | N/A | N/A | N/A | N/A | N/A | |||||||||||||||||||||||||||||||||
Dimensions | N/A | N/A | N/A | N/A | N/A | N/A | |||||||||||||||||||||||||||||||||
Additional information |
Reviews
There are no reviews yet.