Internal Sidestream ETCO2 Sensor LH820

$0.00

Shipped From Abroad

LH820 is an internal plug-and-play sidestream ETCO2 sensor. It does not occupy any host space and connects to the host just with one eight-pin plug. Measuring respiration rate, ETCO2 concentration, inspired CO2 concentration. generally used in patient monitors and anesthetic machines. With a sampling rate low to 50 mL/min, it is ideal for use on adult, pediatric, and infant patients; patients undergoing procedural sedation; and short-term monitoring of intubated patients.

Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Brands:: Prior-care

Description

Features of Internal Sidestream ETCO2 Sensor LH820
  • Suitable for incubated and non-incubated patients.
  • Plug and play, long service life
  • No calibration required
  • Barometer pressure: CO2, N2O, HE compensation for accurate measurement
  • Monitoring the patient’s real-time ETCO2, respiration rate, and inspired CO2
  • Checking and confirming ET tube placement
  • Detecting ventilator airway connection
  • Fully compatible with Respironics module’s protocol
  • Customized connector

 

Specifications of Internal Sidestream ETCO2 Sensor LH820
Principle NDIR
CO2 Measuring range 0-150mmHg
0  –  19.7 %
0  –  20 kPa
Accuracy 0-40mmHg @ ±2% of reading,
41-70mmHg @ ±5% of reading,
71-100mmHg @ ±8% of reading,
101-150mmHg @ ±10% of reading.
Respiration 3 – 120 BPM; Accuracy: ±1 BPM
Voltage & Power 5.0VDC ±5%, 600mA (Sensor Average Power Consumption Less than 1.2W)
Interface RS232, TTL (customized)
Temp & Humidity Operating: 0º to 40°, 10 to 90% RH,
Storage: -40º to 70ºC, <90% RH

 

Compatible Brands:
 

 

Philips Nihon Kohden Mindray Biolight
Bionet, Edan, Yonker, Infinium, DRE, Axia Surgical Contec Comen Masimo

Reviews

There are no reviews yet.

Be the first to review “Internal Sidestream ETCO2 Sensor LH820”

Your email address will not be published. Required fields are marked *

Quick Comparison

SettingsInternal Sidestream ETCO2 Sensor LH820 removeSpinal Epidural Pack removeHersill Genesis Anaesthetic Machine removeLab/Ward Coat removeElastomeric Pump (Disposable Infusion Pump) with PCA removeLittman Stethoscope remove
NameInternal Sidestream ETCO2 Sensor LH820 removeSpinal Epidural Pack removeHersill Genesis Anaesthetic Machine removeLab/Ward Coat removeElastomeric Pump (Disposable Infusion Pump) with PCA removeLittman Stethoscope remove
ImageHersill Genesis Anaesthetic MachineLittman Stethoscope
SKUSF1033560084-25SF1033560450-1SF1033560084-222SF1033560084-18SF1033560084-5
Rating
Price

$0.00

$0.00

$0.00

$11.00

$0.00

$13.20

Stock
Availability
Add to cart

DescriptionShipped From Abroad

LH820 is an internal plug-and-play sidestream ETCO2 sensor. It does not occupy any host space and connects to the host just with one eight-pin plug. Measuring respiration rate, ETCO2 concentration, inspired CO2 concentration. generally used in patient monitors and anesthetic machines. With a sampling rate low to 50 mL/min, it is ideal for use on adult, pediatric, and infant patients; patients undergoing procedural sedation; and short-term monitoring of intubated patients.

Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In Stock It is for performing spinal/epidural or combined spinal/epidural or never-block loco-regional anaesthesia on patinet in clinical surgery.

Delivery & Availability:

Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped from Abroad The Genesis anaesthesia workstations meet your most ambitious requirements. They stand out for their lung protective ventilation. Application Field: Neonates, Pediatrics & Adults Ventilation Modes: Volume controlled (VC), Pressure controlled (PC), Adaptive Pressure with Volume Guaranteed (APVG) & Pressure Support Ventilation (PSV) Delivery & Availability: Typically 21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.In stock
  • This white coat laboratory coat is a knee-length overcoat/smock is perfect for professionals in the medical field or by those involved in laboratory work.
  • This garment is Easy to wash and made from a cotton polyester blend, allowing it to be washed at high temperature and make it easy to see if it is clean.
  • Easy to wash.
Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In Stock This product make the tension of silicon capsule as the driving force to control the flow by micro porous tube, it was pre-selected by doctor base on patients'situation, and then and then handed over to the patients ' self- management “to relieve or ease the pain

Delivery & Availability:

Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In Stock
  • Monitor and assess a wide range of patients
  • Detect normal and abnormal sounds and rhythms
  • Useful in non-critical care environments such as a medical office, general ward, OB/GYN, ambulatory clinic or urgent care

Delivery & Availability:

Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Content
Features of Internal Sidestream ETCO2 Sensor LH820
  • Suitable for incubated and non-incubated patients.
  • Plug and play, long service life
  • No calibration required
  • Barometer pressure: CO2, N2O, HE compensation for accurate measurement
  • Monitoring the patient’s real-time ETCO2, respiration rate, and inspired CO2
  • Checking and confirming ET tube placement
  • Detecting ventilator airway connection
  • Fully compatible with Respironics module's protocol
  • Customized connector
 
Specifications of Internal Sidestream ETCO2 Sensor LH820
Principle NDIR
CO2 Measuring range 0-150mmHg
0  –  19.7 %
0  –  20 kPa
Accuracy 0-40mmHg @ ±2% of reading, 41-70mmHg @ ±5% of reading, 71-100mmHg @ ±8% of reading, 101-150mmHg @ ±10% of reading.
Respiration 3 – 120 BPM; Accuracy: ±1 BPM
Voltage & Power 5.0VDC ±5%, 600mA (Sensor Average Power Consumption Less than 1.2W)
Interface RS232, TTL (customized)
Temp & Humidity Operating: 0º to 40°, 10 to 90% RH,
Storage: -40º to 70ºC, <90% RH
 
Compatible Brands:
 

 
Philips Nihon Kohden Mindray Biolight
Bionet, Edan, Yonker, Infinium, DRE, Axia Surgical Contec Comen Masimo
It is for performing spinal/epidural or combined spinal/epidural or never-block loco-regional anaesthesia on patinet in clinical surgery. Component:
  • Epidural needle 16G,
  • Epidural catheter,
  • Epidural filter 0.2 um,
  • Catheter connector,
  • LOR syringe
The Genesis anaesthesia workstations meet your most ambitious requirements. They stand out for their lung protective ventilation, accuracy and performance, cost saving, design and ergonomics, safety and versatility.   TECHNICAL SPECIFICATION OPERATING DATA
  • Weight - 105 kg
  • Dimensions - 92 cm Wide x 68 cm Deep x 139 cm High (93 cm to the table surface)
  • Packaging Dimensions - 105 cm Wide x 75 cm Deep x 160 cm High
  • Operating voltage supply - 110 to 240 V~, 47 to 63 Hz (12 to 6 A)
  • Power input - 120 W typically (max. 1.2 kW with auxiliary outlets used)
  • Battery autonomy - 90 min typically
  • Auxiliary power outlets - 4, with automatic protection
  • O2, N2O and Air supply - 2.7 to 6.9 bar (39.1 to 100 psi)
  • Screen - TFT 18.5" (47 cm) projected capacitive touchscreen
  • Protection class - Class I, gas analyser type BF defibrillation proof
  • Classification - Class II b
  • Storage - One front drawer with self-brake system and two back cabinets with door
  • Lighting - LED bar below the screen controlled from the touchscreen
  • Auxiliary integrated systems - Auxiliary 02 flow meter (0-15 L/min), Auxiliary 02 suppy valve (NF standard) and Suction device
  • Communication ports - 1 x RS-232, 2 x USB, 1 x LAN Ethernet
Fresh Gases (02, N20 and Air, electronically controlled)
  • Fresh gas flow - 0 and 0.1 to 18 L/min 02/N20/Air
  • Accuracy - 0.1 to 0.5 L/min = ±0.05 L/min; 0.5 to 18 L/min = ±10 %
  • 02 concentration - 21 to 100% vol. with Air, 25 to 100% with N20 (minimum 200 ml/min 02)
  • 02 Safety fresh gas (backup) - 0-0.2-0.4-0.7-1-1.5- 2- 3- 4- 6- 8-10-12-15 L/min 02
  • 02 flush (+02) - 40 L/min standard (adjustable 25 - 75 L/min upon requirement)
Breathing System (CABS)
  • Autoclavable - 134 °C
  • Weight of breathing system - 9.8 kg
  • C02 absorber volume - 1.5 L
  • Leakage - < 150 mL/min (at 30 hPa)
  • Pressure limiting valve APL - 0 to 70 hPa
  • Pressure relief valve - 125 hPa
  • Vacuum safety valve - 0.3 hPa
  • resistance at 60L/min - 5.80 hPa
  • resistance at 60L/min - 2.90 hPa
  • resistance at 30L/min - 3.55 hPa
  • resistance at 30L/min - 0.89 hPa
  • Internal Compliance at 30 hPa - 15 mL
  VENTILATOR Operation / Ventilation Modes Volume controlled (VC) modes:
  • Volume Controlled Ventilation (VCV)
  • VC Synchronized Intermittent Mandatory Ventilation (VC-SIMV)
  • VC-SIMV with Pressure Support (VC-SIMV-PS) *
Pressure controlled (PC) modes:
  • Pressure Controlled Ventilation (PCV)
  • PC Synchronized Intermittent Mandatory (PC-SIMV)
  • PC-SIMV with Pressure Support (PC-SIMV-PS) *
Adaptive Pressure with Volume Guaranteed (APVG) modes (other trade names: Autoflow,PCVR, PRVC, AVAPS, VC+)
  • Adaptive Pressure with Volume Guaranteed (APVG) *
  • APVG Synchronized Intermittent Mandatory (APVG-SIMV) *
  • APVG -SIMV with Pressure Support (APVG-SIMV-PS) *
Pressure Support Ventilation (PSV) *
  • (other trade names: PS, ASB, SPS, IPS)
  Non-mechanical Operation / Ventilation Modes
  • Manual ventilation through the CABS system (Auto/Manual software controlled)
  • Spontaneous ventilation either through the bellows (auto mode) or through the bag
  • (manual mode) Manual ventilation through the external fresh gas outlet for non-rebreathing systems (Bain, Mapleson, ...)
Application field: Neonates, Pediatrics & Adults
  • Tidal volume - 5 to 1500 mL
  • Inspiratory pressure - 0 to 68 hPa
  • Ventilation frequency ­- 3 to 120/min
  • Inspiratory time - 0.05 to 16.6s
  • l:E ratio - 5:1 to 1:8
  • Inspiratory pause - 0 to 60%
  • Inspiratory flow - max. 150 L/min
  • PEEP - 0 to 30 hPa
  • Flow trigger - 0.2 to 15 L/min
  • Pressure support - 5 to 50 hPa
  • Ramp time - 0.1 to 2 s
  • Maximum pressure - 0 to 68 hPa
  MONITORING
  • 5" (47 cm) projected capacitive touchscreen, supported on a 360° rotating and 2 axis tilting arm.
  • Measurements displayed: Peak pressure; Plateau pressure; Mean pressure; Expiratory minute ventilation; Expiratory tidal volume; Inspiratory tidal volume; Expiratory volumeter; Breathing rate; Compliance and Resistance (in VC modes); Patient info (age, weight, MAC, Class ASA); Connected sensors; Battery status; Power supply status; Gases supply pressures for 02, N20 and Air; Inspiratory and expiratory concentration of 02, N20, C02 and Anaesthetic gas*
  • Parametres charted as curves (up to 3 simultaneously): Airway pressure; Expiratory flow; Inspiratory flow; Volume; Fresh gases (Rotstyle); Concentration of 02, N20, C02 and Anaesthetic gas*; Trends: Minute volume, MAC and gases (02, N20, C02 and Anaesthetic gas).
  • Display for the performance of the hospital Anaesthetic Gas Scavenging System (AGSS).
  • Configurable interface: bright/dark, multi-language.
  • Loops (up to 2 simultaneously): Volume-Pressure, Flow-Volume, Pressure-Flow, C02-Volume.
  • Fresh gas virtual rotameters for 02, N20, Air. * C02, N20 and Anaesthetic gas monitoring with the accessory multigas analyzer main-stream or side-stream; 02 real-time monitoring via paramagnetic
 
Click Here To Download Catalogue
  • This white coat laboratory coat is a knee-length overcoat/smock is perfect for professionals in the medical field or by those involved in laboratory work.
  • This garment is Easy to wash and made from a cotton polyester blend, allowing it to be washed at high temperature and make it easy to see if it is clean.
  • Easy to wash.
This product make the tension of silicon capsule as the driving force to control the flow by micro porous tube, it was pre-selected by doctor base on patients'situation, and then and then handed over to the patients ' self- management “to relieve or ease the pain Product Components: one-way valve medicated device, elastic liquid storage device, liquid medicine filter, current limiting device, automatic liquid feeding device ( CBI & PCA ), pipe and the external connector; Product Features: 1. The continued to liquid (CBI) make the drug-stored sac mechanical stretch as a driving force, limited the flow through the micro porous tube to the patient safely, effectively, slightly, continuous uniform injection of liquid to analgesic effect; extrusion pump body does not affect the liquid normal velocity; liquid filtering device which can control the particles enter the body better; 2. Continued to liquid + self control to liquid ( CBI+PCA ) make the drug-stored sac mechanical stretch as a driving force, limited the flow through the micro porous tube to the patient safely, effectively, slightly, continuous uniform injection of liquid to analgesic effect; Automatic medicated function is the patients can medicate according to pain independently. Extrusion pump body does not affect the liquid normal velocity; liquid filtering device which can control the particles enter the body better; How to use: 1. Get analgesia pump out from sterile packaging, removing the cap of medicine inlet and outlet; pour the analgesic liquid in the liquid storage device, draw out the air from the liquid storage. 2. Finish medicating, waiting for the liquid outflow from the medicine outlet; please clamp tightly to stop flowing for preparation. 3. Control keys (PCA key) is a function key to add the medicine base on continue to medicated by patients' self-controlled. So the patients can self-control the PCA key under the guidance of doctors, according to the needs while they are in treatment. At the same time, doctor should fill in PCA treatment card, so that they can analyze the condition from PCA additional times.Littman Stethoscope Features:
  • Monitor and assess a wide range of patients
  • Detect normal and abnormal sounds and rhythms
  • Useful in non-critical care environments such as a medical office, general ward, OB/GYN, ambulatory clinic or urgent care
  • Fun and vibrant; match colour and finish to your personality
  • Designed for use with adult and pediatric patients
  • tunable, dual-sided stainless steel chest piece with open or closed bell
  • Non-chill bell sleeve for greater patient comfort
  • Soft-sealing ear-tips provide optimal comfort and excellent sound occlusion
  • Made in the USA without natural rubber latex

WeightN/AN/AN/AN/AN/AN/A
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • Rating
  • Price
  • Description
Click outside to hide the comparison bar
Compare