KEDEE KD-2260 Manual Rotary Microtome

$2,970.00

Ship From Abroad

The Microtome KD-2260 is designed to meet multiple requirements of histology or histopathology labs. It is also suitable for the use in research labs as well as industrial quality assurance. In being manual, the Microtome KD-2260 is flexible to use at any place in the laboratory.

Delivery & Availability:
Typically 14-21 Working Days – excluding furniture and heavy/bulky equipment. Please contact us for further information.

SF10335601250
Brands:: Kedee

Description

The Microtome KD-2260 is designed to meet multiple requirements of histology or histopathology labs. It is also suitable for the use in research labs as well as industrial quality assurance. In being manual, the Microtome KD-2260 is flexible to use at any place in the laboratory. With its high-precision mechanics inside, the Microtome KD-2260 permits quality sections, while maintaining a high, consistent throughput. Great functionality and the appealing design are the key features of our microtome. Optimal user comfort enables a rapid, safe and smooth sectioning, even under heavy workload. The integrated sectioning waste tray is resistant to xylene, and can be detached for cleaning.

Technical Specifications:

  • Section Thickness Setting Range: 0–60μm
  • Section thickness settingoptions:

     0–2μm       increment 0.25μm

     2–10μm       increment 1μm

    10–20μm      increment 2μm

    20–60μm      increment 5μm

  • Trimming Thickness Setting Range: 0- 60μm
  • Minimum Setting of Sectioning Thickness: 1μm
  • Total Horizontal Specimen Feed:29mm;
  • Vertical Specimen Stroke:60mm
  • Movement Range of the Base of BladeHolder Base: 0-60mm (front to back)
  • Movement Range of the Blade Press plate: 0-23mm
  • Specimen Holder Rotation: at any angle within360 degrees
  • Maximum Specimen Size: 60×70mm
  • Specimen Orientation:XY – 8°
  • Precision Error: ±1%
  • Dimensions: 570×440×290mm (W×D×H)
  • Net weight: 28kg

Review(1)

5.00 average based on 1 ratings.
  1. Meshack shiundu

    Hello,please email me the operation manual for this brand.Thanks

Add a review

Your email address will not be published. Required fields are marked *

Quick Comparison

SettingsKEDEE KD-2260 Manual Rotary Microtome removePlastic Urine Container Per Pack removeAvalun 48 INR Microcuvette removeSkyla Hi POC Clinical Chemistry Analyzer remove8 Bucket Centrifuge removeAvalun LabPad Device remove
NameKEDEE KD-2260 Manual Rotary Microtome removePlastic Urine Container Per Pack removeAvalun 48 INR Microcuvette removeSkyla Hi POC Clinical Chemistry Analyzer remove8 Bucket Centrifuge removeAvalun LabPad Device remove
ImageAvalun 48 INR MicrocuvetteAvalun Labpad machine
SKUSF10335601250SF1033560084-106SF1033560084-74SF1033560060-2SF1033560084-114SF1033560084-65
Rating
Price

$2,970.00

$8.20

$0.00

$0.00

$72.50

$0.00

Stock

Out of stock

AvailabilityOut of stock
Add to cart

DescriptionShip From Abroad

The Microtome KD-2260 is designed to meet multiple requirements of histology or histopathology labs. It is also suitable for the use in research labs as well as industrial quality assurance. In being manual, the Microtome KD-2260 is flexible to use at any place in the laboratory.

Delivery & Availability: Typically 14-21 Working Days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock
  • Total Volume: 60mL.
  • Specimen Container, Leak-proof, Ideal for Pathology/Histology/Cytology reagent pre-filling sample preparation.
  • Made of premium PP material, it is durable for usage.
  • Some measurements can be used to not only use urine samples, it can also be used for other liquids.
Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Out stock LabPad®’s versatility comes especially from its Tsmart® single-use microcuvette, which contains a lyophilized reagent specific to each test. The Tsmart® microcuvette is the fruit of numerous innovations that have led to many benefits for users. Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.Shipped from Abroad The skyla Hi POC Clinical Chemistry Analyzer provides clinical testing laboratories of medical facilities and clinics with an in-vitro clinical chemistry diagnostic tool that is compact, portable, and reports rapid results.The use of skyla Hi in the management of diabetes enables better access to testing and rapid clinical decision making, discussion,and implementation of optimized treatment. Delivery & Availability: Typically 14 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.In stock
Classification: Laboratory Centrifuge
Brand Name: xiangtian
Model Number: 800-1
Place of Origin: Jiangsu, China
Time range: 0-60min
Max speed: 4000r/min
Max RCF: 1790xg
Capacity: 20ml*6
  Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock The coagulometer, LabPad® INR, measures blood coagulation time thanks to a patented optical technology. This portable In-Vitro Diagnostics (IVD) device works with the Tsmart® INR single-use microcuvettes. Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
ContentThe Microtome KD-2260 is designed to meet multiple requirements of histology or histopathology labs. It is also suitable for the use in research labs as well as industrial quality assurance. In being manual, the Microtome KD-2260 is flexible to use at any place in the laboratory. With its high-precision mechanics inside, the Microtome KD-2260 permits quality sections, while maintaining a high, consistent throughput. Great functionality and the appealing design are the key features of our microtome. Optimal user comfort enables a rapid, safe and smooth sectioning, even under heavy workload. The integrated sectioning waste tray is resistant to xylene, and can be detached for cleaning. Technical Specifications:
  • Section Thickness Setting Range: 0–60μm
  • Section thickness settingoptions:
     0–2μm       increment 0.25μm      2–10μm       increment 1μm     10–20μm      increment 2μm     20–60μm      increment 5μm
  • Trimming Thickness Setting Range: 0- 60μm
  • Minimum Setting of Sectioning Thickness: 1μm
  • Total Horizontal Specimen Feed:29mm;
  • Vertical Specimen Stroke:60mm
  • Movement Range of the Base of BladeHolder Base: 0-60mm (front to back)
  • Movement Range of the Blade Press plate: 0-23mm
  • Specimen Holder Rotation: at any angle within360 degrees
  • Maximum Specimen Size: 60×70mm
  • Specimen Orientation:XY – 8°
  • Precision Error: ±1%
  • Dimensions: 570×440×290mm (W×D×H)
  • Net weight: 28kg
  • Total Volume: 60mL.
  • Specimen Container, Leak-proof, Ideal for Pathology/Histology/Cytology reagent pre-filling sample preparation.
  • Made of premium PP material, it is durable for usage.
  • Some measurements can be used to not only use urine samples, it can also be used for other liquids.
LabPad®’s versatility comes especially from its Tsmart® single-use microcuvette, which contains a lyophilized reagent specific to each test. The Tsmart® microcuvette is the fruit of numerous innovations that have led to many benefits for users.
Features:
  • Fully automated "plug-and-play"   behavior
  • Reduced blood volume (only 3µL)
  • A large space for blood drop-off
  • Fills up quickly, using just capillarity
  • Easy handling, thanks to its 3D shape
  • Optimized preservation in individual pouches, in boxes of 12, 24, or 48 units
skyla Hi Analyzer enables better access to testing and rapid clinical decision making, discussion, and implementation of optimized treatment. To get the result, only prepare <1 μl fingertips blood or venous blood (depends on test item) without pretreatment with easy steps and then read the result after 6 mins. The device allows two specimens be tested in one run and provides fully automatic procedures from checking the validity of cartridge to printing the results. Reagent Kit
  • HbA1C
  • CRP
  • Lipid Panel (TC,TG, HDL, LDL#)
  • Lipid Plus Panel (Glu,TC,TG, HDL, LDL#)
Main Specification
Principle
Turbidimetric Method / Biochemistry
Device
Testing Time
5~20 minutes (depends on test items)
Display and Interface
5″ TFT color touch screen LCD
Memory Capacity
50,000 test results
Dimension of Analyzer
270 x 188 x 148 mm
Weight of Analyzer
1.7 kg
Dimension of Printer Module
134 x 100 x 82.7 mm
Weight of Printer Module
0.37 kg
Power Supply
100~240 volts AC, 50-60Hz
Data Transmission
USB 2.0*4 / USB 3.0*1 / RS232*1 / RJ45*1 / Wi-Fi (optional)
Reagent and Samples
Samples
Fingertips blood or venous blood
Samples Volume
0.8 ~ 30 μL (depends on test item)
Storage Temperature (Reagent)
2 ~ 8˚C
Humidity
Relative humidity < 95% (Non-condensing)
Temperature
10 ~ 32 ˚C
Click Here To Download Catalogue
800-1  electric centrifuge is widely used in hospitals, chemical and Biological Chemistry Laboratory for serum, plasma, immune qualitative analysis experiment. Has beautiful shape, large capacity, small volume, complete function. Its performance is stable, the speed is adjustable and can automatically adjust the balance, low temperature, high efficiency and wide applicability and advantages. Technical Specifications:
Type No.
800-1
Power  source
220V 50HZ     110V  60HZ
Speed Range (rpm)
0~4000(rpm)
Time Range(min)
0-60min
Capacity (ml)
20(ml)×6
Maximum centrifugal force(xg)
1790(xg)
Package Size (cm)
29*29*26
 
Click Here To Download Catalogue
The coagulometer, LabPad® INR, measures blood coagulation time thanks to a patented optical technology. This portable In-Vitro Diagnostics (IVD) device works with the Tsmart® INR single-use microcuvettes.
  • User-friendly: the LabPad® INR is designed to be easy to use especially thanks to its 3D-shaped microcuvette that only requires a small drop of blood from a fingertip. Thanks to the color screen, both measurement steps and browsing the list of results are easy to visualize.
  • Quick and reliable: the reliability of INR results is obtained by quality controls that are performed automatically before each measurement. In less than one minute, you can see if you are in your therapeutic range.
  • Connected: the result obtained after performing the test can be transferred to healthcare professionals in charge of your treatment monitoring. This result is complementary to the pie charts and trend reports directly displayed on the LabPad® INR to help you monitoring your treatment
 
Click Here To Download Catalogue
   
WeightN/AN/AN/AN/AN/AN/A
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • Rating
  • Price
  • Description
Click outside to hide the comparison bar
Compare