KEDEE KD-2260 Manual Rotary Microtome
Ask for Price$0.00
Ship From Abroad
The Microtome KD-2260 is designed to meet multiple requirements of histology or histopathology labs. It is also suitable for the use in research labs as well as industrial quality assurance. In being manual, the Microtome KD-2260 is flexible to use at any place in the laboratory.
Delivery & Availability:
Typically 14-21 Working Days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Description
The Microtome KD-2260 is designed to meet multiple requirements of histology or histopathology labs. It is also suitable for the use in research labs as well as industrial quality assurance. In being manual, the Microtome KD-2260 is flexible to use at any place in the laboratory. With its high-precision mechanics inside, the Microtome KD-2260 permits quality sections, while maintaining a high, consistent throughput. Great functionality and the appealing design are the key features of our microtome. Optimal user comfort enables a rapid, safe and smooth sectioning, even under heavy workload. The integrated sectioning waste tray is resistant to xylene, and can be detached for cleaning.
Technical Specifications:
- Section Thickness Setting Range: 0–60μm
- Section thickness settingoptions:
0–2μm increment 0.25μm
2–10μm increment 1μm
10–20μm increment 2μm
20–60μm increment 5μm
- Trimming Thickness Setting Range: 0- 60μm
- Minimum Setting of Sectioning Thickness: 1μm
- Total Horizontal Specimen Feed:29mm;
- Vertical Specimen Stroke:60mm
- Movement Range of the Base of BladeHolder Base: 0-60mm (front to back)
- Movement Range of the Blade Press plate: 0-23mm
- Specimen Holder Rotation: at any angle within360 degrees
- Maximum Specimen Size: 60×70mm
- Specimen Orientation:XY – 8°
- Precision Error: ±1%
- Dimensions: 570×440×290mm (W×D×H)
- Net weight: 28kg
Review(1)
Quick Comparison
KEDEE KD-2260 Manual Rotary Microtome remove | Erma B-111 Bilirubin Meter remove | Discover 14 Panel Cup with Adulterants Per Pack remove | Eppendorf Minispin Centrifuge remove | Eppendorf Pipette Tip 200ul Per Pack remove | Discover 5 Panel Cup with Adulterants Per Pack remove | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Name | KEDEE KD-2260 Manual Rotary Microtome remove | Erma B-111 Bilirubin Meter remove | Discover 14 Panel Cup with Adulterants Per Pack remove | Eppendorf Minispin Centrifuge remove | Eppendorf Pipette Tip 200ul Per Pack remove | Discover 5 Panel Cup with Adulterants Per Pack remove | ||||||||||
Image | ||||||||||||||||
SKU | SF10335601250 | SF1033560084-6 | SF1033560084-28 | SF1033560084-116 | SF1033560084-137 | SF1033560084-23 | ||||||||||
Rating | ||||||||||||||||
Price | Ask for Price | Ask for Price | Ask for Price | Ask for Price | Ask for Price | Ask for Price | ||||||||||
Stock | ||||||||||||||||
Availability | ||||||||||||||||
Add to cart | ||||||||||||||||
Description | Ship From Abroad
The Microtome KD-2260 is designed to meet multiple requirements of histology or histopathology labs. It is also suitable for the use in research labs as well as industrial quality assurance. In being manual, the Microtome KD-2260 is flexible to use at any place in the laboratory. Delivery & Availability: Typically 14-21 Working Days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | Shipped From Aboard
The advanced B111 Bilirubinmeter provides fast, accurate results for Total bilirubin level in neonates with only 40μl serum or plasma sample. It determines total bilirubin by dual wavelength photometric analysis. Suited for pediatric setups, small workload labs & hospitals because of its compact and portable design. Advanced, benchtop and precise instrument for measuring Total Bilirubin.
Delivery & Availability: Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | In stock
The Discover Cup is an all-in-one drug of abuse test cup. The strips are self contained and the entire cup is tamper resistant.
Delivery & Availability:
| In stock
| In stock
| In stock
The Discover Cup is an all-in-one drug of abuse test cup. The strips are self-contained and the entire cup is tamper resistant.
Delivery & Availability:
| ||||||||||
Content | The Microtome KD-2260 is designed to meet multiple requirements of histology or histopathology labs. It is also suitable for the use in research labs as well as industrial quality assurance. In being manual, the Microtome KD-2260 is flexible to use at any place in the laboratory. With its high-precision mechanics inside, the Microtome KD-2260 permits quality sections, while maintaining a high, consistent throughput. Great functionality and the appealing design are the key features of our microtome. Optimal user comfort enables a rapid, safe and smooth sectioning, even under heavy workload. The integrated sectioning waste tray is resistant to xylene, and can be detached for cleaning.
Technical Specifications:
| The advanced B111 Bilirubinmeter provides fast, accurate results for Total bilirubin level in neonates with only 40μl serum or plasma sample. It determines total bilirubin by dual wavelength photometric
analysis. Suited for pediatric setups, small workload labs & hospitals because of its compact and portable design. Advanced, benchtop and precise instrument for measuring Total Bilirubin.
Feature
|
All-in-One Design
| Powerful and user-friendly MiniSpin Centrifuge are small enough so that each workstation can be equipped with a “personal” centrifuge. The rotor, inner centrifuge lid, and lid latch are made of metal for maximum operation safety.
Features:
Click Here To Download Catalogue |
|
All-in-One Design
| ||||||||||
Weight | N/A | N/A | N/A | N/A | N/A | N/A | ||||||||||
Dimensions | N/A | N/A | N/A | N/A | N/A | N/A | ||||||||||
Additional information |
Meshack shiundu
Hello,please email me the operation manual for this brand.Thanks