LEEP-350 Machine

$0.00

Shipped From Abroad

Features:

▪ With memory function, the last power set appears when booted

▪It has a neutral electrode contact quality detection circuit, which can detect the contact area of the plate

Delivery & Availability:
Typically 14 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.

▪ The host has automatic monitoring and error detection

▪ Type of device: CF

▪ Accurate and efficient soft tissue cutting and coagulation control.

▪ No postoperative edema, no fibrotic scar, minimal thermal damage.

LEEP operation advantages:

SF1033560095

Description

Features:

▪ With memory function, the last power set appears when booted

▪It has a neutral electrode contact quality detection circuit, which can detect the contact area of the plate

▪ The host has automatic monitoring and error detection

▪ Type of device: CF

▪ Accurate and efficient soft tissue cutting and coagulation control.

▪ No postoperative edema, no fibrotic scar, minimal thermal damage.

LEEP operation advantages:

▪ Electric ring cutting (LEEP) for gynecological uterine lesions improves surgical accuracy, controllability and safety.

Technical Parameters;

The output Power:  200w

Four Output Modes: Cutting (200w) Blend Cut (150w) Soft Coag (100w) Strong Coag (80w)

Atmospheric Pressure Range: 86-106kpa

Power Supply: 220V-22V, 50Hz+1

Working Frequency: 360-460kHz;

The rated Power of the Equipment: 88VA+10%

Type of Device: CF

The Machine Power Consumption: <1000VA

The Technical Parameter of the Smoking Device:

Maximum Power: 200w

Noise Level: Maximum 40dB

Maximum Flow: 0-200L/Min (Adjustable Suction Force)

Power: Supply Voltage: 110V-220V, 50/60Hz

Absorption Efficiency: >95%

Absorption of Flow Rate: 200L/Min

Click Here To Download Catalogue

Reviews

There are no reviews yet.

Be the first to review “LEEP-350 Machine”

Your email address will not be published. Required fields are marked *

Quick Comparison

LEEP-350 Machine removeLittmann Classic III Stethoscope removeElectric Suction Machine removeRender SD-H3000B+ Mobile ICU Ventilator removeSonoscape S11 Ultrasound Machine removeRender SD-H3000A Mobile ICU Ventilator remove
NameLEEP-350 Machine removeLittmann Classic III Stethoscope removeElectric Suction Machine removeRender SD-H3000B+ Mobile ICU Ventilator removeSonoscape S11 Ultrasound Machine removeRender SD-H3000A Mobile ICU Ventilator remove
ImageLittmann Classic III Stethoscope
SKUSF1033560095SF1033560084-34SF1033560084-16SF1033560011-23SF1033560012-1SF1033560011-21
Rating
Price

$0.00

$34.00

$152.00

$3,850.00

$6,380.00

$5,720.00

Stock
Availability
Add to cart

DescriptionShipped From Abroad
Features: ▪ With memory function, the last power set appears when booted ▪It has a neutral electrode contact quality detection circuit, which can detect the contact area of the plate Delivery & Availability: Typically 14 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. ▪ The host has automatic monitoring and error detection ▪ Type of device: CF ▪ Accurate and efficient soft tissue cutting and coagulation control. ▪ No postoperative edema, no fibrotic scar, minimal thermal damage. LEEP operation advantages:
In Stock The Classic III stethoscope brings new design, materials, and technology to the Littmann stethoscope series that’s been used and trusted by millions of medical professionals worldwide for decades. With a two-sided chestpiece, dual tunable diaphragms, improved tubing, and much more, the Classic III stethoscope combines the best of new and traditional.

Delivery & Availability:

Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In Stock Power consumption: 120W Maximum negative pressure: ≥0.09 MPa Pump rate: ≥20 L/min Noise: ≤60 dB Continuous Working Time: 0-30 min Bottle volume: 2500 ml, 2 pcs

Delivery & Availability:

Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped from Abroad
  • Microcomputer controlled,pneumatically driven and electronically controlled.
  • Pressure, volume controlled treatment ventilator.
  • Could be applied for pediatric and adult.
  • 100% oxygen fast operation system, make sure to provide pure oxygen at any time.
  • Easy setting by navigator wheel knob & touch key
  • 5.5" lcd display,very clearly at parameter setting area,monitoring area or alarm area.
  • Automatic temperature control humidifier system for operation and maintenance easier
  • Back-up battery
  • Built-in smart type air compressor
Delivery & Availability: Typically 21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In Stock A Value Choice beyond Your Expectation. SonoScape’s trolley color Doppler system S11 redefines price and performance with practical design. The S11 will go beyond your expectations but not your budget. Delivery & Availability: Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.Shipped from Abroad
 
Delivery & Availability: Typically 21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
ContentFeatures: ▪ With memory function, the last power set appears when booted ▪It has a neutral electrode contact quality detection circuit, which can detect the contact area of the plate ▪ The host has automatic monitoring and error detection ▪ Type of device: CF ▪ Accurate and efficient soft tissue cutting and coagulation control. ▪ No postoperative edema, no fibrotic scar, minimal thermal damage. LEEP operation advantages: ▪ Electric ring cutting (LEEP) for gynecological uterine lesions improves surgical accuracy, controllability and safety. Technical Parameters; The output Power:  200w Four Output Modes: Cutting (200w) Blend Cut (150w) Soft Coag (100w) Strong Coag (80w) Atmospheric Pressure Range: 86-106kpa Power Supply: 220V-22V, 50Hz+1 Working Frequency: 360-460kHz; The rated Power of the Equipment: 88VA+10% Type of Device: CF The Machine Power Consumption: <1000VA The Technical Parameter of the Smoking Device: Maximum Power: 200w Noise Level: Maximum 40dB Maximum Flow: 0-200L/Min (Adjustable Suction Force) Power: Supply Voltage: 110V-220V, 50/60Hz Absorption Efficiency: >95% Absorption of Flow Rate: 200L/Min Click Here To Download CatalogueThe Classic III stethoscope brings new design, materials, and technology to the Littmann stethoscope series that’s been used and trusted by millions of medical professionals worldwide for decades. With a two-sided chestpiece, dual tunable diaphragms, improved tubing, and much more, the Classic III stethoscope combines the best of new and traditional. Full adult and pediatric auscultation is available through its dual head chestpiece simply by rotating the central spline to alternate between the two sides. The more compact one piece diaphragm and rim assemblies have further increased acoustic sensitivity. The binaurals have been redesigned with larger diameter ear tubes and a thicker single lumen binaural to transfer sound more effectively. The selector spline is now recessed to allow a flush fit with the binaural tube and now features a visual indicator for easy identification of the operational diaphragm. Features
  • NEW: double-sided, dual diaphragm chestpiece for both adult and paediatric assessment.
  • NEW: The paediatric side is also easily transformed into a traditional open bell by replacing the single-piece diaphragm with the supplied non-chill rim.
  • NEW: chestpiece is precision-machined into an aesthetically pleasing, less angular shape.
  • NEW: single-piece diaphragm instead of separate diaphragm/rim making it easier to attach and easier to clean due to the smooth unbroken surface.
  • NEW: The stem features an open side indicator to easily identify which diaphragm is in operation.
  • NEW: next-generation tubing gives even longer tube life with improved resistance to skin oils, alcohol and staining.
  • 3M’s ‘Tunable Technology’ lets you easily switch from low to high frequency sounds by switching from light to firm pressure on both the adult and paediatric sides of the chestpiece.
  • High acoustic sensitivity when performing general physical assessment.
  • Laser engraving of text and symbols to personalise your scope and avoid theft/loss
  • Larger ear tubes on the anatomically designed headset comfortably positioned for better sound transfer. Easy adjustment by simply squeezing or pulling apart the eartubes.
  • Comfortable Snap-Tight soft seal eartips create an excellent acoustic seal to reduce ambient noise.
  • No natural rubber latex or phthalate plasticisers are used in the tubing or any other component—to help protect health and the environment.
  • Complement your personal style with Littmann’s large range of chestpiece finishes and tubing colours.
  • Used as a diagnostic aid as part of the physical assessment of a patient.
Specification : Voltage: AC 220V, 50Hz or 110V, 60Hz Power consumption: 120 W Maximum negative pressure: ≥0.09 MPa Negative pressure range: 0.02 MPa to Max negative pressure Pump rate: ≥20 L/min Noise: ≤60 dB Continuous Working Time: 0-30 min Rest Time≥30min Bottle volume: 2500 ml, 2 pcs Accessory: pedal switch (1pc), power switch(1pc), filter(2 pcs), suction pipe(1pc, 2m in length, silica gel), celiac suction pipe(1pc, 31cm in length, chrome copper) Package: 1pc/carton Box Size : 46.5*41.5*64.5cm Net Weight: 11.5KGS Gross Weight:13.8 KGS
Click Here To Download Catalogue
Features:
  • Microcomputer controlled,pneumatically driven and electronically controlled.
  • Pressure, volume controlled treatment ventilator.
  • Could be applied for pediatric and adult.
  • 100% oxygen fast operation system, make sure to provide pure oxygen at any time.
  • Easy setting by navigator wheel knob & touch key
  • 5.5" lcd display,very clearly at parameter setting area,monitoring area or alarm area.
  • Automatic temperature control humidifier system for operation and maintenance easier
  • Back-up battery
  • Built-in smart type air compressor
  Technical Specifications:
Model NO. - SD-H3000B+
Type - ICU Ventilator Machine
Used for - Adult
O2 Concentration - 21%-100%
Use for - ICU Operating Room
Tidal Volume - 0-2000ml
Min Tidal Volume - 50-1500ml
I:E - 5.0:1~1:5.0
Peep - 0-40cm H2O
Certification - CE, FDA, ISO13485
Trademark - RENDER
Origin - China
HS Code - 9018907000
Click Here To Download Catalogue
   
DETAILS SonoScape’s trolley colour Doppler system S11 redefines price and performance with practical design. The S11 will go beyond your expectations but not your budget. As an easy-to-use ultrasound system, the S11 is integrated with a new software platform, especially optimized for a smooth workflow and convenient operation. The system speeds up the exam process and makes file management easier. SPECIFICATION - 15-inch high definition LCD monitor with articulating arm - Compact and agile trolley design - 3 active transducer sockets available for a wide range of applications - Duplex, Color Doppler, DPI, PW Doppler, tissue harmonic imaging, μ-scan speckle reduction imaging, compound imaging, trapezoidal imaging - Customized settings based on your own working style - Full patient database and image management solutions  
Click Here To Download Catalogue 
Features: Main performance and Technical Index:
  • Ventilation mode: VCV, PCV, PSV, SIMV(VCV)+PSV, SIMV(PCV)+PSV, MMV, CPAP, Backup apnea.
Air circuit Performance:
  • Maximum safety pressure of air circuit: no more than 6kpa.
  • Inspiratory oxygen concentration: 21-100%.

Ventilation Performance:           

  • Respiratory rate (f): 4-99 times / min,
  • Inspiratory time (Ti): 0.2-6 s,
  • Breath holding time (Tp): 0-2s,
  • Triggering pressure (Pt): inspiratory triggering pressure is - 2kpa-0kpa,
  • Tidal volume (Vt): 0-2000ml;
  • Maximum minute ventilation volume: not less than 18 L / min.
  • PSV:0~5 kPa,
  • Peep Pressure: 0-3kpa,
  • Inspiratory flow rate: 0-80 L / min.
  • SIMV frequency: 6-60 times / min,
  • Inspiratory pressure: 0-6kpa,

Alarm Performance:           

  • Pressure High Limit (Ph) alarm: 2 ~ 6kpa, audible and visual alarm.
  • Pressure Low Limit (Pl) alarm: 0~2KPa, audible and visual alarm.
  • Minute ventilation High Limit (Mvh) alarm: audible and visual alarm when ventilation exceeds the set value.
  • Minute ventilator Low limit (Mvl) alarm: audible and visual alarm when ventilation is lower than the set value.
  • Power off alarm: Power off alarm immediately, and the alarm duration shall not be less than 120s.
  • Mute: no more than 2 minutes.

Monitoring Performance:           

  • 12.1 inch color LCD
  • Tidal volume (VT): 0 ~ 2000ml
  • Measured total frequency (Ftot), Spont. frequency (Fspont)
  • Minute ventilation (Mv).
  • I: E ratio.
  • Airway pressure (PAW).
  • Peak pressure (Ppeak)
  • Peep pressure: 0.1 ~ 2KPa
  • Pressure-Time and Flow-Time waveform
  Technical Specifications
Model NO. - SD-H3000A
Type - Ventilator
O2 Concentration - 21%-100%
Use for - ICU Operating Room
Tidal Volume - 0-2000ml
Min Tidal Volume - 50-1500ml
I:E - 5.0:1~1:5.0
Peep - 0-40cm H2O
Kind - Gynaecology
Certification - CE, FDA, ISO13485
Group - Adult
LCD Display - With LCD Display
Trademark - RENDER
Transport Package - Wooden Package
Origin - China
HS Code - 9018907000
WeightN/AN/AN/AN/AN/AN/A
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • Rating
  • Price
  • Description
Click outside to hide the comparison bar
Compare