New

Low Energy ULT Freezer-LED Display

Ask for Price$0.00

Shipped From Abroad

Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
SF1033560130125-6

Description

QQ截图20211206155045.png

 

Product Features

 

Field Proven Reliablity

● Unique insulated inner door design for four separate storage compartments to minimize frost buildup inside the chamber

● Specialized control system design for a well-balanced operation of cascade refrigeration system

● Positive field proven reliability record

 

Safety

● Malfunction alarms including high and low temperature, power failure, sensor error, clean -filter, and extremely high ambient

● Capable of producing two types of alarm outputs: audible buzzer and visible flashing light

● Multiple built-in system protection features including user-settable protection code for controls, user settable delay to start, voltage compensation system, and protection against extreme high voltages

● Door open feature standard and USB port for temperature data downloading standard on upright models

● Remote alarm contacts

 

Installation & Application

● Wide range operating voltage system from 185V to 260 V designed to allow units installed in areas with poor voltage condition

● Suitable for 10°C to 32°C ambient temperature

● Input voltage and ambient temperature shown simultaneously for ease of monitoring environmental conditions

● Robust door latch designed for secure door closing

● Compact casters for ease of maneuvering

Low Sound Level

● Specialized refrigeration system design using whisper quiet fan and compressors

● Freezer chassis designed to absorb vibration and sound

Energy Saving

● Unique door seal design for the minimum loss of cold temperature during a door opening

● High performance VIP insulation panels to minimize cabinet heat gain and to improve temperature stability

● Patented cabinet insulation system designed for optimal performance of cold storage temperature and minimal frost buildup

● Unique design of independent insulated inner door systems for independent access of storage space to provide the maximum protection of stored samples

Key Design Features

● Microprocessor-controlled system designed for controllable range of -40°C to -86°C for cabinet space with 1°C increment

● Large LED display for cabinet temperature, set temperature, ambient temperature, and input voltage

● Settable high temperature and low temperature alarms

● Automatic clean-filter alarm and sensor error alert

● Adjustable storage shelf height

● Optional temperature recorder, storage racks and storage boxes

 

Specifications
Model Cabinet Type Capacity (L/Cu.Ft) Power Supply (V/Hz) Display Inner Doors Certificate
DW-86L338J Upright 338/11.9 220~240/50 LED 2 CE
DW-86L338JA Upright 338/11.9 120/60,208~230/60 LED 2 UL
DW-86L388J Upright 388/13.7 220~240/50 LED 2 CE
DW-86L486E Upright 486/17.1 220~240/50 LED 4 CE
DW-86L490J Upright 490/17.3 220~240/50 LED 4 CE
DW-86L490JA Upright 490/17.3 208~230/60 LED 4 UL
DW-86L578J Upright 578/20.4 120/60,220~240/50 LED 4 CE,UL,Energy Star
DW-86L578JA Upright 578/20.4 208~230/60 LED 4 UL
DW-86L628E Upright 626/22.1 220~240/50 LED 4 CE
DW-86L728J Upright 728/25.7 220~240/50 LED 4 CE,Energy Star
DW-86L728JA Upright 728/25.7 120/60,208~230/60 LED 4 UL
DW-86L828J Upright 828/29.2 220~240/50 LED 4 CE,Energy Star
DW-86L828JA Upright 828/29.2 208~230/60 LED 4 UL
DW-86W100J Chest 100/3.5 220~240/50,220~240/60 LED 1 CE
DW-86W420J Chest 420/14.8 220~240/50 LED 3 CE
DW-86W420JA Chest 420/14.8 208~230/60 LED 3 UL
Click here to download Catalogue

Reviews

There are no reviews yet.

Be the first to review “Low Energy ULT Freezer-LED Display”

Your email address will not be published. Required fields are marked *

Quick Comparison

Low Energy ULT Freezer-LED Display removeEppendorf Pipette Tip 20ul Per Pack removeiSED Fully Automated ESR Analyzer removeSkyla HB1 POC Clinical Chemistry Auto Analyzer removeAvalun LabPad Device removeSkyla Hi POC Clinical Chemistry Analyzer remove
NameLow Energy ULT Freezer-LED Display removeEppendorf Pipette Tip 20ul Per Pack removeiSED Fully Automated ESR Analyzer removeSkyla HB1 POC Clinical Chemistry Auto Analyzer removeAvalun LabPad Device removeSkyla Hi POC Clinical Chemistry Analyzer remove
ImageEppendorf Pipette Tip 20ul Per PackAvalun Labpad machine
SKUSF1033560130125-6SF1033560084-136SF1033560084-129SF1033560060-1SF1033560084-65SF1033560060-2
Rating
Price

Ask for Price$0.00

Ask for Price$0.00

Ask for Price$0.00

Ask for Price$0.00

Ask for Price$0.00

Ask for Price$0.00

Stock
Availability
Add to cart

DescriptionShipped From Abroad
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock
  • Made of high quality PP material with good transparency.
  • Applied for Gilson/Finland/Eppendorf Pipettors.
  • Carefully inspect of raw material and manufactured under strict process check, all tips are with excellent accuracy and precison.
  • Special siliconizing on the inner surface ensure no liquid adhesion and accurate sample transfer.
  • Standard tips and filter tips can be autoclaved, high temperature sterilization acceptable.
Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock
The technical innovation of the iSED® fully-automated ESR analyzer consists of directly measuring the intensity of the red cell aggregation which is responsible for Erythrocyte Sedimentation Rate (ESR). Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped from Abroad The skyla HB1 Clinical Chemistry Analyzer provides clinical testing laboratories of medical facilities and clinics with an in-vitro clinical chemistry diagnostic tool that is compact, portable, and reports rapid results. The portable design of the clinical chemistry analyzer utilizes precision photometric measurement technology, combined with the single-use disposable reagent discs. The reagent disc contains a set of dry assay reagents that are used in the quantitative testing of various biomarkers in the blood sample. Delivery & Availability: Typically 14 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.In stock The coagulometer, LabPad® INR, measures blood coagulation time thanks to a patented optical technology. This portable In-Vitro Diagnostics (IVD) device works with the Tsmart® INR single-use microcuvettes. Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.Shipped from Abroad The skyla Hi POC Clinical Chemistry Analyzer provides clinical testing laboratories of medical facilities and clinics with an in-vitro clinical chemistry diagnostic tool that is compact, portable, and reports rapid results.The use of skyla Hi in the management of diabetes enables better access to testing and rapid clinical decision making, discussion,and implementation of optimized treatment. Delivery & Availability: Typically 14 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
ContentQQ截图20211206155045.png  
Product Features
 
Field Proven Reliablity
● Unique insulated inner door design for four separate storage compartments to minimize frost buildup inside the chamber ● Specialized control system design for a well-balanced operation of cascade refrigeration system ● Positive field proven reliability record  

Safety

● Malfunction alarms including high and low temperature, power failure, sensor error, clean -filter, and extremely high ambient ● Capable of producing two types of alarm outputs: audible buzzer and visible flashing light ● Multiple built-in system protection features including user-settable protection code for controls, user settable delay to start, voltage compensation system, and protection against extreme high voltages ● Door open feature standard and USB port for temperature data downloading standard on upright models ● Remote alarm contacts  
Installation & Application
● Wide range operating voltage system from 185V to 260 V designed to allow units installed in areas with poor voltage condition ● Suitable for 10°C to 32°C ambient temperature ● Input voltage and ambient temperature shown simultaneously for ease of monitoring environmental conditions ● Robust door latch designed for secure door closing ● Compact casters for ease of maneuvering
Low Sound Level
● Specialized refrigeration system design using whisper quiet fan and compressors ● Freezer chassis designed to absorb vibration and sound

Energy Saving

● Unique door seal design for the minimum loss of cold temperature during a door opening ● High performance VIP insulation panels to minimize cabinet heat gain and to improve temperature stability ● Patented cabinet insulation system designed for optimal performance of cold storage temperature and minimal frost buildup ● Unique design of independent insulated inner door systems for independent access of storage space to provide the maximum protection of stored samples

Key Design Features

● Microprocessor-controlled system designed for controllable range of -40°C to -86°C for cabinet space with 1°C increment ● Large LED display for cabinet temperature, set temperature, ambient temperature, and input voltage ● Settable high temperature and low temperature alarms ● Automatic clean-filter alarm and sensor error alert ● Adjustable storage shelf height ● Optional temperature recorder, storage racks and storage boxes
 
Specifications
Model Cabinet Type Capacity (L/Cu.Ft) Power Supply (V/Hz) Display Inner Doors Certificate
DW-86L338J Upright 338/11.9 220~240/50 LED 2 CE
DW-86L338JA Upright 338/11.9 120/60,208~230/60 LED 2 UL
DW-86L388J Upright 388/13.7 220~240/50 LED 2 CE
DW-86L486E Upright 486/17.1 220~240/50 LED 4 CE
DW-86L490J Upright 490/17.3 220~240/50 LED 4 CE
DW-86L490JA Upright 490/17.3 208~230/60 LED 4 UL
DW-86L578J Upright 578/20.4 120/60,220~240/50 LED 4 CE,UL,Energy Star
DW-86L578JA Upright 578/20.4 208~230/60 LED 4 UL
DW-86L628E Upright 626/22.1 220~240/50 LED 4 CE
DW-86L728J Upright 728/25.7 220~240/50 LED 4 CE,Energy Star
DW-86L728JA Upright 728/25.7 120/60,208~230/60 LED 4 UL
DW-86L828J Upright 828/29.2 220~240/50 LED 4 CE,Energy Star
DW-86L828JA Upright 828/29.2 208~230/60 LED 4 UL
DW-86W100J Chest 100/3.5 220~240/50,220~240/60 LED 1 CE
DW-86W420J Chest 420/14.8 220~240/50 LED 3 CE
DW-86W420JA Chest 420/14.8 208~230/60 LED 3 UL
Click here to download Catalogue
  • Made of high quality PP material with good transparency.
  • Applied for Gilson/Finland/Eppendorf Pipettors.
  • Carefully inspect of raw material and manufactured under strict process check, all tips are with excellent accuracy and precison.
  • Special siliconizing on the inner surface ensure no liquid adhesion and accurate sample transfer.
  • Standard tips and filter tips can be autoclaved, high temperature sterilization acceptable.
  Classification: PIPETTE Brand Name: Vchanslab,Yingmed,OEM Model Number: YM-K7028 Place of Origin: China Product name: Pipette Tips Material: Polypropylene Certificate: CE/ISO13485/FDA Color: Natural, Blue, Yellow Application: Laboratory, Teaching, Hospital
The technical innovation of the iSED® fully-automated ESR analyzer consists of directly measuring the intensity of the red cell aggregation which is responsible for Erythrocyte Sedimentation Rate (ESR). Unlike traditional ESR methodologies that measure the aggregation of the red blood cells indirectly, the iSED measures it directly and expresses the values in mm/hr. Features:
  • Results in 20 Seconds

  • 100µL sample drawn directly from primary EDTA tube

  • Fully automated, walk-away operation

  • Random access

  • Positive patient identification via internal barcode reader

  • Compatible with pediatric tube

     
Technical Specifications: 
Principle of Measure: Photometrical
Results: “Printed mm/hr, Range from 1-130 mm/hr”
Sample Requirements: 500uL whole blood, collected in EDTA anti-coagulant tested 24 hours from venipuncture at room temperature or refrigerated.
Tube Requirements: 13 x 75 mm, pierceable capped tube
Quality Control: Barcoded Seditrol® QC
Barcode Reader: Internal
Printer: Internal
Interface Specifications: serial RS232 port for LIS connection
Weight: 14 kg
Dimensions (H x W x D): 36 x 27 x 34 (cm) /14.3 x 10.5 x13.4 (in)
Voltage: 100-240VAC
Frequency Range: 50-60 Hz
Power: 160W
Click Here To Download Catalogue
Skyla HB1 Clinical Chemistry Analyzer utilizes precision photometric measurement technology, combined with the single-use disposable reagent discs. The reagent disc contains a set of dry assay reagents that are used in the quantitative testing of various biomarkers in the blood sample. HB1 provides clinical testing laboratories of medical facilities and clinics with an in-vitro clinical chemistry diagnostic tool that is compact, portable, and reports rapid results. Only needs 200µl of blood (whole blood, serum or plasma is accepted.) and no sample preparation is required. All steps are designed automatically from checking the validity of reagent discs and cartridges to printing the results. Over 30 test parameters are allowed with fast analysis and results in 15 minutes. Internal Quality Control (IQC) with self-calibration of optical system, chemicals stability and interference alerts functions monitor and ensure the results with high accuracy. Available Test Panels
  • Renal Function - BUN, CREA eGFR
  • Liver Function - ALB, TP, ALP, ALT, AST, TBIL, DBIL, GGT, LDH A/G#, GLOB#, IBIL
  • Lipid Metabolism - TG, TC, HDL LDL#, VLDL
  • Pancreatitis Markers - AMY, LIPA
  • Carbohydrate Metabolism and Others - GLU , CPK, UA, LAC
  • Inflammatory Markers - CRP
  • Electrolyte - Na, K, Cl, Ca, PHOS, Mg, tCO2
SPECIFICATION Principle
  • Colormetric System : LEDs 340nm~940nm wavelength
Sample & Panel
  • Test Profiles : Panels
  • Measurement Time - Panel: up to 15 tests/ 15 min
  • Sample Type & Volume : 200 μl whole blood (PCV<60%), plasma, serum 
Device
  • User Interface : 5 inch color LCD touch screen
  • Internal Memory : Store up to 50,000 analysis results
  • Printer : Built in thermal printer or external USB printer (PCL 3GUI)
  • USB Socket : USB type A (Host) for external USB Printer, USB flash drive (FAT) or external barcode scanner
  • Data transmission to PC : RS232 serial port or RJ45 (LAN)
  • Dimensions : 233 (W) X 285 (D) X 300 (H) mm
  • Weight : 5.5 kg
Operating Condition
  • Temperature / Humidity : 10 to 32˚C / 5 to 90 %
 
Click Here To Download Catalogue
The coagulometer, LabPad® INR, measures blood coagulation time thanks to a patented optical technology. This portable In-Vitro Diagnostics (IVD) device works with the Tsmart® INR single-use microcuvettes.
  • User-friendly: the LabPad® INR is designed to be easy to use especially thanks to its 3D-shaped microcuvette that only requires a small drop of blood from a fingertip. Thanks to the color screen, both measurement steps and browsing the list of results are easy to visualize.
  • Quick and reliable: the reliability of INR results is obtained by quality controls that are performed automatically before each measurement. In less than one minute, you can see if you are in your therapeutic range.
  • Connected: the result obtained after performing the test can be transferred to healthcare professionals in charge of your treatment monitoring. This result is complementary to the pie charts and trend reports directly displayed on the LabPad® INR to help you monitoring your treatment
 
Click Here To Download Catalogue
   
skyla Hi Analyzer enables better access to testing and rapid clinical decision making, discussion, and implementation of optimized treatment. To get the result, only prepare <1 μl fingertips blood or venous blood (depends on test item) without pretreatment with easy steps and then read the result after 6 mins. The device allows two specimens be tested in one run and provides fully automatic procedures from checking the validity of cartridge to printing the results. Reagent Kit
  • HbA1C
  • CRP
  • Lipid Panel (TC,TG, HDL, LDL#)
  • Lipid Plus Panel (Glu,TC,TG, HDL, LDL#)
Main Specification
Principle
Turbidimetric Method / Biochemistry
Device
Testing Time
5~20 minutes (depends on test items)
Display and Interface
5″ TFT color touch screen LCD
Memory Capacity
50,000 test results
Dimension of Analyzer
270 x 188 x 148 mm
Weight of Analyzer
1.7 kg
Dimension of Printer Module
134 x 100 x 82.7 mm
Weight of Printer Module
0.37 kg
Power Supply
100~240 volts AC, 50-60Hz
Data Transmission
USB 2.0*4 / USB 3.0*1 / RS232*1 / RJ45*1 / Wi-Fi (optional)
Reagent and Samples
Samples
Fingertips blood or venous blood
Samples Volume
0.8 ~ 30 μL (depends on test item)
Storage Temperature (Reagent)
2 ~ 8˚C
Humidity
Relative humidity < 95% (Non-condensing)
Temperature
10 ~ 32 ˚C
Click Here To Download Catalogue
WeightN/AN/AN/AN/AN/AN/A
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • Rating
  • Price
  • Description
Click outside to hide the comparison bar
Compare