Features of Mainstream Anesthesia Multi-gas Sensor AG200
  • GAS ID identifies manually (CO2, N2O, ISO, DES, ENF, HAL, SEV).
  • Fully compatible with PHASEIN protocol.
  • Fast warm-up time display waveform within 15s.
  • Barometer pressure and temperature compensation.
  • Real-time and continuous measurement of gas concentrations and respiratory rate.
  • Low power consumption

 

Specifications of Mainstream Anesthesia Multi-gas Sensor AG200
Principle NDIR
Gas Identity By Manual
Initialization Time 15 sec, full specifications within 60 sec.
Calibration No routine user calibration required
Compensation Automatic for atmospheric pressure, temperature
Rise Time Co2 < 200ms, N2O,AA < 350ms
Respiration 3 – 150 BPM; Accuracy: ±1 BPM
Breath Detect Adaptive threshold, minimum 1% Co2 change
Agent Threshold Agent 0.3 vol%
Measuring Accuracy gas type range accuracy
CO2 0 – 10% ± (0.2 vol% +2% of reading)
10 -15% ± (0.3 vol% +2% of reading)
N2O 0 – 100% ± (2 vol% +2% of reading)
ISO, ENF, HAL 0 – 6% ± (0.2vol% +2% of reading)
DES 0 – 18% ± (0.2vol% +2% of reading)
SEV 0 – 8% ± (0.2vol% +2% of reading)
Voltage & Power 5.0VDC ±5%, Consumption Less than 1.5W
Interface RS232, operating at 9600bps
Temp & Humidity Operating: 0º to 40°, 10 to 90% RH, non-condensing
Storage: -40º to 70ºC, <90% RH, non-condensing

Reviews

There are no reviews yet.

Be the first to review “Mainstream Anesthesia Multi-gas Sensor AG200”

Your email address will not be published. Required fields are marked *

Quick Comparison

SettingsMainstream Anesthesia Multi-gas Sensor AG200 removeCWS 5000- Patient Warming Machine removeAgary I.V. Cannula removeRender SD-M2000A(P) Transport/Portable Anesthetic Machine removeTimesco Jumper Fingertip Pulse Oximeter removeTimesco Eclipse McCoy Laryngoscope Set remove
NameMainstream Anesthesia Multi-gas Sensor AG200 removeCWS 5000- Patient Warming Machine removeAgary I.V. Cannula removeRender SD-M2000A(P) Transport/Portable Anesthetic Machine removeTimesco Jumper Fingertip Pulse Oximeter removeTimesco Eclipse McCoy Laryngoscope Set remove
ImageFingertip Pulse OximeterTimesco Eclipse McCoy Laryngoscope Set
SKUSF103356013087-1SF1033560084-221SF1033560011-12SF1033560084-2SF1033560084-54
Rating
Price

$0.00

$1,045.00

$7.10

$1,320.00

$17.00

$0.00

Stock
Availability
Add to cart

DescriptionShipped From Abroad

AG200 series anesthesia gas sensor is the ideal low sampling-rate anesthesia solution for your patient monitoring system. AG200 is more cost-effective compared to the AG100 Side stream AGM Sensor.

Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock I.V Cannula with wings & injection port 24G/19mm, 0.70mm/20ml/min Injection port with unidirectional valve for facilitating extra medication and preventing back flow. Specially engineered recessed plug with protective ring to avoid risk of contamination. Angle & grooved wings for easy cannulation and to prevent rolling of cannula over patient body. Colour coded cap for easy identification of guage size.
Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped from Abroad
  • High quality & Durability Design
  • Easy operation & easy maintenance
  • Compact construction
  • Beautiful & delicate
  • Space saving for operation room.
Delivery & Availability: Typically 21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In Stock Integrated with SPO2 probe and processing display module. Small in volume、light in weight and convenient in carrying. Operation of the product is simple ,low power consumption. SPO2 , PR and Ridisplay,. Pulse rate value display, bar graph display. Low-voltage indication: low-voltage indicator appears before working abnormally which is due to low-voltage. Automatically power off function: when the device is under the state of measuring interface . it will automatically power off within 5 seconds if the finger falls out of probe. Delivery & Availability: Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.In Stock Sirius-XL Eclipse blades feature a flexible tip designed for difficult intubations and are available in Macintosh 4, 3 and 2. Supplied as a blade only in a case or as a blade and handle set in a case.

Delivery & Availability:

Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Content
Features of Mainstream Anesthesia Multi-gas Sensor AG200
  • GAS ID identifies manually (CO2, N2O, ISO, DES, ENF, HAL, SEV).
  • Fully compatible with PHASEIN protocol.
  • Fast warm-up time display waveform within 15s.
  • Barometer pressure and temperature compensation.
  • Real-time and continuous measurement of gas concentrations and respiratory rate.
  • Low power consumption
 
Specifications of Mainstream Anesthesia Multi-gas Sensor AG200
Principle NDIR
Gas Identity By Manual
Initialization Time 15 sec, full specifications within 60 sec.
Calibration No routine user calibration required
Compensation Automatic for atmospheric pressure, temperature
Rise Time Co2 < 200ms, N2O,AA < 350ms
Respiration 3 – 150 BPM; Accuracy: ±1 BPM
Breath Detect Adaptive threshold, minimum 1% Co2 change
Agent Threshold Agent 0.3 vol%
Measuring Accuracy gas type range accuracy
CO2 0 – 10% ± (0.2 vol% +2% of reading)
10 -15% ± (0.3 vol% +2% of reading)
N2O 0 – 100% ± (2 vol% +2% of reading)
ISO, ENF, HAL 0 – 6% ± (0.2vol% +2% of reading)
DES 0 – 18% ± (0.2vol% +2% of reading)
SEV 0 – 8% ± (0.2vol% +2% of reading)
Voltage & Power 5.0VDC ±5%, Consumption Less than 1.5W
Interface RS232, operating at 9600bps
Temp & Humidity Operating: 0º to 40°, 10 to 90% RH, non-condensing
Storage: -40º to 70ºC, <90% RH, non-condensing
Two speed fan motor and two levels of flow rates. CWS 5000 can inflate a very large blanket as well as a small blanket. • Uses a DC motor, quieter and state of the art blower. • CWS 5000 is controlled and operated through a unique robust software developed by Care Essentials. • The Cocoon™ CWS 5000 is light and compact, yet very sturdy. • Designed to be user friendly. • We comply with all essential regulatory standards. We have FDA, CE, TGA, Japan Health approvals. CWS 5000 has been tested for IEC 60601-1 3rd Edition, AM 1 by UL, USA.I.V Cannula with wings & injection port 24G/19mm, 0.70mm/20ml/min Injection port with unidirectional valve for facilitating extra medication and preventing back flow. Specially engineered recessed plug with protective ring to avoid risk of contamination. Angle & grooved wings for easy cannulation and to prevent rolling of cannula over patient body. Colour coded cap for easy identification of guage size.
  • High quality & Durability Design
  • Easy operation & easy maintenance
  • Compact construction
  • Beautiful & delicate
  • Space saving for operation room.
 
Click Here To download Catalogue
   
 
Integrated with SPO2 probe and processing display module • Small in volume, light in weight, convenient in carrying • Simple operation, lower power consumption • OLED screen display • SPO2, PR, bar graph of pulse, plethysmogram, blood perfusion index, battery indication display • 4 directions display, 6 display models, large fonts display • Brightness control, Demo mode, Setup menu • Movement interference • Alarm function and adjustable alarm parameters • Can be connected to mobile phones through Bluetooth; can support Android and iOS client • Auto power-off when no signal after 10s • Powered by 2*AAA alkaline batteries Specification: • Size: 62 x 37 x 32mm • Peak wavelength range of the light emitted from the probe: red light 660nm±3; infrared light 905nm±5 • Maximum optical output power of the probe: 1.2mW for infrared light (905nm) • Bluetooth module: 4.0 (single-mode) • Working temperature: 5℃ to 40℃ (41°F to 104°F) • Relative humidity: 15% to 80%, non-condensing • Atmospheric pressure: 70kPa to 106kPa • Rated voltage: DC 3V Package included: • 1 x JUMPER JPD-500F Bluetooth Fingertip Pulse Oximeter • 2 x AAA Batteries • 1 x Carry Case • 1 x Lanyard • 1 x English User ManualSirius-XL Eclipse blades feature a flexible tip designed for difficult intubations and are available in Macintosh 4, 3 and 2. Supplied as a blade only in a case or as a blade and handle set in a case.
  • The non-replaceable glass fibre bundle is fully enclosed in the blade which allows easy cleaning.
  • Rigid metal construction from fully autoclaveable, antimagnetic stainless steel.
  • Lever positioned at the rear of the blade to control the tilting tip.
  • 3 metal ball bearings for secure fitting.
  • Green ISO 7376 fitting metal block compatible with fibre optic handles.
  • Tilting tip for elevation of the epiglottis, providing an improved view of the larynx, without excessive force.
  • Atraumatic distal end.
  • Fully autoclaveable metal blade, covered by a 5 year guarantee or 4,000 autoclaves, whichever is sooner.