Mainstream ETCO2 Sensor LH910

$0.00

Shipped From Abroad

LH910 Mainstream end-tidal CO2 sensor, plug and play, less accessories required, suitable for intubated patients and veterinary monitoring. Compatible with multi-patient monitor brands: Philips, Mindray, Zoll, Comen, Nihon Kohden, Contec, Biolight, Bionet, Edan…

Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Brands:: Prior-care

Description

Features of Mainstream ETCO2 Sensor LH910

NDIR (non-dispersive infrared) technology

Small size and lightweight, long service life, low maintenance cost

Monitoring the patient’s real-time ETCO2, respiration rate, and inspired CO2

Checking and confirming ET tube placement

Alarming when accidental extubating occurs

Detecting ventilator airway connection

Fully compatible with Respironics module’s protocol

Packing List:

Mainstream ETCO2 Sensor * 1pc

Disposable ETCO2 adult airway adapter*1 pc

Disposable ETCO2 Kids airway adapter*1 pc

 

Specifications of Mainstream ETCO2 Sensor LH910
Principle NDIR
Measuring range 0-150mmHg
0  –  19.7 %
0  –  20 kPa
Accuracy 0-40mmHg @ ±2% of reading,
41-70mmHg @ ±5% of reading,
71-100mmHg @ ±8% of reading,
101-150mmHg @ ±10% of reading.
Respiration 3 – 150 BPM; Accuracy: ±1 BPM
Voltage & Power 5.0VDC ±5%, 600mA (Sensor Average Power Consumption Less than 1W)
Interface RS232, TTL (customized)
Temp & Humidity Operating: 0º to 40°, 10 to 90% RH,
Storage: -40º to 70ºC, <90% RH

 

Compatible Brands:
 

Philips Nihon Kohden Mindray Biolight
Bionet, Edan, Yonker,Infinium, DRE, Axia Surgical Contec Comen Masimo

Reviews

There are no reviews yet.

Be the first to review “Mainstream ETCO2 Sensor LH910”

Your email address will not be published. Required fields are marked *

Quick Comparison

SettingsMainstream ETCO2 Sensor LH910 removeRender SD-M2000B Anesthetic Machine removeElastomeric Pump (Disposable Infusion Pump) with PCA removeTimesco Jumper Fingertip Pulse Oximeter removeRender SD-M2000A(P) Transport/Portable Anesthetic Machine removeRender SD-M2000D Anesthetic Machine remove
NameMainstream ETCO2 Sensor LH910 removeRender SD-M2000B Anesthetic Machine removeElastomeric Pump (Disposable Infusion Pump) with PCA removeTimesco Jumper Fingertip Pulse Oximeter removeRender SD-M2000A(P) Transport/Portable Anesthetic Machine removeRender SD-M2000D Anesthetic Machine remove
ImageFingertip Pulse Oximeter
SKUSF1033560011-10SF1033560084-18SF1033560084-2SF1033560011-12SF1033560011-15
Rating
Price

$0.00

$4,840.00

$0.00

$17.00

$1,320.00

$5,940.00

Stock
Availability
Add to cart

DescriptionShipped From Abroad

LH910 Mainstream end-tidal CO2 sensor, plug and play, less accessories required, suitable for intubated patients and veterinary monitoring. Compatible with multi-patient monitor brands: Philips, Mindray, Zoll, Comen, Nihon Kohden, Contec, Biolight, Bionet, Edan...

Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped from Abroad
  • Contains Output interface for Anesthesia information management system.
  • Complete with backup battery for working more than 30 minutes.
Delivery & Availability: Typically 21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In Stock This product make the tension of silicon capsule as the driving force to control the flow by micro porous tube, it was pre-selected by doctor base on patients'situation, and then and then handed over to the patients ' self- management “to relieve or ease the pain

Delivery & Availability:

Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In Stock Integrated with SPO2 probe and processing display module. Small in volume、light in weight and convenient in carrying. Operation of the product is simple ,low power consumption. SPO2 , PR and Ridisplay,. Pulse rate value display, bar graph display. Low-voltage indication: low-voltage indicator appears before working abnormally which is due to low-voltage. Automatically power off function: when the device is under the state of measuring interface . it will automatically power off within 5 seconds if the finger falls out of probe. Delivery & Availability: Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.Shipped from Abroad
  • High quality & Durability Design
  • Easy operation & easy maintenance
  • Compact construction
  • Beautiful & delicate
  • Space saving for operation room.
Delivery & Availability: Typically 21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped from Abroad
  • Contains Output interface for Anesthesia information management system.
  • Complete with backup battery for working more than 120 minutes.
Delivery & Availability: Typically 21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Content
Features of Mainstream ETCO2 Sensor LH910
NDIR (non-dispersive infrared) technology Small size and lightweight, long service life, low maintenance cost Monitoring the patient’s real-time ETCO2, respiration rate, and inspired CO2 Checking and confirming ET tube placement Alarming when accidental extubating occurs Detecting ventilator airway connection Fully compatible with Respironics module's protocol Packing List: Mainstream ETCO2 Sensor * 1pc Disposable ETCO2 adult airway adapter*1 pc Disposable ETCO2 Kids airway adapter*1 pc  
Specifications of Mainstream ETCO2 Sensor LH910
Principle NDIR
Measuring range 0-150mmHg
0  –  19.7 %
0  –  20 kPa
Accuracy 0-40mmHg @ ±2% of reading, 41-70mmHg @ ±5% of reading, 71-100mmHg @ ±8% of reading, 101-150mmHg @ ±10% of reading.
Respiration 3 – 150 BPM; Accuracy: ±1 BPM
Voltage & Power 5.0VDC ±5%, 600mA (Sensor Average Power Consumption Less than 1W)
Interface RS232, TTL (customized)
Temp & Humidity Operating: 0º to 40°, 10 to 90% RH,
Storage: -40º to 70ºC, <90% RH
 
Compatible Brands:
 

Philips Nihon Kohden Mindray Biolight
Bionet, Edan, Yonker,Infinium, DRE, Axia Surgical Contec Comen Masimo
Features:
  • Contains Output interface for Anesthesia information management system.
  • Complete with backup battery for working more than 30 minutes.
  Technical Specifications:
Model: SD-M2000B
Brand: RENDER
Origin: Made In China
Category: Electronics & Electricity / Electronic Instrument / Electricity Meter & Instrument
Label: anesthesia machine , anesthesia ventilator , anesthesia machine
 
Click Here To Download Catalogue
 
This product make the tension of silicon capsule as the driving force to control the flow by micro porous tube, it was pre-selected by doctor base on patients'situation, and then and then handed over to the patients ' self- management “to relieve or ease the pain Product Components: one-way valve medicated device, elastic liquid storage device, liquid medicine filter, current limiting device, automatic liquid feeding device ( CBI & PCA ), pipe and the external connector; Product Features: 1. The continued to liquid (CBI) make the drug-stored sac mechanical stretch as a driving force, limited the flow through the micro porous tube to the patient safely, effectively, slightly, continuous uniform injection of liquid to analgesic effect; extrusion pump body does not affect the liquid normal velocity; liquid filtering device which can control the particles enter the body better; 2. Continued to liquid + self control to liquid ( CBI+PCA ) make the drug-stored sac mechanical stretch as a driving force, limited the flow through the micro porous tube to the patient safely, effectively, slightly, continuous uniform injection of liquid to analgesic effect; Automatic medicated function is the patients can medicate according to pain independently. Extrusion pump body does not affect the liquid normal velocity; liquid filtering device which can control the particles enter the body better; How to use: 1. Get analgesia pump out from sterile packaging, removing the cap of medicine inlet and outlet; pour the analgesic liquid in the liquid storage device, draw out the air from the liquid storage. 2. Finish medicating, waiting for the liquid outflow from the medicine outlet; please clamp tightly to stop flowing for preparation. 3. Control keys (PCA key) is a function key to add the medicine base on continue to medicated by patients' self-controlled. So the patients can self-control the PCA key under the guidance of doctors, according to the needs while they are in treatment. At the same time, doctor should fill in PCA treatment card, so that they can analyze the condition from PCA additional times.Integrated with SPO2 probe and processing display module • Small in volume, light in weight, convenient in carrying • Simple operation, lower power consumption • OLED screen display • SPO2, PR, bar graph of pulse, plethysmogram, blood perfusion index, battery indication display • 4 directions display, 6 display models, large fonts display • Brightness control, Demo mode, Setup menu • Movement interference • Alarm function and adjustable alarm parameters • Can be connected to mobile phones through Bluetooth; can support Android and iOS client • Auto power-off when no signal after 10s • Powered by 2*AAA alkaline batteries Specification: • Size: 62 x 37 x 32mm • Peak wavelength range of the light emitted from the probe: red light 660nm±3; infrared light 905nm±5 • Maximum optical output power of the probe: 1.2mW for infrared light (905nm) • Bluetooth module: 4.0 (single-mode) • Working temperature: 5℃ to 40℃ (41°F to 104°F) • Relative humidity: 15% to 80%, non-condensing • Atmospheric pressure: 70kPa to 106kPa • Rated voltage: DC 3V Package included: • 1 x JUMPER JPD-500F Bluetooth Fingertip Pulse Oximeter • 2 x AAA Batteries • 1 x Carry Case • 1 x Lanyard • 1 x English User Manual
  • High quality & Durability Design
  • Easy operation & easy maintenance
  • Compact construction
  • Beautiful & delicate
  • Space saving for operation room.
 
Click Here To download Catalogue
   
 
Features:
  • Contains Output interface for Anesthesia information management system.
  • Complete with backup battery for working more than 120 minutes.
Click Here To Download Catalogue
   
 
WeightN/AN/AN/AN/AN/AN/A
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • Rating
  • Price
  • Description
Click outside to hide the comparison bar
Compare