Mainstream Multigas Module AneSure-M
$0.00
Shipped From Abroad
Mainstream Anesthesia Multi-Gas Module, simultaneously measures the concentration waveform and data of carbon dioxide, nitrous oxide, and anesthetic gas, as well as respiratory rate. The types of anesthetic gas measured include halothane, enflurane, isoflurane, sevoflurane, and desflurane. The user can manually select the type of anesthetic gas.
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Description
Features of Mainstream Multigas Module AneSure-M
- Reliable multi gas OEM solution
Equipped With Oxygen Battery. Reliable multi-gas OEM solution, compatible with a variety of protocols, so that your products can be quickly upgraded and assembled.
- Mainstream Mode
Can simultaneously measure the concentration waveform and data of carbon dioxide, nitrous oxide and anesthetic gas, as well as respiratory rate. The types of anesthetic gas measured include halothane, enflurane, isoflurane, sevoflurane and desflurane. The user can manually select the type of anesthetic gas.
- Plug And Play
The host does not need an internal circuit, just a serial port. The data can be measured within 4 seconds after powering on. It is suitable for adults, children, and newborns, with excellent cost performance and low cost.
- Automatic Pressure Compensation
There is an atmospheric pressure sensor inside, which is suitable for various altitude ranges. High-precision. Careful selection of infrared devices, hardware design, and software algorithm, to achieve a high signal-to-noise ratio, to ensure the measurement accuracy for a temperature range of – 5-50 °C and in the range of 0 – 20%.
Specifications of Anesthesia Multi-gas Detector AneSure™-M
Working condition | 5°C to 50°C, 10 to 90% RH, noncondensing |
Circumstance pressure | 55-115kpa |
Power consumption | <180 mA |
Interface | RS-232/Standard E-8-1, 38.4 kBaud,10 ms data interval (KM) or customized communication protocol |
EtCO2, FiCO2 measurement | range:0-150 mmHg, 0-20 kPa, 0-19.7%
Accuracy:±2mmHg for CO2 range 0 – 40mmHg ±5% for CO2 range from 41 – 70mmHg ±8% for CO2 range from 71 – 100mmHg ±10% Over 100mmHg |
FiN2O, EtN2O measurement | Range: 0-100%
Accuracy: ± (2 vol% + 2% of reading |
FiHAL/EtHAL, FiENF/EtENF, FiISO/EtISO measurement | Range: 0-12%
Accuracy: 0-8%: ± (0.15 vol% + 5% of reading) 8-12%: unspecified |
FiSEV, EtSEV measurement | Range: 0-15%
Accuracy: 0-10%: ± (0.15 vol% + 5% of reading) 10-15%: unspecified |
FiDES, EtDES measurement | Range:0-25%
Accuracy: 0-18%: ± (0.15 vol% + 5% of reading) 18-25%: unspecified |
Gas compensation | O2 (HOST supplied), or automatically compensation if O2 equipped |
Barometric Pressure | Having barometric pressure sensor and automatically compensation |
Warm-up time | 10 seconds reach designed deviation 97%,
20 seconds reach designed deviation. |
Rise times (t10- 90 %) | CO2:<70ms
N2O and AGENT:<300ms |
Calibration | No need to calibrate |
Zero | Implement when replacing adaptor |
Application Scenarios of Anesthesia Multi-gas Detector AneSure™-M
- Equipped with an Oxygen battery, reliable multi-gas OEM solution, compatible with a variety of protocols, so that your products can be quickly upgraded and assembled.
- Mainstream mode can simultaneously measure the concentration waveform and data of carbon dioxide, nitrous oxide, and anesthetic gas, as well as respiratory rate. The types of anesthetic gas measured include halothane, enflurane, isoflurane, sevoflurane, and desflurane. The user can manually select the type of anesthetic gas.
- Plug and play, the host does not need an internal circuit, just a serial port. The data can be measured within 4 seconds after powering on. It is suitable for adults, children, and newborns, with excellent cost performance and low cost.
- Automatic pressure compensation. There is an atmospheric pressure sensor inside, which is suitable for various altitude ranges. High-precision. Careful selection of infrared devices, hardware design, and software algorithm, to achieve a high signal-to-noise ratio, to ensure the measurement accuracy for the temperature range of – 5-50 °C and in the range of 0 – 20%.
Quick Comparison
Settings | Mainstream Multigas Module AneSure-M remove | CWS 5000- Patient Warming Machine remove | MediPlus Bain Circuit (Adult) remove | Render SD-M2000B Anesthetic Machine remove | Timesco Eclipse McCoy Laryngoscope Set remove | CryoIQ CIQ-DP-L- Cryo DERM Plus Liquid Device with LED Light (CiQ-A-LED) remove | ||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Name | Mainstream Multigas Module AneSure-M remove | CWS 5000- Patient Warming Machine remove | MediPlus Bain Circuit (Adult) remove | Render SD-M2000B Anesthetic Machine remove | Timesco Eclipse McCoy Laryngoscope Set remove | CryoIQ CIQ-DP-L- Cryo DERM Plus Liquid Device with LED Light (CiQ-A-LED) remove | ||||||||||||||||||||||||||||||||||||||||
Image | ![]() | ![]() | ![]() | ![]() | ![]() | ![]() | ||||||||||||||||||||||||||||||||||||||||
SKU | SF1033560130170-11 | SF103356013087-1 | SF1033560084-21 | SF1033560011-10 | SF1033560084-54 | SF1033560096-4 | ||||||||||||||||||||||||||||||||||||||||
Rating | ||||||||||||||||||||||||||||||||||||||||||||||
Price |
| $1,045.00 | $28.00 | $4,840.00 |
|
| ||||||||||||||||||||||||||||||||||||||||
Stock | ||||||||||||||||||||||||||||||||||||||||||||||
Availability | ||||||||||||||||||||||||||||||||||||||||||||||
Add to cart | ||||||||||||||||||||||||||||||||||||||||||||||
Description | Shipped From Abroad
Mainstream Anesthesia Multi-Gas Module, simultaneously measures the concentration waveform and data of carbon dioxide, nitrous oxide, and anesthetic gas, as well as respiratory rate. The types of anesthetic gas measured include halothane, enflurane, isoflurane, sevoflurane, and desflurane. The user can manually select the type of anesthetic gas.
Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| In Stock
| Shipped from Abroad
| In Stock
Sirius-XL Eclipse blades feature a flexible tip designed for difficult intubations and are available in Macintosh 4, 3 and 2. Supplied as a blade only in a case or as a blade and handle set in a case.
Delivery & Availability: Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | Shipped from Abroad
CryoIQ device is perfectly fitted for treatment of warts and other common skin lesions. Its unique construction with a built-in non-return valve prevents gas leakage thus giving a maximum use of the gas content. Areas of application are general practice, dermatology, pediatrics, podiatry, aesthetics, veterinary and gynecology/urology.
| |||||||||||||||||||||||||||||||||||||||||
Content | Features of Mainstream Multigas Module AneSure-M
Equipped With Oxygen Battery. Reliable multi-gas OEM solution, compatible with a variety of protocols, so that your products can be quickly upgraded and assembled.
Can simultaneously measure the concentration waveform and data of carbon dioxide, nitrous oxide and anesthetic gas, as well as respiratory rate. The types of anesthetic gas measured include halothane, enflurane, isoflurane, sevoflurane and desflurane. The user can manually select the type of anesthetic gas.
The host does not need an internal circuit, just a serial port. The data can be measured within 4 seconds after powering on. It is suitable for adults, children, and newborns, with excellent cost performance and low cost.
There is an atmospheric pressure sensor inside, which is suitable for various altitude ranges. High-precision. Careful selection of infrared devices, hardware design, and software algorithm, to achieve a high signal-to-noise ratio, to ensure the measurement accuracy for a temperature range of - 5-50 °C and in the range of 0 - 20%.
Specifications of Anesthesia Multi-gas Detector AneSure™-M
Application Scenarios of Anesthesia Multi-gas Detector AneSure™-M
| Two speed fan motor and two levels of flow rates. CWS 5000 can inflate a very large blanket as well as a small blanket. • Uses a DC motor, quieter and state of the art blower. • CWS 5000 is controlled and operated through a unique robust software developed by Care Essentials. • The Cocoon™ CWS 5000 is light and compact, yet very sturdy. • Designed to be user friendly. • We comply with all essential regulatory standards. We have FDA, CE, TGA, Japan Health approvals. CWS 5000 has been tested for IEC 60601-1 3rd Edition, AM 1 by UL, USA. |
|
Click Here To Download Catalogue | Sirius-XL Eclipse blades feature a flexible tip designed for difficult intubations and are available in Macintosh 4, 3 and 2. Supplied as a blade only in a case or as a blade and handle set in a case.
Click Here To Download Catalogue | CryoIQ device is perfectly fitted for treatment of warts and other common skin lesions. Its unique construction with a built-in non-return valve prevents gas leakage thus giving a maximum use of the gas content. Areas of application are general practice, dermatology, pediatrics, podiatry, aesthetics, veterinary and gynecology/urology. The device uses a state-of-the-art cooling technology that does not require handling of potentially dangerous gases and liquids meaning that the gas cartridge is safely replaced when empty. The device features an ergonomic design where the cooling medium is evenly, accurately and economically distributed by depressing the metering lever.
Features:
| ||||||||||||||||||||||||||||||||||||||||
Weight | N/A | N/A | N/A | N/A | N/A | N/A | ||||||||||||||||||||||||||||||||||||||||
Dimensions | N/A | N/A | N/A | N/A | N/A | N/A | ||||||||||||||||||||||||||||||||||||||||
Additional information |
Reviews
There are no reviews yet.