Hot
/

Manual lensmeter

$0.00

Shipped from abroad

The NJC-4 Lensmeter is used to measure the diopters of spherical lens and cylinder lens, the axis of cylinder lens, the strength and the baseline direction of shuttle lens, it can also stamp the optical center of lens, the axis of cylinder len and the base direction of shuttle lens.

Delivery & Availability:
Typically 14 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.

 

SF1033560107-22
Brands:: Vision Star

Description

The NJC-4 Lensmeter is used to measure the diopters of the spherical lens and cylinder lens, the axis of cylinder lens, the strength and the baseline direction of shuttle lens, it can also stamp the optical center of the lens, the axis of cylinder lens, and the base direction of shuttle lens. This instrument (Both Ac and Dc are permitted Two cells When Dc) has clear readings and graduations as well as high objective precision and reliabilities except that it can be operated easily and conveniently, AU the lenses and the made glasses can be measured by it, therefore, it is a required and ideal measuring instrument for glasses manufactures, glasses stores and ophthalmological hospitals.

Technical Specifications:

  • Eyepiece focusing range: ±5D
  • The top point diopter measuring range: 0—±20D
  • The minimum measuring square value: 0.125D
  • The shuttle lens measuring range: 5A
  • The shuttle lens square value: 1A
  • The cylinder lens axial range: 0—180°
  • The cylinder lens axial square value: 5°
  • The maximum diameter of the measured lenses l00m/m
  • Power supply: AC 110V-6V DC 3V
  • Note: This item is AC 110V; The battery is not included!

 

Reviews

There are no reviews yet.

Be the first to review “Manual lensmeter”

Your email address will not be published. Required fields are marked *

Quick Comparison

SettingsManual lensmeter removeDrGem Floor Mounted Analogue X-ray removeDrGem Ceiling Analogue X-ray Machine removeSonoscape P20 Ultrasound Machine removeDrGem Ceiling Mounted Digital X-ray removeBistos BT-770-12.1" Touchscreen Patient Monitor remove
NameManual lensmeter removeDrGem Floor Mounted Analogue X-ray removeDrGem Ceiling Analogue X-ray Machine removeSonoscape P20 Ultrasound Machine removeDrGem Ceiling Mounted Digital X-ray removeBistos BT-770-12.1" Touchscreen Patient Monitor remove
ImageMecan Manual lensmeter NJC-4DrGem GXR-S 400mA Floor Mounted Analogue X-ray MachineDrGem GXR-S 400mA Ceiling Mounted Analogue X-ray MachineDrGem GXR-SD 400mA Ceiling Mounted Digital X-ray MachineBistos BT-770-12.1" Touchscreen Patient Monitor
SKUSF1033560107-22SF1033560074-6SF1033560074-7SF1033560012-9SF1033560074-4SF1033560059-1
Rating
Price

$0.00

$0.00

$0.00

$0.00

$0.00

$902.00

Stock
Availability
Add to cart

DescriptionShipped from abroad The NJC-4 Lensmeter is used to measure the diopters of spherical lens and cylinder lens, the axis of cylinder lens, the strength and the baseline direction of shuttle lens, it can also stamp the optical center of lens, the axis of cylinder len and the base direction of shuttle lens.
Delivery & Availability: Typically 14 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.  
In Stock GXR Analogue X-ray system matches with a radiographic room which perfectly fits your workow and can be easily upgraded to DR system with the help of DR interface and PC interface in GXR generator as well as Bucky suitable to Flat Panel Detector. GXR X-ray system is equipped with a high frequency X-ray generator which consistently produces high quality radiograph in favor of high quality X-ray output with a very small kV ripple and accurate mA and mAs. GXR X-ray system is designed to provide convenience to operator and comfort to patient. Delivery & Availability: Typically 21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.Shipped from abroad The DrGem Ceiling Analogue X-ray Machine is a diagnostic radiography system that provides reliable high quality radiographic images with a reduced dose. The reliable high-frequency x-ray generators that are known worldwide for their excellent performance, lifetime and stability. Patient tables and wall stands are also offered. Delivery & Availability: Typically 21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.Shipped from Abroad Incorporating innovative technologies, P20’s user-friendly design with a simple operation panel, intuitive user interface and a variety of intelligent auxiliary scanning tools, will significantly improve your daily examination experience. Besides general imaging applications, P20 has entitled with diagnostic 4D technology which has an extraordinary performance in obstetrics and gynecology applications. Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.In Stock The GXR-SD is a diagnostic digital radiography system that provides reliable high quality digital radiographic images with a reduced dose. The GXR-SD DR systems offer comprehensive digital solutions to all radiography needs, featuring ACQUIDR digital imaging system with stationary or portable digital flat-panel detectors as well as reliable high-frequency x-ray generators that are known worldwide for their excellent performance, lifetime and stability. Patient tables and wall stands are also offered. Delivery & Availability: Typically 21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.Shipped from Abroad The Bistos BT-770 patient monitor is equipped with a 12.1" touchscreen display, which allows for an easy operation and readability with a powerful rechargeable battery guaranteeing a continuous operation of 5 hours to monitor ECG, SpO2, NIBP, temperature and respiration Delivery & Availability: Typically 14 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
ContentThe NJC-4 Lensmeter is used to measure the diopters of the spherical lens and cylinder lens, the axis of cylinder lens, the strength and the baseline direction of shuttle lens, it can also stamp the optical center of the lens, the axis of cylinder lens, and the base direction of shuttle lens. This instrument (Both Ac and Dc are permitted Two cells When Dc) has clear readings and graduations as well as high objective precision and reliabilities except that it can be operated easily and conveniently, AU the lenses and the made glasses can be measured by it, therefore, it is a required and ideal measuring instrument for glasses manufactures, glasses stores and ophthalmological hospitals. Technical Specifications:
  • Eyepiece focusing range: ±5D
  • The top point diopter measuring range: 0—±20D
  • The minimum measuring square value: 0.125D
  • The shuttle lens measuring range: 5A
  • The shuttle lens square value: 1A
  • The cylinder lens axial range: 0—180°
  • The cylinder lens axial square value: 5°
  • The maximum diameter of the measured lenses l00m/m
  • Power supply: AC 110V-6V DC 3V
  • Note: This item is AC 110V; The battery is not included!
 
DrGem GXR Floor Mounted Analogue X-ray system matches with a radiographic room which perfectly fits your workflow and can be easily upgraded to DR system with the help of DR interface and PC interface in GXR generator as well as Bucky suitable to Flat Panel Detector. GXR (Analogue X-ray)system is equipped with a high frequency X-ray generator which consistently produces high quality radiograph in favor of high quality X-ray output with a very small kV ripple and accurate mA and mAs. GXR (Analogue X-ray) system is designed to provide convenience to operator and comfort to patient. Features of DrGem GXR Floor Mounted Analogue X-ray:
  • 4 way Tabletop Patient Table (PBT-4) A large tabletop with extended travel enables all radiography studies with minimal patient movement, and supporting patient weight up to 300kg. Fully at tabletop without a frame on the edge makes cleanliness and odors free
  • Floor Mount Tube Stand (TS-FM6) Floor Rail type tube stand provides all radiography studies with smooth movement on the rail.
  • Wall Bucky Stand (WBS) Elegant design, durable and easy-to-use Wall Bucky Stand provides full satisfaction.
Technical Specifications of DrGem GXR Floor Mounted Analogue X-ray:
  • Power Rating - 32KW
  • Generator - GXR-32S
  • Rotor - Dual Speed Starter(DSS)
  • Input Power - 400/480VAC, Three phase
  • Line Frequency - 50/60Hz
  • X-ray tube - DXT-12M, (0.6/1.2mm, 300kHU)
  • Tube Voltage - 40 to 150kV, 1kV Step
  • Tube Current – 10 to 640mA
  • Output - 640mA@81kV,  500mA@104kV, 400mA@130kV, 320mA@150kV
  • Time Range - 1ms to 10s
  • mAs Range - 0.1 to 800mAs
  • Reproducibility - Coe­cient of Variation : kV < 0.005, Time < 0.005,mAs < 0.01
  • Accuracy - kV < ±(1%+1kV), mA < ±(3%+1mA), Time <±(1%+0.5ms), mAs < ±(3%+0.1mAs)
  • Linearity - Coe­cient of Linearity < 0.01 : CL = (X1-X2)/(X1+X2), where X is mR/mAs
 
Click Here To Download Catalogue
DrGem Ceiling Analogue X-ray Machine is a diagnostic radiography system X-ray Machine that provides reliable high quality radiographic images with a reduced dose. The reliable high-frequency x-ray generators that are known worldwide for their excellent performance, lifetime and stability. Patient tables and wall stands are also offered. Features of DrGem Ceiling Analogue X-ray Machine
  • TS-CSA-A (Vertical movement, 1.6m stroke, rail length 3x4meter) including HV cable 15m
  • WBS-TA:  Vertical movement
  1. V Stroke:1,450mm in Uprigh Bucky Position,
  2. 1,526mm in Horizontal Bucky position.
  • PBT-4 is a 4 way Floating Tabletop with. A large tabletop with extended travel enables all radiography studies with minimal patient movement. Fully fat tabletop without a frame on the edge makes cleanliness and odors free
Technical Specifications of DrGem Ceiling Analogue X-ray Machine
  • Power Rating - 32KW
  • Generator - GXR-32S
  • Rotor - Dual Speed Starter(DSS)
  • Input Power - 400/480VAC, Three phase
  • Line Frequency - 50/60Hz
  • X-ray tube - DXT-12M, (0.6/1.2mm, 300kHU)
  • Tube Voltage - 40 to 150kV, 1kV Step
  • Tube Current – 10 to 640mA
  • Output - 640mA@81kV,  500mA@104kV, 400mA@130kV, 320mA@150kV
  • Time Range - 1ms to 10s
  • mAs Range - 0.1 to 800mAs
  • Reproducibility - Coe­cient of Variation : kV < 0.005, Time < 0.005,mAs < 0.01
  • Accuracy - kV < ±(1%+1kV), mA < ±(3%+1mA), Time <±(1%+0.5ms), mAs < ±(3%+0.1mAs)
  • Linearity - Coe­cient of Linearity < 0.01 : CL = (X1-X2)/(X1+X2), where X is mR/mAs
  • Mechanical Parts:
-TS-CSA-A (Vertical movement, 1.6m, stroke rail length 3x4meter) including HV cable 15m - PBT-4: 4 way Floating Tabletop with Elevating Feature (66cm). - WBS-TA:   a.  Vertical    movement
  1.   V Stroke:1,450mm in Upright Bucky
  2. Position, 1,526mm in Horizontal Bucky position.
- HVC-15: 15M HV cable - Auto Collimator  
Click Here To Download Catalogue
DETAILS Upgraded Images with More Clarity SonoScape never stops making progress in improving the image quality of its ultrasound products to enhance the confidence of diagnosis for doctors. With extraordinary images provided by P20, the anatomy structures are clearer than ever. C-Xlasto Imaging With C-xlasto Imaging, P20 enables comprehensive quantitative elastic analysis. Meanwhile, C-xlasto on P20 is supported by linear, convex and transvaginal probes, to ensure good reproducibility and highly consistent quantitative elastic results. S-Live S-Live allows for detailed visualization of subtle anatomical features, thereby enabling intuitive diagnosis with real-time 3D images and enriching patient communication. Pelvic Floor 4D Transperineal 4D pelvic floor ultrasound can provide useful clinical values in assessing the vaginal delivery impact on the female anterior compartment, judging whether the pelvic organs are prolapsed or not and the extent, determining if the pelvic muscles were torn accurately. Anatomic M Mode Anatomic M Mode helps you observe the myocardial motion at different phases by freely placing sample lines. It accurately measures the myocardial thickness and the heart size of even difficult patients and supports the myocardial function and LV wall-motion assessment. Tissue Doppler Imaging P20 is endowed with Tissue Doppler Imaging which provides velocities and other clinical information on myocardial functions, facilitating clinical doctors with the ability to analyze and compare the motions of different parts of the patient's heart.  
Click Here To Download Catalogue
DrGem Ceiling Mounted Digital X-ray is a diagnostic digital radiography system that provides reliable high quality digital radiographic images with a reduced dose. The GXR-SD DR systems offer comprehensive digital solutions to all radiography needs, featuring ACQUIDR digital imaging system with stationary or portable digital flat-panel detectors as well as reliable high-frequency x-ray generators that are known worldwide for their excellent performance, lifetime and stability. Patient tables and wall stands are also offered. Features:
  • TS-CSA-A (Vertical movement, 1.6m stroke, rail length 3x4meter) including HV cable 15m
  • WBS-TA: Vertical movement
  1. V Stroke:1,450mm in Uprigh Bucky Position,
  2. 1,526mm in Horizontal Bucky position.
  • PBT-4 is a 4 way Floating Tabletop. A large tabletop with extended travel enables all radiography studies with minimal patient movement. Fully fat tabletop without a frame on the edge makes cleanliness and odors free
  • Digital Flat Panel Detector (FPD) – Wireless 17X14 (Csl, 4336W) with Auto Exposure Detection (AED) function, there is no DR trigger cable between detector and generator.
  • Full Featured Imaging Software & Excellent Digital Image Processing:
  1. Provides convenient user interface and easy operation
  2. Anatomical view-based digital image processing automatically optimizes and enhances the quality of the captured image for the pictured anatomy.
  3. Radiographic stand & automatic collimator control function
  4. DICOM 3.0 networking interface includes Worklist, Print, Store, Query for integration with any PACS or RIS
  • Included – Software, HP Laptop Computer
  1. CPU≥3.2GHz
  2. Memory capacity:≥4GB
  3. Hard drive capacity :≥500 GB
  4. Resolution: 1280 x 1024
  5. Display size: 21 inch color LCD screen
  6. 64 bit Windows 10 operation system
  7. Core: i5
  Technical Specification:
  • Power Rating - 32KW
  • Generator - GXR-32S
  • Rotor - Dual Speed Starter(DSS)
  • Input Power - 400/480VAC, Three phase
  • Line Frequency - 50/60Hz
  • X-ray tube - DXT-12M, (0.6/1.2mm, 300kHU)
  • Tube Voltage - 40 to 150kV, 1kV Step
  • Tube Current – 10 to 640mA
  • Output - 640mA@81kV,  500mA@104kV, 400mA@130kV, 320mA@150kV
  • Time Range - 1ms to 10s
  • mAs Range - 0.1 to 800mAs
  • Reproducibility - Coe­cient of Variation : kV < 0.005, Time < 0.005,mAs < 0.01
  • Accuracy - kV < ±(1%+1kV), mA < ±(3%+1mA), Time <±(1%+0.5ms), mAs < ±(3%+0.1mAs)
  • Linearity - Coe­cient of Linearity < 0.01 : CL = (X1-X2)/(X1+X2), where X is mR/mAs
  • Mechanical Parts:
-TS-CSA-A (Vertical movement, 1.6m, stroke rail length 3x4meter) including HV cable 15m - PBT-4: 4 way Floating Tabletop. - WBS-TA: a. Vertical    movement
  1. V Stroke:1,450mm in Upright Bucky
  2. Position, 1,526mm in Horizontal Bucky position.
- HVC-15: 15M HV cable - Auto Collimator  
Click Here To Download Catalogue
Bistos BT-770 is a 12.1" touchscreen patient monitor designed for easy operations. SPECIFICATIONS
  • 12.1“ color TFT touch screen
  • ECG, Resp., SpO2, NIBP, Temp., CO2, IBP, Multi-gas, C.O., Masimo SpO2
  • Precise ECG measurement with pacemaker detection ST segment and 16 types of arrhythmia analysis Double overpressure protection for NIBP Intelligent cuff inflation pressure adjustment
  • Smart Hook/Stand design, provide multiple placement modes Plug & Play Modular IBP& C.O., Modular Printer Multiple configuration options: 4-channel IBP, CO2, invasive C.O., Multi-gas Over 5 hours continuous working on battery 12-15V wide range DC input, suitable for ambulance Capable to connect with central monitoring system HL7 export to clinical information systems (option)
 
Click Here To Download Catalogue
WeightN/AN/AN/AN/AN/AN/A
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • Rating
  • Price
  • Description
Click outside to hide the comparison bar