Medical Waste Incinerator 60kg

$0.00

Shipped From Abroad

Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
SF1033560130107-1
Brands:: Shandong LVDU

Description

Characteristics
The main characteristics and scope of application of incinerator
LDF series medical waste incinerator is a medical waste incineration equipment with independent intellectual property rights developed by Shandong Lvdu Environmental Equipment Co., LTD., which introduced the world’s advanced medical incinerator technology and organized technical experts to tackle key problems. The equipment has the characteristics of full closure, small size, high incineration efficiency, reasonable process, leading technology, and high degree of harmfulness. It is an ideal garbage disposal equipment for all kinds of hospitals, hotels, stations, large commercial institutions, enterprises, and public institutions. Main features:
1. Gasification incineration technology is applied to the incineration of syringes, drip containers and other medical equipment as well as all kinds of paper waste, bandages, absorbent cotton, all kinds of medical sewage and all kinds of waste discharged by hospitals and medical institutions.
2. Using gasification incineration method, the waste generated every day can be incinerated once.
3. The use of gasification incineration, mixed incineration, burnout treatment and other technologies, so that the exhaust smoke, soot content is lower than the national emission standards.
4. Fully enclosed operation, suitable for the treatment of infectious medical waste, to avoid secondary pollution.
5. Small size, small footprint.
6. The series of incinerators are divided into fuel oil and gas, and users can use different types according to their needs.
Technical characteristics of incinerators
LDF series medical waste incinerator adopts the most advanced incineration method of primary pyrolysis gasification + wind cocombustion + secondary incineration + burnout treatment. The design of the primary combustion chamber of the incinerator adopts the gasification incineration technology to make the temperature in the incinerator shift from 200ºC to 400ºC, and the waste will not produce frit, slag, sintering and other problems in the incineration process. Compared with direct combustion furnace and other furnaces, the dust production of gasification incinerator is very small, and secondary combustion burners and circumferential air supply devices are installed in the secondary mixed incineration chamber. At high temperatures, the combustible gas in the flue gas can be fully burned, and the gas produced by the gasifier can be fully mixed with the air to burn efficiently, preventing the carbon in the gas flame from escaping and the occurrence of late burning. When the flue gas enters the high temperature burnout chamber, due to the use of tangential entry and tangential entry of combustion-supporting air, the flue gas can be fully burned again in the burnout chamber, and the use of rotating airflow for flue gas dust removal. The residence time of the incinerator flue gas in the furnace is greater than 2 seconds, so that the combustible gas in the flue gas and the combustible matter in the fly ash are completely incinerated. The upper part of the incinerator is equipped with dry tail gas purification equipment to adsorb hydrogen chloride and sulfur oxides produced in the incineration, and the odor and other components in the flue gas are decomposed at high temperature. The flue gas purification system is equipped with calcium hydroxide filter brick for neutralizing reaction with acid gas to achieve the purpose of adsorption of acid gas and purification of tail gas. The harmful components in the flue gas are reduced to the national “Hazardous Waste incineration Pollution Control Standard (GB18484-2001)” and other standards below the specified value.
The operation control of the incinerator adopts automatic program control, which reduces the labor degree of the workers, and the design of the furnace door and ash cleaning door adopts the fully sealed structure in the form of the child and the mother. During the incineration, the furnace is completely isolated from the outside of the furnace, forming negative pressure combustion, which eliminates the possibility of secondary pollution, especially the treatment of infectious dangerous medical waste, which can highlight its unique advantages.

Reviews

There are no reviews yet.

Be the first to review “Medical Waste Incinerator 60kg”

Your email address will not be published. Required fields are marked *

Quick Comparison

SettingsMedical Waste Incinerator 60kg removeSTERIPLUS 20 removeARVS Cardboard Safety Boxes 4 Ply removeSharps Containers – Nursy Series 3 LT removeSharps Containers – PBS Series 0.8 LT removeABS Body Manual Needle & Syringe Cutter remove
NameMedical Waste Incinerator 60kg removeSTERIPLUS 20 removeARVS Cardboard Safety Boxes 4 Ply removeSharps Containers – Nursy Series 3 LT removeSharps Containers – PBS Series 0.8 LT removeABS Body Manual Needle & Syringe Cutter remove
Image
SKUSF1033560130107-1SF103356013097-1SF1033560084-91
Rating
Price

$0.00

$0.00

$3.30

$0.00

$0.00

$0.00

Stock
Availability
Add to cart

DescriptionShipped From Abroad
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad

INTEGRATED INFECTIOUS WASTE PRE-SHREDDING AND STEAM STERILIZATION SYSTEM

Tesalys STERIPLUS ™ systems are the ideal solution to safely inactivate your infectious waste on site. Their integrated TESASHRED ™ shredding system not only allows a consequent reduction in the volume and weight of waste, but also guarantees their treatment at heart. Click here to download Catalogue  
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock

The ARVS 4 Ply Cardboard Safety Box provides enhanced strength and puncture resistance for the safe disposal of used syringes, needles, and infectious waste. Designed for secure, eco-friendly containment, it's ideal for hospitals, field clinics, and vaccination programs handling high-risk waste.

Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad The Nursy Series 3 Ltr Sharps Container is a medium-capacity, puncture-proof solution for disposing of used needles, syringes, and other medical sharps. Designed for nurse stations, clinics, and labs, it ensures safe handling, biohazard compliance, and efficient waste segregation.
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad The PBS Series 0.8 Ltr Sharps Container is a compact, high-quality solution for the safe disposal of used needles, syringes, and other sharps. Ideal for clinics, home care, and mobile medical units, it offers secure, puncture-proof containment with a reliable locking lid.
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad This ABS body manual needle and syringe cutter offers a reliable, safe solution for disposing of used medical sharps. Designed for hospitals, clinics, and mobile health units, it’s durable, user-friendly, and promotes hygienic waste management while minimizing the risk of needle-stick injuries.
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Content
Characteristics
The main characteristics and scope of application of incinerator LDF series medical waste incinerator is a medical waste incineration equipment with independent intellectual property rights developed by Shandong Lvdu Environmental Equipment Co., LTD., which introduced the world's advanced medical incinerator technology and organized technical experts to tackle key problems. The equipment has the characteristics of full closure, small size, high incineration efficiency, reasonable process, leading technology, and high degree of harmfulness. It is an ideal garbage disposal equipment for all kinds of hospitals, hotels, stations, large commercial institutions, enterprises, and public institutions. Main features: 1. Gasification incineration technology is applied to the incineration of syringes, drip containers and other medical equipment as well as all kinds of paper waste, bandages, absorbent cotton, all kinds of medical sewage and all kinds of waste discharged by hospitals and medical institutions. 2. Using gasification incineration method, the waste generated every day can be incinerated once. 3. The use of gasification incineration, mixed incineration, burnout treatment and other technologies, so that the exhaust smoke, soot content is lower than the national emission standards. 4. Fully enclosed operation, suitable for the treatment of infectious medical waste, to avoid secondary pollution. 5. Small size, small footprint. 6. The series of incinerators are divided into fuel oil and gas, and users can use different types according to their needs. Technical characteristics of incinerators LDF series medical waste incinerator adopts the most advanced incineration method of primary pyrolysis gasification + wind cocombustion + secondary incineration + burnout treatment. The design of the primary combustion chamber of the incinerator adopts the gasification incineration technology to make the temperature in the incinerator shift from 200ºC to 400ºC, and the waste will not produce frit, slag, sintering and other problems in the incineration process. Compared with direct combustion furnace and other furnaces, the dust production of gasification incinerator is very small, and secondary combustion burners and circumferential air supply devices are installed in the secondary mixed incineration chamber. At high temperatures, the combustible gas in the flue gas can be fully burned, and the gas produced by the gasifier can be fully mixed with the air to burn efficiently, preventing the carbon in the gas flame from escaping and the occurrence of late burning. When the flue gas enters the high temperature burnout chamber, due to the use of tangential entry and tangential entry of combustion-supporting air, the flue gas can be fully burned again in the burnout chamber, and the use of rotating airflow for flue gas dust removal. The residence time of the incinerator flue gas in the furnace is greater than 2 seconds, so that the combustible gas in the flue gas and the combustible matter in the fly ash are completely incinerated. The upper part of the incinerator is equipped with dry tail gas purification equipment to adsorb hydrogen chloride and sulfur oxides produced in the incineration, and the odor and other components in the flue gas are decomposed at high temperature. The flue gas purification system is equipped with calcium hydroxide filter brick for neutralizing reaction with acid gas to achieve the purpose of adsorption of acid gas and purification of tail gas. The harmful components in the flue gas are reduced to the national "Hazardous Waste incineration Pollution Control Standard (GB18484-2001)" and other standards below the specified value. The operation control of the incinerator adopts automatic program control, which reduces the labor degree of the workers, and the design of the furnace door and ash cleaning door adopts the fully sealed structure in the form of the child and the mother. During the incineration, the furnace is completely isolated from the outside of the furnace, forming negative pressure combustion, which eliminates the possibility of secondary pollution, especially the treatment of infectious dangerous medical waste, which can highlight its unique advantages.
STERIPLUS 20
On-site infectious risk waste treatment solution
https://youtu.be/ahPvNNrzIMk?si=4J0p2LaJwPRq2O2k
Features

Compact

The smallest machine in our range STERIPLUS™, the STERIPLUS™ 20 offers an efficient solution for on-site waste treatment.

Suitable for small and medium spaces

It can be easily installed in a small room. It is perfectly adapted to small and medium structures, such as laboratories or medical centres.

Economic

The STERIPLUS™ 20 is very energy-efficient and does not require much water.  
Technical Data
LOADING CHAMBER CAPACITY 20 L
LOADING CHAMBER USEFUL DIMENSIONS (W x D x H) 320 x 247 x 273 mm
LOADING CAPACITY (containers) 1 X TESABOX  20
TOTAL CYCLE TIME (NF X30-503-1 standard) (1) 30 to 35 min
TOTAL CYCLE TIME in working conditions (2) 30 to 50 min.
LOADING CAPACITY (KG/CYCLE) 1,6 to 2,4 kg/cycle - Based on an average waste density of 0,08 to 0,12kg/L for Healthcare Waste 2,4 to 4 kg/cycle - Based on an average waste density of 0,12 to 0,2kg/L for Lab/Humid/Liquid Waste
TREATMENT CAPACITY (KG/H) (3) 2 to 3 kg/h - Based on an average waste density of 0,08 to 0,12kg/L for Healthcare Waste 3 to 5 kg/h - Based on an average waste density of 0,12 to 0,2kg/L for Lab/Humid/Liquid Waste
MAX QUANTITY OF LIQUID RECOMMENDED PER CYCLE (4) 6 L
EXTERNAL DIMENSIONS (w x d x h) 1300 x 895 x 1210 mm
NET WEIGHT 530 kg
LOADING CHAMBER Stainless steel with PTFE coating
TREATMENT CHAMBER AISI 304L stainless steel
STEAM GENERATOR AISI 304L stainless steel (chamber) & Highly corrosion-resistant Hastelloy®
WATER SOFTENER Optional (external)
WATER BOOSTER PUMP AND AIR COMPRESSOR Built-in
WASTE SHREDDER Structure: AISI 304L stainless steel & Blades: High-strength steel
PIPING Stainless steel/PTFE flexible hosing
CHASSIS Painted steel
BODYWORK Composite material / Painted steel
CYCLE TRACEABILITY - THROUGH PRINTOUT Built-in
USB PORT Built-in
Utilities
 
WATER
Requirements Softened water (4-8°TH)
Consumption 5 liters / cycle
ELECTRICITY
Requirements 380-400 V III N, 50Hz/60Hz, 10 kW
Consumption 1 kW/h / cycle
DRAIN ø 32 mm internal (heat-resistant)
STEAM/COMPRESSED AIR Produced by the integrated steam generator and air compressor; no external connection required.
 

Accessories

           
Features
  • Sharps Safety Box
  • Bio-degradable board material
  • Sharp aperture to receive Syringes, Needle Assemblies of all standard sizes up to 20ml, and other sharps.
  • Possible to close and seal the aperture at any time during use.
  • Lifting Handle.
  • Maximum filling line marking
  • Stable, spill-proof & damage resistant.
  • Pictorial instructions to use.
  • Meets WHO Standards: WHO/PQS/E10/SB01.1
Applications:
  • Government & Private Hospitals

  • Immunization Campaigns

  • Blood Collection Drives

  • Community & Primary Health Centres

  • Disaster Relief and Emergency Camps

  • Mobile Medical Units

  • Research & Diagnostic Labs

Specifications:
Specification Details
Product Name ARVS Cardboard Safety Box – 4 Ply
Material 4 Ply Corrugated Cardboard
Capacity Options Typically 5L, 10L, or 15L (based on model)
Design Foldable with locking flap lid
Puncture Resistant Yes – suitable for sharp waste
Closure Type Tamper-proof top flap
Color Kraft or printed with biohazard labels
Usage Type One-time use, disposable
Regulatory Compliance WHO, CPCB, Biomedical Waste Management Rules
Features:
  • 3 Litre Capacity: Balanced size for moderate sharps disposal.

  • High-Density Polypropylene Body: Puncture-proof and leak-resistant.

  • Secure Locking Lid: Snap-fit lid with temporary and permanent lock.

  • Wide Mouth Opening: Easy disposal of multiple or bulky sharps.

  • Integrated Needle Remover: Hands-free detachment from syringes.

  • Stackable Design: Saves space in clinics or storage areas.

  • Biohazard Labeling: Clear markings for safe identification.

  • Portable & Lightweight: Convenient for use in mobile care units.

Specifications:
Specification Details
Product Name Sharps Container – Nursy Series 3 Ltr
Material Medical-Grade Polypropylene (PP)
Capacity 3 Litres
Lid Type Snap-on lid with temporary & permanent lock
Puncture Resistant Yes
Leak-Proof Yes
Color Options Yellow or Red with biohazard labeling
Dimensions Approx. 20–24 cm (H) × 16–18 cm (W)
Compliance WHO, CPCB, and biomedical waste guidelines
Labeling Biohazard symbol and usage instructions
Features:
  • 0.8 Litre Capacity: Suitable for low to moderate sharps disposal needs.

  • Durable Polypropylene Material: Puncture-resistant and leak-proof for safety.

  • Temporary & Final Lock Lid: Prevents accidental opening and ensures permanent closure after use.

  • Needle Remover Slot: Integrated feature for hands-free needle removal.

  • Color-Coded Biohazard Design: Yellow/red color with biohazard marking for easy identification.

  • Portable & Stackable: Easy to carry, store, and transport.

  • One-Hand Operation: Enables safe disposal using only one hand.

Specifications:
Specification Details
Product Name Sharps Container – PBS Series 0.8 Ltr
Material Medical-Grade Polypropylene (PP)
Capacity 0.8 Litres
Lid Type Snap-on with temporary and permanent lock
Puncture Resistance Yes
Leak-Proof Yes
Color Options Yellow or Red (Biohazard-labeled)
Dimensions 13–15 cm (H) × 10–12 cm (W)
Compliance WHO, CPCB, and biomedical waste disposal norms
Labeling Printed with biohazard symbol and instructions
Features
  • The body is made of ABS Plastic
  • Syringe Hub & Needle gets cut off by a sharp blade by pulling the handle.
  • Separate holes for inserting the Needle & Syringe hub.
  • No electricity required
  • Economical & Reusable
  • Capacity – 500 ml
  • Dimensions – L 8.8 cm x dia x H 11.8 cm
  • Weight – 150 grams
Typical Use Case:
  1. Insert the used needle into the cutter slot.

  2. Press or twist the handle to cut.

  3. The needle drops into a secure container.

  4. Dispose of the container as per biomedical waste guidelines once full.

Benefits:
  • Prevents cross-contamination and infections.

  • Reduces the volume of sharps waste.

  • An environmentally friendly alternative to burning or open disposal.

WeightN/AN/AN/AN/AN/AN/A
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • Rating
  • Price
  • Description
Click outside to hide the comparison bar
Compare