Description | Shipped From Abroad
Features
C, F and C & F are available.
Range: 35-42 °C / 94-108 °F
Accuracy: 0.1 in °C scale/ 0.2 in °F scale
GCDE100101
Oral Use & Rectal Use
Blue or red color plastic box and yellow pen type plastic box are available.
GCDE100401
Armpit Use, medium size
GCDE100501
Armpit Use, large size
Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| In Stock
- Adult Velcro Cuff for maximum arm circumference of 34.3cm
- Made in UK & guaranteed accurate to BS EN 1060 – 1
- Lightweight diecast case
- Shatter-proof plastic manometer tube
- Mercury reservoir with isolation valve
- Steel hinge pivots
- Range 0 – 300mmHg
- Supplied with adult size cuff & latex-free bulb
Delivery & Availability:
Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | In stock
- Made of medical grade Silicone, have good biocompatibility, non-toxic.
- Exclusive soft seal cuff can be insert comfortable, minimizing potential trauma and increasing sealing.
- Strengthen neck and tip eases insertion and prevents folds.
- Kink-free tube eliminates the risk of airway tube occlusion.
- Have different size, suitable for neonate, infant, child and adult.
- Different color cuff, different material cuff, with aperture bar or not.
- Reusable types must be cleaned and disinfected or sterilizated before use only 40 times.
Delivery & Availability:
Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | In stock
Delivery & Availability:
Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | In stock
Ambu Bag with Reservior: The ventilation bag is highly reactive with fast recoil and excellent stroke volume which help relieving fatigue to the rescuer. The thin-walled compression bag provides an excellent feel of lung compliance and helps avoid excessive ventilation that could damage the lungs.
Delivery & Availability:
Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | Shipped from Abroad
TouchTymp MI 36 combines diagnostic middle ear analyzer and audiometry tests in one exceptional device. The full 10.4" touchscreen with its user-friendly interface guarantees a unique intuitive operation and allows to quickly change parameters. You can easily switch between the tests without reorganizing from one to another device and beneft from its small footprint when facing limited desk space. touchTymp MI 36 really improves your workflow every day.
Delivery & Availability:
Typically 10 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. |
Content | Product Codes
REF |
Description |
Qty.Cs |
GCDE100101 |
Oral use, long bulb, white back, prismatic type |
720 |
GCDE100102 |
Oral use, long bulb, yellow back, prismatic type |
720 |
GCDE100201 |
Rectal use, short bulb, white back, prismatic type |
720 |
GCDE100202 |
Rectal use, short bulb, yellow back, prismatic type |
720 |
GCDE100401 |
Oval type, white back, round shape plastic box |
720 |
GCDE100501 |
White back |
720 |
|
- Adult Velcro Cuff for maximum arm circumference of 34.3cm
- Made in UK & guaranteed accurate to BS EN 1060 – 1
- Lightweight diecast case
- Shatter-proof plastic manometer tube
- Mercury reservoir with isolation valve
- Steel hinge pivots
- Range 0 – 300mmHg
- Supplied with adult size cuff & latex-free bulb
|
Features:
- Made of medical grade Silicone, have good biocompatibility, non-toxic.
- Exclusive soft seal cuff can be insert comfortable, minimizing potential trauma and increasing sealing.
- Strengthen neck and tip eases insertion and prevents folds.
- Kink-free tube eliminates the risk of airway tube occlusion.
- Have different size, suitable for neonate, infant, child and adult.
- Different color cuff, different material cuff, with aperture bar or not.
- Reusable types must be cleaned and disinfected or sterilizated before use only 40 times.
| |
Ambu Bag with Reservior: The ventilation bag is highly reactive with fast recoil and excellent stroke volume which help relieving fatigue to the rescuer. The thin-walled compression bag provides an excellent feel of lung compliance and helps avoid excessive ventilation that could damage the lungs.
Features:
- Brand: OEM
- Item No.: AM-DMR-M06-0/1/4
- Color: Green
- Size: Adult/Pediatric/Infant
- Material: Disposable
- Application: Emergency Resuscitation
- MOQ: 300
- Lead Time: 60 days
- Shipping Terms: FOB
- Packaging Details: Each set is packed into a white PP box
- Carton Size: 57 x 34 x 46 CM / 12 SETS
- Shipping Weight: 9.8 Kilos
Technical Specifications:
Type |
Infant |
Pediatric |
Adult |
Patient weight |
≤10kg |
10kg-40kg |
>40kg |
Stroke volume |
150ml |
400ml |
800ml |
Resuscitator volume |
280ml |
600ml |
1650ml |
Dimensions L x D |
135 x 75mm |
146 x 100mm |
212 x 131mm |
Resuscitator weight |
350g |
410g |
600g |
Pressure limiting valve |
40cmH2O |
40cmH2O |
60cmH2O |
Inspiratory resistance |
<5cmH2O (at 50L/min) |
Expiratory resistance |
<5cmH2O (at 50L/min) |
Bag volume |
1600ml |
1600ml |
2000ml |
Patient connector |
ISO5356-1:φ22/15mm Male/Female |
Recommended operating temperature |
-18℃~+50℃ |
Storage |
Tested at -40℃ and 60℃ |
| TouchTymp MI 36 combines diagnostic middle ear analyzer and audiometry tests in one exceptional device. The full 10.4" touchscreen with its user-friendly interface guarantees a unique intuitive operation and allows to quickly change parameters. You can easily switch between the tests without reorganizing from one to another device and beneft from its small footprint when facing limited desk space. touchTymp MI 36 really improves your workflow every day.
FEATURES AT A GLANCE
- Combo device with small footprint
- Customizable to suit individual needs
- High resolution and quick screen transitions
- Full touch-based interface for intuitive handling
- Probe tone 226 Hz, 678 Hz, 800 Hz
- Optional high-frequency probe tone 1 kHz
- Acoustic reflex stimuli 500 Hz,1 kHz, 2 kHz, 4 kHz, BB, HP, LP (ipsilateral and contralateral)
- Reflex Decay test (ipsilateral and contralateral)
- ETF test for intact and perforated eardrums
- Air conduction audiometry
- Bone conduction audiometry
- Built-in printer or data transfer to PC
- Optional MAICO Sessions PC Software connectable with OtoAccess® or Noah patient database for easy data management
Comprehensive test protocols
- Our touchTymp MI 36 provides comprehensive standard protocols for immediate operation of screening and diagnostic test processes: tympanometry with 226 Hz, tympanometry with automatic or fxed acoustic reflexes, reflex decay, Eustachian tube function testing (ETF) plus air conduction and bone conduction audiometry. The optional high-frequency probe tone of 1 kHz is ideal for providing reliable results when testing newborns
Stay focused on your patients
- The unique touchTymp light bar on our shoulder box probe provides a real-time progression of the immittance test. The shoulder box can easily be clipped to your patient's top for controlled handling of the diagnostic probe. The light indicator shows you which ear is tested and the test result.
Printing made easy
- Print test results instantly by using the touchTymp built-in printer. Place the shoulder box into its holder to automatically start printing. You can transfer the results to a PC to allow long term storage, full page printout and PDF creation for EMR integration.
Compatible to Sessions: Get ready for fast data transfer!
- Use the touchTymp MI 36 with our intuitive data transfer solution Sessions, for easy management and visualization of your immittance measurements.
TECHNICAL SPECIFICATION
Tympanometry
- Probe Frequency - 226 Hz ± 1 %, 85 dBSPL ± 1.5 dB, 678 Hz ± 1%, 72 dBSPL ± 1.5 dB, 800 Hz ± 1%, 70.5 dBSPL ± 1.5 dB
- Optional High Frequency - 1 kHz ± 1%, 69 dBSPL ± 1.5 dB
- Pressure Range - -600 to + 400 daPa
- Accuracy of Pressure - ± 5 % or ± 10 daPa
- Volume Range - 0.0 to 6.0 ml (compensated)
- Compliance Range - 0.1 to 8.0 ml at 226 Hz, 0.1 to 15.0 mmho at 678, 800 and 1000 Hz
- Accuracy of Volume - ± 5 % or 0.1 ml
- Test Time Measurement - 3 - 5 seconds
Acoustic Reflexes
- Test Frequencies - 0.5, 1, 2, 4 kHz ± 1 %
- Test Noise - BB, LP, HP
- Test Methods - Ipsilateral, contralateral
- Level Ipsilateral - 70 to 105 dBHL
- Level Contralateral - 70 to 120 dBHL
- Level Setting - Automatic, fxed
- Ipsilateral Reflex - Test With AGC
Reflex Decay
- Standard - Probe frequency 226 Hz
- Test Frequencies - 0.5, 1, 2, 4 kHz ± 1 %
- Test Noise - BB, LP, HP
- Level Ipsilateral - 70 to 105 dBHL
- Level Contralateral - 70 to 120 dBHL
Eustachian Tube Function
- Test Methods - Intact and perforated
- Pressure Range - -600 to + 400 daPa
Audiometry
- Test Signals - Sinus and warble tone, (pulsed and continuous)
- Test Frequencies - 125, 250, 500, 750, 1000, 1500, 2000, 3000, 4000, 6000, 8000 Hz (125 Hz excluded
- from bone conduction test frequencies)
- Level Steps - 5 or 1 dB
- Hearing Level Range AC - -10 to 120 dBHL
- Hearing Level Range BC - -10 to 80 dBHL
- Masking Noise - Narrow band and white noise
Device General
- Display - 10.4" Graphic LED-Display with resistive touchscreen
- PC Interface - USB
- Probe - Lightweight diagnostic Shoulder-Box with built-in control light and switch
- Printer - Fast 4 inch thermal printer
- Power Supply - Mains 100 to 240 V~ ± 10 %, 50 - 60 Hz ± 10 %
- Dimensions / Weight - W 30 x D 34.5 x H 14.8 cm / 3.2 kg
- Languages - English, German, Spanish, French, Polish, Turkish, Russian, Chinese
|
Reviews
There are no reviews yet.