Purpose:
Determination of the filtration coefficient according to GOST 19006-73
Applied in organizations controlling quality of fuels and lubricants, in petroleum refining industry, in oil products distribution system.
Shall be used to test the filtration coefficient of motor fuels according to GOST 19006-73.
The device shall be assembled and the filtration coefficient shall be tested according to GOST 19006-73.

Delivery & Availability:
Typically 14-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.

SF1033560103
Brands:: ECROSKHIM

Description

Purpose:
Determination of the filtration coefficient according to GOST 19006-73
Applied in organizations controlling quality of fuels and lubricants, in petroleum refining industry, in oil products distribution system.
Shall be used to test the filtration coefficient of motor fuels according to GOST 19006-73.
The device shall be assembled and the filtration coefficient shall be tested according to GOST 19006-73.

Scope of delivery:
1. Graduated glass tube cut from a burette 1-2-50-0.1, according to GOST 20292-74 in a metal mount, and an extension made of Caprolon in its top – 1 pc.
2. Glass or metal cock in a mount of a filtering device – 1 pc.
3. Filter mount – 1 pc.
4. Filter seat – 1 pc.
5. Gasket 1x17x19 – 2 pcs.
6. Gasket 1x15x17 – 2 pcs.
7. Filter paper, BFDT brand, with the screening fineness not exceeding 3µm (0.33+/-0.03) mm thickness, the number of analyses – 50 pcs.
8. Volumetric flask 1-50-2, 50 cm3, according to GOST 1770-74 – 1 pc.
9. Beaker V or N, version 1 or 2, 400 or 600 cm? capacity, according to GOST 25336-82 (made of glass or polypropylene) – 1 pc.
10. Cylinder 1-50 or 3-50, according to GOST 1770-74 – 1 pc.
11. GOST 19006-73 – 1 pc.
12. Operating manual – 1 pc.
13. Storage case – 1 pc.

Review(1)

0 average based on 0 ratings.
  1. vorbelutr ioperbir

    I do not even know how I ended up right here, but I assumed this submit was once great. I don’t recognize who you might be however definitely you’re going to a famous blogger when you are not already 😉 Cheers!

Add a review

Your email address will not be published. Required fields are marked *

Quick Comparison

SettingsMotor Fuel Filtering Factor Tester UOVT-01 removeSkyla HB1 POC Clinical Chemistry Auto Analyzer removeSugentech Inclix (POCT) Immunoassay Analyzer removeZenithlab (IB-9025A) Laboratory Incubator removeDiscover 14 Panel Cup with Adulterants Per Pack removeAvalun LabPad Device remove
NameMotor Fuel Filtering Factor Tester UOVT-01 removeSkyla HB1 POC Clinical Chemistry Auto Analyzer removeSugentech Inclix (POCT) Immunoassay Analyzer removeZenithlab (IB-9025A) Laboratory Incubator removeDiscover 14 Panel Cup with Adulterants Per Pack removeAvalun LabPad Device remove
ImageDrug Test CupAvalun Labpad machine
SKUSF1033560103SF1033560060-1SF1033560084-89SF1033560084-109SF1033560084-28SF1033560084-65
Rating
Price

$0.00

$0.00

$0.00

$350.00

$0.00

$0.00

Stock
Availability
Add to cart

DescriptionShipped From Abroad
Purpose: Determination of the filtration coefficient according to GOST 19006-73 Applied in organizations controlling quality of fuels and lubricants, in petroleum refining industry, in oil products distribution system. Shall be used to test the filtration coefficient of motor fuels according to GOST 19006-73. The device shall be assembled and the filtration coefficient shall be tested according to GOST 19006-73. Delivery & Availability: Typically 14-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped from Abroad The skyla HB1 Clinical Chemistry Analyzer provides clinical testing laboratories of medical facilities and clinics with an in-vitro clinical chemistry diagnostic tool that is compact, portable, and reports rapid results. The portable design of the clinical chemistry analyzer utilizes precision photometric measurement technology, combined with the single-use disposable reagent discs. The reagent disc contains a set of dry assay reagents that are used in the quantitative testing of various biomarkers in the blood sample. Delivery & Availability: Typically 14 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.In stock INCLIX™ is an immunochromatographic analyzer providing immediate point-of-care testing (POCT) at patient care settings or clinical laboratories. It facilitates automatic detection of various biomarkers for cardiovascular disease, infectious disease, cancer, diabetes, allergy, and etc. with high accuracy and sensitivity. INCLIX™ analyzer is a compact, easy-to-use and cost-effective multi-parameter POCT instrument and its unique user friendly software provides an efficient data management system. Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.In stock
  • Microprocessor control.
  • Digital display setting and actual temperature.
  • Over temperature alarm, PID self-tuning.
  • Digital display running timer.
  • Stainless steel interior.
  • Electricity leakage protection.
  • With glass inner door, With hidden door locks.
  • Mechanical overheat protection, cut off the heating sources.
  • Automatic alarm after operation.
  • Suitable for constant temperature tests.
  • Suitable for bacteria cultivation, breeding, ferment.
Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock
The Discover Cup is an all-in-one drug of abuse test cup. The strips are self contained and the entire cup is tamper resistant. Delivery & Availability:
Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock The coagulometer, LabPad® INR, measures blood coagulation time thanks to a patented optical technology. This portable In-Vitro Diagnostics (IVD) device works with the Tsmart® INR single-use microcuvettes. Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
ContentPurpose: Determination of the filtration coefficient according to GOST 19006-73 Applied in organizations controlling quality of fuels and lubricants, in petroleum refining industry, in oil products distribution system. Shall be used to test the filtration coefficient of motor fuels according to GOST 19006-73. The device shall be assembled and the filtration coefficient shall be tested according to GOST 19006-73. Scope of delivery: 1. Graduated glass tube cut from a burette 1-2-50-0.1, according to GOST 20292-74 in a metal mount, and an extension made of Caprolon in its top – 1 pc. 2. Glass or metal cock in a mount of a filtering device – 1 pc. 3. Filter mount – 1 pc. 4. Filter seat – 1 pc. 5. Gasket 1x17x19 – 2 pcs. 6. Gasket 1x15x17 – 2 pcs. 7. Filter paper, BFDT brand, with the screening fineness not exceeding 3µm (0.33+/-0.03) mm thickness, the number of analyses – 50 pcs. 8. Volumetric flask 1-50-2, 50 cm3, according to GOST 1770-74 – 1 pc. 9. Beaker V or N, version 1 or 2, 400 or 600 cm? capacity, according to GOST 25336-82 (made of glass or polypropylene) – 1 pc. 10. Cylinder 1-50 or 3-50, according to GOST 1770-74 – 1 pc. 11. GOST 19006-73 – 1 pc. 12. Operating manual – 1 pc. 13. Storage case – 1 pc.
Skyla HB1 Clinical Chemistry Analyzer utilizes precision photometric measurement technology, combined with the single-use disposable reagent discs. The reagent disc contains a set of dry assay reagents that are used in the quantitative testing of various biomarkers in the blood sample. HB1 provides clinical testing laboratories of medical facilities and clinics with an in-vitro clinical chemistry diagnostic tool that is compact, portable, and reports rapid results. Only needs 200µl of blood (whole blood, serum or plasma is accepted.) and no sample preparation is required. All steps are designed automatically from checking the validity of reagent discs and cartridges to printing the results. Over 30 test parameters are allowed with fast analysis and results in 15 minutes. Internal Quality Control (IQC) with self-calibration of optical system, chemicals stability and interference alerts functions monitor and ensure the results with high accuracy. Available Test Panels
  • Renal Function - BUN, CREA eGFR
  • Liver Function - ALB, TP, ALP, ALT, AST, TBIL, DBIL, GGT, LDH A/G#, GLOB#, IBIL
  • Lipid Metabolism - TG, TC, HDL LDL#, VLDL
  • Pancreatitis Markers - AMY, LIPA
  • Carbohydrate Metabolism and Others - GLU , CPK, UA, LAC
  • Inflammatory Markers - CRP
  • Electrolyte - Na, K, Cl, Ca, PHOS, Mg, tCO2
SPECIFICATION Principle
  • Colormetric System : LEDs 340nm~940nm wavelength
Sample & Panel
  • Test Profiles : Panels
  • Measurement Time - Panel: up to 15 tests/ 15 min
  • Sample Type & Volume : 200 μl whole blood (PCV<60%), plasma, serum 
Device
  • User Interface : 5 inch color LCD touch screen
  • Internal Memory : Store up to 50,000 analysis results
  • Printer : Built in thermal printer or external USB printer (PCL 3GUI)
  • USB Socket : USB type A (Host) for external USB Printer, USB flash drive (FAT) or external barcode scanner
  • Data transmission to PC : RS232 serial port or RJ45 (LAN)
  • Dimensions : 233 (W) X 285 (D) X 300 (H) mm
  • Weight : 5.5 kg
Operating Condition
  • Temperature / Humidity : 10 to 32ËšC / 5 to 90 %
 
Click Here To Download Catalogue
INCLIXâ„¢ is an immunochromatographic analyzer providing immediate point-of-care testing (POCT) at patient care settings or clinical laboratories. It facilitates automatic detection of various biomarkers for cardiovascular disease, infectious disease, cancer, diabetes, allergy, and etc. with high accuracy and sensitivity. INCLIXâ„¢ analyzer is a compact, easy-to-use and cost-effective multi-parameter POCT instrument and its unique user friendly software provides an efficient data management system. Features: • Good accuracy owning to superior CMOS sensor & our own Algorism • 10,000 test results data storage • Instrument Check by Reference Kit • Remote Support available (when connected via Internet) • Built-in Thermal Printer and Barcode Scanner • Data export to USB(PDF, Excel), Email and LIS • Storage Temperature of Test Cassette & Buffer : Room temperature, 2 ~ 30 ℃ • Shelf Life of Test Cassette & Buffer : 24 months  
Click Here To Download Catalogue
 
Features:
  • Microprocessor control.
  • Digital display setting and actual temperature.
  • Over temperature alarm, PID self-tuning.
  • Digital display running timer.
  • Stainless steel interior.
  • Electricity leakage protection.
  • With glass inner door, With hidden door locks.
  • Mechanical overheat protection, cut off the heating sources.
  • Automatic alarm after operation.
  • Suitable for constant temperature tests.
  • Suitable for bacteria cultivation, breeding, ferment.
  Technical Specification: Model: IB-9025A Working size: 250x250x250mm/9.84x9.84x9.84inch Power: 150W Temperature range: Room temperature+5~65℃ Temperature resolution: 0.1℃ Temperature fluctuation: ±0.5℃ Timer: 0-9999min Voltage: 110V 60Hz / 220V 50Hz Dimension: 380x370x580mm/14.96x14.57x22.83inch Size: 52cm*46cm*75cm / 20.5in*18.2in*29.6in Gross Weight:42kg / 93lb Net Weight: 23kg / 51lb Warranty: 1 year
All-in-One Design
FDA 510(K) & CLIA Waived Up to 99% accuracy rate Results in as little as 1 minute 24 Month Shelf Life from Date of Manufacture Secure, seal and send to lab for confirmation Built in temperature strip Available to test up to 17 substances with adulterants or 18 without adulterants Adulterants available
 
 
The coagulometer, LabPad® INR, measures blood coagulation time thanks to a patented optical technology. This portable In-Vitro Diagnostics (IVD) device works with the Tsmart® INR single-use microcuvettes.
  • User-friendly: the LabPad® INR is designed to be easy to use especially thanks to its 3D-shaped microcuvette that only requires a small drop of blood from a fingertip. Thanks to the color screen, both measurement steps and browsing the list of results are easy to visualize.
  • Quick and reliable: the reliability of INR results is obtained by quality controls that are performed automatically before each measurement. In less than one minute, you can see if you are in your therapeutic range.
  • Connected: the result obtained after performing the test can be transferred to healthcare professionals in charge of your treatment monitoring. This result is complementary to the pie charts and trend reports directly displayed on the LabPad® INR to help you monitoring your treatment
 