/ /

Multigas Monitor AneSure Mini

$1,815.00

Shipped From Abroad

AneSure Mini can simultaneously measure anesthetic gas, ETCO2, and respiratory rate. Suitable for Emergency, Pre-hospital, and Intra-hospital transport, Operating room as well as ICU.

Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Brands:: Kingst

Description

Features of AneSure Portable Multigas Monitor AneSure Mini
  • Portable And Lightweight

Suitable for emergency, pre-hospital, and intra-hospital transfer, operating room, and ICU, enhancing the safety of anesthesia

  • Alarm For Data Overrun And Suffocation

Quick warm-up with the first value displayed in 5 seconds, and accurate readings displayed in 15 seconds. 24-hour trend graphs, not lost when power off

  • Large Character Mode

The data can be seen from 5 meters away;

Turn on the unit, and it is ready to use instantly with no need to calibrate;

Automatic atmospheric pressure compensation; Economical adapters reduce usage costs.

  • Firm And Durable

Suitable for various medical environments (field, helicopter, etc.)

 

Specifications of AneSure Portable Multigas Monitor AneSure Mini
AC Input 100V -240V, 50Hz/60 Hz to 5VDC Adapter with 5V type-C USBadapter Cable.
Battery Built-in rechargeable lithium battery pack (3.7V, 1200mAH)
Temperature 5 to +50℃
Humidity ≤80%
Atmospheric pressure 55 – 115 kPa
Technique NDIR (Non-dispersive infrared gas analysis)
Sampling Mode Mainstream
EtCO2, FiCO2 measurement Range: 0 – 150mmHg or 0 – 20kPa or 0 – 19.7% (v/v)

Accuracy: ±2mmHg for CO2 range 0 – 40mmHg

±5% for CO2 range from 41 – 70mmHg

±8% for CO2 range from 71 – 100mmHg

±10% Over 100mmHg

Update/Averaging Time Option of every breath or 10, 20 or 30 seconds
FiN2O/EtN2O measurement Range: 0-100%

Accuracy: ± (2 vol% + 2% of reading)

FiHAL/EtHAL, FiENF/EtENF, FiISO/EtISO measurement Range: 0-12%

Accuracy: 0-8%: ± (0.15 vol% + 5% of reading); 8-12%: unspecified

FiSEV/EtSEV measurement Range: 0-15%

Accuracy: 0-10%: ± (0.15 vol% + 5% of reading); 10-15%: unspecified

FiDES/EtDES measurement Range: 0-25%

Accuracy: 0-18%: ± (0.15 vol% + 5% of reading); 18-25%: unspecified

All FiAG Update: every 2-3 breath

Trends: 24 hours on Screen Trend and Numeric

Atmospheric Pressure Compensation Auto-compensation for atmospheric pressure variation
Respiration Rate Range: 3 – 150 breaths/minute

Accuracy: ±1% of reading or ±1 breaths/min whichever is greater

Rise time CO2 is less than70ms;

N2O is less than300ms; Anesthetic gases (halothane, enflurane, isoflurane, sevoflurane, or desflurane) are less than 300ms

Warm Up Time <15 seconds
Agent threshold 0.2%, When an agent is identified, concentrations will be reported even below 0.2% as long as apnea is not detected
Alarm limits Apnea alarm limits:15-40 sec

High alarm limits EtCO2/ FiCO2:22-150mmHg

Low alarm limits EtCO2/ FiCO2: 00-60mmHg

High alarm limits FiHAL/EtHAL, FiENF/EtENF, FiISO/EtISO:1.0-8.0%

Low alarm limits FiHAL/EtHAL, FiENF/EtENF, FiISO/EtISO:0-6.5%

High alarm limits FiSEV/EtSEV:1.0-10.0%

Low alarm limits FiSEV/EtSEV:0-6.5%

High alarm limits FiDES/EtDES:1.0-18.0%

Low alarm limits FiDES/EtDES: 0-6.5%

High alarm limits FiN2O/EtN2O:26-100%

Low alarm limits FiN2O/EtN2O: 01-78%

The high alarm limits of respiration rate:4-150 breaths/min

The low alarm limits of respiration rate:0-140 breaths/min

Size 38 x 42 x 44mm (W x H x D)
Weight 80g (including lithium battery and adult airway adapter)
Airway Adapter Dead Space: 5ml (Adult/Pediatric)

1ml (Neonate)

Warranty & Maintenance/ Calibration One-year warranty on the Main Unit and Lithium Ion Rechargeable Battery

 

Application Scenarios of AneSure Portable Multigas Monitor AneSure Mini
  • Portable, accurate, and real-time anesthetic multi-gas monitor
  • AneSure-Mini can simultaneously measure anesthetic gas, ETCO2, and respiratory rate. It is suitable for Emergency, Pre-hospital, and Intra-hospital transport, Operating room as well as ICU.
  • It has an alarm function, which will alarm when the measured value reaches the alarm limits or when suffocation occurs.
  • The first data can be obtained within 5 seconds after power-on, and full accurate data can be obtained within 15 seconds; the 24-hour Etco2 graph will not be lost when power is off.
  • It has a large-character display mode, and the data can be clearly seen from more than 5 meters away.
  • It is ready to use after the power is on.
  • With simple maintenance and a sturdy structure, suitable for various harsh environments.

Reviews

There are no reviews yet.

Be the first to review “Multigas Monitor AneSure Mini”

Your email address will not be published. Required fields are marked *

Quick Comparison

SettingsMultigas Monitor AneSure Mini removeRender SD-M2000A Anesthetic Machine removeTimesco Jumper Fingertip Pulse Oximeter removeDrip Stand removeRender SD-M2000B Anesthetic Machine removeLab/Ward Coat remove
NameMultigas Monitor AneSure Mini removeRender SD-M2000A Anesthetic Machine removeTimesco Jumper Fingertip Pulse Oximeter removeDrip Stand removeRender SD-M2000B Anesthetic Machine removeLab/Ward Coat remove
ImageFingertip Pulse Oximeter
SKUSF1033560011-13SF1033560084-2SF1033560084-67SF1033560011-10SF1033560084-222
Rating
Price

$1,815.00

$1,870.00

$17.00

$27.00

$4,840.00

$11.00

Stock
Availability
Add to cart

DescriptionShipped From Abroad AneSure Mini can simultaneously measure anesthetic gas, ETCO2, and respiratory rate. Suitable for Emergency, Pre-hospital, and Intra-hospital transport, Operating room as well as ICU.
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped from Abroad
  • Compact design
  • save space in O.R or Laboratory Room
  • High quality & Durability design
  • Easy operation & easy maintenance
  • New integrated respiratory circuit available with own patent
  • LED Ventilator inside & One standard ZF-1000 precise vaporizer
  • Optional: Two precise ZF-1000 vaporizers
Delivery & Availability: Typically 21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In Stock Integrated with SPO2 probe and processing display module. Small in volume、light in weight and convenient in carrying. Operation of the product is simple ,low power consumption. SPO2 , PR and Ridisplay,. Pulse rate value display, bar graph display. Low-voltage indication: low-voltage indicator appears before working abnormally which is due to low-voltage. Automatically power off function: when the device is under the state of measuring interface . it will automatically power off within 5 seconds if the finger falls out of probe. Delivery & Availability: Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.In stock Drip Stand is a very simple, easy to adjust and maneuver product. Suitable for most healthcare environments, this drip stand is light in weight made of high-quality stainless steel. Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.Shipped from Abroad
  • Contains Output interface for Anesthesia information management system.
  • Complete with backup battery for working more than 30 minutes.
Delivery & Availability: Typically 21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock
  • This white coat laboratory coat is a knee-length overcoat/smock is perfect for professionals in the medical field or by those involved in laboratory work.
  • This garment is Easy to wash and made from a cotton polyester blend, allowing it to be washed at high temperature and make it easy to see if it is clean.
  • Easy to wash.
Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Content
Features of AneSure Portable Multigas Monitor AneSure Mini
  • Portable And Lightweight
Suitable for emergency, pre-hospital, and intra-hospital transfer, operating room, and ICU, enhancing the safety of anesthesia
  • Alarm For Data Overrun And Suffocation
Quick warm-up with the first value displayed in 5 seconds, and accurate readings displayed in 15 seconds. 24-hour trend graphs, not lost when power off
  • Large Character Mode
The data can be seen from 5 meters away; Turn on the unit, and it is ready to use instantly with no need to calibrate; Automatic atmospheric pressure compensation; Economical adapters reduce usage costs.
  • Firm And Durable
Suitable for various medical environments (field, helicopter, etc.)  
Specifications of AneSure Portable Multigas Monitor AneSure Mini
AC Input 100V -240V, 50Hz/60 Hz to 5VDC Adapter with 5V type-C USBadapter Cable.
Battery Built-in rechargeable lithium battery pack (3.7V, 1200mAH)
Temperature 5 to +50℃
Humidity ≤80%
Atmospheric pressure 55 - 115 kPa
Technique NDIR (Non-dispersive infrared gas analysis)
Sampling Mode Mainstream
EtCO2, FiCO2 measurement Range: 0 – 150mmHg or 0 – 20kPa or 0 – 19.7% (v/v) Accuracy: ±2mmHg for CO2 range 0 - 40mmHg ±5% for CO2 range from 41 - 70mmHg ±8% for CO2 range from 71 - 100mmHg ±10% Over 100mmHg
Update/Averaging Time Option of every breath or 10, 20 or 30 seconds
FiN2O/EtN2O measurement Range: 0-100% Accuracy: ± (2 vol% + 2% of reading)
FiHAL/EtHAL, FiENF/EtENF, FiISO/EtISO measurement Range: 0-12% Accuracy: 0-8%: ± (0.15 vol% + 5% of reading); 8-12%: unspecified
FiSEV/EtSEV measurement Range: 0-15% Accuracy: 0-10%: ± (0.15 vol% + 5% of reading); 10-15%: unspecified
FiDES/EtDES measurement Range: 0-25% Accuracy: 0-18%: ± (0.15 vol% + 5% of reading); 18-25%: unspecified
All FiAG Update: every 2-3 breath Trends: 24 hours on Screen Trend and Numeric
Atmospheric Pressure Compensation Auto-compensation for atmospheric pressure variation
Respiration Rate Range: 3 - 150 breaths/minute Accuracy: ±1% of reading or ±1 breaths/min whichever is greater
Rise time CO2 is less than70ms; N2O is less than300ms; Anesthetic gases (halothane, enflurane, isoflurane, sevoflurane, or desflurane) are less than 300ms
Warm Up Time <15 seconds
Agent threshold 0.2%, When an agent is identified, concentrations will be reported even below 0.2% as long as apnea is not detected
Alarm limits Apnea alarm limits:15-40 sec High alarm limits EtCO2/ FiCO2:22-150mmHg Low alarm limits EtCO2/ FiCO2: 00-60mmHg High alarm limits FiHAL/EtHAL, FiENF/EtENF, FiISO/EtISO:1.0-8.0% Low alarm limits FiHAL/EtHAL, FiENF/EtENF, FiISO/EtISO:0-6.5% High alarm limits FiSEV/EtSEV:1.0-10.0% Low alarm limits FiSEV/EtSEV:0-6.5% High alarm limits FiDES/EtDES:1.0-18.0% Low alarm limits FiDES/EtDES: 0-6.5% High alarm limits FiN2O/EtN2O:26-100% Low alarm limits FiN2O/EtN2O: 01-78% The high alarm limits of respiration rate:4-150 breaths/min The low alarm limits of respiration rate:0-140 breaths/min
Size 38 x 42 x 44mm (W x H x D)
Weight 80g (including lithium battery and adult airway adapter)
Airway Adapter Dead Space: 5ml (Adult/Pediatric) 1ml (Neonate)
Warranty & Maintenance/ Calibration One-year warranty on the Main Unit and Lithium Ion Rechargeable Battery
 
Application Scenarios of AneSure Portable Multigas Monitor AneSure Mini
  • Portable, accurate, and real-time anesthetic multi-gas monitor
  • AneSure-Mini can simultaneously measure anesthetic gas, ETCO2, and respiratory rate. It is suitable for Emergency, Pre-hospital, and Intra-hospital transport, Operating room as well as ICU.
  • It has an alarm function, which will alarm when the measured value reaches the alarm limits or when suffocation occurs.
  • The first data can be obtained within 5 seconds after power-on, and full accurate data can be obtained within 15 seconds; the 24-hour Etco2 graph will not be lost when power is off.
  • It has a large-character display mode, and the data can be clearly seen from more than 5 meters away.
  • It is ready to use after the power is on.
  • With simple maintenance and a sturdy structure, suitable for various harsh environments.
  • Compact design
  • save space in O.R or Laboratory Room
  • High quality & Durability design
  • Easy operation & easy maintenance
  • New integrated respiratory circuit available with own patent
  • LED Ventilator inside & One standard ZF-1000 precise vaporizer
  • Optional: Two precise ZF-1000 vaporizers
 
Click Here To Download Catalogue
   
 
Integrated with SPO2 probe and processing display module • Small in volume, light in weight, convenient in carrying • Simple operation, lower power consumption • OLED screen display • SPO2, PR, bar graph of pulse, plethysmogram, blood perfusion index, battery indication display • 4 directions display, 6 display models, large fonts display • Brightness control, Demo mode, Setup menu • Movement interference • Alarm function and adjustable alarm parameters • Can be connected to mobile phones through Bluetooth; can support Android and iOS client • Auto power-off when no signal after 10s • Powered by 2*AAA alkaline batteries Specification: • Size: 62 x 37 x 32mm • Peak wavelength range of the light emitted from the probe: red light 660nm±3; infrared light 905nm±5 • Maximum optical output power of the probe: 1.2mW for infrared light (905nm) • Bluetooth module: 4.0 (single-mode) • Working temperature: 5℃ to 40℃ (41°F to 104°F) • Relative humidity: 15% to 80%, non-condensing • Atmospheric pressure: 70kPa to 106kPa • Rated voltage: DC 3V Package included: • 1 x JUMPER JPD-500F Bluetooth Fingertip Pulse Oximeter • 2 x AAA Batteries • 1 x Carry Case • 1 x Lanyard • 1 x English User Manual
Drip Stand is a very simple, easy to adjust and maneuver product. Suitable for most healthcare environments, this drip stand is light in weight made of high-quality stainless steel. Use : Bedridden patients, Senior citizen care, Patients in coma Advantages :
  • High quality stainless steel construction
  • Properly electroplated for anti rust finish
  • Ball shaped castors for smooth movement
  • Provided with an infusion stand
  • Attached 4 pcs hook
  • Maximum load strength
  • Screw safety height adjustment
  • Light weight
   
Features:
  • Contains Output interface for Anesthesia information management system.
  • Complete with backup battery for working more than 30 minutes.
  Technical Specifications:
Model: SD-M2000B
Brand: RENDER
Origin: Made In China
Category: Electronics & Electricity / Electronic Instrument / Electricity Meter & Instrument
Label: anesthesia machine , anesthesia ventilator , anesthesia machine
 
Click Here To Download Catalogue
 
  • This white coat laboratory coat is a knee-length overcoat/smock is perfect for professionals in the medical field or by those involved in laboratory work.
  • This garment is Easy to wash and made from a cotton polyester blend, allowing it to be washed at high temperature and make it easy to see if it is clean.
  • Easy to wash.
WeightN/AN/AN/AN/AN/AN/A
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • Rating
  • Price
  • Description
Click outside to hide the comparison bar
Compare