/

Neonatal Transport Incubator BLF-2001G

$0.00

Shipped From Abroad

Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
SF1033560130129-1
Brand:
Brands:: MEDICOR

Description

Neonatal Transport Incubator BLF-2001G

 

 

Features
  • Humidity servo (0-95%)
  • 3 litres distilled and residual water reservoirs
  • Air temperature servo control w/ override (25-39 oC)
  • Glass-like transparent single wall hood, x-ray compatible
  • Hood with front access door
  • Hood with 4 noiseless, easy to open hand ports / windows
  • Hood with 2 iris ports / windows
  • Hood with 6 tube ports
  • Cradle with anti-decubitus mattress, x-ray compatible
  • Space for x-ray cassette under the cradle
  • Mechanical one step cradle tilting, up to 12 degrees
  • Heavy duty stand with 4 castors (2 lockable)
  • Instrument shelf on the stand
  • Protector and instrument holder rails on each side
  • HEPA 13 air filter
  • State-of-the-art microprocessor controller
  • 5” bi-colour LCD display
  • Water resistant, foil-covered keypad with lock
  • Test button / Self test / Silence / Reset button
  • Display of heating intensity, date, set and actual values
  • 3/24/170 hours trends
  • Visual and audible alarms and backup sensors
  • Continuous self-test function during operation
  • Test button / Self test / Silence / Reset button
  • RS-232 connector
  • 230V/50Hz+/-10% (230V/60Hz or 110V/50-60Hz on request)
Properties
  • Exceptional Safety

The functions and operation of BLF-2001 incubators meet the requirements of IEC-601-2-19 product standard and those of the 93/42/EEC Directive. The materials used comply with the hygienic and toxicological requirements and are monitored continuously. The development, production and quality assurance of the incubators are performed in accordance with the ISO 13485 and ISO 9001 standards.
Alarm and warning details: High temperature / Ventilation fault / Temperature sensor fault (air sensor 1, air sensor 2, air sensor 3, skin sensor, second skin sensor, rectal sensor) / Humidifying / Technical fault / Mains fault / Low limit off / Low limit air / High limit air / – Acoustic and yellow or red colored messages/signs on the LCD in case of alarm or warming

  • Easy Access

The hood has six fully transparent windows (with iris opening upon request) and a large (upon request two) door(s). An X-ray cassette can be inserted under the cradle or on a cassette holder tray (optional). The cradle with the baby can be placed into an inclined position (even electrically upon request; optional), and the baby can be removed from the incubator safely and quickly together with the cradle.

  • Air Curtain

ln the hood the air streams along the longitudinal axis of the baby’s body. When the door is opened, an air curtain develops in the door. The hood of the unit may be single, double or triple walled (optional).

  • Easy Operation

The incubators are equipped with foil-covered keyboards and graphic LCD displays. Settings are easy to understand having the lowest possible number of controls. Set and real-time measured values are constantly shown on the LCD display.

  • Silent Operation

The noise level in the hood is below 45 dBA (40 dBA as option). The opening and closing of windows is absolutely noiseless. The air flow rate is well below the value allowed by the relevant standards.

  • Variable oxygen supply

Oxygen supply in the hood is controlled by a rotameter between 21-40% (optional). An electronic oxygen servo unit provides higher oxygen concentration for more intensity between 21-75% (optional). The incubators may be ordered also with head hood and with warmed humidified oxygen servo control (21-95%) (optional).

  • Comfort

ln the incubator, the baby’s weight is measured with high accuracy by an electronic scale located under the cradle, the measured value is shown on the graphic display, while data are stored (optional). The height of the lying surface can be made electronically adjustable upon request (optional).

  • Micro-computer control

BLF-2001 incubators are micro-computer controlled. When switched on, a hardware and software self-test is launched. Possible errors are indicated on the graphic display. The trends and values measured every 3 or 24 or 170 hours can be retrieved from the memory of the incubator. The incubator may be connected to an external computer (by means of a software programme to be purchased separately), enabling monitoring and remote control, as well as the saving and printing of measured values and trends (optional).

The display of the BLF-2001 incubator is easy to read even from distance, indicating the following data, depending on the configuration:

  • temperature of air in the hood
  • humidity of air in the hood
  • baby’s skin temperature (optional)
  • oxygen concentration (optional)
  • weight (optional)
  • second body temperature (optional)

The temperature control ranges of the incubator are as follows:

  • in normal mode of operation in the case of ‘air control’ 27-37°C in the case of skin control 34-36°C.
  • ln ‘override’ operation in the case of ‘air control’ 37-39°C, in the case of ‘skin control’ 36-38°C.

 

Technical data
PHYSICAL ATTRIBUTES (STANDARD VERSION)
Height / Packing 13 2/152 cm (52/60 in)
Width / Packing 85/95 cm (33/37 in)
Depth / Packing 60/70 cm (24/28 in)
Weight / Packing 70 kg (154 lbs)
Mains voltage 2 20/230V ± 10% (default), 110/120V ± 10% ( upon request)
Nominal frequency 50/60Hz
Nominal power consumption 420VA
Operating ambient temperature range +20°C – +30°C (68°F – 86°F)
Storage/transport ambient temperature range -40°C – 70°C (-40°F – 158°F)
Operating (Storage) ambient RH range 30% – 90% (10% – 100%)
Operating (Storage) air pressure range 700 hPa – 1060 hPa (500 hPa – 1060 hPa)
HOOD SPECIFICATIONS
Access door opening height 30 cm(12 in)
Mattress tray size 70 x 40 cm (27,6 x 15,75 in) / Optional 70 x 46 cm (27,6 x 18,11 in)
Mattress to hood height 36 cm (14 in) default, up to 45 cm (18 in) as option
Mattress size 70 x 40 cm (27,6 x 15,75 in) / Optional 70 x 46 cm (27,6 x 18,11 in)
TEMPERATURE CONTROL MODES
Temperature control modes Air (standard) / Skin (option)
Temperature display range (Air/Skin mode) 0.0°C (32.0° F) to 50.0°C ( 12 2.0°F)
Air mode control temperature range 0.0°C (68.0°F) to 37.0°C (98.6°F), in 0.1°C increments
Air mode control override temperature range 37.0°C (98.6° F) to 39.0°C (102.2° F), in 0.1°C increments
Skin mode control temperature range 34.0° ( (93.2° F) to 36.0° ( (96.8°F),
Skin mode control override temperature range 36.0° (96.8° F) to 38.0° (100.4° F), in 0.1°C increments
Peripherial skin / Rectal temperature monitoring Yes
PERFORMANCE
Air flow velocity across mattress under 10 cm/sec
Temperature rise time at 22 °C (72° F) ambient under 20 min
Temperature variability under 0.5°C (0.9°F)
Temperature uniformity on the surface of the mattress under 0.8°C (1.4°F)
Correlation of the indicated air temperature with the actual incubator temperature under 0.8°C (1.4°F)
Operating noise level in hood under 45 dBA (40 dBA as option)
Carbon Dioxide (CO) level (per EN60601-2-19) under 0,2%
Micro air intake filter HEPA 13 – 99 ,95%
Particle size removal 0.3 micron
HUMIDITY SERVO CONTROL
Humidity control range 30% to 95% in 1 % increments
Humidity control operating time without refilling 55 hours max. at 85% RH and 36°C (97° F) in Air Mode
Humidity control reservoir capacity 3000 ml
Humidity display accuracy + 10% RH (between 10% and 90% at 20° c (68° F) to 40° c (104°F))
OXYGEN SERVO CONTROL
Oxygen control range 21 % to 75%/95% (hood/head hood)
Oxygen control accuracy of full scale ± 3%
Oxygen display accuracy (100% calibration) ± 3%
Oxygen display accuracy (21 % calibration) ± 3%
Oxygen display resolution 1%
WEIGHING SCALE
Weight range 0 to 10 kg (22 lbs)
Weight display resolution 1 gr or 1 oz
Weight accuracy up to 5 kg + 2 gr, over 5 kg + 5 gr
DEVICE CLASSIFICATION
Protection class Class 1, Type BF, continuous operation
Ingress of liquids IP20
TREND PARAMETERS
3/24/170-hour trend Air temperature / Skin temperature / Peripherial temperature / Relative humidity / Oxygen concentration / SpO2 (Pulse Oximeter) / Heater power / Weight

 

 

 

Reviews

There are no reviews yet.

Be the first to review “Neonatal Transport Incubator BLF-2001G”

Your email address will not be published. Required fields are marked *

Quick Comparison

Neonatal Transport Incubator BLF-2001G removeFirst Aid Box Aluminium Large removeScrub Suit removeSyringe Bulb removeDirty Linen Trolley removeMedical Safety Google remove
NameNeonatal Transport Incubator BLF-2001G removeFirst Aid Box Aluminium Large removeScrub Suit removeSyringe Bulb removeDirty Linen Trolley removeMedical Safety Google remove
Image
SKUSF1033560130129-1SF1033560084-251SF1033560084-202SF1033560084-205SF1033560084-226SF1033560084-196
Rating
Price

$0.00

$69.50

$11.00

$1.99

$76.00

$1.99

Stock
Availability
Add to cart

DescriptionShipped From Abroad
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock First Aid Box Aluminium Large contains variety of medical item for emergency rescue, it contains items from simple digital or disposable thermometers to hard to find first aid items such as medical scissors, and many other items that could help save a situation before being taken to the hospital for proper treatment.
Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock
  • V-neckline
  • Short raglan sleeves
  • Two pockets: one on the Top left and one on the right bottom.
  • Double stitch detail for durability
  • Side vents at hem
  • Customised polycotton fabric 
Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock Ear / Ulcer Bulb Syringes are ideal for irrigating smaller wounds and alleviating congestion. The syringes are available in several sizes to meet clinical requirements.
Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock
No of Wheel 4
Usage Hospital
Cloth Material Synthetic
Pole Material Aluminium / SS
Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock
Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Content
Neonatal Transport Incubator BLF-2001G
  https://youtu.be/pg5CGC0Ckj4  
Features
  • Humidity servo (0-95%)
  • 3 litres distilled and residual water reservoirs
  • Air temperature servo control w/ override (25-39 oC)
  • Glass-like transparent single wall hood, x-ray compatible
  • Hood with front access door
  • Hood with 4 noiseless, easy to open hand ports / windows
  • Hood with 2 iris ports / windows
  • Hood with 6 tube ports
  • Cradle with anti-decubitus mattress, x-ray compatible
  • Space for x-ray cassette under the cradle
  • Mechanical one step cradle tilting, up to 12 degrees
  • Heavy duty stand with 4 castors (2 lockable)
  • Instrument shelf on the stand
  • Protector and instrument holder rails on each side
  • HEPA 13 air filter
  • State-of-the-art microprocessor controller
  • 5” bi-colour LCD display
  • Water resistant, foil-covered keypad with lock
  • Test button / Self test / Silence / Reset button
  • Display of heating intensity, date, set and actual values
  • 3/24/170 hours trends
  • Visual and audible alarms and backup sensors
  • Continuous self-test function during operation
  • Test button / Self test / Silence / Reset button
  • RS-232 connector
  • 230V/50Hz+/-10% (230V/60Hz or 110V/50-60Hz on request)
Properties
  • Exceptional Safety
The functions and operation of BLF-2001 incubators meet the requirements of IEC-601-2-19 product standard and those of the 93/42/EEC Directive. The materials used comply with the hygienic and toxicological requirements and are monitored continuously. The development, production and quality assurance of the incubators are performed in accordance with the ISO 13485 and ISO 9001 standards. Alarm and warning details: High temperature / Ventilation fault / Temperature sensor fault (air sensor 1, air sensor 2, air sensor 3, skin sensor, second skin sensor, rectal sensor) / Humidifying / Technical fault / Mains fault / Low limit off / Low limit air / High limit air / - Acoustic and yellow or red colored messages/signs on the LCD in case of alarm or warming
  • Easy Access
The hood has six fully transparent windows (with iris opening upon request) and a large (upon request two) door(s). An X-ray cassette can be inserted under the cradle or on a cassette holder tray (optional). The cradle with the baby can be placed into an inclined position (even electrically upon request; optional), and the baby can be removed from the incubator safely and quickly together with the cradle.
  • Air Curtain
ln the hood the air streams along the longitudinal axis of the baby's body. When the door is opened, an air curtain develops in the door. The hood of the unit may be single, double or triple walled (optional).
  • Easy Operation
The incubators are equipped with foil-covered keyboards and graphic LCD displays. Settings are easy to understand having the lowest possible number of controls. Set and real-time measured values are constantly shown on the LCD display.
  • Silent Operation
The noise level in the hood is below 45 dBA (40 dBA as option). The opening and closing of windows is absolutely noiseless. The air flow rate is well below the value allowed by the relevant standards.
  • Variable oxygen supply
Oxygen supply in the hood is controlled by a rotameter between 21-40% (optional). An electronic oxygen servo unit provides higher oxygen concentration for more intensity between 21-75% (optional). The incubators may be ordered also with head hood and with warmed humidified oxygen servo control (21-95%) (optional).
  • Comfort
ln the incubator, the baby's weight is measured with high accuracy by an electronic scale located under the cradle, the measured value is shown on the graphic display, while data are stored (optional). The height of the lying surface can be made electronically adjustable upon request (optional).
  • Micro-computer control

BLF-2001 incubators are micro-computer controlled. When switched on, a hardware and software self-test is launched. Possible errors are indicated on the graphic display. The trends and values measured every 3 or 24 or 170 hours can be retrieved from the memory of the incubator. The incubator may be connected to an external computer (by means of a software programme to be purchased separately), enabling monitoring and remote control, as well as the saving and printing of measured values and trends (optional).

The display of the BLF-2001 incubator is easy to read even from distance, indicating the following data, depending on the configuration:
  • temperature of air in the hood
  • humidity of air in the hood
  • baby's skin temperature (optional)
  • oxygen concentration (optional)
  • weight (optional)
  • second body temperature (optional)
The temperature control ranges of the incubator are as follows:
  • in normal mode of operation in the case of 'air control' 27-37°C in the case of skin control 34-36°C.
  • ln 'override' operation in the case of 'air control' 37-39°C, in the case of 'skin control' 36-38°C.
 
Technical data
PHYSICAL ATTRIBUTES (STANDARD VERSION)
Height / Packing 13 2/152 cm (52/60 in)
Width / Packing 85/95 cm (33/37 in)
Depth / Packing 60/70 cm (24/28 in)
Weight / Packing 70 kg (154 lbs)
Mains voltage 2 20/230V ± 10% (default), 110/120V ± 10% ( upon request)
Nominal frequency 50/60Hz
Nominal power consumption 420VA
Operating ambient temperature range +20°C - +30°C (68°F - 86°F)
Storage/transport ambient temperature range -40°C - 70°C (-40°F - 158°F)
Operating (Storage) ambient RH range 30% - 90% (10% - 100%)
Operating (Storage) air pressure range 700 hPa - 1060 hPa (500 hPa - 1060 hPa)
HOOD SPECIFICATIONS
Access door opening height 30 cm(12 in)
Mattress tray size 70 x 40 cm (27,6 x 15,75 in) / Optional 70 x 46 cm (27,6 x 18,11 in)
Mattress to hood height 36 cm (14 in) default, up to 45 cm (18 in) as option
Mattress size 70 x 40 cm (27,6 x 15,75 in) / Optional 70 x 46 cm (27,6 x 18,11 in)
TEMPERATURE CONTROL MODES
Temperature control modes Air (standard) / Skin (option)
Temperature display range (Air/Skin mode) 0.0°C (32.0° F) to 50.0°C ( 12 2.0°F)
Air mode control temperature range 0.0°C (68.0°F) to 37.0°C (98.6°F), in 0.1°C increments
Air mode control override temperature range 37.0°C (98.6° F) to 39.0°C (102.2° F), in 0.1°C increments
Skin mode control temperature range 34.0° ( (93.2° F) to 36.0° ( (96.8°F),
Skin mode control override temperature range 36.0° (96.8° F) to 38.0° (100.4° F), in 0.1°C increments
Peripherial skin / Rectal temperature monitoring Yes
PERFORMANCE
Air flow velocity across mattress under 10 cm/sec
Temperature rise time at 22 °C (72° F) ambient under 20 min
Temperature variability under 0.5°C (0.9°F)
Temperature uniformity on the surface of the mattress under 0.8°C (1.4°F)
Correlation of the indicated air temperature with the actual incubator temperature under 0.8°C (1.4°F)
Operating noise level in hood under 45 dBA (40 dBA as option)
Carbon Dioxide (CO) level (per EN60601-2-19) under 0,2%
Micro air intake filter HEPA 13 - 99 ,95%
Particle size removal 0.3 micron
HUMIDITY SERVO CONTROL
Humidity control range 30% to 95% in 1 % increments
Humidity control operating time without refilling 55 hours max. at 85% RH and 36°C (97° F) in Air Mode
Humidity control reservoir capacity 3000 ml
Humidity display accuracy + 10% RH (between 10% and 90% at 20° c (68° F) to 40° c (104°F))
OXYGEN SERVO CONTROL
Oxygen control range 21 % to 75%/95% (hood/head hood)
Oxygen control accuracy of full scale ± 3%
Oxygen display accuracy (100% calibration) ± 3%
Oxygen display accuracy (21 % calibration) ± 3%
Oxygen display resolution 1%
WEIGHING SCALE
Weight range 0 to 10 kg (22 lbs)
Weight display resolution 1 gr or 1 oz
Weight accuracy up to 5 kg + 2 gr, over 5 kg + 5 gr
DEVICE CLASSIFICATION
Protection class Class 1, Type BF, continuous operation
Ingress of liquids IP20
TREND PARAMETERS
3/24/170-hour trend Air temperature / Skin temperature / Peripherial temperature / Relative humidity / Oxygen concentration / SpO2 (Pulse Oximeter) / Heater power / Weight
     
First Aid Box Aluminium Large contains variety of medical item for emergency rescue, it can contain items from simple digital or disposable thermometers to hard to find first aid items such as medical scissors, and many other items that could help save a situation before being taken to the hospital for proper treatment.
  • V-neckline
  • Short raglan sleeves
  • Two pockets: one on the Top left and one on the right bottom.
  • Double stitch detail for durability
  • Side vents at hem
  • Customised polycotton fabric 
 
  • Category: Doctor General Wear, Nurse Wear, Attendant Wear, Hospital Staff Wear, Ot Room Wear
  •  Color: Blue, Green, Magenta , Light Teal, Light Green, Sky blue, Ocean blue, Coral Pink
  •  Size: Small, Medium, Large, XL, XXL
  •  Gender: Male
  •  Material: Polycotton
  •  Sleeve Type: Half
  •  Pattern: Closed
  •  Disposable: No
  •  Neck Type: "V" Neck
  • Wash Care: Do Not Bleach, Machine Wash, Hand Wash
 
Ear / Ulcer Bulb Syringes are ideal for irrigating smaller wounds and alleviating congestion. The syringes are available in several sizes to meet clinical requirements.
  • Disposable syringe for aspiration and irrigation
  • Ideal for suctioning a newborn's airway
  • Sterile
  • Bulb Aspirator Syringe. - Supplied in sealed pack - Sterile.
  • Latex Free Bulb aspirator Syringe - Essential part of any Whelping kit.
  • Quickly and hygienically removes fluids from mouth and throat of puppies & Kittens.
  • Nasal aspirator to clear nose in babies.
  • Can be used to wash ulcers.
No of Wheel 4
Usage Hospital
Cloth Material Synthetic
Pole Material Aluminium / SS
WeightN/AN/AN/AN/AN/AN/A
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • Rating
  • Price
  • Description
Click outside to hide the comparison bar
Compare