/

Neonatal Transport Incubator BLF-2001G

Ask for Price$0.00

Shipped From Abroad

Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
SF1033560130129-1
Brands:: MEDICOR

Description

Neonatal Transport Incubator BLF-2001G

 

 

Features
  • Humidity servo (0-95%)
  • 3 litres distilled and residual water reservoirs
  • Air temperature servo control w/ override (25-39 oC)
  • Glass-like transparent single wall hood, x-ray compatible
  • Hood with front access door
  • Hood with 4 noiseless, easy to open hand ports / windows
  • Hood with 2 iris ports / windows
  • Hood with 6 tube ports
  • Cradle with anti-decubitus mattress, x-ray compatible
  • Space for x-ray cassette under the cradle
  • Mechanical one step cradle tilting, up to 12 degrees
  • Heavy duty stand with 4 castors (2 lockable)
  • Instrument shelf on the stand
  • Protector and instrument holder rails on each side
  • HEPA 13 air filter
  • State-of-the-art microprocessor controller
  • 5” bi-colour LCD display
  • Water resistant, foil-covered keypad with lock
  • Test button / Self test / Silence / Reset button
  • Display of heating intensity, date, set and actual values
  • 3/24/170 hours trends
  • Visual and audible alarms and backup sensors
  • Continuous self-test function during operation
  • Test button / Self test / Silence / Reset button
  • RS-232 connector
  • 230V/50Hz+/-10% (230V/60Hz or 110V/50-60Hz on request)
Properties
  • Exceptional Safety

The functions and operation of BLF-2001 incubators meet the requirements of IEC-601-2-19 product standard and those of the 93/42/EEC Directive. The materials used comply with the hygienic and toxicological requirements and are monitored continuously. The development, production and quality assurance of the incubators are performed in accordance with the ISO 13485 and ISO 9001 standards.
Alarm and warning details: High temperature / Ventilation fault / Temperature sensor fault (air sensor 1, air sensor 2, air sensor 3, skin sensor, second skin sensor, rectal sensor) / Humidifying / Technical fault / Mains fault / Low limit off / Low limit air / High limit air / – Acoustic and yellow or red colored messages/signs on the LCD in case of alarm or warming

  • Easy Access

The hood has six fully transparent windows (with iris opening upon request) and a large (upon request two) door(s). An X-ray cassette can be inserted under the cradle or on a cassette holder tray (optional). The cradle with the baby can be placed into an inclined position (even electrically upon request; optional), and the baby can be removed from the incubator safely and quickly together with the cradle.

  • Air Curtain

ln the hood the air streams along the longitudinal axis of the baby’s body. When the door is opened, an air curtain develops in the door. The hood of the unit may be single, double or triple walled (optional).

  • Easy Operation

The incubators are equipped with foil-covered keyboards and graphic LCD displays. Settings are easy to understand having the lowest possible number of controls. Set and real-time measured values are constantly shown on the LCD display.

  • Silent Operation

The noise level in the hood is below 45 dBA (40 dBA as option). The opening and closing of windows is absolutely noiseless. The air flow rate is well below the value allowed by the relevant standards.

  • Variable oxygen supply

Oxygen supply in the hood is controlled by a rotameter between 21-40% (optional). An electronic oxygen servo unit provides higher oxygen concentration for more intensity between 21-75% (optional). The incubators may be ordered also with head hood and with warmed humidified oxygen servo control (21-95%) (optional).

  • Comfort

ln the incubator, the baby’s weight is measured with high accuracy by an electronic scale located under the cradle, the measured value is shown on the graphic display, while data are stored (optional). The height of the lying surface can be made electronically adjustable upon request (optional).

  • Micro-computer control

BLF-2001 incubators are micro-computer controlled. When switched on, a hardware and software self-test is launched. Possible errors are indicated on the graphic display. The trends and values measured every 3 or 24 or 170 hours can be retrieved from the memory of the incubator. The incubator may be connected to an external computer (by means of a software programme to be purchased separately), enabling monitoring and remote control, as well as the saving and printing of measured values and trends (optional).

The display of the BLF-2001 incubator is easy to read even from distance, indicating the following data, depending on the configuration:

  • temperature of air in the hood
  • humidity of air in the hood
  • baby’s skin temperature (optional)
  • oxygen concentration (optional)
  • weight (optional)
  • second body temperature (optional)

The temperature control ranges of the incubator are as follows:

  • in normal mode of operation in the case of ‘air control’ 27-37°C in the case of skin control 34-36°C.
  • ln ‘override’ operation in the case of ‘air control’ 37-39°C, in the case of ‘skin control’ 36-38°C.

 

Technical data
PHYSICAL ATTRIBUTES (STANDARD VERSION)
Height / Packing 13 2/152 cm (52/60 in)
Width / Packing 85/95 cm (33/37 in)
Depth / Packing 60/70 cm (24/28 in)
Weight / Packing 70 kg (154 lbs)
Mains voltage 2 20/230V ± 10% (default), 110/120V ± 10% ( upon request)
Nominal frequency 50/60Hz
Nominal power consumption 420VA
Operating ambient temperature range +20°C – +30°C (68°F – 86°F)
Storage/transport ambient temperature range -40°C – 70°C (-40°F – 158°F)
Operating (Storage) ambient RH range 30% – 90% (10% – 100%)
Operating (Storage) air pressure range 700 hPa – 1060 hPa (500 hPa – 1060 hPa)
HOOD SPECIFICATIONS
Access door opening height 30 cm(12 in)
Mattress tray size 70 x 40 cm (27,6 x 15,75 in) / Optional 70 x 46 cm (27,6 x 18,11 in)
Mattress to hood height 36 cm (14 in) default, up to 45 cm (18 in) as option
Mattress size 70 x 40 cm (27,6 x 15,75 in) / Optional 70 x 46 cm (27,6 x 18,11 in)
TEMPERATURE CONTROL MODES
Temperature control modes Air (standard) / Skin (option)
Temperature display range (Air/Skin mode) 0.0°C (32.0° F) to 50.0°C ( 12 2.0°F)
Air mode control temperature range 0.0°C (68.0°F) to 37.0°C (98.6°F), in 0.1°C increments
Air mode control override temperature range 37.0°C (98.6° F) to 39.0°C (102.2° F), in 0.1°C increments
Skin mode control temperature range 34.0° ( (93.2° F) to 36.0° ( (96.8°F),
Skin mode control override temperature range 36.0° (96.8° F) to 38.0° (100.4° F), in 0.1°C increments
Peripherial skin / Rectal temperature monitoring Yes
PERFORMANCE
Air flow velocity across mattress under 10 cm/sec
Temperature rise time at 22 °C (72° F) ambient under 20 min
Temperature variability under 0.5°C (0.9°F)
Temperature uniformity on the surface of the mattress under 0.8°C (1.4°F)
Correlation of the indicated air temperature with the actual incubator temperature under 0.8°C (1.4°F)
Operating noise level in hood under 45 dBA (40 dBA as option)
Carbon Dioxide (CO) level (per EN60601-2-19) under 0,2%
Micro air intake filter HEPA 13 – 99 ,95%
Particle size removal 0.3 micron
HUMIDITY SERVO CONTROL
Humidity control range 30% to 95% in 1 % increments
Humidity control operating time without refilling 55 hours max. at 85% RH and 36°C (97° F) in Air Mode
Humidity control reservoir capacity 3000 ml
Humidity display accuracy + 10% RH (between 10% and 90% at 20° c (68° F) to 40° c (104°F))
OXYGEN SERVO CONTROL
Oxygen control range 21 % to 75%/95% (hood/head hood)
Oxygen control accuracy of full scale ± 3%
Oxygen display accuracy (100% calibration) ± 3%
Oxygen display accuracy (21 % calibration) ± 3%
Oxygen display resolution 1%
WEIGHING SCALE
Weight range 0 to 10 kg (22 lbs)
Weight display resolution 1 gr or 1 oz
Weight accuracy up to 5 kg + 2 gr, over 5 kg + 5 gr
DEVICE CLASSIFICATION
Protection class Class 1, Type BF, continuous operation
Ingress of liquids IP20
TREND PARAMETERS
3/24/170-hour trend Air temperature / Skin temperature / Peripherial temperature / Relative humidity / Oxygen concentration / SpO2 (Pulse Oximeter) / Heater power / Weight

 

 

 

Reviews

There are no reviews yet.

Be the first to review “Neonatal Transport Incubator BLF-2001G”

Your email address will not be published. Required fields are marked *

Quick Comparison

Neonatal Transport Incubator BLF-2001G removeSiare Morpheus M Anaesthetic Machine removeScrub Suit removeSiare Morpheus LT Anaesthetic Machine removeHospital Trolley removeMedical Safety Google remove
NameNeonatal Transport Incubator BLF-2001G removeSiare Morpheus M Anaesthetic Machine removeScrub Suit removeSiare Morpheus LT Anaesthetic Machine removeHospital Trolley removeMedical Safety Google remove
Image
SKUSF1033560130129-1SF1033560101-2SF1033560084-202SF1033560101- 3SF1033560084-237SF1033560084-196
Rating
Price

Ask for Price$0.00

Ask for Price$0.00

$11.00

Ask for Price$0.00

$48.00

$1.99

Stock
Availability
Add to cart

DescriptionShipped From Abroad
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped from Abroad The MORPHEUS M is an anaesthesia machine and it can be used on adult, children and newborn patients. The MORPHEUS M is suitable for administration of Oxygen – Air – Nitrous Oxide – Halothane – Enflurane – Isoflurane – Sevoflurane – Desflurane mixtures. Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.In stock
  • V-neckline
  • Short raglan sleeves
  • Two pockets: one on the Top left and one on the right bottom.
  • Double stitch detail for durability
  • Side vents at hem
  • Customised polycotton fabric 
Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped from Abroad he Morpheus LT is an anesthetic machine suitable for treatment of adults, children and new-borns. lt is provided with a mechanical 3-gas flowmeters group and a group tor rapid connection of two vaporizers in line and it is supplied with an advanced manual ventilation system, APL system, or AUX system with traditional To-and-Fro valve switched on and off automatically by ventilator. The unit frame is made tor 30% of light alloy and for 70% of fullyrecyclable plastic materiai. Thanks to the materiai used, the Morpheus has a total weight of less than 80 kgs. Delivery & Availability: Typically 15 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.In stock Dimension (mm): L550 x W420 x H880 mm Color: Grey Material: Stainless steel No of wheel: 4
Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock
Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Content
Neonatal Transport Incubator BLF-2001G
  https://youtu.be/pg5CGC0Ckj4  
Features
  • Humidity servo (0-95%)
  • 3 litres distilled and residual water reservoirs
  • Air temperature servo control w/ override (25-39 oC)
  • Glass-like transparent single wall hood, x-ray compatible
  • Hood with front access door
  • Hood with 4 noiseless, easy to open hand ports / windows
  • Hood with 2 iris ports / windows
  • Hood with 6 tube ports
  • Cradle with anti-decubitus mattress, x-ray compatible
  • Space for x-ray cassette under the cradle
  • Mechanical one step cradle tilting, up to 12 degrees
  • Heavy duty stand with 4 castors (2 lockable)
  • Instrument shelf on the stand
  • Protector and instrument holder rails on each side
  • HEPA 13 air filter
  • State-of-the-art microprocessor controller
  • 5” bi-colour LCD display
  • Water resistant, foil-covered keypad with lock
  • Test button / Self test / Silence / Reset button
  • Display of heating intensity, date, set and actual values
  • 3/24/170 hours trends
  • Visual and audible alarms and backup sensors
  • Continuous self-test function during operation
  • Test button / Self test / Silence / Reset button
  • RS-232 connector
  • 230V/50Hz+/-10% (230V/60Hz or 110V/50-60Hz on request)
Properties
  • Exceptional Safety
The functions and operation of BLF-2001 incubators meet the requirements of IEC-601-2-19 product standard and those of the 93/42/EEC Directive. The materials used comply with the hygienic and toxicological requirements and are monitored continuously. The development, production and quality assurance of the incubators are performed in accordance with the ISO 13485 and ISO 9001 standards. Alarm and warning details: High temperature / Ventilation fault / Temperature sensor fault (air sensor 1, air sensor 2, air sensor 3, skin sensor, second skin sensor, rectal sensor) / Humidifying / Technical fault / Mains fault / Low limit off / Low limit air / High limit air / - Acoustic and yellow or red colored messages/signs on the LCD in case of alarm or warming
  • Easy Access
The hood has six fully transparent windows (with iris opening upon request) and a large (upon request two) door(s). An X-ray cassette can be inserted under the cradle or on a cassette holder tray (optional). The cradle with the baby can be placed into an inclined position (even electrically upon request; optional), and the baby can be removed from the incubator safely and quickly together with the cradle.
  • Air Curtain
ln the hood the air streams along the longitudinal axis of the baby's body. When the door is opened, an air curtain develops in the door. The hood of the unit may be single, double or triple walled (optional).
  • Easy Operation
The incubators are equipped with foil-covered keyboards and graphic LCD displays. Settings are easy to understand having the lowest possible number of controls. Set and real-time measured values are constantly shown on the LCD display.
  • Silent Operation
The noise level in the hood is below 45 dBA (40 dBA as option). The opening and closing of windows is absolutely noiseless. The air flow rate is well below the value allowed by the relevant standards.
  • Variable oxygen supply
Oxygen supply in the hood is controlled by a rotameter between 21-40% (optional). An electronic oxygen servo unit provides higher oxygen concentration for more intensity between 21-75% (optional). The incubators may be ordered also with head hood and with warmed humidified oxygen servo control (21-95%) (optional).
  • Comfort
ln the incubator, the baby's weight is measured with high accuracy by an electronic scale located under the cradle, the measured value is shown on the graphic display, while data are stored (optional). The height of the lying surface can be made electronically adjustable upon request (optional).
  • Micro-computer control

BLF-2001 incubators are micro-computer controlled. When switched on, a hardware and software self-test is launched. Possible errors are indicated on the graphic display. The trends and values measured every 3 or 24 or 170 hours can be retrieved from the memory of the incubator. The incubator may be connected to an external computer (by means of a software programme to be purchased separately), enabling monitoring and remote control, as well as the saving and printing of measured values and trends (optional).

The display of the BLF-2001 incubator is easy to read even from distance, indicating the following data, depending on the configuration:
  • temperature of air in the hood
  • humidity of air in the hood
  • baby's skin temperature (optional)
  • oxygen concentration (optional)
  • weight (optional)
  • second body temperature (optional)
The temperature control ranges of the incubator are as follows:
  • in normal mode of operation in the case of 'air control' 27-37°C in the case of skin control 34-36°C.
  • ln 'override' operation in the case of 'air control' 37-39°C, in the case of 'skin control' 36-38°C.
 
Technical data
PHYSICAL ATTRIBUTES (STANDARD VERSION)
Height / Packing 13 2/152 cm (52/60 in)
Width / Packing 85/95 cm (33/37 in)
Depth / Packing 60/70 cm (24/28 in)
Weight / Packing 70 kg (154 lbs)
Mains voltage 2 20/230V ± 10% (default), 110/120V ± 10% ( upon request)
Nominal frequency 50/60Hz
Nominal power consumption 420VA
Operating ambient temperature range +20°C - +30°C (68°F - 86°F)
Storage/transport ambient temperature range -40°C - 70°C (-40°F - 158°F)
Operating (Storage) ambient RH range 30% - 90% (10% - 100%)
Operating (Storage) air pressure range 700 hPa - 1060 hPa (500 hPa - 1060 hPa)
HOOD SPECIFICATIONS
Access door opening height 30 cm(12 in)
Mattress tray size 70 x 40 cm (27,6 x 15,75 in) / Optional 70 x 46 cm (27,6 x 18,11 in)
Mattress to hood height 36 cm (14 in) default, up to 45 cm (18 in) as option
Mattress size 70 x 40 cm (27,6 x 15,75 in) / Optional 70 x 46 cm (27,6 x 18,11 in)
TEMPERATURE CONTROL MODES
Temperature control modes Air (standard) / Skin (option)
Temperature display range (Air/Skin mode) 0.0°C (32.0° F) to 50.0°C ( 12 2.0°F)
Air mode control temperature range 0.0°C (68.0°F) to 37.0°C (98.6°F), in 0.1°C increments
Air mode control override temperature range 37.0°C (98.6° F) to 39.0°C (102.2° F), in 0.1°C increments
Skin mode control temperature range 34.0° ( (93.2° F) to 36.0° ( (96.8°F),
Skin mode control override temperature range 36.0° (96.8° F) to 38.0° (100.4° F), in 0.1°C increments
Peripherial skin / Rectal temperature monitoring Yes
PERFORMANCE
Air flow velocity across mattress under 10 cm/sec
Temperature rise time at 22 °C (72° F) ambient under 20 min
Temperature variability under 0.5°C (0.9°F)
Temperature uniformity on the surface of the mattress under 0.8°C (1.4°F)
Correlation of the indicated air temperature with the actual incubator temperature under 0.8°C (1.4°F)
Operating noise level in hood under 45 dBA (40 dBA as option)
Carbon Dioxide (CO) level (per EN60601-2-19) under 0,2%
Micro air intake filter HEPA 13 - 99 ,95%
Particle size removal 0.3 micron
HUMIDITY SERVO CONTROL
Humidity control range 30% to 95% in 1 % increments
Humidity control operating time without refilling 55 hours max. at 85% RH and 36°C (97° F) in Air Mode
Humidity control reservoir capacity 3000 ml
Humidity display accuracy + 10% RH (between 10% and 90% at 20° c (68° F) to 40° c (104°F))
OXYGEN SERVO CONTROL
Oxygen control range 21 % to 75%/95% (hood/head hood)
Oxygen control accuracy of full scale ± 3%
Oxygen display accuracy (100% calibration) ± 3%
Oxygen display accuracy (21 % calibration) ± 3%
Oxygen display resolution 1%
WEIGHING SCALE
Weight range 0 to 10 kg (22 lbs)
Weight display resolution 1 gr or 1 oz
Weight accuracy up to 5 kg + 2 gr, over 5 kg + 5 gr
DEVICE CLASSIFICATION
Protection class Class 1, Type BF, continuous operation
Ingress of liquids IP20
TREND PARAMETERS
3/24/170-hour trend Air temperature / Skin temperature / Peripherial temperature / Relative humidity / Oxygen concentration / SpO2 (Pulse Oximeter) / Heater power / Weight
     
The MORPHEUS M is an anaesthesia machine and it can be used on adult, children and newborn patients. The MORPHEUS M is suitable for administration of Oxygen – Air – Nitrous Oxide – Halothane – Enflurane – Isoflurane – Sevoflurane – Desflurane mixtures. Features:
  • Mechanic gas mixing system
  • Electronic lung ventilator with 12” TFT colour display
  • Valves group: open, semi-closed, closed, heated, with soda lime absorber (1,5 Kg)
  • SIARETEX rapid connection device, Selectatec compatible for 2 vaporizers
  • Gas supply group
  • Ventilation modalities: APCV-PCV; APCV-TV; PSV; APNEA BACK-UP; VC-VAC; VC-VAC BABY; SIMV+PS (volumetric); SPONT; MANUAL.
  • Measured parameters: PAW; PEEP; Vte; ExpMV; Rate; I:E; FiO2, Pmax; Pmean; Pause; Vti; FLOWi; FLOWe; Tinsp; Tesp; Tpause; Cs; Ri
  • Displayed ventilation curves: Paw, Flow, Volume, Loop (Volume/Paw ; Volume/Flow)
  • Adjustable parameters: – O2 built-in Mixer device from 21% to 99% – I:E Adjustable Ratio: 1:1-1:2-1:3-1:4-2:1-3:1 – Inspiratory Flow – PEEP – Breathing Rate – Minute Volume; – Tidal Volume – Inspiratory Pressure Limit – Inspiratory Pause – Inspiratory Time – Trigger
  • Mechanic flowmeter module: 3-flow mechanical flow meter (O2 – N2O – AIR) with 5 flow meters for low flows. Equipped with safety systems (MIX-LIFE, CUT-OFF, flow meter protection valve).
  • Breathing system: The breathing system of Morpheus guarantees to the user an absolute flexibility and easy handling thanks to the noble construction materials employed. The valves group can be drawn-up and it’s totally autoclavable at 121°C and all its parts are manually dismountable, with no need of special tools.The breathing system is made of; Calibrated APL valve, Fresh gas collecting bag, O2 cell for reading of FiO2, Removable 1 kg soda lime canister, Manually inspectionable bellows jar, Safety valve for ambience air suction in case of fresh gas failure, Flow transducer inside the group located on the expiratory line.
Optional accessories 11054 AIRPAK 54 stand-alone medical air compressor 100150/IDF Isoflurane Vaporizer 100148/IDF Fluo-Halotane Vaporizer 100145/IDF Sevoflurane Vaporizer 100151/IDF Desflurane Vaporizer A57.049-800601 gas analysis module (5 AA – CO2 – N2O – O2 – MAC) ric.auto  
Click Here To Download Catalogue
                              )
  • V-neckline
  • Short raglan sleeves
  • Two pockets: one on the Top left and one on the right bottom.
  • Double stitch detail for durability
  • Side vents at hem
  • Customised polycotton fabric 
 
  • Category: Doctor General Wear, Nurse Wear, Attendant Wear, Hospital Staff Wear, Ot Room Wear
  •  Color: Blue, Green, Magenta , Light Teal, Light Green, Sky blue, Ocean blue, Coral Pink
  •  Size: Small, Medium, Large, XL, XXL
  •  Gender: Male
  •  Material: Polycotton
  •  Sleeve Type: Half
  •  Pattern: Closed
  •  Disposable: No
  •  Neck Type: "V" Neck
  • Wash Care: Do Not Bleach, Machine Wash, Hand Wash
 
The Morpheus LT is an anesthetic machine suitable for treatment of adults, children and new-borns. lt is provided with a mechanical 3-gas flowmeters group and a group tor rapid connection of two vaporizers in line and it is supplied with an advanced manual ventilation system, APL system, or AUX system with traditional To-and-Fro valve switched on and off automatically by ventilator. The unit frame is made tor 30% of light alloy and for 70% of fullyrecyclable plastic materiai. Thanks to the materiai used, the Morpheus has a total weight of less than 80 kgs. LUNG VENTILATOR The ventilator works by a microprocessor electronic control system with a simple and intuitive interface, which allows the anesthetist to operate in a clear and safe way. The system is provided with 3 dedicated software to have automatically the default settings for adult and paediatric patients and new-borns. lt is provided with the automatic compensation of dead space, the leakages calculation and the automatic calibration of Fi02. Operative Modes: MAN VC-VC PCV-APCV APCV P -SIMV V- SIMV Measured parameters: PAW RATE VM - VTE T INSP Fi02 MANUAL VENTILATION SYSTEM The Morpheus is equipped with an advanced manual ventilation system that can be switched on and off automatically by the ventilator; the operator can select the APL system or the AUX system with traditional T-and-Fro valve and 02 by pass safety system. BREATHING SYSTEM The patient group of Morpheus LT is compact, lightweight for manual removal and fully autoclavable. The patient circuit group is supplied with an automatic heating system avoiding humidity with possibility to use reusable and rechargeable CO, absorbers (TOP SPECIAL) of 1 kg. Absorber is with quick-release enabling replacement also during anaesthesia. The group is supplied with an exposed bellow that can be manually inspected. The MorpheusLT is equipped with 3 wide and large drawers and a large work-shelf to facilitate operating rooms procedures.
Click Here To Download Catalogue
Dimension (mm) L550 x W420 x H880 mm
Color Grey
Material Stainless steel
No of wheel 4
WeightN/AN/AN/AN/AN/AN/A
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • Rating
  • Price
  • Description
Click outside to hide the comparison bar
Compare