Neuro-IOM-16/S

$0.00

Shipped From Abroad

Neuro-IOM-16/S is a compact intraoperative monitoring (IOM) system with 16 channels for real-time EMG, EEG, and Evoked Potentials (EP). It is designed to monitor neurological functions during surgeries, allowing surgeons and neurophysiologists to detect potential risks and prevent nerve damage. With high-resolution technology and an intuitive interface, the system provides reliable, continuous feedback, ensuring optimal patient safety and surgical outcomes.

Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
SF1033560130187-23
Brands:: Neurosoft

Description

System with Basic Functions for Intraoperative Neurophysiological Monitoring

 

 

Neuro-IOM: your reliable startup

This configuration of Neuro-IOM system (version 2) includes all basic functions to perform intraoperative neurophysiological monitoring

Main features:
  • 16 amplifier channels with expandable outputs;
  • 2 dedicated channels for routine EMG, NCS and EP;
  • 4 electrical stimulator channels. In most cases 4 electrical stimulator channels are enough for SEP and MEP acquisition. For example, 2 channels are used for the stimulation of lower limbs during the acquisition of SEP responses, one channel is used for transcranial electrical stimulation and the other one is left as additional.
  • direct nerve stimulation channel;
  • auditory, visual and pattern stimulator channels;
  • ES detector channels.

The Neuro-IOM system performs intraoperative neurophysiological monitoring of all modalities, including MEP acquisition using the electrical stimulator with current intensity of up to 200 mA.

The Neuro-IOM system is equipped with the acquisition and stimulator pods to attach recording and stimulating electrodes with 5 m cables. It allows arranging the system at a distance from the operating table to ensure free movement for the surgical team. The set of specially-designed electrodes and the software are also included to the delivery set.

Motor, somatosensory, auditory and visual evoked potentials, EMG, direct nerve stimulation, EEG, ECoG — more than 10 modalities for intraoperative neurophysiological monitoring

The Neuro-IOM system is delivered with the preset templates ensuring the following modalities:

  • direct nerve stimulation;
  • free-run EMG;
  • somatosensory evoked potentials (SSEP);
  • motor evoked potentials (MEP);
  • auditory evoked potentials (AEP);
  • visual evoked potentials (VEP);
  • EEG;
  • ECoG;
  • direct cortical stimulation;
  • train-of-four stimulation (TOF).

Using these modalities the surgical team can control motor and sensory pathways, monitor peripheral nerve integrity, assess the brain activity and perform mapping of its functional areas, etc.

Flexible configurations to ensure any monitoring needs

The Neuro-IOM.NET software provides a set of default templates for various types of surgeries. Each template includes the settings of modalities for a particular type of surgery, test window layouts, acquisition and stimulation parameters, etc. The system has a vast number of channels and stimulators with separate adjustment. Use of preset templates simplifies and speeds up the system setup for surgery.

You can always change and save the settings of any surgery template. It is a unique option for such kind of systems. There is no IONM system in the world that is so flexible!

Applications
  • SEP acquisition
  • MEP acquisition
  • 16 amplifier channels(32 channels)
  • auditory and visual evoked potentials, EMG, direct nerve stimulation, EEG, ECoG — more than 10 monitoring modalities
  • flexible configurations to ensure any monitoring needs

Download Brochure

Reviews

There are no reviews yet.

Be the first to review “Neuro-IOM-16/S”

Your email address will not be published. Required fields are marked *

Quick Comparison

Neuro-IOM-16/S removeOxygen Generator/Plant removeBRAINSWAY Deep TMS H1 Coil removeBRAINSWAY Deep TMS H7 RCT Coil removeBRAINSWAY Deep TMS H4 Coil removeSelf-Retaining Retractor remove
NameNeuro-IOM-16/S removeOxygen Generator/Plant removeBRAINSWAY Deep TMS H1 Coil removeBRAINSWAY Deep TMS H7 RCT Coil removeBRAINSWAY Deep TMS H4 Coil removeSelf-Retaining Retractor remove
Image
SKUSF1033560130187-23SF103356013076SF1033560130162-4SF1033560130162-6SF1033560130162-7SF1033560130176-10
Rating
Price

$0.00

$0.00

$0.00

$0.00

$0.00

$0.00

Stock
Availability
Add to cart

DescriptionShipped From Abroad Neuro-IOM-16/S is a compact intraoperative monitoring (IOM) system with 16 channels for real-time EMG, EEG, and Evoked Potentials (EP). It is designed to monitor neurological functions during surgeries, allowing surgeons and neurophysiologists to detect potential risks and prevent nerve damage. With high-resolution technology and an intuitive interface, the system provides reliable, continuous feedback, ensuring optimal patient safety and surgical outcomes.
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad
PSA Medical & Industrial oxygen generator systems produce gas oxygen from compressed air from the field where they work and switch compatible to conventional oxygen gas source such as tubes or cryogenic liquid. Delivery & Availability: Typically, 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad
The H1 Coil stimulates the bilateral prefrontal cortex, with a preference for the left dorsolateral prefrontal cortex. In addition to numerous published, double-blind, randomized controlled trials validating the efficacy of Deep TMS for depression, clinical data of over 1,000 patients in real practice settings has shown compelling results. Among patients who completed 30 sessions, approximately 4 out of 5 achieved a clinical response, and approximately 2 out of 3 achieved remission from depression.
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad The H7 Coil stimulates the anterior cingulate cortex and the medial prefrontal cortex.  Treatment is designed to regulate the CSTC circuit believed to be involved in the inhibition of impulsive behavior. A sham coil is integrated above the treatment coil. To the patient and operator, the helmet appears the same, pulses sound the same, and stimulation feels the same on the scalp.
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad The H4 Coil stimulates the bilateral insula and prefrontal cortex. Nearly 1 in 3 patients who completed 18 sessions achieved 4 or more weeks of abstinence from smoking in a large scale, double-blind, multicenter randomized controlled trial. 2 out of 3 patients who quit smoking by the end of treatment remained abstinent for at least an additional three months
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Content
System with Basic Functions for Intraoperative Neurophysiological Monitoring
  https://youtu.be/XyI13InME9A?list=PLU2BvNtfeStPOl_izQJDwlLEi6eLCrDEF   Neuro-IOM: your reliable startup This configuration of Neuro-IOM system (version 2) includes all basic functions to perform intraoperative neurophysiological monitoring
Main features:
  • 16 amplifier channels with expandable outputs;
  • 2 dedicated channels for routine EMG, NCS and EP;
  • 4 electrical stimulator channels. In most cases 4 electrical stimulator channels are enough for SEP and MEP acquisition. For example, 2 channels are used for the stimulation of lower limbs during the acquisition of SEP responses, one channel is used for transcranial electrical stimulation and the other one is left as additional.
  • direct nerve stimulation channel;
  • auditory, visual and pattern stimulator channels;
  • ES detector channels.
The Neuro-IOM system performs intraoperative neurophysiological monitoring of all modalities, including MEP acquisition using the electrical stimulator with current intensity of up to 200 mA. The Neuro-IOM system is equipped with the acquisition and stimulator pods to attach recording and stimulating electrodes with 5 m cables. It allows arranging the system at a distance from the operating table to ensure free movement for the surgical team. The set of specially-designed electrodes and the software are also included to the delivery set. Motor, somatosensory, auditory and visual evoked potentials, EMG, direct nerve stimulation, EEG, ECoG — more than 10 modalities for intraoperative neurophysiological monitoring The Neuro-IOM system is delivered with the preset templates ensuring the following modalities:
  • direct nerve stimulation;
  • free-run EMG;
  • somatosensory evoked potentials (SSEP);
  • motor evoked potentials (MEP);
  • auditory evoked potentials (AEP);
  • visual evoked potentials (VEP);
  • EEG;
  • ECoG;
  • direct cortical stimulation;
  • train-of-four stimulation (TOF).
Using these modalities the surgical team can control motor and sensory pathways, monitor peripheral nerve integrity, assess the brain activity and perform mapping of its functional areas, etc. Flexible configurations to ensure any monitoring needs The Neuro-IOM.NET software provides a set of default templates for various types of surgeries. Each template includes the settings of modalities for a particular type of surgery, test window layouts, acquisition and stimulation parameters, etc. The system has a vast number of channels and stimulators with separate adjustment. Use of preset templates simplifies and speeds up the system setup for surgery. You can always change and save the settings of any surgery template. It is a unique option for such kind of systems. There is no IONM system in the world that is so flexible!
Applications
  • SEP acquisition
  • MEP acquisition
  • 16 amplifier channels(32 channels)
  • auditory and visual evoked potentials, EMG, direct nerve stimulation, EEG, ECoG — more than 10 monitoring modalities
  • flexible configurations to ensure any monitoring needs
Download Brochure
PSA Medical & Industrıal oxygen generator systems produce gas oxygen from compressed air from the field where they work and switch compatible to conventional oxygen gas source such as tubes or cryogenic liqiud.

OXYGEN PURITY - PSA oxygen generators, continuously 90-95% purity oxygen produces.

OXYGEN FLOW - LINAIR TECHNOLOGIES manufactures oxygen generators with capacities from 1 Nm3/h to 1000 Nm3/h.

OXYGEN OUTLET PRESSURE - Oxygen generators produces 4-6 bar oxygen.

ADVANTAGES OF OXYGEN GENERATORS/Plant

  • Consistently high purity guaranteed.

  • Oxygen production according to your needs 24/7.

  • Purity control of instantaneously produced oxygen.

  • Instant monitoring of parameters such as purity, pressure, flow rate on the screen.

  • No need for an extra operator since it works fully automatically.

The BrainsWay Deep TMS H1 Coil is a transcranial magnetic stimulation (TMS) device that's used to treat depression and other mental disorders: 
  • Design
    The H1 Coil is a flexible, soft copper coil that's placed inside a helmet to stimulate the brain. The coil's design allows for a wider and deeper distribution of magnetic fields than traditional TMS coils.
  • Effectiveness
    The H1 Coil is effective in treating depression and has also been explored as a treatment for other conditions:
    • Depression: The H1 Coil is FDA-cleared to treat major depressive disorder (MDD) in adults who haven't responded well to other antidepressant medications.
    • Other conditions: The H1 Coil has been explored as a treatment for negative symptoms of schizophrenia, bipolar depression, and migraine.
  • Benefits
    The H1 Coil's design allows for greater neuron activation, which can lead to more effective stimulation and fewer targeting errors.
  • Safety
    The H1 Coil is considered a safe and effective clinical tool.
Features
  • Flexible base
    The H1 coil has a flexible base that can adapt to the shape of the patient's head. 
  • Tangential coil components
    The H1 coil has tangential coil components that are close to the brain targets. 
  • Parallel coil components
    The H1 coil has parallel coil components that direct the electric pulse beams. 
  • Electrical pulses
    The H1 coil has numerous electrical pulses that converge from various directions. 
  • Return paths
    The return paths of the electrical pulses are located at a distance from the target area. 
  • Stimulates the prefrontal cortex
    The H1 coil stimulates the bilateral prefrontal cortex, with a preference for the left dorsolateral prefrontal cortex (DLPFC). 
  • Deeper and broader stimulation
    The H1 coil's patented design enables deeper and broader stimulation than traditional TMS coils.
    Click here to download Brochure
The Brainsway Deep TMS H7 RCT Coil is a flexible coil used in transcranial magnetic stimulation (TMS) to treat obsessive-compulsive disorder (OCD) and other neuropsychiatric conditions:
  • What it does
    The H7 Coil stimulates the medial prefrontal cortex and the anterior cingulate cortex of the brain. TMS uses magnetic pulses to create an electrical current in the brain's neuronal tissue. 
  • How it's used
    The H7 Coil is integrated into a cooled, cushioned helmet that allows the patient to move around during treatment. A sham coil is also included so that the patient and operator can't tell the difference between the treatment and sham coils. 
  • What it's used for
    The H7 Coil is FDA-cleared for OCD, but it's also been shown to be effective in treating other conditions, including addiction, major depressive disorder, and autism spectrum disorder. 
  • How it works
    The H7 Coil is designed to regulate the CSTC circuit, which is thought to be involved in impulsive behavior. 
  • Safety
    A 2023 paper that analyzed adverse events from five large, randomized controlled trials found that most adverse events were transient and resolved within days.
Features
  • Stimulates specific brain regions
    The H7 Coil targets the anterior cingulate cortex and the medial prefrontal cortex. 
  • Flexible windings
    The H7 Coil's flexible windings conform to the shape of the patient's head. 
  • FDA-cleared for OCD
    The H7 Coil is FDA-cleared for treating obsessive-compulsive disorder (OCD). 
  • Demonstrated efficacy
    The H7 Coil has been shown to be effective in treating OCD patients with varying degrees of severity and comorbidities. 
  • Integrated sham coil
    The helmet includes a sham coil that makes the treatment appear, sound, and feel the same to the patient and operator.

Click here to download Brochure

The BrainsWay Deep TMS H4 Coil is a non-invasive treatment that uses magnetic energy waves to stimulate brain structures associated with addiction and weight loss: 
  • Treatment
    The H4 Coil is used to treat smoking addiction and weight loss. It generates electromagnetic pulses that stimulate the bilateral insula and prefrontal cortex of the brain.
  • Benefits
    Deep TMS is a well-tolerated treatment that can be integrated into a patient's daily schedule. It's said to have no side effects and no recovery period. Patients may start to feel relief from symptoms within a few weeks.
  • Technology
    The H4 Coil is part of a helmet that contains BrainsWay's patented H-Coils, which are designed to stimulate deeper and broader areas of the brain than traditional TMS coils. The helmet also has a touchscreen interface, adjustable positioning arm, and cooling system.
  • Safety
    The H4 Coil has lower rates of headache, treatment site discomfort, and jaw pain than other coils, but higher rates of general discomfort

Click here to download Brochure

CODE SIZE FINISH
01-01-02 12.8 cm sharp
WeightN/AN/AN/AN/AN/AN/A
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • Rating
  • Price
  • Description
Click outside to hide the comparison bar
Compare