Neuro-IOM-16/S
$0.00
Shipped From Abroad
Neuro-IOM-16/S is a compact intraoperative monitoring (IOM) system with 16 channels for real-time EMG, EEG, and Evoked Potentials (EP). It is designed to monitor neurological functions during surgeries, allowing surgeons and neurophysiologists to detect potential risks and prevent nerve damage. With high-resolution technology and an intuitive interface, the system provides reliable, continuous feedback, ensuring optimal patient safety and surgical outcomes.
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Description
System with Basic Functions for Intraoperative Neurophysiological Monitoring
Neuro-IOM: your reliable startup
This configuration of Neuro-IOM system (version 2) includes all basic functions to perform intraoperative neurophysiological monitoring
Main features:
- 16 amplifier channels with expandable outputs;
- 2 dedicated channels for routine EMG, NCS and EP;
- 4 electrical stimulator channels. In most cases 4 electrical stimulator channels are enough for SEP and MEP acquisition. For example, 2 channels are used for the stimulation of lower limbs during the acquisition of SEP responses, one channel is used for transcranial electrical stimulation and the other one is left as additional.
- direct nerve stimulation channel;
- auditory, visual and pattern stimulator channels;
- ES detector channels.
The Neuro-IOM system performs intraoperative neurophysiological monitoring of all modalities, including MEP acquisition using the electrical stimulator with current intensity of up to 200 mA.
The Neuro-IOM system is equipped with the acquisition and stimulator pods to attach recording and stimulating electrodes with 5 m cables. It allows arranging the system at a distance from the operating table to ensure free movement for the surgical team. The set of specially-designed electrodes and the software are also included to the delivery set.
Motor, somatosensory, auditory and visual evoked potentials, EMG, direct nerve stimulation, EEG, ECoG — more than 10 modalities for intraoperative neurophysiological monitoring
The Neuro-IOM system is delivered with the preset templates ensuring the following modalities:
- direct nerve stimulation;
- free-run EMG;
- somatosensory evoked potentials (SSEP);
- motor evoked potentials (MEP);
- auditory evoked potentials (AEP);
- visual evoked potentials (VEP);
- EEG;
- ECoG;
- direct cortical stimulation;
- train-of-four stimulation (TOF).
Using these modalities the surgical team can control motor and sensory pathways, monitor peripheral nerve integrity, assess the brain activity and perform mapping of its functional areas, etc.
Flexible configurations to ensure any monitoring needs
The Neuro-IOM.NET software provides a set of default templates for various types of surgeries. Each template includes the settings of modalities for a particular type of surgery, test window layouts, acquisition and stimulation parameters, etc. The system has a vast number of channels and stimulators with separate adjustment. Use of preset templates simplifies and speeds up the system setup for surgery.
You can always change and save the settings of any surgery template. It is a unique option for such kind of systems. There is no IONM system in the world that is so flexible!
Applications
- SEP acquisition
- MEP acquisition
- 16 amplifier channels(32 channels)
- auditory and visual evoked potentials, EMG, direct nerve stimulation, EEG, ECoG — more than 10 monitoring modalities
- flexible configurations to ensure any monitoring needs
Quick Comparison
Settings | Neuro-IOM-16/S remove | BRAINSWAY Deep TMS H1 Coil remove | Dolphin-IQ Transcranial Doppler Probe remove | Nitrogen Generator/Plant remove | BRAINSWAY Deep TMS 104 RCT System remove | Dolphin-XF Transcranial Robotic Probe remove |
---|---|---|---|---|---|---|
Name | Neuro-IOM-16/S remove | BRAINSWAY Deep TMS H1 Coil remove | Dolphin-IQ Transcranial Doppler Probe remove | Nitrogen Generator/Plant remove | BRAINSWAY Deep TMS 104 RCT System remove | Dolphin-XF Transcranial Robotic Probe remove |
Image | ![]() | ![]() | ![]() | ![]() | ![]() | ![]() |
SKU | SF1033560130187-23 | SF1033560130162-4 | SF1033560130142-3 | SF103356013077 | SF1033560130162-3 | SF1033560130142-4 |
Rating | ||||||
Price |
|
| $6,325.00 |
|
| $6,270.00 |
Stock | ||||||
Availability | ||||||
Add to cart | ||||||
Description | Shipped From Abroad
Neuro-IOM-16/S is a compact intraoperative monitoring (IOM) system with 16 channels for real-time EMG, EEG, and Evoked Potentials (EP). It is designed to monitor neurological functions during surgeries, allowing surgeons and neurophysiologists to detect potential risks and prevent nerve damage. With high-resolution technology and an intuitive interface, the system provides reliable, continuous feedback, ensuring optimal patient safety and surgical outcomes.
Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| Shipped From Abroad
The H1 Coil stimulates the bilateral prefrontal cortex, with a preference for the left dorsolateral prefrontal cortex. In addition to numerous published, double-blind, randomized controlled trials validating the efficacy of Deep TMS for depression, clinical data of over 1,000 patients in real practice settings has shown compelling results. Among patients who completed 30 sessions, approximately 4 out of 5 achieved a clinical response, and approximately 2 out of 3 achieved remission from depression.
Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| Shipped From Abroad
All of the advantages and performance of the cutting-edge Dolphin TCD technology for measurements of cerebral blood flow velocities are implemented in the smart and compact Dolphin/IQ Transcranial Doppler module.
Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| Shipped From Abroad
PSA Industrıal nitrogen generator systems produce gas nitrogen from compressed air from the field where they work, and switch compatible to conventional nitrogen gas source such as tubes or cryogenic liqiud.
Delivery & Availability:
Typically, 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| Shipped From Abroad
BrainsWay's 104 RCT System enables blinded clinical research via a card reader that randomizes selection of sham or Deep TMS stimulation. The sham coil is integrated into the helmet with the treatment coil, producing similar sounds and sensations.
Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| Shipped From Abroad
Proudly introducing the X-Factor in TCD robotic solutions, assisting in obtaining bilateral TCD insonations in as quickly as just a few seconds!. Designed for short and long-term monitoring, for use in anesthesia, in the ICU, or in the TCD lab.
Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
|
Content | System with Basic Functions for Intraoperative Neurophysiological Monitoringhttps://youtu.be/XyI13InME9A?list=PLU2BvNtfeStPOl_izQJDwlLEi6eLCrDEF Neuro-IOM: your reliable startup This configuration of Neuro-IOM system (version 2) includes all basic functions to perform intraoperative neurophysiological monitoringMain features:
Applications
| The BrainsWay Deep TMS H1 Coil is a transcranial magnetic stimulation (TMS) device that's used to treat depression and other mental disorders:
Features
| https://youtu.be/Id0Ma1_lEo0?si=kRJ1bUMjUCBuCAqR
Features of Dolphin TCD Machine | PSA Industrıal nitrogen generator systems produce gas nitrogen from compressed air from the field where they work, and switch compatible to conventional nitrogen gas source such as tubes or cryogenic liqiud.
ADVANTAGES OF NITROGEN GENERATORS/PLANT
Wide Range Of Applications
![]() | The BrainsWay Deep TMS 104 RCT System is a non-invasive treatment for mental health conditions that uses magnetic pulses to stimulate the brain.
FeaturesThe BrainsWay Deep TMS 104 RCT System has several features, including:
Click here to download Brochure | https://youtu.be/JwSJvUVJrxo?si=6QkpitWAwvZZSwOM
DescriptionThe Dolphin/XF is a new breakthrough development in TCD robotics. It is designed to assist the user in quickly and automatically insonating and monitoring cerebral blood flow.Features |
Weight | N/A | N/A | N/A | N/A | N/A | N/A |
Dimensions | N/A | N/A | N/A | N/A | N/A | N/A |
Additional information |
Reviews
There are no reviews yet.