Neuro-IOM/Solo
$0.00
Shipped From Abroad
Neuro-IOM/Solo is a compact and portable intraoperative monitoring (IOM) system designed for real-time neurological assessment during surgeries. It provides precise EMG, EEG, and Evoked Potentials (EP) monitoring, helping surgeons and neurophysiologists detect potential neural risks and prevent nerve damage. With its user-friendly interface and high-resolution diagnostics, the Neuro-IOM/Solo ensures patient safety and enhances surgical outcomes in various clinical settings.
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Description
Surgeon driven system for Intraoperative Neuromonitoring
Features
Intraoperative monitoring without the participation of a neurophysiologist
Neuro-IOM/SOLO is an 8-channel intraoperative neuromonitoring system with a touchscreen, designed specifically for use by a surgeon. Participation of a neurophysiologist is not necessary. The electronic unit is equipped with a tablet, which can be placed next to the surgeon. At the same time, when stimulating nerve structures in the surgical field, the specialist sees instant responses on the display of a tablet clearly and without any insufficient information.
8 bipolar channels: monitoring of endocrine, maxillofacial and ENT operations
Neuro-IOM/SOLO allows monitoring via 8 bipolar channels, which is suitable for endocrine, maxillofacial and ENT surgery. The system allows monitoring in 4 modalities – evoked and spontaneous EMG, DNS, TOF.
Just turn on the device and start monitoring
Working with the device is as simple as possible – to start monitoring, you just need to turn on the device and begin the operation with a preset monitoring template. There is no need to make complicated settings.
Loud sound signal of different tones to indicate responses
The convenience of Neuro-IOM/SOLO also lies in the speakers built into the device, which allow the operating doctor not to be distracted from actions in the surgical field. Using a special stimulating electrode, the surgeon delivers a stimulus to physiological structures during surgery and can distinguish responses by ear from different tones of sound from speakers.
Wide range of consumables available
With Neuro-IOM/SOLO you can use various electrodes for stimulation of neuromuscular structures – monopolar, bipolar and concentric, as well as concentric stimulating electrodes. To remove electrophysiological signals, you can use any electrodes convenient for a specialist. Their range can be found in the IOM accessories catalogue of the Neurosoft company.
Basic solutions for IOM in a comfortable design
Neuro-IOM/SOLO is a compact device that is equipped with a convenient folding handle that allows you to carry it comfortably. The tablet for visual display of responses can be placed on the device itself in an ergonomic magnetic mount.
Additional Features
- intraoperative monitoring without a neurophysiologist’s participation
- 8 bipolar channels: monitoring of endocrine, maxillofacial and ENT operations
- just turn on the device and start monitoring
- loud sound signal of different tones to indicate responses
- wide range of consumables available
Quick Comparison
Neuro-IOM/Solo remove | Self-Retaining Retractor remove | BRAINSWAY Deep TMS 104 RCT System remove | BRAINSWAY Deep TMS H4 Coil remove | Falcon-PRO Transcranial Doppler Probe remove | VentMed DF-30V-HM BiPAP remove | |||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Name | Neuro-IOM/Solo remove | Self-Retaining Retractor remove | BRAINSWAY Deep TMS 104 RCT System remove | BRAINSWAY Deep TMS H4 Coil remove | Falcon-PRO Transcranial Doppler Probe remove | VentMed DF-30V-HM BiPAP remove | ||||||||||||||||||||||||
Image | ![]() | ![]() | ![]() | ![]() | ![]() | ![]() | ||||||||||||||||||||||||
SKU | SF1033560130187-24 | SF1033560130176-10 | SF1033560130162-3 | SF1033560130162-7 | SF1033560130142-5 | SF1033560130180-2 | ||||||||||||||||||||||||
Rating | ||||||||||||||||||||||||||||||
Price |
|
|
|
|
|
| ||||||||||||||||||||||||
Stock | ||||||||||||||||||||||||||||||
Availability | ||||||||||||||||||||||||||||||
Add to cart | ||||||||||||||||||||||||||||||
Description | Shipped From Abroad
Neuro-IOM/Solo is a compact and portable intraoperative monitoring (IOM) system designed for real-time neurological assessment during surgeries. It provides precise EMG, EEG, and Evoked Potentials (EP) monitoring, helping surgeons and neurophysiologists detect potential neural risks and prevent nerve damage. With its user-friendly interface and high-resolution diagnostics, the Neuro-IOM/Solo ensures patient safety and enhances surgical outcomes in various clinical settings.
Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| Shipped From Abroad
Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| Shipped From Abroad
BrainsWay's 104 RCT System enables blinded clinical research via a card reader that randomizes selection of sham or Deep TMS stimulation. The sham coil is integrated into the helmet with the treatment coil, producing similar sounds and sensations.
Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| Shipped From Abroad
The H4 Coil stimulates the bilateral insula and prefrontal cortex. Nearly 1 in 3 patients who completed 18 sessions achieved 4 or more weeks of abstinence from smoking in a large scale, double-blind, multicenter randomized controlled trial. 2 out of 3 patients who quit smoking by the end of treatment remained abstinent for at least an additional three months
Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| Shipped From Abroad
State-of-the-Art technology to measure Segmental Blood Pressures, ABI, TBI, Doppler, PVR, PPG and stress testing. Falcon advanced EMR and PACS capabilities and reporting options are designed for medical centers and private clinics alike. Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| Shipped From Abroad
The VentMed DF-30V-HM is a BiPAP (Bilevel Positive Airway Pressure) machine designed for sleep apnea therapy and non-invasive ventilation. It is ideal for individuals with obstructive sleep apnea (OSA), central sleep apnea (CSA), chronic obstructive pulmonary disease (COPD), and other respiratory disorders.
Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| ||||||||||||||||||||||||
Content | Surgeon driven system for Intraoperative NeuromonitoringFeaturesIntraoperative monitoring without the participation of a neurophysiologist Neuro-IOM/SOLO is an 8-channel intraoperative neuromonitoring system with a touchscreen, designed specifically for use by a surgeon. Participation of a neurophysiologist is not necessary. The electronic unit is equipped with a tablet, which can be placed next to the surgeon. At the same time, when stimulating nerve structures in the surgical field, the specialist sees instant responses on the display of a tablet clearly and without any insufficient information. 8 bipolar channels: monitoring of endocrine, maxillofacial and ENT operations Neuro-IOM/SOLO allows monitoring via 8 bipolar channels, which is suitable for endocrine, maxillofacial and ENT surgery. The system allows monitoring in 4 modalities - evoked and spontaneous EMG, DNS, TOF. Just turn on the device and start monitoring Working with the device is as simple as possible - to start monitoring, you just need to turn on the device and begin the operation with a preset monitoring template. There is no need to make complicated settings. Loud sound signal of different tones to indicate responses The convenience of Neuro-IOM/SOLO also lies in the speakers built into the device, which allow the operating doctor not to be distracted from actions in the surgical field. Using a special stimulating electrode, the surgeon delivers a stimulus to physiological structures during surgery and can distinguish responses by ear from different tones of sound from speakers. Wide range of consumables available With Neuro-IOM/SOLO you can use various electrodes for stimulation of neuromuscular structures - monopolar, bipolar and concentric, as well as concentric stimulating electrodes. To remove electrophysiological signals, you can use any electrodes convenient for a specialist. Their range can be found in the IOM accessories catalogue of the Neurosoft company. Basic solutions for IOM in a comfortable design Neuro-IOM/SOLO is a compact device that is equipped with a convenient folding handle that allows you to carry it comfortably. The tablet for visual display of responses can be placed on the device itself in an ergonomic magnetic mount.Additional Features
|
| The BrainsWay Deep TMS 104 RCT System is a non-invasive treatment for mental health conditions that uses magnetic pulses to stimulate the brain.
FeaturesThe BrainsWay Deep TMS 104 RCT System has several features, including:
Click here to download Brochure | The BrainsWay Deep TMS H4 Coil is a non-invasive treatment that uses magnetic energy waves to stimulate brain structures associated with addiction and weight loss:Â
| https://youtu.be/YSWvhSIS1ho?si=ZVl2aB_GXgSRotbP
Features of Falcon Physiologic Machine | This portable and home-use BiPAP device offers effective sleep therapy and is suitable for patients who require advanced respiratory support
Key Features:
Specifications:
This BiPAP machine is user-friendly, featuring an intuitive control panel and a clear display, making setup and adjustments easy for both patients and healthcare providers. It ensures stable breathing throughout the night, improving overall sleep quality ​ | ||||||||||||||||||||||||
Weight | N/A | N/A | N/A | N/A | N/A | N/A | ||||||||||||||||||||||||
Dimensions | N/A | N/A | N/A | N/A | N/A | N/A | ||||||||||||||||||||||||
Additional information |
Reviews
There are no reviews yet.