NEURO-MEP-8-EMG, NCS and EP System
$0.00
Shipped From Abroad
Research institutions conducting EMG and EP studies sometimes apply rarely used techniques such as long loop reflex, nociceptive flexor reflex (RIII reflex), triple stimulation, paired associative stimulation and others. That is why it is important that they are implemented in the device. 8-channel NCS, EMG and multi-modality EP system of expert class Neuro-MEP-8 is perfect for this purpose.
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Description
Features
Modular design
Neuro-MEP-8 system features modular design which means that you can create a configuration of your own combining amplifiers and stimulators included in the system depending on your specific needs. All electronic units can be connected to a computer via USB. It is possible to connect up to 10 different USB units whereas the system itself can be expanded up to 16 bipolar channels using an additional amplifier (purchased separately).
69 different EMG, EP and ERG techniques
Neuro-MEP-8 is a versatile tool packed with 69 different EMG, TMS, EP (including cognitive), ERG and EOG techniques.
Video EMG
The system ensures synchronous recording and reviewing of EMG data together with video including that obtained from the laryngoscope and other endoscopes.
Amplifiers and stimulators with fully customizable settings
Fully customizable settings of amplifiers and stimulators, possibility to create user-defined examination types and the most complex stimulation and biosignal (macros) acquisition protocols is truly unrivaled.
Native data export in .xml, .edf, .bdf and text formats
No matter if you use different methods of data processing, you can always export the data in various formats and process it using your own mathematics software.
Quick Comparison
NEURO-MEP-8-EMG, NCS and EP System remove | Dolphin-4D Transcranial Doppler Probe remove | Ectron Ectonustim Series 6 Electroconvulsive Therapy ECT Machine remove | BRAINSWAY Deep TMS H4 RCT Coil remove | Oxygen Generator/Plant remove | ND-8S EEG Monitor remove | |
---|---|---|---|---|---|---|
Name | NEURO-MEP-8-EMG, NCS and EP System remove | Dolphin-4D Transcranial Doppler Probe remove | Ectron Ectonustim Series 6 Electroconvulsive Therapy ECT Machine remove | BRAINSWAY Deep TMS H4 RCT Coil remove | Oxygen Generator/Plant remove | ND-8S EEG Monitor remove |
Image | ![]() | ![]() | ![]() | ![]() | ![]() | ![]() |
SKU | SF1033560130187-17 | SF1033560130142-1 | SF10335601235 | SF1033560130162-8 | SF103356013076 | |
Rating | ||||||
Price |
|
|
|
|
|
|
Stock | ||||||
Availability | ||||||
Add to cart | ||||||
Description | Shipped From Abroad
Research institutions conducting EMG and EP studies sometimes apply rarely used techniques such as long loop reflex, nociceptive flexor reflex (RIII reflex), triple stimulation, paired associative stimulation and others. That is why it is important that they are implemented in the device. 8-channel NCS, EMG and multi-modality EP system of expert class Neuro-MEP-8 is perfect for this purpose.
Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| Shipped From Abroad
The cutting-edge technology of the standalone Dolphin/4D transcranial Doppler system is the optimal TCD solution for measurements of cerebral blood flow velocities.
Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| Shipped From Abroad
This machines have been developed from the well-proven Series 5A and 5B ECT apparatus. The series 6+ models incorporate all the features of the corresponding Series 5B versions. Experience has shown that a very few patients sometimes require higher dosage than was available with the earlier machines and the opportunity was therefore taken to produce equipment with a second, higher, output range. Delivery & Availability: Typically 3 Months – excluding furniture and heavy/bulky equipment. Please contact us for further information. | Shipped From Abroad
The H4 Coil stimulates the bilateral insula and prefrontal cortex. This includes neurons in brain structures associated with addiction. A sham coil is integrated above the treatment coil. To the patient and operator, the helmet appears the same, pulses sound the same, and stimulation feels the same on the scalp.
Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| Shipped From Abroad
PSA Medical & Industrial oxygen generator systems produce gas oxygen from compressed air from the field where they work and switch compatible to conventional oxygen gas source such as tubes or cryogenic liquid.
Delivery & Availability:
Typically, 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| Shipped From Abroad
Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
|
Content | FeaturesModular design Neuro-MEP-8 system features modular design which means that you can create a configuration of your own combining amplifiers and stimulators included in the system depending on your specific needs. All electronic units can be connected to a computer via USB. It is possible to connect up to 10 different USB units whereas the system itself can be expanded up to 16 bipolar channels using an additional amplifier (purchased separately). 69 different EMG, EP and ERG techniques Neuro-MEP-8 is a versatile tool packed with 69 different EMG, TMS, EP (including cognitive), ERG and EOG techniques. Video EMG The system ensures synchronous recording and reviewing of EMG data together with video including that obtained from the laryngoscope and other endoscopes. Amplifiers and stimulators with fully customizable settings Fully customizable settings of amplifiers and stimulators, possibility to create user-defined examination types and the most complex stimulation and biosignal (macros) acquisition protocols is truly unrivaled. Native data export in .xml, .edf, .bdf and text formats No matter if you use different methods of data processing, you can always export the data in various formats and process it using your own mathematics software. Download Brochure | https://youtu.be/Id0Ma1_lEo0?si=MmwcCTMMPZd_jf6h
Features of Dolphin TCD Machine | This machines have been developed from the well-proven Series 5A and 5B ECT apparatus. The series 6+ models incorporate all the features of the corresponding Series 5B versions. Experience has shown that a very few patients sometimes require higher dosage than was available with the earlier machines and the opportunity was therefore taken to produce equipment with a second, higher, output range.
Features:
Constant Current stimulus
Delivered Dosage Displayed
Patient Dynamic Impedance Indicator
Simple Single Dose Control
Technical Specification:
Input Supply: AC 100-120, 210-240 V 40/60 Hz
Load: 70 W
Apparatus Size: 305 x 170 x 105mm (12” x 6.5” x 4”)
Weight: 3.24kg
Low Range: 50-700mC @ 750mA
High Range: 200-100mC @ 900mA
Contents:
Two-hand headpiece: 1
C.S lead: 1
Disposable electrodes: 50
Mains cable: 1
Operating & service manual: 1
Removable stand: 1
Click Here To Download Catalogue | Features
| PSA Medical & Industrıal oxygen generator systems produce gas oxygen from compressed air from the field where they work and switch compatible to conventional oxygen gas source such as tubes or cryogenic liqiud.
OXYGEN PURITY - PSA oxygen generators, continuously 90-95% purity oxygen produces. OXYGEN FLOW - LINAIR TECHNOLOGIES manufactures oxygen generators with capacities from 1 Nm3/h to 1000 Nm3/h. OXYGEN OUTLET PRESSURE - Oxygen generators produces 4-6 bar oxygen. ADVANTAGES OF OXYGEN GENERATORS/Plant
| FeaturesHIE multi-dimensional identification and application 1) According to the amplitude and continuity of the upper/lower boundary of aEEG, the neonatal EEG activity will be classified, and the Hellstrom-Westas background five-classification method will be used to improve the ability of medical staff to identify the aEEG waveforms; 2) Masimo Rainbow SET pulse oximetry monitoring, monitor the SpO2/PI/PR change in a non-invasive and continuous manner, effectively eliminate the exercise interference, and improve the measurement performance under low perfusion and body motion.
|
Weight | N/A | N/A | N/A | N/A | N/A | N/A |
Dimensions | N/A | N/A | N/A | N/A | N/A | N/A |
Additional information |
Reviews
There are no reviews yet.