NEURO-MS/D-Therapeutic Transcranial Magnetic Stimulator
$0.00
Shipped From Abroad
NEURO-MS/D is a Therapeutic Transcranial Magnetic Stimulator (TMS) designed for non-invasive neuromodulation to treat various neurological and psychiatric conditions. Using focused magnetic pulses, it stimulates targeted areas of the brain, promoting neuroplasticity and aiding in recovery from disorders such as depression, anxiety, and chronic pain. Ideal for clinicians and therapists, the NEURO-MS/D offers safe, effective, and customizable treatment options with advanced technology and a user-friendly interface for enhanced patient care.
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Description
Features
Effective motor function recovery
Transcranial magnetic stimulation (TMS) is a valuable diagnostic and therapeutic technique that is encouraged for wide use in neurorehabilitation and electrodiagnostics in both adults and children.
TMS can be used for motor function recovery after spinal (spinal cord injury, myelitis) or brain (stroke, traumatic brain injury and other focal brain damage) conditions.
Application: post-stroke rehabilitation, spasticity, pain syndrome, migraine, Parkinson disease, tinnitus, dystonia, essential tremor, Tourette syndrome, amyotrophic lateral sclerosis, multiple sclerosis, epilepsy, Alzheimer disease.
Noninvasive and painless stimulation
TMS is a painless procedure which does not have absolute contraindications if compared, for example, to electrical stimulation. At the same time TMS therapy has been proven effective and is successfully applied all over the world.
Reliable performance for everyday practice
Our Neuro-MS/D magnetic stimulator allows for deep focused stimulation of the brain ensuring long-term therapeutic effect whereas implying minimum contraindications and side effects. A well-thought design concept of Neuro-MS/D magnetic stimulator facilitates its efficient use.
Neurosoft magnetic stimulators are a popular choice of healthcare professionals who look for quality, safety and robustness.
Innovative liquid cooling technology
Overheating is a common issue for magnetic stimulators as repetitive stimulation implies delivery of a large number of pulses during the treatment session. This may result in coil overheating which explains the need to use cooled coils. Neurosoft magnetic stimulators feature the breakthrough cooling system solution when the coolant does not fill the coil completely and just circulates inside the winding neutralizing heat right at the spot and at the same time contributes to less heavy coil design.
Sophisticated software with automatic algorithms and pre-defined treatment protocols
The supplied software features pre-defined protocols for treatment of psychiatric and neurological disorders according to IFCN (International Federation of Clinical Neurophysiology) recommendations. Smart software allows saving your precious time when performing TMS.
Additional Features
- effective motor function recovery
- noninvasive and painless stimulation
- reliable performance for everyday practice
- innovative liquid cooling technology
- sophisticated software with automatic algorithms and pre-defined treatment protocols
Quick Comparison
Settings | NEURO-MS/D-Therapeutic Transcranial Magnetic Stimulator remove | Dolphin-XF Transcranial Robotic Probe remove | BRAINSWAY Deep TMS H4 Coil remove | RESCUE LIFE 9 AED DEFIBRILLATOR with Temp, Spo2, Pacemaker remove | BRAINSWAY Deep TMS H4 RCT Coil remove | Oxygen Generator/Plant remove |
---|---|---|---|---|---|---|
Name | NEURO-MS/D-Therapeutic Transcranial Magnetic Stimulator remove | Dolphin-XF Transcranial Robotic Probe remove | BRAINSWAY Deep TMS H4 Coil remove | RESCUE LIFE 9 AED DEFIBRILLATOR with Temp, Spo2, Pacemaker remove | BRAINSWAY Deep TMS H4 RCT Coil remove | Oxygen Generator/Plant remove |
Image | ![]() | ![]() | ![]() | ![]() | ![]() | ![]() |
SKU | SF1033560130187-29 | SF1033560130142-4 | SF1033560130162-7 | SF10335601298-1 | SF1033560130162-8 | SF103356013076 |
Rating | ||||||
Price |
| $6,270.00 |
|
|
|
|
Stock | ||||||
Availability | ||||||
Add to cart | ||||||
Description | Shipped From Abroad
NEURO-MS/D is a Therapeutic Transcranial Magnetic Stimulator (TMS) designed for non-invasive neuromodulation to treat various neurological and psychiatric conditions. Using focused magnetic pulses, it stimulates targeted areas of the brain, promoting neuroplasticity and aiding in recovery from disorders such as depression, anxiety, and chronic pain. Ideal for clinicians and therapists, the NEURO-MS/D offers safe, effective, and customizable treatment options with advanced technology and a user-friendly interface for enhanced patient care.
Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| Shipped From Abroad
Proudly introducing the X-Factor in TCD robotic solutions, assisting in obtaining bilateral TCD insonations in as quickly as just a few seconds!. Designed for short and long-term monitoring, for use in anesthesia, in the ICU, or in the TCD lab.
Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| Shipped From Abroad
The H4 Coil stimulates the bilateral insula and prefrontal cortex. Nearly 1 in 3 patients who completed 18 sessions achieved 4 or more weeks of abstinence from smoking in a large scale, double-blind, multicenter randomized controlled trial. 2 out of 3 patients who quit smoking by the end of treatment remained abstinent for at least an additional three months
Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| Shipped From Abroad
Lightweight, ergonomic, attractive and robust portable device. Rescue Life 9 provides complete monitoring of parameters like 12 channels ECG, HR, SpO2, NIBP, Temperature and EtCO2. Synchronized cardioversion and external pacemaker in fixed or demand mode.
Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| Shipped From Abroad
The H4 Coil stimulates the bilateral insula and prefrontal cortex. This includes neurons in brain structures associated with addiction. A sham coil is integrated above the treatment coil. To the patient and operator, the helmet appears the same, pulses sound the same, and stimulation feels the same on the scalp.
Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| Shipped From Abroad
PSA Medical & Industrial oxygen generator systems produce gas oxygen from compressed air from the field where they work and switch compatible to conventional oxygen gas source such as tubes or cryogenic liquid.
Delivery & Availability:
Typically, 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
|
Content | FeaturesEffective motor function recovery Transcranial magnetic stimulation (TMS) is a valuable diagnostic and therapeutic technique that is encouraged for wide use in neurorehabilitation and electrodiagnostics in both adults and children. TMS can be used for motor function recovery after spinal (spinal cord injury, myelitis) or brain (stroke, traumatic brain injury and other focal brain damage) conditions. Application: post-stroke rehabilitation, spasticity, pain syndrome, migraine, Parkinson disease, tinnitus, dystonia, essential tremor, Tourette syndrome, amyotrophic lateral sclerosis, multiple sclerosis, epilepsy, Alzheimer disease. Noninvasive and painless stimulation TMS is a painless procedure which does not have absolute contraindications if compared, for example, to electrical stimulation. At the same time TMS therapy has been proven effective and is successfully applied all over the world. Reliable performance for everyday practice Our Neuro-MS/D magnetic stimulator allows for deep focused stimulation of the brain ensuring long-term therapeutic effect whereas implying minimum contraindications and side effects. A well-thought design concept of Neuro-MS/D magnetic stimulator facilitates its efficient use. Neurosoft magnetic stimulators are a popular choice of healthcare professionals who look for quality, safety and robustness. Innovative liquid cooling technology Overheating is a common issue for magnetic stimulators as repetitive stimulation implies delivery of a large number of pulses during the treatment session. This may result in coil overheating which explains the need to use cooled coils. Neurosoft magnetic stimulators feature the breakthrough cooling system solution when the coolant does not fill the coil completely and just circulates inside the winding neutralizing heat right at the spot and at the same time contributes to less heavy coil design. Sophisticated software with automatic algorithms and pre-defined treatment protocols The supplied software features pre-defined protocols for treatment of psychiatric and neurological disorders according to IFCN (International Federation of Clinical Neurophysiology) recommendations. Smart software allows saving your precious time when performing TMS.Additional Features
| https://youtu.be/JwSJvUVJrxo?si=6QkpitWAwvZZSwOM
DescriptionThe Dolphin/XF is a new breakthrough development in TCD robotics. It is designed to assist the user in quickly and automatically insonating and monitoring cerebral blood flow.Features | The BrainsWay Deep TMS H4 Coil is a non-invasive treatment that uses magnetic energy waves to stimulate brain structures associated with addiction and weight loss:
| Progetti Rescue Life 9 is designed for out-of-hospital and hospital use.
Lightweight, ergonomic, attractive and robust portable device. Rescue Life 9 provides complete monitoring of parameters like 12 channels ECG, HR, SpO2, NIBP, Temperature and EtCO2. Synchronized cardioversion and external pacemaker in fixed or demand mode. Three operating modes: manual, AED, Advisory. Capnography waveform. Auto-test mode verifies device functions, battery status and charge-discharge system with real-time data management and report printing. The IPX4 permits operations under adverse climatic situations.
Rescue Life 9 Technical Specification:
General requirements
• Dimension: 335x225x360 mm
• Weight: 6.5 kg with dual batteries
• Electrical: AC 100-240 VAC, 50/60 Hz
• Rechargeable Lithium-ion batteries: 15.0 V - 3.2 Ah
• Battery Operation Time:
>5 hours, with 1 battery
>10 hours with 2 batteries
• Charge Time: Max. 3 hours
• Capacity: 150 shocks with 1 battery or 300 shocks with 2 batteries at 230J fully charged
• Software: Voice and text multi-language
• Memory: Internal flash for ECG data, events and usage review
Defibrillation
• Waveform: Biphasic Truncated Exponential (BTE), HiCAP technology (Large storage capacitor)
• Impedance: Compensated, range 25-200 Ohm
• Charge time: 6 sec for 230 J with the battery fully charged
AED mode
• Energy: Fixed energy at 200 J
• Protocol: ERC 2015 CPR Guidelines with voice and text prompts
• Shockable rhythms: VF with amplitude > 0.15 mV and VT with rhythm >150 bpm
• Sensitivity: Shockable rhythm -VF > 95%, -VT > 75%
• Specificity: According to ERC 2015,
• Normal sinusoidal rhythm > 99%
• Asystole and other non-shockable rhythms > 99%
Manual mode
• Energy range: 1-230 J (from 1-10 J in 1 J steps; from 10 to 230 J in 10 J steps)
• Commands: Multifunction trim knob
• Charge and shock button in the front panel
• Operating mode: EC G «R» wave synchro or async mode
• Indicators: Battery and main led indicators
Display
• Type: High contrast TFT colour LCD 8” (800x600 dots)
• Information: ECG traces, SpO2, NIBP, EtCO2, TEMP, Heart Rate indicator, filters, alarms and the batteries status
• Display mode: Can select 3, 6, 12 ECG leads
Ecg monitoring
• Bandwidth:
0.05 - 120 Hz (-3 db) in diagnostic mode
0.6 - 40 Hz (-3 db) in monitoring mode
• CMRR: > 98 dbv Input impedance: > 50 Mohm
• Input:
Patient cable 5 leads (I, II, III, aVL, aVF, aVR, V) - standard
Patient cable 10 leads (I, II, III, aVL, aVF, aVR, V1…..V6) - optional
• Speed: 5, 10, 25, 50 mm/sec
• Filters: 50/60 Hz, EMG Filter, base line
• HR range: 20-300 bpm (~2%), digital readout on the display
• Alarm: HR max settable 250 bpm; HR min 20 bpm
SpO2 (only 55505-55512)
• SpO2 range: 0-100% HR range: 30-250 bpm
• Accuracy: 70-100% ~2% for adults with finger clip sensor
• Alarm: Adjustable min 50%
Temperature
• Probe type: YSI400 compatible
• Range: 0 to 50° C
• Resolution: ±0.1° C
Standard
• IEC 60601-2-4; IEC 60601-1; IEC 60601-1-2; IEC 63204, IEC 62366-1
• CE Mark EEC 93/42: Medical device, Class IIb
• Isolation: ECG type CF, Defibrillation type BF
• Waterproof: Class IP54
| Features
| PSA Medical & Industrıal oxygen generator systems produce gas oxygen from compressed air from the field where they work and switch compatible to conventional oxygen gas source such as tubes or cryogenic liqiud.
OXYGEN PURITY - PSA oxygen generators, continuously 90-95% purity oxygen produces. OXYGEN FLOW - LINAIR TECHNOLOGIES manufactures oxygen generators with capacities from 1 Nm3/h to 1000 Nm3/h. OXYGEN OUTLET PRESSURE - Oxygen generators produces 4-6 bar oxygen. ADVANTAGES OF OXYGEN GENERATORS/Plant
|
Weight | N/A | N/A | N/A | N/A | N/A | N/A |
Dimensions | N/A | N/A | N/A | N/A | N/A | N/A |
Additional information |
Reviews
There are no reviews yet.