New

Neuro-TES-Transcranial Electrical Stimulator

$0.00

Shipped From Abroad

Neuro-TES is a Transcranial Electrical Stimulator (TES) designed for precise neuromodulation and intraoperative neuroprotection. It delivers controlled electrical stimulation to the brain and nervous system, aiding in motor cortex mapping, functional monitoring, and rehabilitation. Ideal for neurologists, neurosurgeons, and physiatrists, Neuro-TES ensures safe and effective stimulation, enhancing patient outcomes in neurosurgery and neurorehabilitation. With advanced technology and a user-friendly interface, it provides reliable performance in both clinical and research settings.

Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Brands:: Neurosoft

Description

Stimulus Intensity – 1000 V

Neuro-TES transcranial electrical stimulator is intended for stimulation of motor cortex to record motor evoked potentials from muscles. These potentials allow to estimate the integrity of motor pathways.

Main Specifications:
  • stimulus intensity – 0-1000 V with 5 V step;
  • maximum pulse current – 1.5 A;
  • pulse duration – 40 μs, 50 μs, 60 μs, 70 μs, 80 μs, 200 μs;
  • pulse waveform – biphasic, monophasic;
  • stimulation type: single pulse, train, double train, train + pulse;
  • number of pulses in train – 1-9.

The electrical stimulator is powered via USB.

Application in Intensive Care Units and Operating Rooms

The electrical stimulator can be used together with IOM system in intensive care units, operating rooms and experimental laboratories of research institutions to:

  • estimate the central nervous system state;
  • study the human neuromuscular system at intraoperative neurophysiological monitoring.

Synchronization with Neurosoft Diagnostic System or Third-party Equipment

The electrical stimulator can operate as a part of IOM system manufactured by Neurosoft or IOM system of third-party manufacturer.
The synchronization of electrical stimulator with Neurosoft equipment is done via USB. To synchronize the electrical stimulator with IOM systems of third-party manufacturer the trig in/out is used.

4-Channel Electronic Switch

The electrical stimulator can be supplied with a 4-channel electronic switch which is placed in a patient zone in a 5-meter distance from the stimulator and control PC.
You can select the following switch:

  • electronic switch;
  • mechanical switch with external pod.

Neuro-TES software performs the switching in case the stimulator is used with electronic switch. If the stimulator is supplied with mechanical switch, use knobs on its front panel to perform the switching.

Download Brochure

Reviews

There are no reviews yet.

Be the first to review “Neuro-TES-Transcranial Electrical Stimulator”

Your email address will not be published. Required fields are marked *

Quick Comparison

SettingsNeuro-TES-Transcranial Electrical Stimulator removeND-8S EEG Monitor removeFalcon-ABI+ Transcranial Doppler Probe removeNitrogen Generator/Plant removeBRAINSWAY Deep TMS H4 RCT Coil removeDolphin-MAX Transcranial Doppler Probe remove
NameNeuro-TES-Transcranial Electrical Stimulator removeND-8S EEG Monitor removeFalcon-ABI+ Transcranial Doppler Probe removeNitrogen Generator/Plant removeBRAINSWAY Deep TMS H4 RCT Coil removeDolphin-MAX Transcranial Doppler Probe remove
Image
SKUSF1033560130142-7SF103356013077SF1033560130142-2
Rating
Price

$0.00

$0.00

$0.00

$0.00

$0.00

$0.00

Stock
Availability
Add to cart

DescriptionShipped From Abroad Neuro-TES is a Transcranial Electrical Stimulator (TES) designed for precise neuromodulation and intraoperative neuroprotection. It delivers controlled electrical stimulation to the brain and nervous system, aiding in motor cortex mapping, functional monitoring, and rehabilitation. Ideal for neurologists, neurosurgeons, and physiatrists, Neuro-TES ensures safe and effective stimulation, enhancing patient outcomes in neurosurgery and neurorehabilitation. With advanced technology and a user-friendly interface, it provides reliable performance in both clinical and research settings.
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad

Early diagnosis and early treatment, are dedicated to the "stationary" solutions for brain function diagnosis and treatment.

Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad
PSA Industrıal nitrogen generator systems produce gas nitrogen from compressed air from the field where they work, and switch compatible to conventional nitrogen gas source such as tubes or cryogenic liqiud. Delivery & Availability: Typically, 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad The H4 Coil stimulates the bilateral insula and prefrontal cortex. This includes neurons in brain structures associated with addiction. A sham coil is integrated above the treatment coil. To the patient and operator, the helmet appears the same, pulses sound the same, and stimulation feels the same on the scalp.
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad Transcranial Doppler machine with an integrated rechargeable battery. The Dolphin/MAX is the ideal portable TCD system for measurements of cerebral blood flow in Neurology, ICU, and Neurosurgery settings
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
ContentStimulus Intensity – 1000 V Neuro-TES transcranial electrical stimulator is intended for stimulation of motor cortex to record motor evoked potentials from muscles. These potentials allow to estimate the integrity of motor pathways.
Main Specifications:
  • stimulus intensity – 0-1000 V with 5 V step;
  • maximum pulse current – 1.5 A;
  • pulse duration - 40 μs, 50 μs, 60 μs, 70 μs, 80 μs, 200 μs;
  • pulse waveform – biphasic, monophasic;
  • stimulation type: single pulse, train, double train, train + pulse;
  • number of pulses in train – 1-9.
The electrical stimulator is powered via USB. Application in Intensive Care Units and Operating Rooms The electrical stimulator can be used together with IOM system in intensive care units, operating rooms and experimental laboratories of research institutions to:
  • estimate the central nervous system state;
  • study the human neuromuscular system at intraoperative neurophysiological monitoring.
Synchronization with Neurosoft Diagnostic System or Third-party Equipment The electrical stimulator can operate as a part of IOM system manufactured by Neurosoft or IOM system of third-party manufacturer. The synchronization of electrical stimulator with Neurosoft equipment is done via USB. To synchronize the electrical stimulator with IOM systems of third-party manufacturer the trig in/out is used. 4-Channel Electronic Switch The electrical stimulator can be supplied with a 4-channel electronic switch which is placed in a patient zone in a 5-meter distance from the stimulator and control PC. You can select the following switch:
  • electronic switch;
  • mechanical switch with external pod.
Neuro-TES software performs the switching in case the stimulator is used with electronic switch. If the stimulator is supplied with mechanical switch, use knobs on its front panel to perform the switching. Download Brochure
Features
HIE multi-dimensional identification and application 1) According to the amplitude and continuity of the upper/lower boundary of aEEG, the neonatal EEG activity will be classified, and the Hellstrom-Westas background five-classification method will be used to improve the ability of medical staff to identify the aEEG waveforms; 2) Masimo Rainbow SET pulse oximetry monitoring, monitor the SpO2/PI/PR change in a non-invasive and continuous manner, effectively eliminate the exercise interference, and improve the measurement performance under low perfusion and body motion.
  • Rechargeable battery Equipped with a rechargeable lithium-ion battery to support 2h independent working time, which is convenient for transfer of patient.
  • Real-time detection of electrode impedance Provide the function of real-time detection of electrode impedance to ensure the validity of the detection information.
  • Stable integrated medical trolley Compliant with the allowable load in IEC60601-1, more stable than ordinary trolleys, easy to move, and special for bedside monitoring.
     
  • Epilepsy rapid identification and application 1) Envelope trend chart (ENVELOPE) is used to represent the change in the EEG amplitude, which can better eliminate the artifacts caused by interference and identify epileptic seizure events more accurately; 2) TP (total power), also known as total energy, reflects the change in the EEG amplitude and has high sensitivity and low specificity for clinically detecting epileptic seizures.
 
  • Medical all-in-one machine - "intuitive display in the multi-trend chart" 1) Complies with the EU CE-related: EN60601-1-2: 2015 and EN60601-1: 2006 standards, with better hardware security, stability, durability, and anti-interference; 2) Equipped with a 19-inch color touch medical-grade display screen, displays each trend chart and corresponding values clearly and intuitively; 3) Provides a variety of trend chart displays and real-time EEG displays to help clinicians interpret data in time and ensure the accuracy of clinical diagnosis.
 
  • Signal amplifier - "multi-channel signal acquisition" 1) Standard 4 channels and optional 8/12 channels, with impedance selection button, built-in SpO2 input channel, less interference from the environment, and more stable signal acquisition; 2) With strong anti-interference performance, it can also record high-quality electrophysiological signals in the complex NICU and operating room environments and during the transfer process.
 
  • High-definition night-vision video monitoring 1) The optional high-definition camera with night vision function supports horizontal and vertical rotation, and the illumination distance can be up to 20m; 2) The physical movement of patients can be monitored in a real-time manner through the LCD screen, eliminate artifacts caused by various interference, and detects EEG signals accurately.
https://youtu.be/YSWvhSIS1ho?si=3W6Cb6LTqWccEtiz
Features of Falcon Physiologic Machine

Segmental Blood Pressures

Measure lower extremity pressures easily with 10 color-coded channels and a variety of Doppler probes and PPG sensors. Complete the vascular diagnosis with supportive stress testing. Falcon is considered by many the best segmental pressure machine with numerous advanced features such as 10 simultaneous PVR measurements and limitless post-processing capabilities.

Fast and Accurate ABI & TBI

Quickly measure ABI and TBI with either Doppler or Photoplethysmography (PPG). With the Falcon ABI and TBI machine, all measurements are saved automatically and sent directly to the dedicated interactive summary screen.  

High Quality Doppler Probes

In addition, to the 4 MHz and 8 MHz probes for standard use, the advanced Falcon/Quad and Falcon/Pro Doppler machines offer a unique 10 MHz probe, which is designed to measure particularly small peripheral blood vessels. All Falcon Doppler probes produce complete high-resolution Doppler spectral analysis with the aid of the Falcon vascular software and algorithms.

State-of-the-Art PPG Sensors

Falcon offers a wide selection of Photoplethysmography sensors.   The 5 completely independent PPG ports allow simultaneous fingers/toes measurements, which is especially useful for Raynaud’s diagnosis along with a an integrated temperature sensor.  Fingerclip and Toeclip PPG sensors are recommended for routine examinations. The Disc PPG sensors are particularly useful for Venous Reflux testing and are supplied with dedicated adhesive stickers.  

Highest Durability and Reliability

The Falcon is the most reliable peripheral vascular machine in the market.  Thanks to the high quality Doppler probes, 10 Independent Pressure Channels (IPU Technology) and 5 PPG Ports, the Falcon design significantly reduces any down-time.  Falcon is in distributed worldwide for over 10 years with the lowest fail rate in the market!

Complete Network Connectivity

The Falcon unmatched connectivity capabilities are a paradise to hospital IT personnel and EMR and PACS managers. The advanced networking abilities allow a plug-and-play operation to easily configure connectivity with automated DICOM Worklist & Storage, Structured Report, and HL7. With unlimited Review Stations, measurements can be reanalyzed and interpreted from the comfort of your office. Final reporting can also be configured and finalized from any location.

Simplify Your Workflow

The Falcon vascular diagnosis device has the ability to configure as many dedicated examination protocols that allow to save time and optimize the patient vascular diagnosis​. Enjoy the user-friendly protocol builder to configure your workflow according to your needs!​

Ease of Use

Minimal learning curve thanks to user-friendly software with a large touch-screen display. A selection of wired and wireless remote control​ and footswitch allows keeping your focus on the patient rather than on the physiologic vascular equipment.

Dedicated Specialty Tests

The Falcon is the complete vascular physiologic assessment machine with dedicated protocols that guide you through step-by-step diagnostic measurements of specific vascular conditions.  The dedicated diagnosis protocols include measurements of Thoracic Outlet Syndrome (TOS), diagnosis of Raynaud’s Phenomenon, evaluation of Penile Function or Erectile Dysfunction, assessment of Allen’s Test (or Palmar Arch Test), measurements of Venous Reflux and Venous Capacitance and Outflow, Pulse Wave Velocity, and more.

Advanced Reporting

The famous Falcon user-friendly report builder tool allows you to design your own report layout easily. Then, add your institute/clinic logo and details to create a detailed and impressive diagnosis report that meets your institute standards. Save a lot of time by building your report with preconfigured interpretation templates.

Advanced Research Options

The Falcon vascular research machine is famous for its built-in statistics tool with on-screen graphs, segments filtering, and Excel tool, which are all designed to simplify the work of vascular and physiological researchers. Export to PDF, Excel, Word, JPEG, VSX, Video clips, and more to support your vascular research and teaching needs, as well as support your clinical vascular publications.
PSA Industrıal nitrogen generator systems produce gas nitrogen from compressed air from the field where they work, and switch compatible to conventional nitrogen gas source such as tubes or cryogenic liqiud.

ADVANTAGES OF NITROGEN GENERATORS/PLANT

  • High flow capacity: The wide product range and gas flows exceeding 1,000 Nm³/h

  • Desired purity: Nitrogen concentrations from 95% to 99.999%.

  • Continuous availability: 24 hours a day, 7 days a week

  • Cost savings: Low operating expenses, limited maintenance costs.

  • Fully automated and monitored including oxygen sensor as standard.

Wide Range Of Applications

  • Food & beverage (storage & packaging).

  • Pharmaceutical applications.

  • Plastic injection molding.

  • Electronics.

  • Laser cutting.

  • Semiconductor manufacturing.

  • Chemical applications.

  • Metal heat treatment.

  • Cable & optical fiber industries.

  • Glass industries.

  • Fire prevention.

  • Aquaculture.

grafik_son.jpg
Features
  • Targets the bilateral insula and prefrontal cortexThe H4 Coil stimulates brain structures associated with addiction. 
  • FDA-cleared for smoking addiction treatmentThe H4 Coil was cleared by the FDA to treat smoking addiction in adults. 
  • Integrated sham coilThe helmet includes a sham coil that has similar acoustic artifacts and scalp sensations as the active coil. This helps maintain blinding. 
  • Embedded in a cushioned, cooled helmetThe H-Coils are integrated into a helmet that includes a touchscreen interface, adjustable positioning arm, and foot pedal operation. 
  • Delivers electromagnetic pulsesThe H4 Coil generates electromagnetic pulses that stimulate neurons in the brain. 
  • Reaches deeper and broader brain regionsThe H-Coil design allows for deeper and broader stimulation than traditional TMS coils. 
  • Noninvasive treatmentDeep TMS is a noninvasive treatment that is well-tolerated and doesn't require a significant recovery period. 

Click here to download Brochure

https://youtu.be/Id0Ma1_lEo0?si=-B5sGwSCDZOQi-ZO
Features of Dolphin TCD Machine

Best Quality Doppler

Fully digital Doppler technology with the amazing Dolphin TCD post-processing capabilities. Review and replay the blood flow waveforms with audio at ANY depth. Discover unmatched clinical diagnosis capabilities.

Best TCD Robotic Probe

The unique Dolphin/XF robotic probe changes the Transcranial Doppler monitoring market as is known to date. Fast and simple scanning is achieved thanks to special algorithms and processes for blood flow detection. The Dolphin/XF robot is comfortable and stable, simplifying probe fixation and saving time.

Continuous Monitoring Made Easy

The Dolphin TCD Products are designed to assist in performing short or long-term patient monitoring. The famous Dolphin Quick-Lock provides the best locking solution. The TCD software is rich with quality features for optimal patient diagnosis.

Unbeatable Durability and Reliability

The Dolphin is considered by many as the most reliable Transcranial Doppler machine in the market. Robust TCD equipment and high-quality Doppler probes are designed for all TCD clinical applications.

Designed for Portability

The slim and lightweight design of the Dolphin TCD machines allows ideal and comfortable portability. The large touch screen can easily be seen from a distance. Mounting the TCD on a trolley is simple and easy. The Dolphin/MAX has a built-in integrated battery that lasts for hours.

Complete Network Connectivity

The unmatched Dolphin connectivity capabilities are ideal for hospital IT personnel and EMR / PACS administrators. Simple plug-and-play operation allows connectivity configuration with automated DICOM Worklist & Storage, Structured Report, and HL7. Unlimited Review Stations for interpretation and reporting in the comfort of your office.

Unmatched HITS Detection

Simultaneous counts of suspected embolic events in all depth gates using a high-resolution proprietary algorithm. Includes numerous advanced emboli analysis options with the proprietary super high-resolution power M Mode display during HITS detection.
WeightN/AN/AN/AN/AN/AN/A
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • Rating
  • Price
  • Description
Click outside to hide the comparison bar