/

Neuron Spectrum 61..65 EEG

$0.00

Shipped From Abroad

The Neuron-Spectrum 61–65 EEG series offers advanced neurophysiological diagnostic systems with 11 to 39 channels, supporting ICU monitoring, routine EEG, long-term video EEG, and polysomnography. These systems feature real-time impedance monitoring, multimodal stimulation, and high-quality data acquisition for clinical and research applications.

Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
SF1033560130187-1
Brands:: Neurosoft

Description

 

Features

Flexible software

The advantage of the Neuron-Spectrum.NET software is its wide functionality. You can use the simple interface, or you can customize the software using the special settings.

Before the study, you may choose the pre-defined electrode montage or create your own one depending on the type of test you perform. Using the convenient navigation tools, you can quickly view the recorded EEG curves, highlight artifacts, and arrange epochs. For the advanced analysis of recorded data, the contemporary tools for mathematical analysis of EEG are used. The automatic report is generated using the preset report templates and integrated glossary. The report is easily edited, saved to PDF, printed or sent automatically.

Electrode impedance indication at the lead inputs

The impedance indicators on the amplifier ensure the continuous impedance monitoring during the acquisition, timely correction of electrode placement and good quality of EEG recording.

Operation mode can be switched with just one button on the front panel. The LED indicator next to the button shows the mode: acquisition, EEG monitoring or impedance measurement. It makes the EEG study much easier.

Electrodes and caps of various manufacturers

During the study, the disk, cup and bridge electrodes as well as the electrode caps of different sizes can be applied. They are connected to the amplifier unit via touch-proof connectors and standard plug.

Operation in unshielded environments

The EEG systems of Neuron-Spectrum line can be used in any suitable room, which is convenient for staff and comfortable for patients. The costs for preparing a specialist’s workplace are also reduced significantly. The device is small and USB powered, so you can establish your EEG lab anywhere.

Download Brochure

Reviews

There are no reviews yet.

Be the first to review “Neuron Spectrum 61..65 EEG”

Your email address will not be published. Required fields are marked *

Quick Comparison

SettingsNeuron Spectrum 61..65 EEG removeBRAINSWAY Deep TMS H7 RCT Coil removeRESCUE LIFE 9 AED DEFIBRILLATOR with Temp, Spo2, Pacemaker removeBRAINSWAY Deep TMS H4 RCT Coil removeBRAINSWAY Deep TMS H7 Coil removeDolphin-4D Transcranial Doppler Probe remove
NameNeuron Spectrum 61..65 EEG removeBRAINSWAY Deep TMS H7 RCT Coil removeRESCUE LIFE 9 AED DEFIBRILLATOR with Temp, Spo2, Pacemaker removeBRAINSWAY Deep TMS H4 RCT Coil removeBRAINSWAY Deep TMS H7 Coil removeDolphin-4D Transcranial Doppler Probe remove
Image
SKUSF1033560130187-1SF1033560130162-6SF10335601298-1SF1033560130162-8SF1033560130162-5SF1033560130142-1
Rating
Price

$0.00

$0.00

$0.00

$0.00

$0.00

$0.00

Stock
Availability
Add to cart

DescriptionShipped From Abroad The Neuron-Spectrum 61–65 EEG series offers advanced neurophysiological diagnostic systems with 11 to 39 channels, supporting ICU monitoring, routine EEG, long-term video EEG, and polysomnography. These systems feature real-time impedance monitoring, multimodal stimulation, and high-quality data acquisition for clinical and research applications.
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad The H7 Coil stimulates the anterior cingulate cortex and the medial prefrontal cortex.  Treatment is designed to regulate the CSTC circuit believed to be involved in the inhibition of impulsive behavior. A sham coil is integrated above the treatment coil. To the patient and operator, the helmet appears the same, pulses sound the same, and stimulation feels the same on the scalp.
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad
Lightweight, ergonomic, attractive and robust portable device. Rescue Life 9 provides complete monitoring of parameters like 12 channels ECG, HR, SpO2, NIBP, Temperature and EtCO2. Synchronized cardioversion and external pacemaker in fixed or demand mode.   Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad The H4 Coil stimulates the bilateral insula and prefrontal cortex. This includes neurons in brain structures associated with addiction. A sham coil is integrated above the treatment coil. To the patient and operator, the helmet appears the same, pulses sound the same, and stimulation feels the same on the scalp.
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad The H7 Coil stimulates the anterior cingulate cortex and the medial prefrontal cortex. Complementing a large-scale, double-blind, multicenter randomized controlled trial, which demonstrated strong response rates, greater than 1 in 2 OCD patients who completed 29 sessions in real clinical practice achieved sustained response.
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad The cutting-edge technology of the standalone Dolphin/4D transcranial Doppler system is the optimal TCD solution for measurements of cerebral blood flow velocities.
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Contenthttps://youtu.be/JDAsx3pO4U8?si=fzekZEwG6_K2pHgL  
Features
Flexible software The advantage of the Neuron-Spectrum.NET software is its wide functionality. You can use the simple interface, or you can customize the software using the special settings. Before the study, you may choose the pre-defined electrode montage or create your own one depending on the type of test you perform. Using the convenient navigation tools, you can quickly view the recorded EEG curves, highlight artifacts, and arrange epochs. For the advanced analysis of recorded data, the contemporary tools for mathematical analysis of EEG are used. The automatic report is generated using the preset report templates and integrated glossary. The report is easily edited, saved to PDF, printed or sent automatically. Electrode impedance indication at the lead inputs The impedance indicators on the amplifier ensure the continuous impedance monitoring during the acquisition, timely correction of electrode placement and good quality of EEG recording. Operation mode can be switched with just one button on the front panel. The LED indicator next to the button shows the mode: acquisition, EEG monitoring or impedance measurement. It makes the EEG study much easier. Electrodes and caps of various manufacturers During the study, the disk, cup and bridge electrodes as well as the electrode caps of different sizes can be applied. They are connected to the amplifier unit via touch-proof connectors and standard plug. Operation in unshielded environments The EEG systems of Neuron-Spectrum line can be used in any suitable room, which is convenient for staff and comfortable for patients. The costs for preparing a specialist’s workplace are also reduced significantly. The device is small and USB powered, so you can establish your EEG lab anywhere. Download Brochure
The Brainsway Deep TMS H7 RCT Coil is a flexible coil used in transcranial magnetic stimulation (TMS) to treat obsessive-compulsive disorder (OCD) and other neuropsychiatric conditions:
  • What it does
    The H7 Coil stimulates the medial prefrontal cortex and the anterior cingulate cortex of the brain. TMS uses magnetic pulses to create an electrical current in the brain's neuronal tissue. 
  • How it's used
    The H7 Coil is integrated into a cooled, cushioned helmet that allows the patient to move around during treatment. A sham coil is also included so that the patient and operator can't tell the difference between the treatment and sham coils. 
  • What it's used for
    The H7 Coil is FDA-cleared for OCD, but it's also been shown to be effective in treating other conditions, including addiction, major depressive disorder, and autism spectrum disorder. 
  • How it works
    The H7 Coil is designed to regulate the CSTC circuit, which is thought to be involved in impulsive behavior. 
  • Safety
    A 2023 paper that analyzed adverse events from five large, randomized controlled trials found that most adverse events were transient and resolved within days.
Features
  • Stimulates specific brain regions
    The H7 Coil targets the anterior cingulate cortex and the medial prefrontal cortex. 
  • Flexible windings
    The H7 Coil's flexible windings conform to the shape of the patient's head. 
  • FDA-cleared for OCD
    The H7 Coil is FDA-cleared for treating obsessive-compulsive disorder (OCD). 
  • Demonstrated efficacy
    The H7 Coil has been shown to be effective in treating OCD patients with varying degrees of severity and comorbidities. 
  • Integrated sham coil
    The helmet includes a sham coil that makes the treatment appear, sound, and feel the same to the patient and operator.

Click here to download Brochure

Progetti Rescue Life 9 is designed for out-of-hospital and hospital use. Lightweight, ergonomic, attractive and robust portable device. Rescue Life 9 provides complete monitoring of parameters like 12 channels ECG, HR, SpO2, NIBP, Temperature and EtCO2. Synchronized cardioversion and external pacemaker in fixed or demand mode. Three operating modes: manual, AED, Advisory. Capnography waveform. Auto-test mode verifies device functions, battery status and charge-discharge system with real-time data management and report printing. The IPX4 permits operations under adverse climatic situations.
Rescue Life 9 Technical Specification: General requirements • Dimension: 335x225x360 mm • Weight: 6.5 kg with dual batteries • Electrical: AC 100-240 VAC, 50/60 Hz • Rechargeable Lithium-ion batteries: 15.0 V - 3.2 Ah • Battery Operation Time: >5 hours, with 1 battery >10 hours with 2 batteries • Charge Time: Max. 3 hours • Capacity: 150 shocks with 1 battery or 300 shocks with 2 batteries at 230J fully charged • Software: Voice and text multi-language • Memory: Internal flash for ECG data, events and usage review Defibrillation • Waveform: Biphasic Truncated Exponential (BTE), HiCAP technology (Large storage capacitor) • Impedance: Compensated, range 25-200 Ohm • Charge time: 6 sec for 230 J with the battery fully charged
AED mode • Energy: Fixed energy at 200 J • Protocol: ERC 2015 CPR Guidelines with voice and text prompts • Shockable rhythms: VF with amplitude > 0.15 mV and VT with rhythm >150 bpm • Sensitivity: Shockable rhythm -VF > 95%, -VT > 75% • Specificity: According to ERC 2015, • Normal sinusoidal rhythm > 99% • Asystole and other non-shockable rhythms > 99%
Manual mode • Energy range: 1-230 J (from 1-10 J in 1 J steps; from 10 to 230 J in 10 J steps) • Commands: Multifunction trim knob • Charge and shock button in the front panel • Operating mode: EC G «R» wave synchro or async mode • Indicators: Battery and main led indicators Display • Type: High contrast TFT colour LCD 8” (800x600 dots) • Information: ECG traces, SpO2, NIBP, EtCO2, TEMP, Heart Rate indicator, filters, alarms and the batteries status • Display mode: Can select 3, 6, 12 ECG leads
Ecg monitoring • Bandwidth: 0.05 - 120 Hz (-3 db) in diagnostic mode 0.6 - 40 Hz (-3 db) in monitoring mode • CMRR: > 98 dbv Input impedance: > 50 Mohm • Input: Patient cable 5 leads (I, II, III, aVL, aVF, aVR, V) - standard Patient cable 10 leads (I, II, III, aVL, aVF, aVR, V1…..V6) - optional • Speed: 5, 10, 25, 50 mm/sec • Filters: 50/60 Hz, EMG Filter, base line • HR range: 20-300 bpm (~2%), digital readout on the display • Alarm: HR max settable 250 bpm; HR min 20 bpm
SpO2 (only 55505-55512) • SpO2 range: 0-100% HR range: 30-250 bpm • Accuracy: 70-100% ~2% for adults with finger clip sensor • Alarm: Adjustable min 50%
Temperature • Probe type: YSI400 compatible • Range: 0 to 50° C • Resolution: ±0.1° C Standard • IEC 60601-2-4; IEC 60601-1; IEC 60601-1-2; IEC 63204, IEC 62366-1 • CE Mark EEC 93/42: Medical device, Class IIb • Isolation: ECG type CF, Defibrillation type BF • Waterproof: Class IP54
Features
  • Targets the bilateral insula and prefrontal cortexThe H4 Coil stimulates brain structures associated with addiction. 
  • FDA-cleared for smoking addiction treatmentThe H4 Coil was cleared by the FDA to treat smoking addiction in adults. 
  • Integrated sham coilThe helmet includes a sham coil that has similar acoustic artifacts and scalp sensations as the active coil. This helps maintain blinding. 
  • Embedded in a cushioned, cooled helmetThe H-Coils are integrated into a helmet that includes a touchscreen interface, adjustable positioning arm, and foot pedal operation. 
  • Delivers electromagnetic pulsesThe H4 Coil generates electromagnetic pulses that stimulate neurons in the brain. 
  • Reaches deeper and broader brain regionsThe H-Coil design allows for deeper and broader stimulation than traditional TMS coils. 
  • Noninvasive treatmentDeep TMS is a noninvasive treatment that is well-tolerated and doesn't require a significant recovery period. 

Click here to download Brochure

The BrainsWay Deep TMS H7 Coil is a flexible coil used in transcranial magnetic stimulation (TMS) to stimulate the brain's medial prefrontal cortex and anterior cingulate cortex:
The H7 Coil stimulates the anterior cingulate cortex and the medial prefrontal cortex. Treatment is designed to regulate the CSTC circuit believed to be involved in the inhibition of impulsive behavior. A sham coil is integrated above the treatment coil.
  • What it does
    The H7 Coil is FDA-cleared to treat obsessive-compulsive disorder (OCD). It can also be used to treat other neuropsychiatric disorders, such as addiction, major depressive disorder, and autism spectrum disorder. 
  • How it works
    TMS uses magnetic pulses to induce an electrical current in the brain's neuronal tissue. The H7 Coil is integrated into a cooled, cushioned helmet that allows the patient to move around during treatment. 
  • How it's used
    The H7 Coil is designed to reach deeper and broader regions of the brain than previous TMS coils. The treatment is non-invasive and well-tolerated, with no adverse or long-lasting side effects. 
  • How it's delivered
    The treatment involves multiple sessions, each lasting about 18 minutes.
    Click here to download Brochure
https://youtu.be/Id0Ma1_lEo0?si=MmwcCTMMPZd_jf6h
Features of Dolphin TCD Machine

Best Quality Doppler

Fully digital Doppler technology with the amazing Dolphin TCD post-processing capabilities lets you review and replay the measured spectrum with audio at any depth. Unmatched clinical diagnosis capabilities.

Best TCD Robotic Probe

The unique Dolphin/XF robotic probe changes the Transcranial Doppler monitoring market as is known to date. Fast and simple scanning is achieved thanks to special algorithms and processes for blood flow detection. The Dolphin/XF robot is comfortable and stable, simplifying probe fixation and saving time.

Continuous Monitoring Made Easy

The Dolphin devices are well designed to assist the technician or physician in performing short or long-term Monitoring. The Dolphin Headset design comes with the unique probe Quick-Lock – the best locking solution. The Dolphin software is rich with quality features for optimal patient diagnosis, including a complete replay of the entire recording, placement of automatic and predefined markers, and availability of trends display.

Unbeatable Durability and Reliability

The Dolphin is considered by many as the most reliable Transcranial Doppler machine in the market. A range of high-quality Doppler probes is available for different clinical applications and optimal Doppler penetration of the temporal window.

Designed for Portability

The Dolphin TCD machines are the most portable TCD machine on the market. Dolphin/MAX and Dolphin/4D are slim, lightweight, and have a large 18″ Touch Screen, which can be seen from a distance in the ICU or other clinical settings. Their design allows you to simply hand carry them or use the VESA mount options to easily connect the TCD system to a cart or trolley. The Dolphin/MAX has a built-in integrated battery that lasts for hours.

Complete Network Connectivity

The unmatched Dolphin connectivity capabilities are ideal for hospital IT personnel and EMR / PACS administrators. The advanced Dolphin TCD networking abilities allow a simple plug-and-play operation to quickly configure connectivity with automated DICOM Worklist & Storage, Structured Report, and HL7. With unlimited Review Stations, measurements can be reanalyzed and interpreted from the comfort of your office. Final reporting can also be configured and finalized from any location.

Unmatched HITS Detection

Optimal and accurate counts of suspected embolic events using a high-resolution proprietary algorithm that simultaneously detects HITS (emboli events) in all gates! The numerous advanced analysis options of each suspected emboli include an extraordinary high-resolution power M Mode display during HITS detection (up to 50 times faster than the Doppler spectrum!).
WeightN/AN/AN/AN/AN/AN/A
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • Rating
  • Price
  • Description
Click outside to hide the comparison bar
Compare