New
/

Neuron Spectrum-6G

$0.00

Shipped From Abroad

The Neuron-Spectrum-6G by Neurosoft is an advanced EEG system developed from 30 years of engineering experience and cutting-edge technologies. It offers superior input noise levels, frequency and amplitude ranges, and sampling frequencies, outperforming many clinical EEG machines. Designed for seamless integration with transcranial magnetic stimulation (TMS), it effectively records EEG and evoked potentials during TMS sessions without signal disruptions.

Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Brands:: Neurosoft

Description

 

Features

Innovative EEG recorder with outstanding technical specifications

A new-generation EEG system, Neuron Spectrum-6G represents the 30-year experience of Neurosoft engineers and advanced technologies applied in the development of circuit solutions in medicine. The system outperforms most clinical EEG machines available today regarding such characteristics as input noise level, input frequency and amplitude range, and sampling frequency. Thanks to that and to the particularly developed software, it is possible to successfully use the system for TMS-EEG studies. The previous-generation EEG recorders usually went off-scale at the high-amplitude magnetic pulse and did not record an electroencephalogram. When designing this system, this disadvantage was fixed so that now the system allows recording of EEG and evoked potentials (EP) throughout a transcranial magnetic stimulation (TMS) session.

Non-interfering monophasic magnetic stimulator

For TMS-EEG sessions, we suggest using one of Neurosoft latest developments in magnetic stimulation. The monophasic stimulator ensures generation of high-amplitude pulses with high enough frequency. At the same time, its circuit is designed so that charging the capacitor does not cause additional interference in the EEG – the so-called “silent mode”. A variety of coils to choose from allow you to solve a wide range of clinical tasks.

Electrode system

An important success factor of the TMS-EEG technique is the appropriate electrode system. This solution offers a special electrode cap with the pre-defined electrode positions according to the 10-20 system for 21 or 32 EEG channels. The flat design of the electrodes allows positioning the coil as close to the head as possible, while the minimum metal content of the electrode allows minimizing artifact from the magnetic pulse on the EEG.

Software for recording, averaging, and analysis

 The Neuron-Spectrum.NET software implements the averaging of EPs induced by magnetic stimulation directly during recording. Automatic artifact removal from averaging allows obtaining pure responses for a minimum number of averagings. The latencies and amplitudes of EP components are calculated automatically and presented as tables and topographic maps. After the recording is completed, it is possible to change the filter parameters, perform averaging with different settings, for example, to remove pulse artifact from the averaged curves. The duration of a pulse artifact depends on the used electrodes, pulse intensity, and filter parameters. On average, artifact duration is 25 ms after pulse delivery, and immediately after that the system records pure EEG signal without interference.

Wide application possibilities

A few years ago when it became technically possible to record EEG during magnetic stimulation, TMS-EEG technique was only used in scientific research. Numerous works have now been published demonstrating the possibilities of this method in the treatment and diagnosis of various diseases. For example, TMS-EEG is widely used for evaluation of rehabilitation progress in stroke patients and helps in localization of the epileptic focus. The studies performed today using this technique allow suggesting that the scope of its application will expand even further in the future.

Reviews

There are no reviews yet.

Be the first to review “Neuron Spectrum-6G”

Your email address will not be published. Required fields are marked *

Quick Comparison

SettingsNeuron Spectrum-6G removeSomatics Electroconvulsive Therapy (ECT) Machine removeND-8S EEG Monitor removeDolphin-XF Transcranial Robotic Probe removeBRAINSWAY Deep TMS H7 RCT Coil removeFalcon-PRO Transcranial Doppler Probe remove
NameNeuron Spectrum-6G removeSomatics Electroconvulsive Therapy (ECT) Machine removeND-8S EEG Monitor removeDolphin-XF Transcranial Robotic Probe removeBRAINSWAY Deep TMS H7 RCT Coil removeFalcon-PRO Transcranial Doppler Probe remove
Image
SKUSF1033560106-1SF1033560130142-4SF1033560130142-5
Rating
Price

$0.00

$0.00

$0.00

$6,270.00

$0.00

$0.00

Stock
Availability
Add to cart

DescriptionShipped From Abroad The Neuron-Spectrum-6G by Neurosoft is an advanced EEG system developed from 30 years of engineering experience and cutting-edge technologies. It offers superior input noise levels, frequency and amplitude ranges, and sampling frequencies, outperforming many clinical EEG machines. Designed for seamless integration with transcranial magnetic stimulation (TMS), it effectively records EEG and evoked potentials during TMS sessions without signal disruptions.
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped from abroad The machine provides higher stimulus current, deeper cerebral stimulus penetration, and better seizure generalization. It provides the most effective form of bilateral brief pulse ECT with a 0.5msec pulsewidth that minimizes side-effects and can be delivered at every stimulus dose including the maximum dose with efficient and accurate stimulus titration.
Delivery & Availability: Typically 21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.  
Shipped From Abroad

Early diagnosis and early treatment, are dedicated to the "stationary" solutions for brain function diagnosis and treatment.

Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad Proudly introducing the X-Factor in TCD robotic solutions, assisting in obtaining bilateral TCD insonations in as quickly as just a few seconds!. Designed for short and long-term monitoring, for use in anesthesia, in the ICU, or in the TCD lab.
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad The H7 Coil stimulates the anterior cingulate cortex and the medial prefrontal cortex.  Treatment is designed to regulate the CSTC circuit believed to be involved in the inhibition of impulsive behavior. A sham coil is integrated above the treatment coil. To the patient and operator, the helmet appears the same, pulses sound the same, and stimulation feels the same on the scalp.
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad

State-of-the-Art technology to measure Segmental Blood Pressures, ABI, TBI, Doppler, PVR, PPG and stress testing. Falcon advanced EMR and PACS capabilities and reporting options are designed for medical centers and private clinics alike.

Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Contenthttps://youtu.be/L5JdV0DrKQs  
Features
Innovative EEG recorder with outstanding technical specifications A new-generation EEG system, Neuron Spectrum-6G represents the 30-year experience of Neurosoft engineers and advanced technologies applied in the development of circuit solutions in medicine. The system outperforms most clinical EEG machines available today regarding such characteristics as input noise level, input frequency and amplitude range, and sampling frequency. Thanks to that and to the particularly developed software, it is possible to successfully use the system for TMS-EEG studies. The previous-generation EEG recorders usually went off-scale at the high-amplitude magnetic pulse and did not record an electroencephalogram. When designing this system, this disadvantage was fixed so that now the system allows recording of EEG and evoked potentials (EP) throughout a transcranial magnetic stimulation (TMS) session. Non-interfering monophasic magnetic stimulator For TMS-EEG sessions, we suggest using one of Neurosoft latest developments in magnetic stimulation. The monophasic stimulator ensures generation of high-amplitude pulses with high enough frequency. At the same time, its circuit is designed so that charging the capacitor does not cause additional interference in the EEG – the so-called “silent mode”. A variety of coils to choose from allow you to solve a wide range of clinical tasks. Electrode system An important success factor of the TMS-EEG technique is the appropriate electrode system. This solution offers a special electrode cap with the pre-defined electrode positions according to the 10-20 system for 21 or 32 EEG channels. The flat design of the electrodes allows positioning the coil as close to the head as possible, while the minimum metal content of the electrode allows minimizing artifact from the magnetic pulse on the EEG. Software for recording, averaging, and analysis  The Neuron-Spectrum.NET software implements the averaging of EPs induced by magnetic stimulation directly during recording. Automatic artifact removal from averaging allows obtaining pure responses for a minimum number of averagings. The latencies and amplitudes of EP components are calculated automatically and presented as tables and topographic maps. After the recording is completed, it is possible to change the filter parameters, perform averaging with different settings, for example, to remove pulse artifact from the averaged curves. The duration of a pulse artifact depends on the used electrodes, pulse intensity, and filter parameters. On average, artifact duration is 25 ms after pulse delivery, and immediately after that the system records pure EEG signal without interference. Wide application possibilities A few years ago when it became technically possible to record EEG during magnetic stimulation, TMS-EEG technique was only used in scientific research. Numerous works have now been published demonstrating the possibilities of this method in the treatment and diagnosis of various diseases. For example, TMS-EEG is widely used for evaluation of rehabilitation progress in stroke patients and helps in localization of the epileptic focus. The studies performed today using this technique allow suggesting that the scope of its application will expand even further in the future.
The machine provides higher stimulus current, deeper cerebral stimulus penetration, and better seizure generalization. It provides the most effective form of bilateral brief pulse ECT with a 0.5msec pulsewidth that minimizes side-effects and can be delivered at every stimulus dose including the maximum dose with efficient and accurate stimulus titration. Features-
  • Choose 0.25, 0.3 or 0.5msec Ultrabrief Pulsewidth
  • Genie™ IV EEG Analyzing Software
  • Four (4) - Channel Monitor/Printer
  • Optimal Stimulus Programs
  • Maximum Sustained EEG Amplitude
  • Continuous Digital Heart Rate Monitor
  • Peak Heart Rate Printout
  • EEG Coherence Analysis
  • Seizure Energy Index
  • Postictal Suppression Index
  • Maximum Dose Available at all Pulsewidths
  • Interictal Frontal Delta Analysis
  • Computer EEG Seizure Duration
  • Computer Motor Seizure Duration
  • True EMG Monitor
  • EEG Ictal Line Seizure Indicator
  • Light-Emitting Elapsed Time Display
  • Up to 8 Seconds of Stimulation
  • Change Waveform without Altering Dose
  • Audible EEG™ monitor
  • Instant Impedance Test
  • Extended Seizure Alert
  • Patented Safety Monitor Circuit
ECT Machine with Standard Accessories below: Article           Qty      Description                                                                           SYS-IV            1                     Thymatron System IV , with following accessories: EGEN              1         Genie-IV EEG Analyzing Software ELDS9            1                     Set with 9 lead wires  (4 red / 4 black / 1 green) EPAD              10       Disposable ECT treatment electrodes "Thymapad" (5 Pair) ECEF-IV        1                     EEG/EMG/ECG-monitoring cable ECET-IV        1                     ECT-treatment cable EEDS              50       Pregelled EEG/EMG stick-on electrodes EMGD           2                     Mouthguard oral protectors, 2 sizes CP110            2         Z-fold chart paper EDVD             1         Audio training DVD EMAE             2         Operating manual English ESERV           1         Service manual English For further treatments you can order separately following accessories: EECU/EEFL - Stainless steel electrode, cupped (EECU) or flat (EEFL) EHST- Headstrap, latex rubber, perforated EHAN-Electrode handle, fully shielded, for flat or cupped electrode.
Click Here To Download Catalogue
Features
HIE multi-dimensional identification and application 1) According to the amplitude and continuity of the upper/lower boundary of aEEG, the neonatal EEG activity will be classified, and the Hellstrom-Westas background five-classification method will be used to improve the ability of medical staff to identify the aEEG waveforms; 2) Masimo Rainbow SET pulse oximetry monitoring, monitor the SpO2/PI/PR change in a non-invasive and continuous manner, effectively eliminate the exercise interference, and improve the measurement performance under low perfusion and body motion.
  • Rechargeable battery Equipped with a rechargeable lithium-ion battery to support 2h independent working time, which is convenient for transfer of patient.
  • Real-time detection of electrode impedance Provide the function of real-time detection of electrode impedance to ensure the validity of the detection information.
  • Stable integrated medical trolley Compliant with the allowable load in IEC60601-1, more stable than ordinary trolleys, easy to move, and special for bedside monitoring.
     
  • Epilepsy rapid identification and application 1) Envelope trend chart (ENVELOPE) is used to represent the change in the EEG amplitude, which can better eliminate the artifacts caused by interference and identify epileptic seizure events more accurately; 2) TP (total power), also known as total energy, reflects the change in the EEG amplitude and has high sensitivity and low specificity for clinically detecting epileptic seizures.
 
  • Medical all-in-one machine - "intuitive display in the multi-trend chart" 1) Complies with the EU CE-related: EN60601-1-2: 2015 and EN60601-1: 2006 standards, with better hardware security, stability, durability, and anti-interference; 2) Equipped with a 19-inch color touch medical-grade display screen, displays each trend chart and corresponding values clearly and intuitively; 3) Provides a variety of trend chart displays and real-time EEG displays to help clinicians interpret data in time and ensure the accuracy of clinical diagnosis.
 
  • Signal amplifier - "multi-channel signal acquisition" 1) Standard 4 channels and optional 8/12 channels, with impedance selection button, built-in SpO2 input channel, less interference from the environment, and more stable signal acquisition; 2) With strong anti-interference performance, it can also record high-quality electrophysiological signals in the complex NICU and operating room environments and during the transfer process.
 
  • High-definition night-vision video monitoring 1) The optional high-definition camera with night vision function supports horizontal and vertical rotation, and the illumination distance can be up to 20m; 2) The physical movement of patients can be monitored in a real-time manner through the LCD screen, eliminate artifacts caused by various interference, and detects EEG signals accurately.
https://youtu.be/JwSJvUVJrxo?si=6QkpitWAwvZZSwOM  
Description
The Dolphin/XF is a new breakthrough development in TCD robotics. It is designed to assist the user in quickly and automatically insonating and monitoring cerebral blood flow.
Features

Comfortable Headset

The unique Dolphin/XF robot fits the patient’s head with a soft and comfortable dedicated monitoring headset. The patient’s posture is of no limitation, and thus the patient can lay down, be seated, or stand up during the measurements with the robot without any discomfort or preventing factors in the headset.

Ultra Fast Scanning

Use the Fast Scan mode for rapid scanning within seconds. Or use the High-Resolution Scan option for a more detailed robotic search through the temporal or suboccipital windows. This latter option generates a “heat map” as a function of insonated depth, showing all of the identified blood flow velocities flowing either towards the probe or away from the probe. https://youtu.be/QsaSaUbh7as?si=Vky2fSg6Mc3Ft_ob

Ideal Monitoring Solution

The Dolphin/XF TCD robot is ideal for settings where short or long-term monitoring is required. This includes applications in:
  • Anesthesia and the Operating Room (OR),
  • HITS detection for longer-term applications, 
  • Specialty Test protocols such as Vasomotor Reactivity (VMR), Breath Holding or PFO testing for short term monitoring, 
  • Use in the ICU, or 
  • With SAH or Stroke patients where cerebral blood flow monitoring is of particular importance. 
https://youtu.be/b6dDU1mGQ8Q?si=md0GOLuI1mUt6ouv
The Brainsway Deep TMS H7 RCT Coil is a flexible coil used in transcranial magnetic stimulation (TMS) to treat obsessive-compulsive disorder (OCD) and other neuropsychiatric conditions:
  • What it does
    The H7 Coil stimulates the medial prefrontal cortex and the anterior cingulate cortex of the brain. TMS uses magnetic pulses to create an electrical current in the brain's neuronal tissue. 
  • How it's used
    The H7 Coil is integrated into a cooled, cushioned helmet that allows the patient to move around during treatment. A sham coil is also included so that the patient and operator can't tell the difference between the treatment and sham coils. 
  • What it's used for
    The H7 Coil is FDA-cleared for OCD, but it's also been shown to be effective in treating other conditions, including addiction, major depressive disorder, and autism spectrum disorder. 
  • How it works
    The H7 Coil is designed to regulate the CSTC circuit, which is thought to be involved in impulsive behavior. 
  • Safety
    A 2023 paper that analyzed adverse events from five large, randomized controlled trials found that most adverse events were transient and resolved within days.
Features
  • Stimulates specific brain regions
    The H7 Coil targets the anterior cingulate cortex and the medial prefrontal cortex. 
  • Flexible windings
    The H7 Coil's flexible windings conform to the shape of the patient's head. 
  • FDA-cleared for OCD
    The H7 Coil is FDA-cleared for treating obsessive-compulsive disorder (OCD). 
  • Demonstrated efficacy
    The H7 Coil has been shown to be effective in treating OCD patients with varying degrees of severity and comorbidities. 
  • Integrated sham coil
    The helmet includes a sham coil that makes the treatment appear, sound, and feel the same to the patient and operator.

Click here to download Brochure

https://youtu.be/YSWvhSIS1ho?si=ZVl2aB_GXgSRotbP
Features of Falcon Physiologic Machine

Segmental Blood Pressures

Measure lower extremity pressures easily with 10 color-coded channels and a variety of Doppler probes and PPG sensors. Complete the vascular diagnosis with supportive stress testing. Falcon is considered by many the best segmental pressure machine with numerous advanced features such as 10 simultaneous PVR measurements and limitless post-processing capabilities.

Fast and Accurate ABI & TBI

Quickly measure ABI and TBI with either Doppler or Photoplethysmography (PPG). With the Falcon ABI and TBI machine, all measurements are saved automatically and sent directly to the dedicated interactive summary screen.

High Quality Doppler Probes

In addition, to the 4 MHz and 8 MHz probes for standard use, the advanced Falcon Doppler machine offers a unique 10 MHz probe, which is designed to measure particularly small peripheral blood vessels. All Falcon Doppler probes produce complete high-resolution Doppler spectral analysis with the aid of the Falcon vascular software and algorithms.

State-of-the-Art PPG Sensors

Falcon offers a wide selection of Photoplethysmography sensors.   The 5 completely independent PPG ports allow simultaneous fingers/toes measurements, which is especially useful for Raynaud’s diagnosis along with a an integrated temperature sensor.  Fingerclip and Toeclip PPG sensors are recommended for routine examinations. The Disc PPG sensors are particularly useful for Venous Reflux testing and are supplied with dedicated adhesive stickers.

Highest Durability and Reliability

The Falcon is the most reliable peripheral vascular machine in the market.  Thanks to the high quality Doppler probes, 10 Independent Pressure Channels (IPU Technology) and 5 PPG Ports, the Falcon design significantly reduces any down-time. Falcon is in distributed worldwide for over 10 years with the lowest fail rate in the market!

Complete Network Connectivity

The Falcon unmatched connectivity capabilities are a paradise to hospital IT personnel and EMR and PACS managers. The advanced networking abilities allow a plug-and-play operation to easily configure connectivity with automated DICOM Worklist & Storage, Structured Report, and HL7. With unlimited Review Stations, measurements can be reanalyzed and interpreted from the comfort of your office. Final reporting can also be configured and finalized from any location.

Simplify Your Workflow

The Falcon vascular diagnosis device has the ability to configure as many dedicated examination protocols that allow to save time and optimize the patient vascular diagnosis​. Enjoy the user-friendly protocol builder to configure your workflow according to your needs!​

Ease of Use

Minimal learning curve thanks to user-friendly software with a large touch-screen display. A selection of wired and wireless remote control​ and footswitch allows keeping your focus on the patient rather than on the physiologic vascular equipment.

Dedicated Specialty Tests

The Falcon is the complete vascular physiologic assessment machine with dedicated protocols that guide you through step-by-step diagnostic measurements of specific vascular conditions.  The dedicated diagnosis protocols include measurements of Thoracic Outlet Syndrome (TOS), diagnosis of Raynaud’s Phenomenon, evaluation of Penile Function or Erectile Dysfunction, assessment of Allen’s Test (or Palmar Arch Test), measurements of Venous Reflux and Venous Capacitance and Outflow, Pulse Wave Velocity, and more.

Advanced Reporting

The famous Falcon user-friendly report builder tool allows you to design your own report layout easily. Then, add your institute/clinic logo and details to create a detailed and impressive diagnosis report that meets your institute standards. Save a lot of time by building your report with preconfigured interpretation templates.

Advanced Research Options

The Falcon vascular research machine is famous for its built-in statistics tool with on-screen graphs, segments filtering, and Excel tool, which are all designed to simplify the work of vascular and physiological researchers. Export to PDF, Excel, Word, JPEG, VSX, Video clips, and more to support your vascular research and teaching needs, as well as support your clinical vascular publications.
WeightN/AN/AN/AN/AN/AN/A
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • Rating
  • Price
  • Description
Click outside to hide the comparison bar
Compare