Technical Details
Environmental temperature range: | 5°C~ 40°C |
Relative moisture range: | ≤80% |
Atmosphere pressure range: | 86.0 Kpa ~ 106.0 Kpa |
Working modes:
Pure cut: | 5w ~ 100w (Load:300Ω) |
Blend cut: | 5w ~ 50w (Load:300Ω) |
Forced coagulation: | 5w ~ 80w (Load:500Ω) |
Soft coagulation: | 5w ~ 50w (Load:500Ω) |
Technology data:
Voltage: | 230V±10V, 50Hz |
Working frequency: | 330KHz ~ 460KHz |
Leakage currents to ground: | Less than 0.5mA |
Leakage currents to patient: | Less than 0.01mA |
Quick Comparison
Settings | OBS-100A Monopolar Electrosurgical Unit remove | Disposable LOOP Tungsten Electrode remove | Disposable ECG Monitoring Electrode remove | Disposable Subdermal Needle Electrodes remove | Disposable Electrosurgical Pencil remove | Electrosurgical Forceps remove | ||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Name | OBS-100A Monopolar Electrosurgical Unit remove | Disposable LOOP Tungsten Electrode remove | Disposable ECG Monitoring Electrode remove | Disposable Subdermal Needle Electrodes remove | Disposable Electrosurgical Pencil remove | Electrosurgical Forceps remove | ||||||||||||||||||||||
Image | ![]() | ![]() | ![]() | ![]() | ![]() | ![]() | ||||||||||||||||||||||
SKU | SF1033560130165-7 | SF1033560130165-14 | SF1033560130165-24 | SF1033560130165-25 | SF1033560130165-10 | SF1033560130165-19 | ||||||||||||||||||||||
Rating | ||||||||||||||||||||||||||||
Price |
|
|
|
|
|
| ||||||||||||||||||||||
Stock | ||||||||||||||||||||||||||||
Availability | ||||||||||||||||||||||||||||
Add to cart | ||||||||||||||||||||||||||||
Description | Shipped From Abroad
Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| Shipped From Abroad
Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| Shipped From Abroad
Disposable ECG Electrodes consist of snap set, conductive gel, backing material with medical adhesive, and release film. OBS Disposable ECG Electrodes model 301 are Non-woven, Micropore fabric backing Electrodes . These electrodes are applied by or on the order of a physician on a patient’s skin, the model 301 is fit for the general electrocardiographic application of both adults and children.
Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| Shipped From Abroad
Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| Shipped From Abroad
A Disposable Electrosurgical Pencil is a single-use tool used in surgery to cut and cauterize tissue. It features an ergonomic design for easy handling and comes with various electrode tips to suit different surgical needs. It ensures patient safety by being sterile and disposable.
Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| Shipped From Abroad
Mainly used for bipolar subtle coagulation in microsurgery, neurosurgery, spine surgery, and medical cosmetology
Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| ||||||||||||||||||||||
Content |
Features1. Portable and affordable 2. Suitable for general surgery and veterinaryTechnical Details
|
Features1. Stainless steel & non-stick finish 2. The hexagonal connection ring fits the pencil locking design. 3. Different shapes fitting for different surgeries | Indications for Use:
Disposable ECG Electrodes are pre-gelled, non-sterile, single use disposable electrocardiographic electrodes which are intended for use as an accessory to ECG equipment for ECG monitoring , diagnostic procedures and can used for stress test & holter. Instruction for Use:1. Clean the skin area where the electrode will stick on. Make sure the skin area for sticking is intact (uninjured). 2. Connect the leadwire with the electrode. Make sure it is fastened and in good contact. 3. Tear off the release film from the bottom (the part away from metal stud) of electrode. 4. Press lightly when stick the electrodes to the skin and make sure the conductive gel and adhesive backing stick on the skin tightly. Caution
|
FeaturesHandswitching pencils are available with either push-button or rocker switch controls to accommodate the surgeon's preference. Switches have a high level of tactile feedback - surgeons can hear and feel the switch engage, preventing accidental activation of the device.
|
Features
| |||||||||||||||||||||||
Weight | N/A | N/A | N/A | N/A | N/A | N/A | ||||||||||||||||||||||
Dimensions | N/A | N/A | N/A | N/A | N/A | N/A | ||||||||||||||||||||||
Additional information |
Reviews
There are no reviews yet.