Description | Shipped from Abroad
SFX-91D is an efficient and convenient digital binocular stereomicroscope equipped with turnable objective with 3 magnifications (1x-2x-4x), precision fixed arm with handle, and incredibly bright and uniform illumination (transmitted and incident), settable through the exclusive touch control.
Delivery & Availability:
Typically 21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | In stock
The Discover Cup is an all-in-one drug of abuse test cup. The strips are self-contained and the entire cup is tamper resistant.
Delivery & Availability:
Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | Shipped from Abroad
The skyla HB1 Clinical Chemistry Analyzer provides clinical testing laboratories of medical facilities and clinics with an in-vitro clinical chemistry diagnostic tool that is compact, portable, and reports rapid results. The portable design of the clinical chemistry analyzer utilizes precision photometric measurement technology, combined with the single-use disposable reagent discs. The reagent disc contains a set of dry assay reagents that are used in the quantitative testing of various biomarkers in the blood sample.
Delivery & Availability:
Typically 14 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | In stock
- Made of high quality PP material with good transparency.
- Applied for Gilson/Finland/Eppendorf Pipettors.
- Carefully inspect of raw material and manufactured under strict process check, all tips are with excellent accuracy and precison.
- Special siliconizing on the inner surface ensure no liquid adhesion and accurate sample transfer.
- Standard tips and filter tips can be autoclaved, high temperature sterilization acceptable.
Delivery & Availability:
Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | In Stock
Twenty Five (25) Test Strip per Pack
Delivery & Availability:
Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | Shipped From Aboard
The advanced B111 Bilirubinmeter provides fast, accurate results for Total bilirubin level in neonates with only 40μl serum or plasma sample. It determines total bilirubin by dual wavelength photometric analysis. Suited for pediatric setups, small workload labs & hospitals because of its compact and portable design. Advanced, benchtop and precise instrument for measuring Total Bilirubin.
Delivery & Availability:
Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. |
Content | Digital binocular stereomicroscope equipped with turnable objective with 3 magnifications (1x-2x-4x), precision fixed arm with handle, and incredibly bright and uniform illumination (transmitted and incident), settable through the exclusive touch control. Powered by rechargeable batteries.
Head
Binocular, 45° inclined, 3 MP integrated camera
Eyepieces
WF10x/20mm
Objective
1x – 2x – 4x selectable
Working Distance
60 mm
Stand
Precision fixed with focus and handle
Illumination
Incident: 1 W LED Transmitted: 1 W LED
Touch brightness control, rechargeable batteries
Specifications:
Observation Method - Transmitted Light |
|
Observation Method - Incident Light |
|
|
|
Type; |
Binocular |
Construction material: |
Aluminum & Plastic molds / Aluminum gears |
Inclination: |
45° |
360° rotating: |
Yes |
Interpupillary distance(mm): |
53-75 |
Dioptric adjustment: |
On both tubes |
Fixing screw for eyepieces: |
Yes |
Tube inner diameter (mm): |
30.5 |
|
|
Field number (mm): |
20 |
Magnification: |
10x |
Micrometric scale: |
As optional |
Diameter of micrometer glass (mm): |
20 |
Rubber cup: |
Yes |
|
|
Optical system: |
Greenough |
Anti-fungus treatment: |
Yes |
Objective Type: |
Achromatic |
Working distance (mm); |
60 |
Standard magnifications: |
10x, 20x, 40x (rotating turret) |
|
|
Type: |
Coarse |
Coarse total travel (mm): |
41 |
Adjustable tension: |
Yes |
|
|
Type: |
Precision fixed arm |
Handle: |
Yes |
|
|
Frosted diffusion plate for transmitted ill.: |
Yes, diameter 60 mm |
Black/white contrast plate for incident ill.: |
Yes, diameter 60 mm |
Specimen clips: |
Yes |
|
|
Type: |
LED |
Light source power (W): |
1 |
Brightness control: |
Touch Panel |
Lifetime (hours): |
> 65,000 |
Temperature (K): |
6,300 |
Max. required power (W): |
1.5 |
|
|
Type: |
LED |
Light source power (W); |
1 |
Brightness control: |
Touch Panel |
Lifetime (hours): |
> 65,000 |
Temperature (K): |
6,300 |
Max. required power (W): |
1.5 |
|
Power Supply for Illumination |
|
Type: |
External |
Microscope connector: |
Jack, 2.1 mm |
Power plug type: |
Multi-plug (EU, UK, US) |
Input voltage: |
100/240 Vac, 50/60 Hz |
Output voltage: |
5 Vdc 500 mA |
LED indicator: |
Yes |
Rechargeable batteries: |
Yes |
Battery type: |
Ni-MH (3x, AA size) |
Working time of batteries (hours): |
8 |
Charging time of batteries (hours): |
8 |
Accessories Included |
Dust cover: |
Yes |
Tension adjustment tool: |
Yes |
User Manual: |
Digital version (downloadable) |
Calibration slide: |
Yes |
Additional Information |
Maximum sample height (mm): 35 |
Product Dimensions |
Total height (mm): |
288 |
Base height (mm): |
45 |
Base width (mm): |
183 |
Base depth (mm): |
205 |
Product Weight |
(kg): |
2.5 |
Digital Head |
Resolution (MP): |
3 |
Sensor type: |
APTINA CMOS |
Sensor size: |
1/2" |
Sensor aspect ratio: |
4/3 |
Full image size: |
2040x1528 |
Pixel size (μm): |
3.2x3.2 |
Frame rate:
|
13 fps (2040x1528),
40 fps (1016x760),
79 fps (632x472) |
S/N ratio (dB): |
43 |
Dynamic range (dB): |
54 |
Sensitivity (V/lux*s @550nm): |
1 |
Exposure time (s): |
0,6 - 1/1000 |
USB type: |
2.0 |
System requirements: |
Win 7 / Win 8 / Win 10 (32/64 bit) |
Software: |
OPTIKA Vision Lite |
|
FDA 510K & CLIA Waived
99% Accurate
Results in as little as 1 minute
24 Month Shelf Life from Date of Manufacture
Secure, seal and send to lab for confirmation
Built in temperature strip
Available to test up to 14 substances
Adulterants available
| Skyla HB1 Clinical Chemistry Analyzer utilizes precision photometric measurement technology, combined with the single-use disposable reagent discs. The reagent disc contains a set of dry assay reagents that are used in the quantitative testing of various biomarkers in the blood sample. HB1 provides clinical testing laboratories of medical facilities and clinics with an in-vitro clinical chemistry diagnostic tool that is compact, portable, and reports rapid results. Only needs 200µl of blood (whole blood, serum or plasma is accepted.) and no sample preparation is required. All steps are designed automatically from checking the validity of reagent discs and cartridges to printing the results. Over 30 test parameters are allowed with fast analysis and results in 15 minutes. Internal Quality Control (IQC) with self-calibration of optical system, chemicals stability and interference alerts functions monitor and ensure the results with high accuracy.
Available Test Panels
- Renal Function - BUN, CREA eGFR
- Liver Function - ALB, TP, ALP, ALT, AST, TBIL, DBIL, GGT, LDH A/G#, GLOB#, IBIL
- Lipid Metabolism - TG, TC, HDL LDL#, VLDL
- Pancreatitis Markers - AMY, LIPA
- Carbohydrate Metabolism and Others - GLU , CPK, UA, LAC
- Inflammatory Markers - CRP
- Electrolyte - Na, K, Cl, Ca, PHOS, Mg, tCO2
SPECIFICATION
Principle
- Colormetric System : LEDs 340nm~940nm wavelength
Sample & Panel
- Test Profiles : Panels
- Measurement Time - Panel: up to 15 tests/ 15 min
- Sample Type & Volume : 200 μl whole blood (PCV<60%), plasma, serum
Device
- User Interface : 5 inch color LCD touch screen
- Internal Memory : Store up to 50,000 analysis results
- Printer : Built in thermal printer or external USB printer
(PCL 3GUI)
- USB Socket : USB type A (Host) for external USB Printer, USB
flash drive (FAT) or external barcode scanner
- Data transmission to PC : RS232 serial port or RJ45 (LAN)
- Dimensions : 233 (W) X 285 (D) X 300 (H) mm
- Weight : 5.5 kg
Operating Condition
- Temperature / Humidity : 10 to 32˚C / 5 to 90 %
|
- Made of high quality PP material with good transparency.
- Applied for Gilson/Finland/Eppendorf Pipettors.
- Carefully inspect of raw material and manufactured under strict process check, all tips are with excellent accuracy and precison.
- Special siliconizing on the inner surface ensure no liquid adhesion and accurate sample transfer.
- Standard tips and filter tips can be autoclaved, high temperature sterilization acceptable.
Classification: PIPETTE
Brand Name: Vchanslab,Yingmed,OEM
Model Number: YM-K7028
Place of Origin: China
Product name: Pipette Tips
Material: Polypropylene
Certificate: CE/ISO13485/FDA
Color: Natural, Blue, Yellow
Application: Laboratory, Teaching, Hospital | Twenty Five (25) Test Strip per Pack | The advanced B111 Bilirubinmeter provides fast, accurate results for Total bilirubin level in neonates with only 40μl serum or plasma sample. It determines total bilirubin by dual wavelength photometric
analysis. Suited for pediatric setups, small workload labs & hospitals because of its compact and portable design. Advanced, benchtop and precise instrument for measuring Total Bilirubin.
Feature
- Auto zero function: Manual blanking not required
- Dual wavelength measurement system:
- 2 wave lengths 455nm and 575nm
- Plays major role to remove the interference caused due to Hemolysis & turbidity of sample
- LED Light source:
- LED does not require replacement as it lasts longer
- As compared to Lamp, LED are more suitable as there is no intensity fluctuations
- No warm up time required.
- Flexible unit selection:
- Two units either mg/dl or umol/L are selectable, ease of reporting
- Compact slot for Capillary:
- Accuracy of results are directly related to proper alignment of Capillary
- B-111 has the easiest mode to ensure precise values
- Data transfer:
- External device can be connected to instrument through RS232 por
- USB port
Technical Specification
- Light source - LED
- Wavelength - 455nm and 575nm
- Net weight - 1kg
- Measuring range - 0-30 mg/dl , 510 umol/L
- Display - 16×2 LCD module with backlight
- Auto calibration - Yes
- Sample type - Serum or plasma
- Sample volume - 40-80μL
- Test time - <5sec
- Units - mg/dl or umol/L
- Dimensions - 150 (W) × 115 (H) × 190 (D) mm
- Interface - RS232
- Reading cuvette - Heparinized micro capillary holder
- Storage temperature - 15-40°c
- Power supply - DC 9V(DC adapter)
- Power consumption - <2W
|
Reviews
There are no reviews yet.