Overhead stirrer PE-8310 (rack PE-2730)

$0.00

Shipped From Abroad

Purpose:

PE-8310 stirrer is intended for stirring a fluid of various viscosity, liquids and solid bodies, liquids and bulk solids.

Delivery & Availability:
Typically 14-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.

SF10335601084
Brands:: ECROSKHIM

Description

Purpose:

PE-8310 stirrer is intended for stirring a fluid of various viscosity, liquids and solid bodies, liquids and bulk solids.

Advantages:

The Overhead Stirrer is fitted with built-in control unit with LCD, memorized settings function, motor protection against overload and overheating.
 

Suitable for stirring:
– aqueous solution – 1 mPa/s

– liquid adhesive and fluid paint – 70-500 mPa/s
– many kinds of paint and enamel – 500-3000 mPa/s с
– color concentrate – 3000-30000 mPa/s
– thick glue (for parquet or linoleum) – 30000-50000 mPa/s
 

Technical specifications:
– Max. viscosity of fluid, mPa/s – 50000

– Volume of stirred sample, L – 0.25 – 20.0
– Rotation speed of stirrer shaft, rpm – 100 to 3000
– Max. rotational moment, Ncm – 60
– Max. stirrer shaft diameter, mm – 8(10)
– Max. stirrer shaft length – unlimited
– Rotational speed accuracy of stirrer, rpm – ±20 об./мин
– Max. power consumption, W – 100
– Supply voltage (50 Hz),V – 220 ± 10
– Dimensions of the unit (stand rod included), mm – 420х380х800
– Weight, kg – 12

Scope of supply:
1. Overhead stirrer – 1 pc

2. PE-2730 stand rod – 1 pc
3. Holding ring – 1 pc
4. Clamp for fastening the stirrer on the stand rod – 1 pc
5. Clamp for fastening the holding ring on the stand rod – 1 pc
6. Two-finger grip (for flasks) – 2 pcs
7. Three-finger grips (for flasks) – 2 pcs
8. Clamp for grips – 4 pcs

Reviews

There are no reviews yet.

Be the first to review “Overhead stirrer PE-8310 (rack PE-2730)”

Your email address will not be published. Required fields are marked *

Quick Comparison

Overhead stirrer PE-8310 (rack PE-2730) removeEppendorf Pipette Tip 20ul Per Pack removeDiscover 14 Panel Cup with Adulterants Per Pack removePlastic Urine Container Per Pack removeNikon SMZ745 Stereoscopic Microscope removeiSED Fully Automated ESR Analyzer remove
NameOverhead stirrer PE-8310 (rack PE-2730) removeEppendorf Pipette Tip 20ul Per Pack removeDiscover 14 Panel Cup with Adulterants Per Pack removePlastic Urine Container Per Pack removeNikon SMZ745 Stereoscopic Microscope removeiSED Fully Automated ESR Analyzer remove
ImageEppendorf Pipette Tip 20ul Per PackDrug Test CupNikon SMZ745 Stereoscopic Microscope
SKUSF10335601084SF1033560084-136SF1033560084-28SF1033560084-106SF1033560084-49SF1033560084-129
Rating
Price

$0.00

$0.00

$0.00

$8.20

$0.00

$0.00

Stock
Availability
Add to cart

DescriptionShipped From Abroad

Purpose:

PE-8310 stirrer is intended for stirring a fluid of various viscosity, liquids and solid bodies, liquids and bulk solids.

Delivery & Availability: Typically 14-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock
  • Made of high quality PP material with good transparency.
  • Applied for Gilson/Finland/Eppendorf Pipettors.
  • Carefully inspect of raw material and manufactured under strict process check, all tips are with excellent accuracy and precison.
  • Special siliconizing on the inner surface ensure no liquid adhesion and accurate sample transfer.
  • Standard tips and filter tips can be autoclaved, high temperature sterilization acceptable.
Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock
The Discover Cup is an all-in-one drug of abuse test cup. The strips are self contained and the entire cup is tamper resistant. Delivery & Availability:
Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock
  • Total Volume: 60mL.
  • Specimen Container, Leak-proof, Ideal for Pathology/Histology/Cytology reagent pre-filling sample preparation.
  • Made of premium PP material, it is durable for usage.
  • Some measurements can be used to not only use urine samples, it can also be used for other liquids.
Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock Nikon SMZ745 Stereoscopic Microscope: Featuring a zoom magnification of 7.5X and a long working distance of 115mm, Nikon SMZ745 microscopes are well suited for both industrial and biomedical applications. The adoption of a new total reflection prism produces brighter images with higher contrast, and the anti-mold design allows the microscope to be used in environments where the temperature and humidity are high. The SMZ-745T trinocular model comes equipped with a microscope camera port and a built-in 0.55x c-mount adapter, permitting direct mounting of Nikon DS Series Digital Cameras. Delivery & Availability: Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.In stock
The technical innovation of the iSED® fully-automated ESR analyzer consists of directly measuring the intensity of the red cell aggregation which is responsible for Erythrocyte Sedimentation Rate (ESR). Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Content

Purpose:

PE-8310 stirrer is intended for stirring a fluid of various viscosity, liquids and solid bodies, liquids and bulk solids.

Advantages:

The Overhead Stirrer is fitted with built-in control unit with LCD, memorized settings function, motor protection against overload and overheating.   Suitable for stirring: - aqueous solution - 1 mPa/s - liquid adhesive and fluid paint - 70-500 mPa/s - many kinds of paint and enamel - 500-3000 mPa/s с - color concentrate - 3000-30000 mPa/s - thick glue (for parquet or linoleum) - 30000-50000 mPa/s   Technical specifications: - Max. viscosity of fluid, mPa/s - 50000 - Volume of stirred sample, L - 0.25 – 20.0 - Rotation speed of stirrer shaft, rpm - 100 to 3000 - Max. rotational moment, Ncm - 60 - Max. stirrer shaft diameter, mm - 8(10) - Max. stirrer shaft length - unlimited - Rotational speed accuracy of stirrer, rpm - ±20 об./мин - Max. power consumption, W - 100 - Supply voltage (50 Hz),V - 220 ± 10 - Dimensions of the unit (stand rod included), mm - 420х380х800 - Weight, kg – 12 Scope of supply: 1. Overhead stirrer - 1 pc 2. PE-2730 stand rod - 1 pc 3. Holding ring - 1 pc 4. Clamp for fastening the stirrer on the stand rod – 1 pc 5. Clamp for fastening the holding ring on the stand rod – 1 pc 6. Two-finger grip (for flasks) – 2 pcs 7. Three-finger grips (for flasks) – 2 pcs 8. Clamp for grips - 4 pcs
  • Made of high quality PP material with good transparency.
  • Applied for Gilson/Finland/Eppendorf Pipettors.
  • Carefully inspect of raw material and manufactured under strict process check, all tips are with excellent accuracy and precison.
  • Special siliconizing on the inner surface ensure no liquid adhesion and accurate sample transfer.
  • Standard tips and filter tips can be autoclaved, high temperature sterilization acceptable.
  Classification: PIPETTE Brand Name: Vchanslab,Yingmed,OEM Model Number: YM-K7028 Place of Origin: China Product name: Pipette Tips Material: Polypropylene Certificate: CE/ISO13485/FDA Color: Natural, Blue, Yellow Application: Laboratory, Teaching, Hospital
All-in-One Design
FDA 510(K) & CLIA Waived Up to 99% accuracy rate Results in as little as 1 minute 24 Month Shelf Life from Date of Manufacture Secure, seal and send to lab for confirmation Built in temperature strip Available to test up to 17 substances with adulterants or 18 without adulterants Adulterants available
 
 
  • Total Volume: 60mL.
  • Specimen Container, Leak-proof, Ideal for Pathology/Histology/Cytology reagent pre-filling sample preparation.
  • Made of premium PP material, it is durable for usage.
  • Some measurements can be used to not only use urine samples, it can also be used for other liquids.
Nikon SMZ745 Stereoscopic Microscope: Featuring a zoom magnification of 7.5X and a long working distance of 115mm, Nikon SMZ745 microscopes are well suited for both industrial and biomedical applications. The adoption of a new total reflection prism produces brighter images with higher contrast, and the anti-mold design allows the microscope to be used in environments where the temperature and humidity are high. The SMZ-745 trinocular model comes equipped with a microscope camera port and a built-in 0.55x c-mount adapter, permitting direct mounting of Nikon DS Series Digital Cameras. Features:
  • Trinocular optical head for monitoring and digital imaging
  • Impressive 7.5x zoom magnification
  • 115 mm working distance
  • Maximum ergonomics
  • Rugged, durable design suits a variety of applications and environments
Technical Specifications:
Optical system Greenough optical system
Total magnification 3.35-300x, depending on eyepiece and auxiliary objective used
Vertical tube Built-in C-mount 0.55x magnification lens (F.N. 11), compatible with 2/3 in. or smaller CCD
Eyepiece tube Fixed type
Eyepiece inclination 45°
Interpupillary distance adjustment 52-75 mm
Eyepieces (with diopter adjustment) C-W 10xB (F.N. 22), C-W 15x (F.N. 16), C-W 20x (F.N. 12.5), C-W 30x (F.N. 7)
Zooming ratio 7.5:1 (approx.)
Zooming range 0.67-5x
Auxiliary objectives G-AL 0.5x (W.D. 211 mm), G-AL 0.7x (W.D. 150 mm), G-AL 1.5x (W.D. 61 mm), G-AL 2x (W.D. 43.5 mm)
Working distance 115 mm
     
 
 
The technical innovation of the iSED® fully-automated ESR analyzer consists of directly measuring the intensity of the red cell aggregation which is responsible for Erythrocyte Sedimentation Rate (ESR). Unlike traditional ESR methodologies that measure the aggregation of the red blood cells indirectly, the iSED measures it directly and expresses the values in mm/hr. Features:
  • Results in 20 Seconds

  • 100µL sample drawn directly from primary EDTA tube

  • Fully automated, walk-away operation

  • Random access

  • Positive patient identification via internal barcode reader

  • Compatible with pediatric tube

     
Technical Specifications: 
Principle of Measure: Photometrical
Results: “Printed mm/hr, Range from 1-130 mm/hr”
Sample Requirements: 500uL whole blood, collected in EDTA anti-coagulant tested 24 hours from venipuncture at room temperature or refrigerated.
Tube Requirements: 13 x 75 mm, pierceable capped tube
Quality Control: Barcoded Seditrol® QC
Barcode Reader: Internal
Printer: Internal
Interface Specifications: serial RS232 port for LIS connection
Weight: 14 kg
Dimensions (H x W x D): 36 x 27 x 34 (cm) /14.3 x 10.5 x13.4 (in)
Voltage: 100-240VAC
Frequency Range: 50-60 Hz
Power: 160W
Click Here To Download Catalogue
WeightN/AN/AN/AN/AN/AN/A
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • Rating
  • Price
  • Description
Click outside to hide the comparison bar
Compare