PCR cabinet are designed to reduce the risk of contamination while performing Polymerase Chain Reaction (PCR) experiments, it direct HEPA-filtered air downward over the work area to provide ISO Class 5 (formerly Class 100) conditions and protect your work during preparatory procedures and amplifications.
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Perforations at the back wall of the work zone which are designed to eliminate air turbulence and the possibility of dead air corners in the work zone.
Variable digital timer that provides UV light exposure continuously or in user-selected increments of 15, 30, 60,120 till 999 minutes to deactivate DNA and RNA contaminants.
Intuitive and easy-to-use microprocessor controller with LCD display, graphical and digital display of all the operating status of each function, such as filter life, UV life etc.
Ergonomic control panel location, centered and angled down for an easy reach & viewing.
The non-direct light source design can effectively relieve the operator’s visual fatigue under the condition of ensuring the illumination.
Different sizes available from 2 feet to 6 feet, benchtop use or mounted on a mobile base.
Brushed stainless steel work surface is for easy cleaning.
Safety Performance:
Audio and visual alarm on filter life, UV life etc.
Front sliding sash interlock with fan and UV lamp.
Front sash and side windows are made of UV-resistant tempered glass.
The host and sockets have independent capacitors to prevent current overload.
Humanized design:
Standard shelves with IV bar.
Memory function in case of power-failure.
HEPA filter and UV life indicators facilitate a timely replacem ent plan.
Two sides glass windows installed for easy experiment observation.
Easy-to-change pre-filter installed could extend the HEPA filter’s lifetime.
Equipped with temperature sensor to show the real temperature during operation.
Waterproof socket provide convenience for small instruments to be used in the operating area.
PCR Cabinet Specifications:
Model
PCR-800
PCR-1100
PCR-1300
PCR-1600
PCR-1900
External Size (WxDxH)(mm)
710x680x1050 (Without Base Stand)
710x680x1670 (With Base Stand)
1050x710x1850
1320x710x1850
1625x710x1850
1930x710x1850
Internal Size (WxDxH)(mm)
610x590x625
950x615x625
1220x615x625
1525x615x625
1830x615x625
Work Surface Height
750mm
Control System
Microprocessor controller with LCD display, graphical and digital display of the operating status
Audio and visual alarm on filter and UV changing
Front sliding sash interlock with fan and UV lamp
HEPA filter and UV life indicators facilitate a timely replacement plan
Air Filtration System
Cleanness
ISO Class 5 (Formerly Class 100)
Airflow Velocity
0.2~0.5 m/s, speed adjustable
HEPA Filter
1 pcs, efficiency > 99.995% at particle size of 0.3 μm
Pre-Filter
1 pcs, made of washable polyester fiber
Partial Air Circulation
Perforations at the back wall of the work zone which are designed to eliminate air turbulence and the possibility of dead air corners in the work zone.
Sound Emission
≤62dB(A)
Illuminating Lamp
LED Type, Illumination ≥900Lx
UV Decontamination System
1. With timing function from 0 to 999 minutes
2. Interlock with front sliding sash.
3. Emission of 253.7 nanometers for best sterilization effect.
10Wx2
20Wx1
30Wx1
30Wx1
20Wx2
Power Consumption
149W
155W
285W
285W
300W
External devices connected via power sockets are not included
Cabinet Structure
Main Body: Electro-Galvanized steel with antimicrobial powder coating
Work Zone: 304 Stainless steel, an angled front, rounded work surface front edge
Side Windows: 5 mm UV resistant tempered glass
Power Supply
AC220V ±10%, 50/60Hz, 1P
Standard Accessories
LED lamp; UV lampx2; Waterproof socket×2 (only 1 for PCR-800); Shelves with IV bar
Optional Accessories
Base stand(only PCR-800); Water tap, Gas tap, Height adjustable base stand
Net Weight
80kg(Without
base stand), 130kg (With base stand)
–
Gross Weight
115kg (Without base stand), 165kg (With base stand)
Shipped From Abroad
PCR cabinet are designed to reduce the risk of contamination while performing Polymerase Chain Reaction (PCR) experiments, it direct HEPA-filtered air downward over the work area to provide ISO Class 5 (formerly Class 100) conditions and protect your work during preparatory procedures and amplifications.
Delivery & Availability:Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock
The coagulometer, LabPad® INR, measures blood coagulation time thanks to a patented optical technology. This portable In-Vitro Diagnostics (IVD) device works with the Tsmart® INR single-use microcuvettes.
Delivery & Availability:
Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock
This Automatic Pipette will help you get your lab up and running in no time—at a great price!
Delivery & Availability:
Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Aboard
The advanced B111 Bilirubinmeter provides fast, accurate results for Total bilirubin level in neonates with only 40μl serum or plasma sample. It determines total bilirubin by dual wavelength photometric analysis. Suited for pediatric setups, small workload labs & hospitals because of its compact and portable design. Advanced, benchtop and precise instrument for measuring Total Bilirubin.
Delivery & Availability:
Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad
Electrolyte Analyzer ERMA EL-120 is ideal for medium to high volume Laboratories and Hospitals . It offers reliable, automated samples handling and work flow offences . It also allows measurement of specific ions, accurately and precisely . This supports fast diagnosis of critically ill patients and reduces the risks of patient discomfort associated with repeated sampling Precise & Accurate Results Economical to use Large Touchscreen Display with Graphical User Interface.
Delivery & Availability:
Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock
Microprocessor control.
Digital display setting and actual temperature.
Over temperature alarm, PID self-tuning.
Digital display running timer.
Stainless steel interior.
Electricity leakage protection.
With glass inner door, With hidden door locks.
Mechanical overheat protection, cut off the heating sources.
Automatic alarm after operation.
Suitable for constant temperature tests.
Suitable for bacteria cultivation, breeding, ferment.
Delivery & Availability:
Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Content
PCR Cabinet Features:
Perforations at the back wall of the work zone which are designed to eliminate air turbulence and the possibility of dead air corners in the work zone.
Variable digital timer that provides UV light exposure continuously or in user-selected increments of 15, 30, 60,120 till 999 minutes to deactivate DNA and RNA contaminants.
Intuitive and easy-to-use microprocessor controller with LCD display, graphical and digital display of all the operating status of each function, such as filter life, UV life etc.
Ergonomic control panel location, centered and angled down for an easy reach & viewing.
The non-direct light source design can effectively relieve the operator's visual fatigue under the condition of ensuring the illumination.
Different sizes available from 2 feet to 6 feet, benchtop use or mounted on a mobile base.
Brushed stainless steel work surface is for easy cleaning.
Safety Performance:
Audio and visual alarm on filter life, UV life etc.
Front sliding sash interlock with fan and UV lamp.
Front sash and side windows are made of UV-resistant tempered glass.
The host and sockets have independent capacitors to prevent current overload.
Humanized design:
Standard shelves with IV bar.
Memory function in case of power-failure.
HEPA filter and UV life indicators facilitate a timely replacem ent plan.
Two sides glass windows installed for easy experiment observation.
Easy-to-change pre-filter installed could extend the HEPA filter’s lifetime.
Equipped with temperature sensor to show the real temperature during operation.
Waterproof socket provide convenience for small instruments to be used in the operating area.
PCR Cabinet Specifications:
Model
PCR-800
PCR-1100
PCR-1300
PCR-1600
PCR-1900
External Size (WxDxH)(mm)
710x680x1050 (Without Base Stand)
710x680x1670 (With Base Stand)
1050x710x1850
1320x710x1850
1625x710x1850
1930x710x1850
Internal Size (WxDxH)(mm)
610x590x625
950x615x625
1220x615x625
1525x615x625
1830x615x625
Work Surface Height
750mm
Control System
Microprocessor controller with LCD display, graphical and digital display of the operating status
Audio and visual alarm on filter and UV changing
Front sliding sash interlock with fan and UV lamp
HEPA filter and UV life indicators facilitate a timely replacement plan
Air Filtration System
Cleanness
ISO Class 5 (Formerly Class 100)
Airflow Velocity
0.2~0.5 m/s, speed adjustable
HEPA Filter
1 pcs, efficiency > 99.995% at particle size of 0.3 μm
Pre-Filter
1 pcs, made of washable polyester fiber
Partial Air Circulation
Perforations at the back wall of the work zone which are designed to eliminate air turbulence and the possibility of dead air corners in the work zone.
Sound Emission
≤62dB(A)
Illuminating Lamp
LED Type, Illumination ≥900Lx
UV Decontamination System
1. With timing function from 0 to 999 minutes
2. Interlock with front sliding sash.
3. Emission of 253.7 nanometers for best sterilization effect.
10Wx2
20Wx1
30Wx1
30Wx1
20Wx2
Power Consumption
149W
155W
285W
285W
300W
External devices connected via power sockets are not included
Cabinet Structure
Main Body: Electro-Galvanized steel with antimicrobial powder coating
Work Zone: 304 Stainless steel, an angled front, rounded work surface front edge
Side Windows: 5 mm UV resistant tempered glass
Power Supply
AC220V ±10%, 50/60Hz, 1P
Standard Accessories
LED lamp; UV lampx2; Waterproof socket×2 (only 1 for PCR-800); Shelves with IV bar
Optional Accessories
Base stand(only PCR-800); Water tap, Gas tap, Height adjustable base stand
Net Weight
80kg(Without
base stand), 130kg (With base stand)
-
Gross Weight
115kg (Without base stand), 165kg (With base stand)
225kg
255kg
285kg
330kg
Shipping Size (W×D×H mm)
920x850x1190
1190x990x1325
1460x990x1325
1765x990x1325
2070x990x1325
Shipping Volume
0.93m3
1.56m3
1.92m3
2.3m3
2.7m3
The coagulometer, LabPad® INR, measures blood coagulation time thanks to a patented optical technology. This portable In-Vitro Diagnostics (IVD) device works with the Tsmart® INR single-use microcuvettes.
User-friendly: the LabPad® INR is designed to be easy to use especially thanks to its 3D-shaped microcuvette that only requires a small drop of blood from a fingertip. Thanks to the color screen, both measurement steps and browsing the list of results are easy to visualize.
Quick and reliable: the reliability of INR results is obtained by quality controls that are performed automatically before each measurement. In less than one minute, you can see if you are in your therapeutic range.
Connected: the result obtained after performing the test can be transferred to healthcare professionals in charge of your treatment monitoring. This result is complementary to the pie charts and trend reports directly displayed on the LabPad® INR to help you monitoring your treatment
This Automatic Pipette will help you get your lab up and running in no time—at a great price!
Features:
Lowest operation and tip ejection forces
Fully autoclavable
Ultra light weight with space-age materials
Secondary adjustment option for various liquid classes
Spring loaded tip con
For transferring molecular samples and PCR mix solutions.
One set is for DNA work and the other for RNA work. Each with the following specs
Light weight, traditional tip shaft, and will fit all generic brands of tips
Equal to or better than accuracy and precision compared to ISO 8655, so results can be trusted.
Easy and quick volume adjustment with or without gloves. Foolproof volume lock prevents accidental volume changes.
Low maintenance and autoclavable 121° for at least 20 minutes
Quick release
The advanced B111 Bilirubinmeter provides fast, accurate results for Total bilirubin level in neonates with only 40μl serum or plasma sample. It determines total bilirubin by dual wavelength photometric
analysis. Suited for pediatric setups, small workload labs & hospitals because of its compact and portable design. Advanced, benchtop and precise instrument for measuring Total Bilirubin.
Feature
Auto zero function: Manual blanking not required
Dual wavelength measurement system:
2 wave lengths 455nm and 575nm
Plays major role to remove the interference caused due to Hemolysis & turbidity of sample
LED Light source:
LED does not require replacement as it lasts longer
As compared to Lamp, LED are more suitable as there is no intensity fluctuations
No warm up time required.
Flexible unit selection:
Two units either mg/dl or umol/L are selectable, ease of reporting
Compact slot for Capillary:
Accuracy of results are directly related to proper alignment of Capillary
B-111 has the easiest mode to ensure precise values
Data transfer:
External device can be connected to instrument through RS232 por
Electrolyte Analyzer ERMA EL-120 is ideal for medium to high volume Laboratories and Hospitals . It offers reliable, automated samples handling and work flow offences . It also allows measurement of specific ions, accurately and precisely . This supports fast diagnosis of critically ill patients and reduces the risks of patient discomfort associated with repeated sampling Precise & Accurate Results Economical to use Large Touchscreen Display with Graphical User Interface.
Features:
Parameters: Na+,K+,Cl-, iCa++ / Li
It works on ISE principle
Sample Type: Whole blood, Serum, Plasma, Urine
Low reagent consumption
Sample requirement is only 90ul
60 samples per hour
Automatic two point calibration after 4hrs and one point calibration with each sample analysis
Air bubble detection
Track reagents consumption and provides alerts
For low reagent volume
Precision testing facility to get CV and SD
Trilevel Quality Control with LJ plots of last 30days
Reviews