| Description | In stock 
 	Delivery & Availability:
Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.Total Volume: 60mL.Specimen Container, Leak-proof, Ideal for Pathology/Histology/Cytology reagent pre-filling sample preparation.Made of premium PP material, it is durable for usage.Some measurements can be used to not only use urine samples, it can also be used for other liquids. | In Stock
Twenty Five (25) Test Strip per Pack Delivery & Availability:Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | In stock The technical innovation of the iSED® fully-automated ESR analyzer consists of directly measuring the intensity of the red cell aggregation which is responsible for Erythrocyte Sedimentation Rate (ESR).
Delivery & Availability:
Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
 | Shipped From Abroad Electrolyte Analyzer ERMA EL-120 is ideal for medium to high volume Laboratories and Hospitals . It offers reliable, automated samples handling and work flow offences . It also allows measurement of specific ions, accurately and precisely . This supports fast diagnosis of critically ill patients and reduces the risks of patient discomfort associated with repeated sampling Precise & Accurate Results Economical to use Large Touchscreen Display with Graphical User Interface.
Delivery & Availability:
Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
 | In stock 
 
 	Delivery & Availability:
Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.Made of high quality PP material with good transparency.Applied for Gilson/Finland/Eppendorf Pipettors.Carefully inspect of raw material and manufactured under strict process check, all tips are with excellent accuracy and precison.
Special siliconizing on the inner surface ensure no liquid adhesion and accurate sample transfer.Standard tips and filter tips can be autoclaved, high temperature sterilization acceptable. | In stock 
Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
The Discover Cup is an all-in-one drug of abuse test cup. The strips are self contained and the entire cup is tamper resistant.
Delivery & Availability:
 | 
| Content | 
 	Total Volume: 60mL.Specimen Container, Leak-proof, Ideal for Pathology/Histology/Cytology reagent pre-filling sample preparation.Made of premium PP material, it is durable for usage.Some measurements can be used to not only use urine samples, it can also be used for other liquids. | Twenty Five (25) Test Strip per Pack | The technical innovation of the iSED® fully-automated ESR analyzer consists of directly measuring the intensity of the red cell aggregation which is responsible for Erythrocyte Sedimentation Rate (ESR). Unlike traditional ESR methodologies that measure the aggregation of the red blood cells indirectly, the iSED measures it directly and expresses the values in mm/hr.
Features: 
 	Technical Specifications:
100µL sample drawn directly from primary EDTA tube
Fully automated, walk-away operation
Positive patient identification via internal barcode reader
Compatible with pediatric tube 
Click Here To Download Catalogue
| Principle of Measure: | Photometrical |  
| Results: | “Printed mm/hr, Range from 1-130 mm/hr” |  
| Sample Requirements: | 500uL whole blood, collected in EDTA anti-coagulant tested 24 hours from venipuncture at room temperature or refrigerated. |  
| Tube Requirements: | 13 x 75 mm, pierceable capped tube |  
| Quality Control: | Barcoded Seditrol® QC |  
| Barcode Reader: | Internal |  
| Printer: | Internal |  
| Interface Specifications: | serial RS232 port for LIS connection |  
| Weight: | 14 kg |  
| Dimensions (H x W x D): | 36 x 27 x 34 (cm) /14.3 x 10.5 x13.4 (in) |  
| Voltage: | 100-240VAC |  
| Frequency Range: | 50-60 Hz |  
| Power: | 160W |  | Electrolyte Analyzer ERMA EL-120 is ideal for medium to high volume Laboratories and Hospitals . It offers reliable, automated samples handling and work flow offences . It also allows measurement of specific ions, accurately and precisely . This supports fast diagnosis of critically ill patients and reduces the risks of patient discomfort associated with repeated sampling Precise & Accurate Results Economical to use Large Touchscreen Display with Graphical User Interface.
Features: 
 	Technical Specifications:Parameters: Na+,K+,Cl-, iCa++ / LiIt works on ISE principleSample Type: Whole blood, Serum, Plasma, UrineLow reagent consumptionSample requirement is only 90ul60 samples per hourAutomatic two point calibration after 4hrs and one point calibration with each sample analysisAir bubble detectionTrack reagents consumption and provides alertsFor low reagent volumePrecision testing facility to get CV and SDTrilevel Quality Control with LJ plots of last 30daysLow aspiration volumeFast sample processingAccurate and Precise results 
| Parameters | Na+, K+, Cl– /Ca++ |  
| Principle | Ion Selective Electrode (ISE) |  
| Sample Type | Analyses whole blood, serum, plasma and urine |  
| Sample Volume | ≤100 µL |  
| Analysis Time | ≤60 seconds |  
| Throughout | ≤60 samples per hour |  
| Data Link | Serial (RS232) |  
| External Interface | USB (Keyboard, Mouse) |  
| Operating Condition | 10° C to 35° C, Relative Humidity up to 85% |  
| Storage Condition | Temp: 10° C to 40° C |  
| Relative Humidity | up to 85% non- condensing |  
| Power Supply | 100 to 240 VAC ±10%, 50Hz |  
| Dimensions | 395 x 260 x 375 mm |  
| Weight | 7.5 kg |  | 
 	Classification: PIPETTE
Brand Name: Vchanslab,Yingmed,OEM
Model Number: YM-K7028
Place of Origin: China
Product name: Pipette Tips
Material: Polypropylene
Certificate: CE/ISO13485/FDA
Color: Natural, Blue, Yellow
Application: Laboratory, Teaching, HospitalMade of high quality PP material with good transparency.Applied for Gilson/Finland/Eppendorf Pipettors.Carefully inspect of raw material and manufactured under strict process check, all tips are with excellent accuracy and precison.
Special siliconizing on the inner surface ensure no liquid adhesion and accurate sample transfer.Standard tips and filter tips can be autoclaved, high temperature sterilization acceptable. | FDA 510(K) & CLIA Waived
Up to 99% accuracy rate
Results in as little as 1 minute
24 Month Shelf Life from Date of Manufacture
Secure, seal and send to lab for confirmation
Built in temperature strip
Available to test up to 17 substances with adulterants or 18 without adulterants
Adulterants available | 
Reviews