Platelet Preservation Box

$0.00

Shipped From Abroad

Model : PPB-I; PPB-II; PPB-III; PPB-IV; PPB-V

This Platelet Preservation Box is designed to maintain the quality of platelet concentrates during transportation by providing a controlled temperature and gentle agitation.

Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
SF1033560130127-63
Brands:: Scitek

Description

Features:
  •  Adopting IPS high-definition touch display
  • Multiple ways to monitor equipment temperature
  • With UV disinfection and lighting functions
  • High/low temperature alarm; Abnormal shutdown alarm; The oscillation device (motor) is faulty alarm; Automatic alarm if the equipment door is not closed tightly
  • New anti-slip coated drawer shelves
  • Microprocessor control
  • Air cooled R134a non- fluorocarbon refrigerant
  • Silent casters with lock for easy movement
  • Equipped with leakage protector
  • Automatic frost and defrost function
  • Double-layer tempered glass door with good thermal insulation effect

 

Platelet Preservation Box Specifications:
Model PPB-I PPB-II PPB-III PPB-IV PPB-V
Temperature Control method Digital signal detection, Microprocessor control
Temperature Control Range 22±2℃
Temperature Control Accuracy ±0.1℃
Environmental Temperature 5~35℃
Alarm Temperature <20℃, >24℃,Abnormal shutdown and power outage alarm
Oscillation Frequency 60±5 cycles/min
Oscillation Amplitude 50mm
Working Mode Continuously reciprocates left and right, oscillating horizontally
Storage Area and Number of Layers 430x380x470mm; 5 layers 430x380x480mm; 7 layers 585x545x410mm; 10 layers 590x450x1130mm; 20 layers 1300x450x1130mm;
10 layers x 4 (Double Door)
Number of Blood Bags Stored (Optimal/Maximum) 5/10 bags 7/14 bags 20/40 bags 60/100 bags 120/200 bags
Heating Consumption 200W 400W
Refrigeration Consumption 300W 500W
Power Supply AC220/110V, 50/60Hz
Size(W×D×H)(mm) 540x595x970 690x680x1050 720x750x1700 1450x750x1700
Shipping Size (W×D×H)(mm) 650x710x1130 670x720x1150 820x800x1230 760x790x1930 1530x930x1780
G.W. (kg) 85 85 90 160 280

 

Optional:

1. Wireless monitoring system

2. Scanner, scanning the plasma bag barcode

3. UPS power supply

4. Connecting to LIS system

Reviews

There are no reviews yet.

Be the first to review “Platelet Preservation Box”

Your email address will not be published. Required fields are marked *

Quick Comparison

SettingsPlatelet Preservation Box removeAvalun LabPad Device removePlastic Urine Container Per Pack removeEppendorf Minispin Centrifuge removeErma B-111 Bilirubin Meter removeAGD Erma EL-120 ELectrolyte Analyzer remove
NamePlatelet Preservation Box removeAvalun LabPad Device removePlastic Urine Container Per Pack removeEppendorf Minispin Centrifuge removeErma B-111 Bilirubin Meter removeAGD Erma EL-120 ELectrolyte Analyzer remove
ImageAvalun Labpad machine
SKUSF1033560130127-63SF1033560084-65SF1033560084-106SF1033560084-116SF1033560084-6SF1033560084-125
Rating
Price

$0.00

$0.00

$8.20

$0.00

$715.00

$1,320.00

Stock
Availability
Add to cart

DescriptionShipped From Abroad Model : PPB-I; PPB-II; PPB-III; PPB-IV; PPB-V This Platelet Preservation Box is designed to maintain the quality of platelet concentrates during transportation by providing a controlled temperature and gentle agitation.
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock The coagulometer, LabPad® INR, measures blood coagulation time thanks to a patented optical technology. This portable In-Vitro Diagnostics (IVD) device works with the Tsmart® INR single-use microcuvettes. Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.In stock
  • Total Volume: 60mL.
  • Specimen Container, Leak-proof, Ideal for Pathology/Histology/Cytology reagent pre-filling sample preparation.
  • Made of premium PP material, it is durable for usage.
  • Some measurements can be used to not only use urine samples, it can also be used for other liquids.
Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock
Powerful and user-friendly MiniSpin Centrifuge are small enough so that each workstation can be equipped with a “personal” centrifuge. The rotor, inner centrifuge lid, and lid latch are made of metal for maximum operation safety. Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Aboard  The advanced B111 Bilirubinmeter provides fast, accurate results for Total bilirubin level in neonates with only 40μl serum or plasma sample. It determines total bilirubin by dual wavelength photometric analysis. Suited for pediatric setups, small workload labs & hospitals because of its compact and portable design. Advanced, benchtop and precise instrument for measuring Total Bilirubin.

Delivery & Availability:

Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad
Electrolyte Analyzer ERMA EL-120 is ideal for medium to high volume Laboratories and Hospitals . It offers reliable, automated samples handling and work flow offences . It also allows measurement of specific ions, accurately and precisely . This supports fast diagnosis of critically ill patients and reduces the risks of patient discomfort associated with repeated sampling Precise & Accurate Results Economical to use Large Touchscreen Display with Graphical User Interface. Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Content
Features:
  •  Adopting IPS high-definition touch display
  • Multiple ways to monitor equipment temperature
  • With UV disinfection and lighting functions
  • High/low temperature alarm; Abnormal shutdown alarm; The oscillation device (motor) is faulty alarm; Automatic alarm if the equipment door is not closed tightly
  • New anti-slip coated drawer shelves
  • Microprocessor control
  • Air cooled R134a non- fluorocarbon refrigerant
  • Silent casters with lock for easy movement
  • Equipped with leakage protector
  • Automatic frost and defrost function
  • Double-layer tempered glass door with good thermal insulation effect
 
Platelet Preservation Box Specifications:
Model PPB-I PPB-II PPB-III PPB-IV PPB-V
Temperature Control method Digital signal detection, Microprocessor control
Temperature Control Range 22±2℃
Temperature Control Accuracy ±0.1℃
Environmental Temperature 5~35℃
Alarm Temperature <20℃, >24℃,Abnormal shutdown and power outage alarm
Oscillation Frequency 60±5 cycles/min
Oscillation Amplitude 50mm
Working Mode Continuously reciprocates left and right, oscillating horizontally
Storage Area and Number of Layers 430x380x470mm; 5 layers 430x380x480mm; 7 layers 585x545x410mm; 10 layers 590x450x1130mm; 20 layers 1300x450x1130mm; 10 layers x 4 (Double Door)
Number of Blood Bags Stored (Optimal/Maximum) 5/10 bags 7/14 bags 20/40 bags 60/100 bags 120/200 bags
Heating Consumption 200W 400W
Refrigeration Consumption 300W 500W
Power Supply AC220/110V, 50/60Hz
Size(W×D×H)(mm) 540x595x970 690x680x1050 720x750x1700 1450x750x1700
Shipping Size (W×D×H)(mm) 650x710x1130 670x720x1150 820x800x1230 760x790x1930 1530x930x1780
G.W. (kg) 85 85 90 160 280
  Optional: 1. Wireless monitoring system 2. Scanner, scanning the plasma bag barcode 3. UPS power supply 4. Connecting to LIS system
The coagulometer, LabPad® INR, measures blood coagulation time thanks to a patented optical technology. This portable In-Vitro Diagnostics (IVD) device works with the Tsmart® INR single-use microcuvettes.
  • User-friendly: the LabPad® INR is designed to be easy to use especially thanks to its 3D-shaped microcuvette that only requires a small drop of blood from a fingertip. Thanks to the color screen, both measurement steps and browsing the list of results are easy to visualize.
  • Quick and reliable: the reliability of INR results is obtained by quality controls that are performed automatically before each measurement. In less than one minute, you can see if you are in your therapeutic range.
  • Connected: the result obtained after performing the test can be transferred to healthcare professionals in charge of your treatment monitoring. This result is complementary to the pie charts and trend reports directly displayed on the LabPad® INR to help you monitoring your treatment
 
Click Here To Download Catalogue
   
  • Total Volume: 60mL.
  • Specimen Container, Leak-proof, Ideal for Pathology/Histology/Cytology reagent pre-filling sample preparation.
  • Made of premium PP material, it is durable for usage.
  • Some measurements can be used to not only use urine samples, it can also be used for other liquids.
Powerful and user-friendly MiniSpin Centrifuge are small enough so that each workstation can be equipped with a “personal” centrifuge. The rotor, inner centrifuge lid, and lid latch are made of metal for maximum operation safety. Features:
  • Rotor capacity: 12 x 1.5/2.0 mL vessels, 2 x PCR strip
  • Max. speed: 14,100 x g (14,500 rpm)
  • Extremely compact footprint — measures 9”W x 4.”H x 9ó”D!
  • Aluminum rotor accommodates twelve 1.5- or 2.0-mL tubes (maximum diameter of 11 mm)
  • Rotor can be autoclaved at 121°C for 20 minutes
  • Minimal sample heat transfer — maximum of 12°C after 20 minutes at max speed
  • Eliminate costly repairs with the low maintenance drive
  • Soft-touch lid closure for ergonomic lid locking — and releases automatically at the end of a run
Technical Specifications:
Speed: 800 – 13,400 rpm (100 rpm steps)
Capacity: 12 x 1.5/2.0 mL
Electrical: 120 V, 60 Hz
Dimensions: (W x D x H) 22.6 x 23.9 x 12.0 cm
Weight: 4.3 kg
 
Click Here To Download Catalogue
The advanced B111 Bilirubinmeter provides fast, accurate results for Total bilirubin level in neonates with only 40μl serum or plasma sample. It determines total bilirubin by dual wavelength photometric analysis. Suited for pediatric setups, small workload labs & hospitals because of its compact and portable design. Advanced, benchtop and precise instrument for measuring Total Bilirubin. Feature
  • Auto zero function: Manual blanking not required
  • Dual wavelength measurement system:
  • 2 wave lengths 455nm and 575nm
  • Plays major role to remove the interference caused due to Hemolysis & turbidity of sample
  • LED Light source:
  • LED does not require replacement as it lasts longer
  • As compared to Lamp, LED are more suitable as there is no intensity fluctuations
  • No warm up time required.
  • Flexible unit selection:
  • Two units either mg/dl or umol/L are selectable, ease of reporting
  • Compact slot for Capillary:
  • Accuracy of results are directly related to proper alignment of Capillary
  • B-111 has the easiest mode to ensure precise values
  • Data transfer:
  • External device can be connected to instrument through RS232 por
  • USB port
Technical Specification
  • Light source - LED
  • Wavelength - 455nm and 575nm
  • Net weight - 1kg
  • Measuring range - 0-30 mg/dl , 510 umol/L
  • Display - 16×2 LCD module with backlight
  • Auto calibration - Yes
  • Sample type - Serum or plasma
  • Sample volume - 40-80μL
  • Test time - <5sec
  • Units - mg/dl or umol/L
  • Dimensions - 150 (W) × 115 (H) × 190 (D) mm
  • Interface - RS232
  • Reading cuvette - Heparinized micro capillary holder
  • Storage temperature - 15-40°c
  • Power supply - DC 9V(DC adapter)
  • Power consumption - <2W
Electrolyte Analyzer ERMA EL-120 is ideal for medium to high volume Laboratories and Hospitals . It offers reliable, automated samples handling and work flow offences . It also allows measurement of specific ions, accurately and precisely . This supports fast diagnosis of critically ill patients and reduces the risks of patient discomfort associated with repeated sampling Precise & Accurate Results Economical to use Large Touchscreen Display with Graphical User Interface. Features:
  • Parameters: Na+,K+,Cl-, iCa++ / Li
  • It works on ISE principle
  • Sample Type: Whole blood, Serum, Plasma, Urine
  • Low reagent consumption
  • Sample requirement is only 90ul
  • 60 samples per hour
  • Automatic two point calibration after 4hrs and one point calibration with each sample analysis
  • Air bubble detection
  • Track reagents consumption and provides alerts
  • For low reagent volume
  • Precision testing facility to get CV and SD
  • Trilevel Quality Control with LJ plots of last 30days
  • Low aspiration volume
  • Fast sample processing
  • Accurate and Precise results
Technical Specifications:
Parameters Na+, K+, Cl– /Ca++
Principle Ion Selective Electrode (ISE)
Sample Type Analyses whole blood, serum, plasma and urine
Sample Volume ≤100 µL
Analysis Time ≤60 seconds
Throughout ≤60 samples per hour
Data Link Serial (RS232)
External Interface USB (Keyboard, Mouse)
Operating Condition 10° C to 35° C, Relative Humidity up to 85%
Storage Condition Temp: 10° C to 40° C
Relative Humidity up to 85% non- condensing
Power Supply 100 to 240 VAC ±10%, 50Hz
Dimensions 395 x 260 x 375 mm
Weight 7.5 kg
 
Click Here To Download Catalogue
WeightN/AN/AN/AN/AN/AN/A
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • Rating
  • Price
  • Description
Click outside to hide the comparison bar
Compare