Portable Conductivity Meter, 3/5 Calibration Points

$0.00

Shipped From Abroad

Model : CON-P520; CON-TP530; CON-SP531; CON-TSRP540

Easy-to-use, waterproof portable conductivity meter designed for routine analysis and quality control.

Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
SF1033560130127-118
Brands:: Scitek

Description

Portable Conductivity Meter Features:

Several multi-parameter portable conductivity meters support the measurement of conductivity, pH, TDS, temperature, salinity, and resistivity.

Portable conductivity meters are small in size, easy to carry, and have reinforced and waterproof protection for the case and sensor, which can be used for a variety of outdoor testing.

1 to 5 point calibration, automatic recognition of conductivity standards. Measurement accuracy: 0.5% F.S. These portable conductivity meters are suitable for use in a variety of industries such as experimental research, school education, and aquaculture. Optional electrode constant (K=0.1/1/10), reference temperature (20/25°C), TDS conversion factor, linear and pure water compensation modes.

  1. Automatic temperature compensation, corrects conductivity measurements and converts readings to reference temperature.
  2. Automatic endpoint lock, retains stable readings for easy viewing and recording.
  3. Calibration report, showing calibration points and conductivity cell coefficients.
  4. Automatic power off, saving battery power.
  5. Reset function automatically restores meter to factory default settings.
  6. Expandable memory to store or access up to 500 data sets.
  7. USB interface, easy to transfer data to PC.
  8. Multi-mode power supply ensures smooth application of the meter.

 

Portable Conductivity Meter Specifications:
Model CON-P520 CON-TP530 CON-SP531 CON-TSRP540
Conductivity Range 0.01~20.00, 200.0, 2000µS/cm, 20.00, 200.0mS/cm
Resolution 0.001,0.01,0.1,1
Accuracy ±0.5% F.S.
Calibration Points 1 to 3 points (CON-P520), 1 to 5 points (others)
Calibration Solutions 10µS/cm, 84µS/cm, 1413µS/cm, 12.88mS/cm, 111.8mS/cm
TDS Range 0~10.00, 100.0, 1000ppm,

10.00, 200.0ppt

0~10.00, 100.0, 1000ppm,

10.00, 200.0ppt

Resolution 0.01, 0.1, 1 0.01, 0.1, 1
Accuracy ±1%FS. ±1%FS.
TDS Factor 0.1~1.0 (default 0.5) 0.1~1.0 (default 0.5)
Salinity Range 0.00~42.00psu,

0.00~ 80.00ppt

0.00~42.00psu,

0.00~80.00ppt

Resolution 0.01 0.01
Accuracy ±1% F.S. ±1% F.S.
Resistivity Range 0.00~20.00MΩ
Resolution 0.01
Accuracy ±1% FS.
Temperature Range 0~105°C/32~221°F
Resolution 0.1°C/0.1°F
Accuracy ±0.5°C/±0.9°F
Offset Calibration 1 point, reading ±10°C
Other

Specifications

Temperature

Compensation

0~100°C, manual or automatic
Temperature

Coefficient

Linear (0.0~10.0%/°C), non-linear, pure water
Reference

Temperature

20/25℃
Cell Constant K=0.1, 1, 10
Stability Criteria Low ar high Low ar high Low ar high
Calibration Due Alarm 1 to 31 days or off 1 to 31 days or off 1 to 31 days or off
Hold Function Manual or auto endpoint
Auto-Off 30 minutes after

last key pressed

10, 20 or 30 minutes after last key pressed
Memory 100 data sets (CON-P520), 500 data sets (others)
Communication

Interface

USB
Connector 6-pin mini-DIN, 3.5mm jack socket
Display Custom LCD (80×60mm)
Power Requirements 3×1.5V AA batteries or DC 5V power adapter
Battery Life Approximately 150 hours(Turn off the backlight)
Sizes(W×D×H) 170×85×30
Shipping Size

(W×D×H)(mm)

350x10x300
N.W./G.W. (kg) 0.3/1.5

Reviews

There are no reviews yet.

Be the first to review “Portable Conductivity Meter, 3/5 Calibration Points”

Your email address will not be published. Required fields are marked *

Quick Comparison

SettingsPortable Conductivity Meter, 3/5 Calibration Points removeDiscover 5 Panel Cup with Adulterants Per Pack removeSkyla Hi POC Clinical Chemistry Analyzer removeEppendorf Pipette Tip 20ul Per Pack removeiSED Fully Automated ESR Analyzer removeAGD Erma EL-120 ELectrolyte Analyzer remove
NamePortable Conductivity Meter, 3/5 Calibration Points removeDiscover 5 Panel Cup with Adulterants Per Pack removeSkyla Hi POC Clinical Chemistry Analyzer removeEppendorf Pipette Tip 20ul Per Pack removeiSED Fully Automated ESR Analyzer removeAGD Erma EL-120 ELectrolyte Analyzer remove
ImageDrug Test CupEppendorf Pipette Tip 20ul Per Pack
SKUSF1033560130127-118SF1033560084-23SF1033560060-2SF1033560084-136SF1033560084-129SF1033560084-125
Rating
Price

$0.00

$0.00

$0.00

$0.00

$0.00

$1,320.00

Stock
Availability
Add to cart

DescriptionShipped From Abroad Model : CON-P520; CON-TP530; CON-SP531; CON-TSRP540 Easy-to-use, waterproof portable conductivity meter designed for routine analysis and quality control.
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock
The Discover Cup is an all-in-one drug of abuse test cup. The strips are self-contained and the entire cup is tamper resistant. Delivery & Availability:
Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped from Abroad The skyla Hi POC Clinical Chemistry Analyzer provides clinical testing laboratories of medical facilities and clinics with an in-vitro clinical chemistry diagnostic tool that is compact, portable, and reports rapid results.The use of skyla Hi in the management of diabetes enables better access to testing and rapid clinical decision making, discussion,and implementation of optimized treatment. Delivery & Availability: Typically 14 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.In stock
  • Made of high quality PP material with good transparency.
  • Applied for Gilson/Finland/Eppendorf Pipettors.
  • Carefully inspect of raw material and manufactured under strict process check, all tips are with excellent accuracy and precison.
  • Special siliconizing on the inner surface ensure no liquid adhesion and accurate sample transfer.
  • Standard tips and filter tips can be autoclaved, high temperature sterilization acceptable.
Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock
The technical innovation of the iSED® fully-automated ESR analyzer consists of directly measuring the intensity of the red cell aggregation which is responsible for Erythrocyte Sedimentation Rate (ESR). Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad
Electrolyte Analyzer ERMA EL-120 is ideal for medium to high volume Laboratories and Hospitals . It offers reliable, automated samples handling and work flow offences . It also allows measurement of specific ions, accurately and precisely . This supports fast diagnosis of critically ill patients and reduces the risks of patient discomfort associated with repeated sampling Precise & Accurate Results Economical to use Large Touchscreen Display with Graphical User Interface. Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Content
Portable Conductivity Meter Features:
Several multi-parameter portable conductivity meters support the measurement of conductivity, pH, TDS, temperature, salinity, and resistivity. Portable conductivity meters are small in size, easy to carry, and have reinforced and waterproof protection for the case and sensor, which can be used for a variety of outdoor testing. 1 to 5 point calibration, automatic recognition of conductivity standards. Measurement accuracy: 0.5% F.S. These portable conductivity meters are suitable for use in a variety of industries such as experimental research, school education, and aquaculture. Optional electrode constant (K=0.1/1/10), reference temperature (20/25°C), TDS conversion factor, linear and pure water compensation modes.
  1. Automatic temperature compensation, corrects conductivity measurements and converts readings to reference temperature.
  2. Automatic endpoint lock, retains stable readings for easy viewing and recording.
  3. Calibration report, showing calibration points and conductivity cell coefficients.
  4. Automatic power off, saving battery power.
  5. Reset function automatically restores meter to factory default settings.
  6. Expandable memory to store or access up to 500 data sets.
  7. USB interface, easy to transfer data to PC.
  8. Multi-mode power supply ensures smooth application of the meter.
 
Portable Conductivity Meter Specifications:
Model CON-P520 CON-TP530 CON-SP531 CON-TSRP540
Conductivity Range 0.01~20.00, 200.0, 2000µS/cm, 20.00, 200.0mS/cm
Resolution 0.001,0.01,0.1,1
Accuracy ±0.5% F.S.
Calibration Points 1 to 3 points (CON-P520), 1 to 5 points (others)
Calibration Solutions 10µS/cm, 84µS/cm, 1413µS/cm, 12.88mS/cm, 111.8mS/cm
TDS Range 0~10.00, 100.0, 1000ppm, 10.00, 200.0ppt 0~10.00, 100.0, 1000ppm, 10.00, 200.0ppt
Resolution 0.01, 0.1, 1 0.01, 0.1, 1
Accuracy ±1%FS. ±1%FS.
TDS Factor 0.1~1.0 (default 0.5) 0.1~1.0 (default 0.5)
Salinity Range 0.00~42.00psu, 0.00~ 80.00ppt 0.00~42.00psu, 0.00~80.00ppt
Resolution 0.01 0.01
Accuracy ±1% F.S. ±1% F.S.
Resistivity Range 0.00~20.00MΩ
Resolution 0.01
Accuracy ±1% FS.
Temperature Range 0~105°C/32~221°F
Resolution 0.1°C/0.1°F
Accuracy ±0.5°C/±0.9°F
Offset Calibration 1 point, reading ±10°C
Other Specifications Temperature Compensation 0~100°C, manual or automatic
Temperature Coefficient Linear (0.0~10.0%/°C), non-linear, pure water
Reference Temperature 20/25℃
Cell Constant K=0.1, 1, 10
Stability Criteria Low ar high Low ar high Low ar high
Calibration Due Alarm 1 to 31 days or off 1 to 31 days or off 1 to 31 days or off
Hold Function Manual or auto endpoint
Auto-Off 30 minutes after last key pressed
10, 20 or 30 minutes after last key pressed
Memory 100 data sets (CON-P520), 500 data sets (others)
Communication Interface USB
Connector 6-pin mini-DIN, 3.5mm jack socket
Display Custom LCD (80×60mm)
Power Requirements 3×1.5V AA batteries or DC 5V power adapter
Battery Life Approximately 150 hours(Turn off the backlight)
Sizes(W×D×H) 170×85x30
Shipping Size (W×D×H)(mm) 350x10x300
N.W./G.W. (kg) 0.3/1.5
All-in-One Design
FDA 510K & CLIA Waived 99% Accurate Results in as little as 1 minute 24 Month Shelf Life from Date of Manufacture Secure, seal and send to lab for confirmation Built in temperature strip Available to test up to 14 substances Adulterants available
 
 
skyla Hi Analyzer enables better access to testing and rapid clinical decision making, discussion, and implementation of optimized treatment. To get the result, only prepare <1 μl fingertips blood or venous blood (depends on test item) without pretreatment with easy steps and then read the result after 6 mins. The device allows two specimens be tested in one run and provides fully automatic procedures from checking the validity of cartridge to printing the results. Reagent Kit
  • HbA1C
  • CRP
  • Lipid Panel (TC,TG, HDL, LDL#)
  • Lipid Plus Panel (Glu,TC,TG, HDL, LDL#)
Main Specification
Principle
Turbidimetric Method / Biochemistry
Device
Testing Time
5~20 minutes (depends on test items)
Display and Interface
5″ TFT color touch screen LCD
Memory Capacity
50,000 test results
Dimension of Analyzer
270 x 188 x 148 mm
Weight of Analyzer
1.7 kg
Dimension of Printer Module
134 x 100 x 82.7 mm
Weight of Printer Module
0.37 kg
Power Supply
100~240 volts AC, 50-60Hz
Data Transmission
USB 2.0*4 / USB 3.0*1 / RS232*1 / RJ45*1 / Wi-Fi (optional)
Reagent and Samples
Samples
Fingertips blood or venous blood
Samples Volume
0.8 ~ 30 μL (depends on test item)
Storage Temperature (Reagent)
2 ~ 8˚C
Humidity
Relative humidity < 95% (Non-condensing)
Temperature
10 ~ 32 ˚C
Click Here To Download Catalogue
  • Made of high quality PP material with good transparency.
  • Applied for Gilson/Finland/Eppendorf Pipettors.
  • Carefully inspect of raw material and manufactured under strict process check, all tips are with excellent accuracy and precison.
  • Special siliconizing on the inner surface ensure no liquid adhesion and accurate sample transfer.
  • Standard tips and filter tips can be autoclaved, high temperature sterilization acceptable.
  Classification: PIPETTE Brand Name: Vchanslab,Yingmed,OEM Model Number: YM-K7028 Place of Origin: China Product name: Pipette Tips Material: Polypropylene Certificate: CE/ISO13485/FDA Color: Natural, Blue, Yellow Application: Laboratory, Teaching, Hospital
The technical innovation of the iSED® fully-automated ESR analyzer consists of directly measuring the intensity of the red cell aggregation which is responsible for Erythrocyte Sedimentation Rate (ESR). Unlike traditional ESR methodologies that measure the aggregation of the red blood cells indirectly, the iSED measures it directly and expresses the values in mm/hr. Features:
  • Results in 20 Seconds

  • 100µL sample drawn directly from primary EDTA tube

  • Fully automated, walk-away operation

  • Random access

  • Positive patient identification via internal barcode reader

  • Compatible with pediatric tube

     
Technical Specifications: 
Principle of Measure: Photometrical
Results: “Printed mm/hr, Range from 1-130 mm/hr”
Sample Requirements: 500uL whole blood, collected in EDTA anti-coagulant tested 24 hours from venipuncture at room temperature or refrigerated.
Tube Requirements: 13 x 75 mm, pierceable capped tube
Quality Control: Barcoded Seditrol® QC
Barcode Reader: Internal
Printer: Internal
Interface Specifications: serial RS232 port for LIS connection
Weight: 14 kg
Dimensions (H x W x D): 36 x 27 x 34 (cm) /14.3 x 10.5 x13.4 (in)
Voltage: 100-240VAC
Frequency Range: 50-60 Hz
Power: 160W
Click Here To Download Catalogue
Electrolyte Analyzer ERMA EL-120 is ideal for medium to high volume Laboratories and Hospitals . It offers reliable, automated samples handling and work flow offences . It also allows measurement of specific ions, accurately and precisely . This supports fast diagnosis of critically ill patients and reduces the risks of patient discomfort associated with repeated sampling Precise & Accurate Results Economical to use Large Touchscreen Display with Graphical User Interface. Features:
  • Parameters: Na+,K+,Cl-, iCa++ / Li
  • It works on ISE principle
  • Sample Type: Whole blood, Serum, Plasma, Urine
  • Low reagent consumption
  • Sample requirement is only 90ul
  • 60 samples per hour
  • Automatic two point calibration after 4hrs and one point calibration with each sample analysis
  • Air bubble detection
  • Track reagents consumption and provides alerts
  • For low reagent volume
  • Precision testing facility to get CV and SD
  • Trilevel Quality Control with LJ plots of last 30days
  • Low aspiration volume
  • Fast sample processing
  • Accurate and Precise results
Technical Specifications:
Parameters Na+, K+, Cl– /Ca++
Principle Ion Selective Electrode (ISE)
Sample Type Analyses whole blood, serum, plasma and urine
Sample Volume ≤100 µL
Analysis Time ≤60 seconds
Throughout ≤60 samples per hour
Data Link Serial (RS232)
External Interface USB (Keyboard, Mouse)
Operating Condition 10° C to 35° C, Relative Humidity up to 85%
Storage Condition Temp: 10° C to 40° C
Relative Humidity up to 85% non- condensing
Power Supply 100 to 240 VAC ±10%, 50Hz
Dimensions 395 x 260 x 375 mm
Weight 7.5 kg
 
Click Here To Download Catalogue
WeightN/AN/AN/AN/AN/AN/A
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • Rating
  • Price
  • Description
Click outside to hide the comparison bar
Compare