Portable monitor with a 7-inch display, monitoring ETCO2 and SPO2, high accuracy, with a built-in rechargeable battery, CA200 has been designed to meet the requirements of clinical applications. Free Combination of any customized parameter can be satisfied. Its smaller size makes it the best choice for ambulances.

Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Brands:: Prior-care

Description

Features of Portable SPO2&ETCO2 Monitor CA200
  • 7-inch color LCD display with 800*480 resolution.
  • Easy to learn and use, simplified menus, and dedicated function keys.
  • Free Combination of any customized parameter.
  • 96 hours of data storage.
  • Rechargeable high-capacity built-in Li Battery, continuously working for over 8 hours.

 

Specifications of Portable SPO2&ETCO2 Monitor CA200
ECG
No of leads 3 lead
Lead View Selectable I, II or III
Gain Selection x1/4, x1/2, x1, and x2
Frequency Response Diagnostic Monitor: Surgery: Strong:
0.05 to 90Hz 0.5 to 35 Hz 1 – 15Hz 5 to 15 Hz
Defibrillator Protection Yes
Electrosurgery Protection Yes
Pacer Detection/Rejection Yes
Pulse Oximetry
Range 1% to 99%
Resolution 1%
Accuracy 70% to 99% range:±2%
50% to 69% range: undefined
Method Dual wavelength LED
Heart (Pulse) Rate
Source User selectable: ECG or SPO2
Range 20 to 300 bpm
Accuracy ±1 bpm or ± 1% (ECG) whichever is greater
Temperature
Channels 2
Range, Accuracy 20℃ to 45℃, ±0.1℃
Display Resolution ±0.1℃
Probe YSI-400 and YSI-700 series
ETCO2  (optional)
Units mmHg; kPa; %
Method Non-dispersive infrared; auto-calibrating
N2O Compensation Manual; On/Off, user selectable
Range 0 to 114 mmHg; 0 to 15%
Flow, Sample Rate Sidestream; 50 ml/min
Accuracy ±2 mmHg or 5% of reading
Respiration Rate
Rate 7-120 bpm (ECG), 2 to 120 bpm (CO2)
Resolution 1 breath/min
Accuracy ±2 breath/min
Trends
Memory 128 hours
Display Tabular, graphical
Interface & Display
Keys 9. membrane activated
Rotary Knob Push and rotate; 24 steps/turn
Screen 7-inch active color TFT
Resolution Internal Display: 800 x 480
Waveforms 8, maximum
Waveform Types ECG Lead I, II or III, aVR, aVL, aVF, V, Respiration, CO2; Pleth
Sweep Speed 6.25,12.5, 25, or 50 mm/sec
Languages English, Chinese
Power 
Voltage 100-240V AC 50/60 HZ
Power Consumption 35 W, typical
Battery 1 sealed lithium battery
Battery working time 8 hours, typical
Recharge Time 4.5 hours, typical
Temp& Humidity Operating: 15º to 30°, 10 to 90% RH, non-condensing
Storage: -5º to 50ºC, <90% RH, non-condensing
Optional Function CA200A:  ETCO2 + SPO2
CA200B: ETCO2+SPO2+ECG
CA200C: SPO2+ETCO2+Temp

Reviews

There are no reviews yet.

Be the first to review “Portable SPO2&ETCO2 Monitor CA200”

Your email address will not be published. Required fields are marked *

Quick Comparison

SettingsPortable SPO2&ETCO2 Monitor CA200 removeRender SD-M2000D Anesthetic Machine removeMediPlus Bain Circuit (Adult) removeRender SD-M2000B Anesthetic Machine removeLittman Stethoscope removeCWS 5000- Patient Warming Machine remove
NamePortable SPO2&ETCO2 Monitor CA200 removeRender SD-M2000D Anesthetic Machine removeMediPlus Bain Circuit (Adult) removeRender SD-M2000B Anesthetic Machine removeLittman Stethoscope removeCWS 5000- Patient Warming Machine remove
ImageLittman Stethoscope
SKUSF1033560011-15SF1033560084-21SF1033560011-10SF1033560084-5SF103356013087-1
Rating
Price

$0.00

$5,940.00

$28.00

$4,840.00

$13.20

$1,045.00

Stock
Availability
Add to cart

DescriptionShipped From Abroad

Portable monitor with a 7-inch display, monitoring ETCO2 and SPO2, high accuracy, with a built-in rechargeable battery, CA200 has been designed to meet the requirements of clinical applications. Free Combination of any customized parameter can be satisfied. Its smaller size makes it the best choice for ambulances.

Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped from Abroad
  • Contains Output interface for Anesthesia information management system.
  • Complete with backup battery for working more than 120 minutes.
Delivery & Availability: Typically 21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In Stock
  • Provided with 22mm Corrugated tube of length 1.6m
  • APL Valve
  • 2 L Antistatic Rebreathing bag
  • 6mm Green PVC tube of length 1.6m
Delivery & Availability: Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.  
Shipped from Abroad
  • Contains Output interface for Anesthesia information management system.
  • Complete with backup battery for working more than 30 minutes.
Delivery & Availability: Typically 21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In Stock
  • Monitor and assess a wide range of patients
  • Detect normal and abnormal sounds and rhythms
  • Useful in non-critical care environments such as a medical office, general ward, OB/GYN, ambulatory clinic or urgent care

Delivery & Availability:

Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Content
Features of Portable SPO2&ETCO2 Monitor CA200
  • 7-inch color LCD display with 800*480 resolution.
  • Easy to learn and use, simplified menus, and dedicated function keys.
  • Free Combination of any customized parameter.
  • 96 hours of data storage.
  • Rechargeable high-capacity built-in Li Battery, continuously working for over 8 hours.
 
Specifications of Portable SPO2&ETCO2 Monitor CA200
ECG
No of leads 3 lead
Lead View Selectable I, II or III
Gain Selection x1/4, x1/2, x1, and x2
Frequency Response Diagnostic Monitor: Surgery: Strong:
0.05 to 90Hz 0.5 to 35 Hz 1 – 15Hz 5 to 15 Hz
Defibrillator Protection Yes
Electrosurgery Protection Yes
Pacer Detection/Rejection Yes
Pulse Oximetry
Range 1% to 99%
Resolution 1%
Accuracy 70% to 99% range:±2%
50% to 69% range: undefined
Method Dual wavelength LED
Heart (Pulse) Rate
Source User selectable: ECG or SPO2
Range 20 to 300 bpm
Accuracy ±1 bpm or ± 1% (ECG) whichever is greater
Temperature
Channels 2
Range, Accuracy 20℃ to 45℃, ±0.1℃
Display Resolution ±0.1℃
Probe YSI-400 and YSI-700 series
ETCO2  (optional)
Units mmHg; kPa; %
Method Non-dispersive infrared; auto-calibrating
N2O Compensation Manual; On/Off, user selectable
Range 0 to 114 mmHg; 0 to 15%
Flow, Sample Rate Sidestream; 50 ml/min
Accuracy ±2 mmHg or 5% of reading
Respiration Rate
Rate 7-120 bpm (ECG), 2 to 120 bpm (CO2)
Resolution 1 breath/min
Accuracy ±2 breath/min
Trends
Memory 128 hours
Display Tabular, graphical
Interface & Display
Keys 9. membrane activated
Rotary Knob Push and rotate; 24 steps/turn
Screen 7-inch active color TFT
Resolution Internal Display: 800 x 480
Waveforms 8, maximum
Waveform Types ECG Lead I, II or III, aVR, aVL, aVF, V, Respiration, CO2; Pleth
Sweep Speed 6.25,12.5, 25, or 50 mm/sec
Languages English, Chinese
Power 
Voltage 100-240V AC 50/60 HZ
Power Consumption 35 W, typical
Battery 1 sealed lithium battery
Battery working time 8 hours, typical
Recharge Time 4.5 hours, typical
Temp& Humidity Operating: 15º to 30°, 10 to 90% RH, non-condensing
Storage: -5º to 50ºC, <90% RH, non-condensing
Optional Function CA200A:  ETCO2 + SPO2
CA200B: ETCO2+SPO2+ECG
CA200C: SPO2+ETCO2+Temp
Features:
  • Contains Output interface for Anesthesia information management system.
  • Complete with backup battery for working more than 120 minutes.
Click Here To Download Catalogue
   
 
  • Provided with 22mm Corrugated tube of length 1.6m
  • APL Valve
  • 2 L Antistatic Rebreathing bag
  • 6mm Green PVC tube of length 1.6m
Features:
  • Contains Output interface for Anesthesia information management system.
  • Complete with backup battery for working more than 30 minutes.
  Technical Specifications:
Model: SD-M2000B
Brand: RENDER
Origin: Made In China
Category: Electronics & Electricity / Electronic Instrument / Electricity Meter & Instrument
Label: anesthesia machine , anesthesia ventilator , anesthesia machine
 
Click Here To Download Catalogue
 
Littman Stethoscope Features:
  • Monitor and assess a wide range of patients
  • Detect normal and abnormal sounds and rhythms
  • Useful in non-critical care environments such as a medical office, general ward, OB/GYN, ambulatory clinic or urgent care
  • Fun and vibrant; match colour and finish to your personality
  • Designed for use with adult and pediatric patients
  • tunable, dual-sided stainless steel chest piece with open or closed bell
  • Non-chill bell sleeve for greater patient comfort
  • Soft-sealing ear-tips provide optimal comfort and excellent sound occlusion
  • Made in the USA without natural rubber latex

Two speed fan motor and two levels of flow rates. CWS 5000 can inflate a very large blanket as well as a small blanket. • Uses a DC motor, quieter and state of the art blower. • CWS 5000 is controlled and operated through a unique robust software developed by Care Essentials. • The Cocoon™ CWS 5000 is light and compact, yet very sturdy. • Designed to be user friendly. • We comply with all essential regulatory standards. We have FDA, CE, TGA, Japan Health approvals. CWS 5000 has been tested for IEC 60601-1 3rd Edition, AM 1 by UL, USA.
WeightN/AN/AN/AN/AN/AN/A
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • Rating
  • Price
  • Description
Click outside to hide the comparison bar
Compare