Rosenbaum Eye Chart

$0.00

Shipped From Abroad

The Rosenbaum Pocket Vision Screening Card utilizing PV Numbers™ with Acuity Testing on Side 1 and Continuous Text Reading on Side 2. Includes Jaeger and Snellen notations, pupil gauge, and rulers.

Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
SF1033560130172-50

Description

The Rosenbaum Pocket Vision Screening Card utilizing PV Numbers™ provides 20/800 distance equivalent testing when held at a distance of 16 inches (40 cm). This card fits easily in a pocket for quick, convenient visual acuity screening. This Pocket Eye Chart is printed on durable plastic, and includes matching 20/200 Jaeger notation. Side 1 also includes pupil diameter gauge.

Side 2 features continuous text format. This format helps to simulate everyday activities such as reading. This simulation leads to better testing of the patient and helps identify near vision problems that interfere with normal activities. Side 2 includes both metric and standard rulers.

Reviews

There are no reviews yet.

Be the first to review “Rosenbaum Eye Chart”

Your email address will not be published. Required fields are marked *

Quick Comparison

Rosenbaum Eye Chart removeOphthalmic Ultrasound Pachymeter removeRetinoscope removeAutomatic Computer Goldmann (Visual Field Analyzer) removeApplanation Tonometer removePortable Keratometer remove
NameRosenbaum Eye Chart removeOphthalmic Ultrasound Pachymeter removeRetinoscope removeAutomatic Computer Goldmann (Visual Field Analyzer) removeApplanation Tonometer removePortable Keratometer remove
ImageMecan SW 1000P Ophthalmic Ultrasound PachymeterMecan YZ24 Streak RetinoscopeMecan Applanation Tonometer YZ30XMecan SW 100 Portable Keratometer
SKUSF1033560130172-50SF1033560107-18SF1033560107-12SF103356013013SF1033560107-1SF1033560107-16
Rating
Price

$0.00

$2,365.00

$165.00

$3,850.00

$0.00

$0.00

Stock
Availability
Add to cart

DescriptionShipped From Abroad The Rosenbaum Pocket Vision Screening Card utilizing PV Numbers™ with Acuity Testing on Side 1 and Continuous Text Reading on Side 2. Includes Jaeger and Snellen notations, pupil gauge, and rulers.
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped from abroad
  • Large color liquid-crystal screen.
  • Touch screen input, easy operation.
  • Curve freezing: Manual/Auto mode, controlled by pedal.
  • Built-in speed thermal printer.
  • Can display ultrasound waveform when measuring.
Delivery & Availability: Typically 14 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.  
Shipped from abroad The product can quickly and precisely measure the astigmatism axis and is one of the necessary instruments in optometry inspection.
Delivery & Availability: Typically 14 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.  
In Stock
Features: The Bio-1000 automated perimeter absorbs the advantages of international advanced perimetry devices. It comprises the highly integrated computer, optics, machinery and electronics systems.   Delivery & Availability: Typically 7-14 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped from abroad The product is designed on the principle basis of Goldman tonometer. It can be connected with slit lamp(Carl Zeiss type).
Delivery & Availability: Typically 14 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.  
Shipped from abroad Ultra-small corneal curvature tester, is mainly used to measure the corneal curvature radius and diopter, wireless output print data.
Delivery & Availability: Typically 14 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.  
ContentThe Rosenbaum Pocket Vision Screening Card utilizing PV Numbers™ provides 20/800 distance equivalent testing when held at a distance of 16 inches (40 cm). This card fits easily in a pocket for quick, convenient visual acuity screening. This Pocket Eye Chart is printed on durable plastic, and includes matching 20/200 Jaeger notation. Side 1 also includes pupil diameter gauge. Side 2 features continuous text format. This format helps to simulate everyday activities such as reading. This simulation leads to better testing of the patient and helps identify near vision problems that interfere with normal activities. Side 2 includes both metric and standard rulers.Features:
  • Large color liquid-crystal screen.
  • Touch screen input, easy operation.
  • Curve freezing: Manual/Auto mode, controlled by pedal.
  • Built-in speed thermal printer.
  • Can display ultrasound waveform when measuring.
  • Each group is the average of 20 measurements.
  • Switch between IOP measured value and actual value.
  • Can input name, ID and operator's name.
Technical Specifications:
P scan probe 20MHZ, angle of 45 degrees makes easier operation
Resolution 5um
Measuring range 150um~1500um
Display SINGLE mode and MAP mode
The product can quickly and precisely measure the astigmatism axis and is one of the necessary instruments in optometry inspection. Features:
  • The filament can be rotated for 360° and move upward and downward. The brightness of the streak can be adjusted.
  • Quickly and precisely measure the astigmatism axis.
  • The light can be converged, radiated, and paralleled.
  • Automatic Power Off function effectively protects the bulb.
  • Two-steps adjustable brightness for bulb: S(Bright) and W(Dark).
Technical Specifications:
Working Distance 1 m
Streak 3 mm-20 mm
Streak Rotation 360°
Illumination Source 3V/2W, halogen bulb
Input Voltage AC 220V±10%, 50Hz±1Hz
Power Consumption 4.5 VA
The Bio-1000 automated perimeter absorbs the advantages of international advanced perimetry devices. It comprises the highly integrated computer, optics, machinery and electronics systems. Incorporated with the advanced configuration, comprehensive software inspection categories, and strictly in accordance with international Goldman standard, it provide scientific means for glaucoma, fundus disease, visual pathway injury and neurological diseases. Feature:         * Comprehensive real-time monitoring,Heiji-krakau physiological blind spot monitoring,gaze tracking/head position tracking,automatic measurement of pupil diameter, reduce the impact of pupil effect on visual field detection. * Personalized design,accurate clinical analysis,accurate and repid examination strategy. * Under international Goldman standard,providing a variety of classic test procedures and report analysis. Technical Specification:
Inspection range 90°
Inspection distance 30cm
Background light brightness White 31.5abs
Visual target brightness 1abs --- 10000abs
Visual target size Goldmann III
Visual target interval time 200ms
Visual target interval time Stardard or adjustment according to patient reflection
Threshold test model Center5°- 16°,center10°- 68, 24-2, 30-2, 30°- 60°,nasal step
Upper threshold test model 30°-40,30°-76,P-60,60°-81,60°-120,190°-135,nasal side
Special detection strategy Esterman monocular,Esterman binocular,user-customized test,150°driver monocular fast detection, 150°driver monocular standard detection, upper36°detection, blind spot detection, 150° horizontal straightness detection
Pupil size test Automatic
Fixation monitoring Blind spot monitoring, eye position deviation alarm, eyedeviation curve
Enviroment light detection Automatic
Analysis software Reliability analysis,single vision report,triple visionreport,GPA half vision analysis, GPA glaucoma developing analysis, VFI vision index analysis
Operation system Win7 above
 
Click Here To Download Catalogue
Applanation Tonometer is designed on the principle basis of Goldman tonometer. It can be connected with slit lamp(Carl Zeiss type). Features of Applanation Tonometer:
  • When used with slit lamp, it can be used to examine the eyes and measure ocular pressure.
  • Accurate measurement and total tolerance are less than 0.066KPa(0.55Hg).
  • Directly get the ocular pressure and do not need to look up the conversion table.
  • The measured ocular pressure is not affected by hardness of eye.
  • The affected?ocular volume is just 0.56 cubic millimeter.
  • Adjustable measuring pressure ensures the long-term stability and reliability.
Technical Specifications Applanation Tonometer:
  • Measuring Range: 0~1064 Kpa
  • Light Ring Displacement: 1.53×2=3.06mm
  • Diameter of Prism Head: 7mm
  • Moving Range of Prism Head: 3mm
Portable Keratometer Features: Ultra-small corneal curvature tester, is mainly used to measure the corneal curvature radius and diopter, wireless output print data. Technical Specifications:
Model SW-100
Measuring Range 6.5mm~9.5mm: ±0.05mm: 0.01mm
Precision ± 0.05mm
Resolution of Curvature Radius of Cornea 0.01mm
Single Measuring Time 0.03s
Output Wireless Infrared Thermal Printer
Can observe the eye directly through the screen.
Weight 0.5Kg(with batteries)
Dimension 240mmx90mmx60mm
Power 500mW+15%
WeightN/AN/AN/AN/AN/AN/A
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • Rating
  • Price
  • Description
Click outside to hide the comparison bar
Compare