The Schiötz Tonometer is a highly precise instrument used to measure intraocular pressure (IOP) for the diagnosis and prevention of glaucoma. It features a reliable agate bearing for long service life and an easy-to-read scale, supplied complete with three calibration weights.

Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Brands:: Riester

Description

Indispensable in ophthalmology, the Riester Schiötz Tonometer provides precise IOP measurement using the indentation method. The instrument is engineered with a high-quality agate bearing to ensure longevity and accuracy. It comes complete in a black deluxe case with velvet-look inserts, including three standard weights (5.5 g, 7.5 g, 10 g) and a conversion table for quick interpretation of the readings.

Features and benefits
  • High-quality agate bearing for an extremely long service life
  • Precision measurement on a scale of 0 to 20 subdivisions and 0 to -1 subdivisions
  • Easy-to-read scale with red pointer
  • Complete in a black deluxe case with velvet-look inserts
  • Supplied with three weights (5.5 g, 7.5 g, 10 g) and a conversion table
Product details
Schiötz Tonometer
Dimensions Height: 130 mm, Width: 45 mm, Weight: 24.4 g
Scale 0 to 20 graduation marks
0 to -1 graduation mark
One graduation mark corresponds to a stroke of 0.05 mm
Operating temperature 10 °C to 40 °C
Relative humidity 30% up to 70 % relative humidity, non-condensing
Storage temperature -20 °C to 70 °C
Storage relative humidity up to 85 % relative humidity, non-condensing
Air pressure 700 hPa – 1060 hPa

 

Download Catalogue

Reviews

There are no reviews yet.

Be the first to review “Schiötz Tonometer”

Your email address will not be published. Required fields are marked *

Quick Comparison

Schiötz Tonometer removePortable Keratometer removeSlit Lamp removeOphthalmic Ultrasound Pachymeter removeView Tester (Manual Phoropter) removeApplanation Tonometer remove
NameSchiötz Tonometer removePortable Keratometer removeSlit Lamp removeOphthalmic Ultrasound Pachymeter removeView Tester (Manual Phoropter) removeApplanation Tonometer remove
ImageMecan SW 100 Portable KeratometerMecan SLM-JX Slit Lamp SerialMecan SW 1000P Ophthalmic Ultrasound PachymeterMecan VT-8 View Tester (Manual Phoropter)Mecan Applanation Tonometer YZ30X
SKUSF1033560107-16SF1033560107-15SF1033560107-18SF1033560107-26SF1033560107-1
Rating
Price

$0.00

$0.00

$1,375.00

$2,365.00

$858.00

$0.00

Stock
Availability
Add to cart

DescriptionShipped From Abroad The Schiötz Tonometer is a highly precise instrument used to measure intraocular pressure (IOP) for the diagnosis and prevention of glaucoma. It features a reliable agate bearing for long service life and an easy-to-read scale, supplied complete with three calibration weights.
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped from abroad Ultra-small corneal curvature tester, is mainly used to measure the corneal curvature radius and diopter, wireless output print data.
Delivery & Availability: Typically 14 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.  
Shipped from abroad
  • Top Optical System.
  • High eyepoint, comfort.
  • Five steps drum zoom design, easier to use 6x, 10x, 16x, 25x, 40x magnification.
  • High Definition Eyepieces, More Comfortable for Viewing.
Delivery & Availability: Typically 14 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.  
Shipped from abroad
  • Large color liquid-crystal screen.
  • Touch screen input, easy operation.
  • Curve freezing: Manual/Auto mode, controlled by pedal.
  • Built-in speed thermal printer.
  • Can display ultrasound waveform when measuring.
Delivery & Availability: Typically 14 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.  
Ship from abroad
  • Equipped with comprehensive measuring functions, it provides SPH, CYL, AXIS and pupil distance optometry
  • Durable and easy to operate
  • Easily and intuitively read the sphere focal scale value
  • High eco-friendly materials
  • Design fitting the face curve and no stimulation
Delivery & Availability: Typically 14 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.  
Shipped from abroad The product is designed on the principle basis of Goldman tonometer. It can be connected with slit lamp(Carl Zeiss type).
Delivery & Availability: Typically 14 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.  
ContentIndispensable in ophthalmology, the Riester Schiötz Tonometer provides precise IOP measurement using the indentation method. The instrument is engineered with a high-quality agate bearing to ensure longevity and accuracy. It comes complete in a black deluxe case with velvet-look inserts, including three standard weights (5.5 g, 7.5 g, 10 g) and a conversion table for quick interpretation of the readings.
Features and benefits
  • High-quality agate bearing for an extremely long service life
  • Precision measurement on a scale of 0 to 20 subdivisions and 0 to -1 subdivisions
  • Easy-to-read scale with red pointer
  • Complete in a black deluxe case with velvet-look inserts
  • Supplied with three weights (5.5 g, 7.5 g, 10 g) and a conversion table
Product details
Schiötz Tonometer
Dimensions Height: 130 mm, Width: 45 mm, Weight: 24.4 g
Scale 0 to 20 graduation marks 0 to -1 graduation mark One graduation mark corresponds to a stroke of 0.05 mm
Operating temperature 10 °C to 40 °C
Relative humidity 30% up to 70 % relative humidity, non-condensing
Storage temperature -20 °C to 70 °C
Storage relative humidity up to 85 % relative humidity, non-condensing
Air pressure 700 hPa - 1060 hPa
  Download Catalogue
Portable Keratometer Features: Ultra-small corneal curvature tester, is mainly used to measure the corneal curvature radius and diopter, wireless output print data. Technical Specifications:
Model SW-100
Measuring Range 6.5mm~9.5mm: ±0.05mm: 0.01mm
Precision ± 0.05mm
Resolution of Curvature Radius of Cornea 0.01mm
Single Measuring Time 0.03s
Output Wireless Infrared Thermal Printer
Can observe the eye directly through the screen.
Weight 0.5Kg(with batteries)
Dimension 240mmx90mmx60mm
Power 500mW+15%
Slit Lamp Features:
  • Top Optical System.
  • High eyepoint, comfort.
  • Five steps drum zoom design, easier to use 6x, 10x, 16x, 25x, 40x magnification.
  • High Definition Eyepieces, More Comfortable for Viewing.
Technical Specifications:
Microscope Type Galileo Parallel
Optics Super Optic System
Magnification Change Way Drum Rotation
Eyepiece Magnification 12.5x
Total Magnifications 6x 10x, 16x, 25x, 40x
Diopter Adjustment -5D ~+5D
Slit Width 0-14MM Continuous
Slit Height 1-14MM Continuous
Slit Angle 0°- 180° Adjustable
Light Source LED
Light Spot Diameter 0.2mm,  2mm, 3mm, 5mm, 10mm, 14mm
Filter Heat Absorption; Grey; Redfree; Cobalt Blue
Fixation Red LED
Electrical
Illumination Bulb LED
Input Voltage 110V/220V (±10%)
Applanation Tonometer Interface Included
 
Features:
  • Large color liquid-crystal screen.
  • Touch screen input, easy operation.
  • Curve freezing: Manual/Auto mode, controlled by pedal.
  • Built-in speed thermal printer.
  • Can display ultrasound waveform when measuring.
  • Each group is the average of 20 measurements.
  • Switch between IOP measured value and actual value.
  • Can input name, ID and operator's name.
Technical Specifications:
P scan probe 20MHZ, angle of 45 degrees makes easier operation
Resolution 5um
Measuring range 150um~1500um
Display SINGLE mode and MAP mode
Features:
  • Equipped with comprehensive measuring functions, it provides SPH, CYL, AXIS and pupil distance optometry
  • Durable and easy to operate
  • Easily and intuitively read the sphere focal scale value
  • High eco-friendly materials
  • Design fitting the face curve and no stimulation
  • Easy to take and clean
  • Free switch between the cross-cylindrical lens and the rotary prism
  • When the rotating risk is turning by the sphere, it can make sphere power adjust 3.00D for big scope.
  • It is designed expediently and smartly for a particular cross cylinder. Supporting supplementary lens could increase scope of measurement.
Technical Specifications:
Sphere
Range:-19.00~+16.75m-1 Step: 0.25m-1, 3.00m-1
Cylinder
Range: 0.00~-6.00m-1(Measuring Range With Accessories0.00~-8.00m-1) Step: 0.25m-1
Cylinder Axis
Range: 0~180°, Step:5°
Distance of Optical center (also known as Pupil)
Range: 50~75mmStep: 1mm
Sight Switch
Range:∞~380mm (distance of Optical center is64mm)
Front Chin Test
Range: 0~16mm
Distance (from cornea vertex to the lens surface)
16mm
Standard Accessories Lens
two pieces of Auxiliary Cylinder -2.00m-1 and -0.12m-1 respectively
Standard Accessories
one piece of M2 Hexagon wrench , one piece of a Myopia Standard Card, two piece of Myopia Standard Card , one piece of standard card holder , a dust cover
Auxiliary Lens
“O”:Open aperture “R”:Retinoscope lens “R”:Retinoscope lens “R”:Retinoscope lens *Lens of +1.50m-1 ,It is suit for the distance of 67 centimeters “P”:Polaroid * it is used for examining the dioptric balance of eyes , Implicit strabismus and stereo vision “RMV”:Red Vertical maddox *Be used to examine Implicit strabismus “RMH”:Red horizontal maddox *Be used to examine Implicit strabismus “WMV”:Plane Vertical Maddox *Be used to examine Implicit strabismus “WMH”:Plane horizontal maddox *Be used to examine Implicit strabismus “RL”:Red lens *Be used to examine eye function, Blending function and Implicit strabismus “GL”:Green lens *Be used to examine eye function, Blending function and Implicit strabismus “+”:Test mark of optical center adjustment “+.12”:Dioptric of the Spherical Lens is +0.12m-1 *Be used for the semi-adjustment of sphere lens, 0.25m-1 “PH”:1mmPinhole lens *Be used to exclude visual non-refractive errors of the tested eye “6ΔU”:6ΔBottom-up prism *Be used to examine the rotating prism with the detection of nearly horizontal squint “10ΔI”:10ΔBottom-up prism *Be used to examine the rotating prism with the detection of nearly horizontal squint “±0.50”:Cross-cylindrical lens *Be used to examine the corrected dioptric of the Presbyopia and spherical lens “OC”:Black lens
size
338(L)×99(W)×292(H)mm
NW
about 5kg
Applanation Tonometer is designed on the principle basis of Goldman tonometer. It can be connected with slit lamp(Carl Zeiss type). Features of Applanation Tonometer:
  • When used with slit lamp, it can be used to examine the eyes and measure ocular pressure.
  • Accurate measurement and total tolerance are less than 0.066KPa(0.55Hg).
  • Directly get the ocular pressure and do not need to look up the conversion table.
  • The measured ocular pressure is not affected by hardness of eye.
  • The affected?ocular volume is just 0.56 cubic millimeter.
  • Adjustable measuring pressure ensures the long-term stability and reliability.
Technical Specifications Applanation Tonometer:
  • Measuring Range: 0~1064 Kpa
  • Light Ring Displacement: 1.53×2=3.06mm
  • Diameter of Prism Head: 7mm
  • Moving Range of Prism Head: 3mm
WeightN/AN/AN/AN/AN/AN/A
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • Rating
  • Price
  • Description
Click outside to hide the comparison bar
Compare