Single Phase Low Frequency Hybrid Solar Inverter VKS Series 300W-1200W

$0.00

Shipped From Abroad

Features:
  • Pure sine wave output
  • AC Charging current 15A
  • High-low voltage protection
  • Against overload, short-circuit Protection
  • Over voltage,battery reverse connection(optional)
  • Under-voltage and over-temperature protection
  • Selectable battery priority or utility priority
  • UPS function and AC charger function
  • Built in 10A/20A/30A solar charge PWM controller

 

Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
SF1033560130139-28
Brands:: Reeco Power

Description

Features:
  • Pure sine wave output
  • AC Charging current 15A
  • High-low voltage protection
  • Against overload, short-circuit Protection
  • Over voltage,battery reverse connection(optional)
  • Under-voltage and over-temperature protection
  • Selectable battery priority or utility priority
  • UPS function and AC charger function
  • Built in 10A/20A/30A solar charge PWM controller

 

Applications:
  • Mammogram
  • Ultrasound Equipments
  • Radiology rooms

 

Technical Specifications
MODEL VKS300W VKS500W VKS700W VKS800W VS1000W VKS1200W
Rated Power 300W 500W 700W 800W 1000W 1200W
Peak Power 600W 1000W 1400W 1600W 2000W 2400W
AC input voltage range 73V-135VAC(110VAC/120VAC) 145V-275VAC(220VAC /230VAC )
Input frequency range 45-65HZ
Battery voltage 12VDC /24VDC
DC voltage 12VDC:10.5 -15VDC/24VDC:21-30VDC
Solar Controller 10A/20A/30A
Solar Input 120W 240W 360W 480W 720W
Battery undervoltage alarm 10.5VDC /21VDC
Battery undervoltage protection 10VDC /20VDC
Battery overvoltage protection 17V±0.5V /34V±0.5V
Voltage overvoltage alarm 15V-16VDC/30V-32VDC
Overload protection Rated power of 110% or more
Temperature protection ≥85 °C alarm, ≥90 °C off the machine
Inverter output voltage 110VAC/120VAC/ 220VAC/230VAC ±2%
Inverter output frequency 50/60HZ±10%
Inverter output waveform pure sine wave
AC output voltage range AVR output 110VAC/120VAC/ 220VAC/230VAC ±10%
Output frequency range Automatic tracking
Conversion time <5ms
Cooling method Intelligent fan control, ≤42 °C fan slow working , ≥45 °C fan high working .
AC Charging current 15A
Working mode selection Free to choose(SET)
01: AC priority/Citypower priority:
When city power is available, the inverter will work AC output, city power will supply power to appliances.The city power and sun power will charges 2 kinds power to battery. When city power failed,Sun power will charge the battery and  use battery power(Solar power) to take the appliances.02: energy saving mode
load power ≤10% off the machine, ≥11% -100% turn on03: Solar power priority/ Battery priority
When it have sun power,sun power charges the battery and supply power to the appliances.When it does not have sun power or battery voltage ≤10.5V, inverter will automatic use city power to take the appliances, When battery voltage reach 13V inverter will use battery power and sun power.
External Size(mm) DxWxH 300*290*150mm
Packing Size(mm) DxWxH 350*350*405(2pcs)
Net Weight(KG) 5.5 6.5 7 8 9.5 10
Gross Weight(KG) 13 15 16 18 20 22

Reviews

There are no reviews yet.

Be the first to review “Single Phase Low Frequency Hybrid Solar Inverter VKS Series 300W-1200W”

Your email address will not be published. Required fields are marked *

Quick Comparison

Single Phase Low Frequency Hybrid Solar Inverter VKS Series 300W-1200W removeOPzV Tubular Gel Battery 60AH-3000AH removeLine Interactive UPS AP Series 1000VA-3000VA removeSingle Phase High Frequency Online UPS VT Series 1KVA-3KVA removeHigh Frequency Modular UPS VM Series removeLead Acid Gel Battery 33AH-250AH remove
NameSingle Phase Low Frequency Hybrid Solar Inverter VKS Series 300W-1200W removeOPzV Tubular Gel Battery 60AH-3000AH removeLine Interactive UPS AP Series 1000VA-3000VA removeSingle Phase High Frequency Online UPS VT Series 1KVA-3KVA removeHigh Frequency Modular UPS VM Series removeLead Acid Gel Battery 33AH-250AH remove
Image
SKUSF1033560130139-28SF1033560130139-18SF1033560130139-16SF1033560130139-25SF1033560130139-11SF1033560130139-14
Rating
Price

$0.00

$0.00

$0.00

$0.00

$0.00

$0.00

Stock
Availability
Add to cart

DescriptionShipped From Abroad
Features:
  • Pure sine wave output
  • AC Charging current 15A
  • High-low voltage protection
  • Against overload, short-circuit Protection
  • Over voltage,battery reverse connection(optional)
  • Under-voltage and over-temperature protection
  • Selectable battery priority or utility priority
  • UPS function and AC charger function
  • Built in 10A/20A/30A solar charge PWM controller
 
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad
Features:
  • Pure sine wave output
  • DSP digital control
  • Boost and buck AVR for voltage stabilization
  • Cold start function
  • Intelligent battery management
  • Short circuit and overload protection
  • Off-mode charging
  • Offering LED and LCD panels for selection
  • Optional USB/RS232/RJ45/SNMP communication port
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad
Features:
  • True Double conversion Technology
  • DSP digital control technology enable UPS more stable performance.
  • Three-level inverter technology
  • Active High input power factor correction technology (PFC)
  • Wide Input Voltage Frequency Range& Strong load capacity
  • Zero power switch delay
  • Compatible with Generators
  • Wide input voltage and frequency range can effectively isolate the harmful waves into power by the generator and provide pure,safe and stable power supply.
  • Support intelligent monitoring
  • Fully support remote intelligent monitoring with flexibility in choice of USB cards . AS400 cards , SNMP cards , RS485 cards
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad
Features:
  • Valve sealed design, no free electrolyte, Maintenance -free
  • Designed floating service life:15 years @ 25 °C/68 °F.
  • Wide operating temperature range from -15°C to 35°C
  • Nanometer gel electrolytes eliminate the acid stratification and prolong cycle life
  • Low self-discharge rate: ≤3%/month.
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Content
Features:
  • Pure sine wave output
  • AC Charging current 15A
  • High-low voltage protection
  • Against overload, short-circuit Protection
  • Over voltage,battery reverse connection(optional)
  • Under-voltage and over-temperature protection
  • Selectable battery priority or utility priority
  • UPS function and AC charger function
  • Built in 10A/20A/30A solar charge PWM controller
 
Applications:
  • Mammogram
  • Ultrasound Equipments
  • Radiology rooms
 
Technical Specifications
MODEL VKS300W VKS500W VKS700W VKS800W VS1000W VKS1200W
Rated Power 300W 500W 700W 800W 1000W 1200W
Peak Power 600W 1000W 1400W 1600W 2000W 2400W
AC input voltage range 73V-135VAC(110VAC/120VAC) 145V-275VAC(220VAC /230VAC )
Input frequency range 45-65HZ
Battery voltage 12VDC /24VDC
DC voltage 12VDC:10.5 -15VDC/24VDC:21-30VDC
Solar Controller 10A/20A/30A
Solar Input 120W 240W 360W 480W 720W
Battery undervoltage alarm 10.5VDC /21VDC
Battery undervoltage protection 10VDC /20VDC
Battery overvoltage protection 17V±0.5V /34V±0.5V
Voltage overvoltage alarm 15V-16VDC/30V-32VDC
Overload protection Rated power of 110% or more
Temperature protection ≥85 °C alarm, ≥90 °C off the machine
Inverter output voltage 110VAC/120VAC/ 220VAC/230VAC ±2%
Inverter output frequency 50/60HZ±10%
Inverter output waveform pure sine wave
AC output voltage range AVR output 110VAC/120VAC/ 220VAC/230VAC ±10%
Output frequency range Automatic tracking
Conversion time <5ms
Cooling method Intelligent fan control, ≤42 °C fan slow working , ≥45 °C fan high working .
AC Charging current 15A
Working mode selection Free to choose(SET) 01: AC priority/Citypower priority: When city power is available, the inverter will work AC output, city power will supply power to appliances.The city power and sun power will charges 2 kinds power to battery. When city power failed,Sun power will charge the battery and  use battery power(Solar power) to take the appliances.02: energy saving mode load power ≤10% off the machine, ≥11% -100% turn on03: Solar power priority/ Battery priority When it have sun power,sun power charges the battery and supply power to the appliances.When it does not have sun power or battery voltage ≤10.5V, inverter will automatic use city power to take the appliances, When battery voltage reach 13V inverter will use battery power and sun power.
External Size(mm) DxWxH 300*290*150mm
Packing Size(mm) DxWxH 350*350*405(2pcs)
Net Weight(KG) 5.5 6.5 7 8 9.5 10
Gross Weight(KG) 13 15 16 18 20 22
Features:
  • OPzV Tubular Gel Battery ( solid-state) 60AH-3000AH
  • Voltage class: 12V/2V
  • Capacity range: 60Ah~3000Ah

OPzV batteries offer high capacity reserve power and true deep cycling performance. With a design life of 20 years and a maintenance-free operation, OPzV battery are perfect for regions with an unstable supply of electricity. OPzV battery are also completely spill-proof, which makes them safe to install anywhere, even in remote environments with minimal supervision.

 
Technical Specifications
Model Nominal Voltage Capacity Dimension Terminal
C10/1.80VPC (Ah) Length Width Height Total Height
(V) mm mm mm mm
OPzV6-200 6 200 322 177.5 226 231 F16(M8) F14(M8)
OPzV12-60 12 60 260 169 211 216  F11(M6)
OPzV12-80 12 80 328 172 215 220  F12(M8)
OPzV12-100 12 100 407 177 225 225  F12(M8)
OPzV12-120 12 120 483 170 241 241  F12(M8)
OPzV12-140 12 140 532 207 214 219  F12(M8)
OPzV12-160 12 160 532 207 214 219 F12(M8)
OPzV12-180 12 180 522 240 219 224  F10(M8)
OPzV12-200 12 200 521 268 220 225 F14(M8)
OPzV2-200 2 200 103 206 355 390 F10(M8)
OPzV2-250 2 250 124 206 355 390 F10(M8)
OPzV2-300 2 300 145 206 355 390 F10(M8)
OPzV2-350 2 350 124 206 470 505 F10(M8)
OPzV2-420 2 420 145 206 470 505 F10(M8)
OPzV2-500 2 490 166 206 470 505 F10(M8)
OPzV2-770 2 770 210 254 470 505 F10(M8)
OPzV2-600 2 600 145 206 645 680 F10(M8)
OPzV2-800 2 800 191 210 645 680 F10(M8)
OPzV2-1000 2 1000 233 210 645 680 F10(M8)
OPzV2-1200 2 1200 276 210 645 680 F10(M8)
OPzV2-1500 2 1500 275 210 795 830 F10(M8)
OPzV2-2000 2 2000 399 214 770 805 F10(M8)
OPzV2-2500 2 2500 487 212 770 805 F10(M8)
OPzV2-3000 2 3000 576 212 770 805 F10(M8)
Features:
  • Pure sine wave output
  • DSP digital control
  • Boost and buck AVR for voltage stabilization
  • Cold start function
  • Intelligent battery management
  • Short circuit and overload protection
  • Off-mode charging
  • Offering LED and LCD panels for selection
  • Optional USB/RS232/RJ45/SNMP communication port
 
Technical Specifications
 
MODEL UPS-AP1K ( L ) UPS-AP2K ( L ) UPS-AP3K ( L )
Capacity 1000VA/700W 2000VA/1400W 3000VA/2100W
INPUT
Voltage range 145~275VAC±5V
Frequency range 50Hz-60Hz
OUTPUT
Output voltage 220VAC
AC voltage range ±10%
Frequency range(batt.mode) 50Hz ± 0.25Hz or 60Hz ± 0.3Hz
Overload 105%-110%: UPS beep alarm, do not shut down.
110%-130%: auto shut down after 30 seconds
> 130%: auto shut down immediately
Transfer time <typical 4ms
Waveform(batt.mode) Pure sine wave
BATTERY
Standard model Battery type 12V7Ah
Numbers 2 4 6
Charging current(Max.) Assume: 1A± 10%; Max: 1A or 2A for option
Charging voltage 27.3VDC±1% 54.7VDC±1% 82.0VDC±1%
Long-run model Battery type 12V, AH depending on applicant
Numbers 3 6 8
Charging current(Max.) > 5A
Charging voltage 27.4VDC±1% 82.1VDC±1% 109.4VDC±1%
PHYSICAL
Standard model Dimension, LxWxH(mm) 360x147x220 440x192x340 440x192x340
Net weight(kgs) 11.9 22 27.9
Long-run model Dimension, LxWxH(mm) 360x147x220 440x192x340 440x192x340
Net weight(kgs) 8.5 16 18.2
ENVIRONMENT
Humidity 20-90%RH @0-40°C (non-condensing)
Noise level Less than 55dBA@1 Meter
MANAGEMENT
Smart RS-232 Support windows 2000/2003/XP/Vista/2008, Windows7/8, Linux, Unix, and MAC
Optional SNMP Power management from SNMP Management and web browser
Features:
  • True Double conversion Technology
  • DSP digital control technology enable UPS more stable performance.
  • Three-level inverter technology
  • Active High input power factor correction technology (PFC)
  • Wide Input Voltage Frequency Range& Strong load capacity
  • Zero power switch delay
  • Compatible with Generators
  • Wide input voltage and frequency range can effectively isolate the harmful waves into power by the generator and provide pure,safe and stable power supply.
  • Support intelligent monitoring
  • Fully support remote intelligent monitoring with flexibility in choice of USB cards . AS400 cards , SNMP cards , RS485 cards
Applications:
  • Mammogram
  • Ultrasound Equipments
  • Radiology rooms
 
Technical Specifications
Model VT1K VT1KL VT2K VT2KL VT3K VT3KL
Rated power 1KVA/900KW 2KVA/1.8KW 3KVA/2.7KW
Input Voltage range 90~285Vac L+N+G
Frequency range 40-70Hz(Adjustable)
Input power factor >0.99
Output Rated voltage and precision 220Vac (1±2% ) L+N+G
Output frequency 46-54Hz Synchronous mains power; 50Hz( Frequency Range 40-46Hz ~54-60Hz);50Hz(Battery mode)
Rated Current 4.5A 9.1A 13.6A
Output power factor 0.9
Output harmonic ≤4%
Crest factor 3:1
Inverter overload capacity 105%±5%< Load<125%±5% : 50s transfer to bypass 125% ±5% < Load<150 % ±5 % : 25s transfer to bypass Load > 150 % ± 5 %: 300s transfer to bypass
Transfer time 0ms
Efficiency ≥85%
Battery Rated voltage 24Vdc 36Vdc 48Vdc 72Vdc 72Vdc 96Vdc
Battery Numbers 2 3 4 6 6 8
Charge current 1A 6.5A 1A 5.5A 1A 5.5A
Size(LXWXH)mm 350*144*230 425*190*328
Net Weight(KG) 9.5kg 6kg 18.5kg 10kg 23.5kg 11kg
Operating temperature 0°C 〜40°C
Operating humidity 20% 〜95%
Noise ≤50dB
Features:
Digital Control All parts of this series of UPS adopt digital control, each performance index of UPS is very excellent, and the control system is morestableand reliable.Each module has built-in automatic bypass switch and corresponding bypass current equalizing inductor, providing good bypass power supply equalization performance. Intelligent Battery Management Users can set the charging current, constant current, constant voltage and floatingcharging modescan be automatically and smoothly switched; Battery voltage can beset ±192Vdc/±240Vdc/±216Vdc/±228Vdc/±240Vdc (32/34/36/38/40 pcs optional) High Power Density Modular Design The capacity of each single module is30kVA, and the height is3U; UPS modulescan be added and removed onlineto achieve zero maintenance time. N+x Parallel Redundancy The quantity of redundant module can be set accordingly, When the redundant module reaches more than 2 hours, the system availability achieves 99.99%, MTBF(Mean Time Between Failures) lasts more than 250,000 hours; Supporting parallel connection between cabinets. A maximum of four cabinets can be parallel,and battery pack can be shared when UPS cabinet in parallel. Touchable LCD Display Screen Super large LCD display with touching function. Standard Cabinet Design The appearance ofthe standard cabinet is beautiful and generous, which can perfectly match the use environment ofthe computer room and save the space.

Safe and Easy to Maintain When an emergency occurs, users can switch to the maintenance bypass to supply power, and maintenance personnel can safely perform online maintenance; Press EPO button to shutdown in emergentsituation, and also have REPO function. Intelligent Management Centralized monitoring module (with hot-swap function), RS232/RS485 communication interface/SNMPcard (optional), can realize remote monitoringof UPS, relay card is optional.

 
Technical Specifications
Model VM 90K VM150K VM300K
Capacity UPS Cabinet 30-90KVA 30-150KVA 30-300KVA
Power Module 30kVA
INPUT Input Form 3P4W+G
Rated Voltage 380/400/415Vac
Voltage Range 207~478Vac
Frequency Range 40~70Hz
Input Power Factor ≥0.99
Bypass Range 380 upper limit: 25% (optional +10%s +15%、+20%) 400 upper limit: 20% (optional +10%、+15%) 415 upper limit: 15% (optional +10%) Lower limit: -45% (optional -20%s -30%) Bypass frequency protection range: ± 10%
Input Current Harmonic Wave ≤3% (100% non-linear)
OUTPUT Output Form 3P4W+G
Rated Voltage 380/400/415Vac
Output Power Factor 0.9 or 1
Voltage Accuracy ±1%
Output Frequency Mains Mode Synchronization with input; when mains frequency exceeds maximum value ±10% (can be set ±1%、 ±2%、±4%、±5%), output frequency 50X(±0.2%)Hz
Battery Mode (50/60±0.2%) Hz
Crest Factor 3:1
Conversion Time Mains mode — bypass mode: 0ms (tracking); Mains mode— battery mode: 0ms
Overload Capacity Load≤110%: 60 mins; Load≤125%: 10 mins; Load≤150%: 1 min; Load≥150%, shutdown immediately
Output Voltage Harmonic Wave ≤2% (100% linear)
Efficiency In normal mode 95%
Communication Port RS232、RS485、 Intelligent Slot*2 、 Dry connect port
BATTERY Battery Voltage ±192Vdc/±204Vdc/±216Vdc/±228Vdc/±240Vdc; (32/34/36/38/40pcs Optional)
Charging Current UPS Cabinet 30A Max 50A Max 100A Max
Power Module 10A Max
Environment Operating Temperature 0〜40°C
Relative Humidity 0-95% (non-condensing)
Storage Temperature -25-55°C (excluded battery)
Altitude < 1500m (derating if exceeding 1500m)
Physical Characteristic Outer Dimension (LxWxH) mm Cabinet 840X600X1400 1100X600X2000
Module 580 X 443 X 131
Weight (Net Weight) KG Cabinet 158 170 305
Module 33.5
Operative Standard YD/T 2165-2010
Features:
  • Valve sealed design, no free electrolyte, Maintenance -free
  • Designed floating service life:15 years @ 25 °C/68 °F.
  • Wide operating temperature range from -15°C to 35°C
  • Nanometer gel electrolytes eliminate the acid stratification and prolong cycle life
  • Low self-discharge rate: ≤3%/month.
 
Application
  • UPS Systems
  • Portable Equipment
  • Renewable Energy Systems
  • Electric Utilities
  • Outdoor control Equipment
  • Railroad Utilities
  • Telecom Systems
 
Technical Specifications
Model Nominal Voltage Capacity Dimension LXWXH (mm) Total Height (mm) Weight (KG/IBS) Terminal
VG12-33 12V 33AH 195 130 167 167 10 22.05 M6
VG12-35 12V 35AH 195 130 167 167 11.5 25.35 M6
VG12-38 12V 38AH 197 165 172 172 12.5 27.56 M6
VG12-40 12V 40AH 197 165 172 172 13.2 29.1 M6
VG12-45 12V 45AH 197 165 172 172 15 33.07 M6
VG12-50 12V 50AH 229 138 205 208 15.5 34.17 M6
VG12-55 12V 55AH 229 138 205 208 16.5 36.38 M6
VG12-65 12V 65AH 350 166 175 175 21 46.3 M8
VG12-70 12V 70AH 260 168 208 211 21.8 48.06 M8
VG12-80 12V 80AH 260 168 208 211 24 52.91 M8
VG12-90 12V 90AH 330 171 216 219 27 59.52 M8
VG12-100 12V 100AH 330 171 216 219 29.5 65.04 M8
VG12-120 12V 120AH 407 173 237 237 35 77.16 M8
VG12-150 12V 150AH 484 170 241 241 45 99.21 M8
VG12-200 12V 200AH 522 240 219 222 61.5 135.58 M8
VG12-250 12V 250AH 520 268 220 223 71 156.53 M8
WeightN/AN/AN/AN/AN/AN/A
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • Rating
  • Price
  • Description
Click outside to hide the comparison bar