Somatics Electroconvulsive Therapy (ECT) Machine

$0.00

Shipped from abroad

The machine provides higher stimulus current, deeper cerebral stimulus penetration, and better seizure generalization. It provides the most effective form of bilateral brief pulse ECT with a 0.5msec pulsewidth that minimizes side-effects and can be delivered at every stimulus dose including the maximum dose with efficient and accurate stimulus titration.

Delivery & Availability:
Typically 21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.

 

SF1033560106-1

Description

The machine provides higher stimulus current, deeper cerebral stimulus penetration, and better seizure generalization. It provides the most effective form of bilateral brief pulse ECT with a 0.5msec pulsewidth that minimizes side-effects and can be delivered at every stimulus dose including the maximum dose with efficient and accurate stimulus titration.

Features-

  • Choose 0.25, 0.3 or 0.5msec Ultrabrief Pulsewidth
  • Genie™ IV EEG Analyzing Software
  • Four (4) – Channel Monitor/Printer
  • Optimal Stimulus Programs
  • Maximum Sustained EEG Amplitude
  • Continuous Digital Heart Rate Monitor
  • Peak Heart Rate Printout
  • EEG Coherence Analysis
  • Seizure Energy Index
  • Postictal Suppression Index
  • Maximum Dose Available at all Pulsewidths
  • Interictal Frontal Delta Analysis
  • Computer EEG Seizure Duration
  • Computer Motor Seizure Duration
  • True EMG Monitor
  • EEG Ictal Line Seizure Indicator
  • Light-Emitting Elapsed Time Display
  • Up to 8 Seconds of Stimulation
  • Change Waveform without Altering Dose
  • Audible EEG™ monitor
  • Instant Impedance Test
  • Extended Seizure Alert
  • Patented Safety Monitor Circuit

ECT Machine with Standard Accessories below:

Article           Qty      Description                                                                          

SYS-IV            1                     Thymatron System IV , with following accessories:

EGEN              1         Genie-IV EEG Analyzing Software

ELDS9            1                     Set with 9 lead wires  (4 red / 4 black / 1 green)

EPAD              10       Disposable ECT treatment electrodes “Thymapad”

(5 Pair)

ECEF-IV        1                     EEG/EMG/ECG-monitoring cable

ECET-IV        1                     ECT-treatment cable

EEDS              50       Pregelled EEG/EMG stick-on electrodes

EMGD           2                     Mouthguard oral protectors, 2 sizes

CP110            2         Z-fold chart paper

EDVD             1         Audio training DVD

EMAE             2         Operating manual English

ESERV           1         Service manual English

For further treatments you can order separately following accessories:

EECU/EEFL – Stainless steel electrode, cupped (EECU) or flat (EEFL)

EHST- Headstrap, latex rubber, perforated

EHAN-Electrode handle, fully shielded, for flat or cupped electrode.

Click Here To Download Catalogue

Reviews(6)

4.33 average based on 6 ratings.
  1. dUt2zK

    342136 758881 very nice post, i definitely adore this web site, keep on it 907556

  2. William Spates

    Purchased Thymatron ECT but need consumable supplies listed below…can you provide a price quote
    Table 1: Equipment List
    Description Quantity
    Disposable Oral Protectors 3
    Mouth Guard oral protector 50
    Mouth Guard oral protector 50
    Thymapad ™ Stimulus Electrodes 2
    Recording Electrodes 3
    Thermal Recording Paper 6
    PreTac™ Solution for use with Thymapad™ Stimulus Electrodes 24
    ECT Treatment Cable – Black 1
    Conductive treatment gel 250 ml/tubes 5
    Treatment Electrode; standard flat stimulus plate 2
    Treatment Electrode with Concave Stimulus Plate 2
    Disposable EEG/EMG/ECG Recording Electrodes; SYSTEM 4 1
    Monitoring Electrode Leads for SYSTEM 4 (4 Red, 4 Black, 1 Green) 5
    Monitoring Electrode Leads for SYSTEM 4 (2 Red, 2 Black, 1 Green) 5
    Monitoring Cable for SYSTEM 4 (Plastic Plug) 1
    Fuse 2 Amp, for all 120 volts Thymatrons 5
    ECTOBRAINT II Testing and Training Device 1

    • samson faluro

      Please send your list to this email info@halomedicals.com

    • Raji Saheed Olanrewaju

      Good day
      I need ect machine
      Can I get the cost & other information needed for its delivery to Nigeria?

      Raji
      rajisaheed2003@gmail.com
      +2348034258404 (WhatsApp & telegram)

  3. J Clealand

    Please provide purchasing information

    This website does not have a proper way to request the price information…

  4. Chijioke

    Please I’ll like to confirm the price of the ECT Machine.

  5. Mel

    Id like to buy one for home. I’m tired of going to the hospital for this. Could you please advise on price?

  6. Lila Gómez

    Need to know about Price and delivery time to Miami
    Thanks

Add a review

Your email address will not be published. Required fields are marked *

Quick Comparison

Somatics Electroconvulsive Therapy (ECT) Machine removeHospital Bed with Column Motors removeApexbio Eclipse A1c Glycoslated Hemoglobin Meter removeMayo Table removeDolphin-XF Transcranial Robotic Probe removeBRAINSWAY Deep TMS H1 Coil remove
NameSomatics Electroconvulsive Therapy (ECT) Machine removeHospital Bed with Column Motors removeApexbio Eclipse A1c Glycoslated Hemoglobin Meter removeMayo Table removeDolphin-XF Transcranial Robotic Probe removeBRAINSWAY Deep TMS H1 Coil remove
ImageLinealife Faultless - 3500 Hospital Bed with Column MotorsApexbio Eclipse A1c Hemoglobin A1c POC AnalyzerLinealife My-20 Mayo Table
SKUSF1033560106-1SF1033560102-1SF1033560105-1SF1033560102-3SF1033560130142-4SF1033560130162-4
Rating
Price

$0.00

$0.00

$0.00

$0.00

$6,270.00

$0.00

Stock
Availability
Add to cart

DescriptionShipped from abroad The machine provides higher stimulus current, deeper cerebral stimulus penetration, and better seizure generalization. It provides the most effective form of bilateral brief pulse ECT with a 0.5msec pulsewidth that minimizes side-effects and can be delivered at every stimulus dose including the maximum dose with efficient and accurate stimulus titration.
Delivery & Availability: Typically 21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.  
Shipped from Abroad
Delivery & Availability: Typically 21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped from Abroad The Eclipse A1c offers a fast and easy way to measure HbA1c in a physician's office setting or long term care facility where speed and convenience counts most. HbA1c can be measured in just 3 simple steps and the result is certified by National Glycohemoglobin Standardization Protocol (NGSP) to ensure accuracy.
Delivery & Availability: Typically 21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.  
Shipped from Abroad
  • Chrome-plated stem
  • Removable tray size: 585mmL x 420mmW x 30mmD
  • Telescopic height adjustment from 945mm to 1250mm
  • 50mm Twin wheel plastic castors
Delivery & Availability: Typically 21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad Proudly introducing the X-Factor in TCD robotic solutions, assisting in obtaining bilateral TCD insonations in as quickly as just a few seconds!. Designed for short and long-term monitoring, for use in anesthesia, in the ICU, or in the TCD lab.
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad
The H1 Coil stimulates the bilateral prefrontal cortex, with a preference for the left dorsolateral prefrontal cortex. In addition to numerous published, double-blind, randomized controlled trials validating the efficacy of Deep TMS for depression, clinical data of over 1,000 patients in real practice settings has shown compelling results. Among patients who completed 30 sessions, approximately 4 out of 5 achieved a clinical response, and approximately 2 out of 3 achieved remission from depression.
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
ContentThe machine provides higher stimulus current, deeper cerebral stimulus penetration, and better seizure generalization. It provides the most effective form of bilateral brief pulse ECT with a 0.5msec pulsewidth that minimizes side-effects and can be delivered at every stimulus dose including the maximum dose with efficient and accurate stimulus titration. Features-
  • Choose 0.25, 0.3 or 0.5msec Ultrabrief Pulsewidth
  • Genie™ IV EEG Analyzing Software
  • Four (4) - Channel Monitor/Printer
  • Optimal Stimulus Programs
  • Maximum Sustained EEG Amplitude
  • Continuous Digital Heart Rate Monitor
  • Peak Heart Rate Printout
  • EEG Coherence Analysis
  • Seizure Energy Index
  • Postictal Suppression Index
  • Maximum Dose Available at all Pulsewidths
  • Interictal Frontal Delta Analysis
  • Computer EEG Seizure Duration
  • Computer Motor Seizure Duration
  • True EMG Monitor
  • EEG Ictal Line Seizure Indicator
  • Light-Emitting Elapsed Time Display
  • Up to 8 Seconds of Stimulation
  • Change Waveform without Altering Dose
  • Audible EEG™ monitor
  • Instant Impedance Test
  • Extended Seizure Alert
  • Patented Safety Monitor Circuit
ECT Machine with Standard Accessories below: Article           Qty      Description                                                                           SYS-IV            1                     Thymatron System IV , with following accessories: EGEN              1         Genie-IV EEG Analyzing Software ELDS9            1                     Set with 9 lead wires  (4 red / 4 black / 1 green) EPAD              10       Disposable ECT treatment electrodes "Thymapad" (5 Pair) ECEF-IV        1                     EEG/EMG/ECG-monitoring cable ECET-IV        1                     ECT-treatment cable EEDS              50       Pregelled EEG/EMG stick-on electrodes EMGD           2                     Mouthguard oral protectors, 2 sizes CP110            2         Z-fold chart paper EDVD             1         Audio training DVD EMAE             2         Operating manual English ESERV           1         Service manual English For further treatments you can order separately following accessories: EECU/EEFL - Stainless steel electrode, cupped (EECU) or flat (EEFL) EHST- Headstrap, latex rubber, perforated EHAN-Electrode handle, fully shielded, for flat or cupped electrode.
Click Here To Download Catalogue
Features: • Electrical operated backrest, height and legrest adjustment. • Electrical operated trendelenburg , reverse trendelenburg, fowler and vasculer position. • Nurse control unit. • Auto-CPR and manuel CPR. • Retracting backrest and legrest. • Hygenic design (PP), lockable and tuck away side rails. • Profile frame with easy removable ABS plastic covers. • Removable head and foot ends. • Central lockable castors. • Electrostatic painted metal frame. • Height adjustable I. V. stand. • Plastic crash bumpers. • Battery backup. • Comprehensive range of accessories avaliable. • Angle gauge for back. • Cardiac chair position with one button. • Shock position with one button. • Bed exit position with one button. • Dual sided control panel on side- rails. • Bed extension position 200 mm. • Linen holder. • Anti-static castor. • Grounding socket. • Distance between side rail and head board max. 58 mm. • Underbed light. • Cable holder. • Twin castors. (O) • Lifting Pole.(O) • Patient handset.(O) Dimensions: • Overall Length: 2160 mm • Overall width:990 mm • Height Range: 480-850 mm • Trendelenburg (Max.): 15 ⁰ • Reverse Trendelenburg (Max.):15⁰ • Backrest Angle (Max.): 78 ⁰ • Legrest Angle (Max.): 34⁰ • Castor diameter: 150 mm • Backrest sliding (Max.):120 mm • Legrest sliding (Max.): 85 mm  The Eclipse A1c offers a fast and easy way to measure HbA1c in a physician's office setting or long term care facility where speed and convenience counts most. HbA1c can be measured in just 3 simple steps and the result is certified by National Glycohemoglobin Standardization Protocol (NGSP) to ensure accuracy.

Key Features

1. Method: Immunoassay
2. Measurement Range (mg/dL): 4-14% HbA1c
3. Sample Volume: 1μL
4. Analysis time: 5 minutes
5. Memory Capacity: 500 tests with date and time
6. Light Source: LED
7. Power supply: Switching power adapter 6V 2A
8. Interface: USB/printer port
9. Precision: CV < 4% (at HbA1c normal range)
10. Size: 236x163x85mm
Content
1. HbA1c reaction strip
2. Test tube with reaction solution
3. Micropipette
Specification: Measurement Range: 4-14% HbA1c Testing Time (seconds): 5 - 6 minutes Sample Volume (μL): >0.5 µL Weight (g) without Batteries: 1200g Memory Capabilities: 250 memory sets with date and time Data Output: Dedicated port for printer, USB and optional barcode scanner Dimension (mm): D248mm x W162mm x H95mm
Click Here To Download Catalogue
Low profile solid steel base finished in grey powder coat. Features:
  • Chrome-plated stem
  • Removable tray size: 585mmL x 420mmW x 30mmD
  • Telescopic height adjustment from 945mm to 1250mm
  • 50mm Twin wheel plastic castors
https://youtu.be/JwSJvUVJrxo?si=6QkpitWAwvZZSwOM  
Description
The Dolphin/XF is a new breakthrough development in TCD robotics. It is designed to assist the user in quickly and automatically insonating and monitoring cerebral blood flow.
Features

Comfortable Headset

The unique Dolphin/XF robot fits the patient’s head with a soft and comfortable dedicated monitoring headset. The patient’s posture is of no limitation, and thus the patient can lay down, be seated, or stand up during the measurements with the robot without any discomfort or preventing factors in the headset.

Ultra Fast Scanning

Use the Fast Scan mode for rapid scanning within seconds. Or use the High-Resolution Scan option for a more detailed robotic search through the temporal or suboccipital windows. This latter option generates a “heat map” as a function of insonated depth, showing all of the identified blood flow velocities flowing either towards the probe or away from the probe. https://youtu.be/QsaSaUbh7as?si=Vky2fSg6Mc3Ft_ob

Ideal Monitoring Solution

The Dolphin/XF TCD robot is ideal for settings where short or long-term monitoring is required. This includes applications in:
  • Anesthesia and the Operating Room (OR),
  • HITS detection for longer-term applications, 
  • Specialty Test protocols such as Vasomotor Reactivity (VMR), Breath Holding or PFO testing for short term monitoring, 
  • Use in the ICU, or 
  • With SAH or Stroke patients where cerebral blood flow monitoring is of particular importance. 
https://youtu.be/b6dDU1mGQ8Q?si=md0GOLuI1mUt6ouv
The BrainsWay Deep TMS H1 Coil is a transcranial magnetic stimulation (TMS) device that's used to treat depression and other mental disorders: 
  • Design
    The H1 Coil is a flexible, soft copper coil that's placed inside a helmet to stimulate the brain. The coil's design allows for a wider and deeper distribution of magnetic fields than traditional TMS coils.
  • Effectiveness
    The H1 Coil is effective in treating depression and has also been explored as a treatment for other conditions:
    • DepressionThe H1 Coil is FDA-cleared to treat major depressive disorder (MDD) in adults who haven't responded well to other antidepressant medications.
    • Other conditionsThe H1 Coil has been explored as a treatment for negative symptoms of schizophrenia, bipolar depression, and migraine.
  • Benefits
    The H1 Coil's design allows for greater neuron activation, which can lead to more effective stimulation and fewer targeting errors.
  • Safety
    The H1 Coil is considered a safe and effective clinical tool.
Features
  • Flexible base
    The H1 coil has a flexible base that can adapt to the shape of the patient's head. 
  • Tangential coil components
    The H1 coil has tangential coil components that are close to the brain targets. 
  • Parallel coil components
    The H1 coil has parallel coil components that direct the electric pulse beams. 
  • Electrical pulses
    The H1 coil has numerous electrical pulses that converge from various directions. 
  • Return paths
    The return paths of the electrical pulses are located at a distance from the target area. 
  • Stimulates the prefrontal cortex
    The H1 coil stimulates the bilateral prefrontal cortex, with a preference for the left dorsolateral prefrontal cortex (DLPFC). 
  • Deeper and broader stimulation
    The H1 coil's patented design enables deeper and broader stimulation than traditional TMS coils.
    Click here to download Brochure
WeightN/AN/AN/AN/AN/AN/A
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • Rating
  • Price
  • Description
Click outside to hide the comparison bar
Compare