/

SonoLong Curl Echo-Echogenic Specialty Catheter-Through-Needle System

$0.00

Shipped From Abroad

The SonoLong Curl Echo set was developed by PAJUNK together with Dr. Cedric Luyet and is especially predestined for Paravertebral blocks. The catheter comes with a curled tip that reduces the chance of catheter migration1. The soft tip of the Curl catheter tip rolls up placing the catheter tip at the needle tip position. The 6 lateral openings allow for a consistent distribution of anesthetic around the nerve.
The SonoLong Curl Echo catheter is visible under ultrasound and is radiopaque.

Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
SF1033560130169-14
Brands:: Pajunk

Description

SonoLong Curl Echo Catheter Features & Advantages

Curl Tip

  • Specialty catheter with curled end closed tip, and six lateral openings
  • Allows for even distribution of local anesthetic around the nerve

Stainless Steel Helical Coil

  • Improved ultrasound visibility
  • Improved catheter flexibility and stability resulting in reduced chance of kinking6
  • Radiopaque

Depth Markings

  • Graduation on the first 30cm
  • Easy determination of catheter positioning
  • Easy to read and identify

Outlet Markings

  • (1) 10mm marking – catheter is exiting the needle tip
  • (2) The catheter tip is completely curled up
SonoLong Curl Echo Needle Features & Advantages

Echogenic Needle Tip

  • Improves needle tip visibility under ultrasound

Cornerstone Reflectors

360° graduations on the first 20 mm of the needle in two sections:

  • Optimized ultrasound visibility of the needle shaft1.
  • Reliable and optimized needle echogenicity at higher insertion angles.

NanoLine® Coating

  • Very thin polymer film on inner and outer needle surface
  • Excellent puncture and gliding properties through smooth surface
  • Precise stimulation through the non-insulated needle tip

Depth Graduations

  • Easy to read and identify

Click here to download Brochure

Reviews

There are no reviews yet.

Be the first to review “SonoLong Curl Echo-Echogenic Specialty Catheter-Through-Needle System”

Your email address will not be published. Required fields are marked *

Quick Comparison

SettingsSonoLong Curl Echo-Echogenic Specialty Catheter-Through-Needle System removeGuedel Oropharyngeal Airway removeComplete Oxygen Cylinder with Accessories removeSpirometer Paper removePatella Hammer removePlastic Fetoscope remove
NameSonoLong Curl Echo-Echogenic Specialty Catheter-Through-Needle System removeGuedel Oropharyngeal Airway removeComplete Oxygen Cylinder with Accessories removeSpirometer Paper removePatella Hammer removePlastic Fetoscope remove
Image
SKUSF1033560130169-14SF1033560084-47SF1033560084-60SF1033560084-11SF1033560084-110SF1033560084-100
Rating
Price

$0.00

$1.00

$59.00

$12.20

$2.50

$4.20

Stock
Availability
Add to cart

DescriptionShipped From Abroad The SonoLong Curl Echo set was developed by PAJUNK together with Dr. Cedric Luyet and is especially predestined for Paravertebral blocks. The catheter comes with a curled tip that reduces the chance of catheter migration1. The soft tip of the Curl catheter tip rolls up placing the catheter tip at the needle tip position. The 6 lateral openings allow for a consistent distribution of anesthetic around the nerve. The SonoLong Curl Echo catheter is visible under ultrasound and is radiopaque.
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock Guedel Oropharyngeal Airway: This is used to create an air passage way between the mouth and the posterior pharyngeal wall. Useful when the tongue and/or epiglottis fall back against the posterior pharynx in anesthetized or unconscious patients obstructing the flow of air.
Delivery & Availability: Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In Stock Oxygen Cylinder with Safety Cover Delivery & Availability: Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.In Stock
  • Spirometer cardboard paper mouth piece are suitable for use with the  spirometer.
  • Significantly reduces the risk of cross-infection between patients.
  • Essential Spirometry Consumables.
  • The mouthpiece used in spirometric testing may vary from instrument to instrument.
  • It is essential that the patient puts it between the teeth with the lips around it, so that the air can pass freely and the mouthpiece is sealed firmly by the lips.
  • Dentures are best left in place because they provide essential support to cheeks and lips; however, if they fit poorly and obstruct airflow during the maneuvers it is better to remove them from the mouth.
Delivery & Availability: Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock
  • Suited for eliciting a full range of reflexes.
  • Tapered handle base to enable plantar reflex testing.
  • Nylon plastic handle. Black rubber head. PVC bumper ring.
  • A reflex/patella hammer is used by medical professionals to test tendon reflexes in order to detect abnormalities in the central or peripheral nervous system.
Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock A practical way to reduce the exposure of pregnant women to ultrasound - listen to the baby''s heartbeat with Pinard Stethoscope, part of the midwife''s basic equipment. Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Content
SonoLong Curl Echo Catheter Features & Advantages

Curl Tip

  • Specialty catheter with curled end closed tip, and six lateral openings
  • Allows for even distribution of local anesthetic around the nerve

Stainless Steel Helical Coil

  • Improved ultrasound visibility
  • Improved catheter flexibility and stability resulting in reduced chance of kinking6
  • Radiopaque

Depth Markings

  • Graduation on the first 30cm
  • Easy determination of catheter positioning
  • Easy to read and identify
Outlet Markings
  • (1) 10mm marking - catheter is exiting the needle tip
  • (2) The catheter tip is completely curled up
SonoLong Curl Echo Needle Features & Advantages

Echogenic Needle Tip

  • Improves needle tip visibility under ultrasound

Cornerstone Reflectors

360° graduations on the first 20 mm of the needle in two sections:
  • Optimized ultrasound visibility of the needle shaft1.
  • Reliable and optimized needle echogenicity at higher insertion angles.

NanoLine® Coating

  • Very thin polymer film on inner and outer needle surface
  • Excellent puncture and gliding properties through smooth surface
  • Precise stimulation through the non-insulated needle tip

Depth Graduations

  • Easy to read and identify

Click here to download Brochure

Guedel Oropharyngeal Airway: This is used to create an air passage way between the mouth and the posterior pharyngeal wall. Useful when the tongue and/or epiglottis fall back against the posterior pharynx in anesthetized or unconscious patients obstructing the flow of air. Technical Specifications:
Material Non-toxic polyethylene
Sizes #000#00#0#1#2#3#4#5#6
Length 40mm/50mm/60mm/70mm/80mm/90mm/100mm/110mm/120mm
Feature Available with both Guedel type and Berman type
Color-code Pink/Blue/Black/White/Green/Yellow/Red/Light blue/Orange
Packing 1pc/pe bag, 50pcs/box, 500pcs/ctn
Sterile EO gas
Certificate CE/ISO/FDA
     
 
 
Oxygen Cylinder with Safety Cover
  • Spirometer cardboard paper mouth piece are suitable for use with the  spirometer.
  • Significantly reduces the risk of cross-infection between patients.
  • Essential Spirometry Consumables.
  • The mouthpiece used in spirometric testing may vary from instrument to instrument.
  • It is essential that the patient puts it between the teeth with the lips around it, so that the air can pass freely and the mouthpiece is sealed firmly by the lips.
  • Dentures are best left in place because they provide essential support to cheeks and lips; however, if they fit poorly and obstruct airflow during the maneuvers it is better to remove them from the mouth.
     
  • Suited for eliciting a full range of reflexes.
  • Tapered handle base to enable plantar reflex testing.
  • Nylon plastic handle. Black rubber head. PVC bumper ring.
  • A reflex/patella hammer is used by medical professionals to test tendon reflexes in order to detect abnormalities in the central or peripheral nervous system.
A practical way to reduce the exposure of pregnant women to ultrasound - listen to the baby''s heartbeat with Pinard Stethoscope, part of the midwife''s basic equipment. Advantages:
  • You are hearing this baby''s heart beating with your own ears and not the ultrasound Doppler effect converted by technology back into sound. What you are hearing is direct; it is not computed or averaged by a hand-held Doppler or a CTG.
  • Several people do not wish any ultrasound to be used, unless there is a clear indication 3) Much more economical than other conventional alternatives.
WeightN/AN/AN/AN/AN/AN/A
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • Rating
  • Price
  • Description
Click outside to hide the comparison bar
Compare