/

SonoLong SoftSecure-Catheter Placement for Peripheral Nerve Blocks

$0.00

Shipped From Abroad

Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
SF1033560130169-13
Brands:: Pajunk

Description

Clinical Requirements – Precision in Catheter Placement

Precise and permanent placement of the catheter is of crucial importance for reliable performance of peripheral nerve blocks. Marhofer et al.1 have analyzed the causes and consequences of catheter misplacement in detail. Among other things, they found a highly significant correlation between dwell time and dislocation rate of the catheter for interscalene and femoral nerves.

Primary dislocation
If the catheter is pushed further through the nerve, the anesthetic not only misses its target area, but serious complications such as injury to nerve structures and blood vessels can also occur.

Secondary dislocation
Early mobilization of patients also carries the risk of catheter migration. This can damage vessels or nerves and the effectiveness of regional anesthesia cannot be guaranteed.

Relevance of the Catheter Material – Atraumatic, Flexible Catheter Tip

An important starting point for reducing the dislocation rate is the quality of the catheter tip. In 2012, Shih et al. found a direct correlation between the stiffness of the catheter material and the dislocation rate during epidural block.2

This is exactly where the PAJUNK® development started off from. The result is the SonoLong SoftSecure catheter, which is characterized by a soft catheter material and is equipped with a stylet, a stainless steel spiral, and three lateral openings.

The soft tip of the SonoLong SoftSecure catheter ensures precise placement, as the tip is deflected away from the nerve wall due to the wall’s resistance.

For the same reason, the catheter is also held back by the surrounding, firmer structures of the fascia and rolls up in the immediate vicinity. Further advancement of the catheter and subsequent dislocation during patient mobilization should be avoided.

SonoLong SoftSecure Catheter Features & Advantages

Soft Catheter Material

Makes the tip soft and flexible:

  • Designed to minimize the primary and secondary dislocation rates.
  • Injury to nerve structures and blood vessels can be prevented from occurring.

Markings and Graduations

Outlet markings for the SonoLong needle 50 mm, 100 mm, 150 mm, and six ascending 360° markings in 5 cm increments up to 30 cm:

  • Indicate where the catheter tip exits the needle.
  • Support easy control of catheter position.

Catheter Container with Integrated Insertion Aid

Supports one-handed catheter insertion through the needle and tactile perception:

  • Catheter placement is possible under sterile conditions since the catheter is protected by the catheter container.
  • Memory effect can be avoided.

Three Lateral Openings

Arranged around the first 1.1 cm, the tip is closed:

  • Optimize even distribution of the anesthetic.

Stylet Ensures Stability

Stylet is set back 5 cm from the distal end:

  • Supports convenient and secure placement.
  • The soft catheter tip maintains its atraumatic properties.

Integrated Stainless Steel Helical Coil

Ensures kink resistance and flexibility, and a stable inner lumen3.

  • Enables a high anesthetic flow rate
  • and a smooth connection to the injection pump.
SonoLong NanoLine® Needle Features & Advantages

Cornerstone Reflectors

360° graduations on the first 20 mm of the needle in two sections:

  • Optimized ultrasound visibility of the needle shaft4.
  • Reliable and optimized needle echogenicity at higher insertion angles.

NanoLine Coating

Ultra-thin polymer layer in the inner and outer lumen:

  • Increased stimulation precision only through the non-insulated needle tip.

Click here to download Brochure

Reviews

There are no reviews yet.

Be the first to review “SonoLong SoftSecure-Catheter Placement for Peripheral Nerve Blocks”

Your email address will not be published. Required fields are marked *

Quick Comparison

SettingsSonoLong SoftSecure-Catheter Placement for Peripheral Nerve Blocks removeDiscover 14 Panel Cup with Adulterants Per Pack removeDigital Clinical Thermometer removeAmbu Oval Silicone resuscitator (Ambu Bag) removeSpirometer Paper removePatella Hammer remove
NameSonoLong SoftSecure-Catheter Placement for Peripheral Nerve Blocks removeDiscover 14 Panel Cup with Adulterants Per Pack removeDigital Clinical Thermometer removeAmbu Oval Silicone resuscitator (Ambu Bag) removeSpirometer Paper removePatella Hammer remove
ImageDrug Test Cup
SKUSF1033560130169-13SF1033560084-28SF1033560084-115SF1033560084-62SF1033560084-11SF1033560084-110
Rating
Price

$0.00

$0.00

$2.00

$27.00

$12.20

$2.50

Stock

In stock

AvailabilityIn stock
Add to cart

DescriptionShipped From Abroad
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock
The Discover Cup is an all-in-one drug of abuse test cup. The strips are self contained and the entire cup is tamper resistant. Delivery & Availability:
Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock
This features small physical size and low mass, and the LCD digital display provides a rapid, unambiguous readout. An audible tone indicates completion of the measuring period and automatic switch-off takes place after ten minutes to conserve battery life. Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In Stock The Ambu Oval Silicone resuscitator is designed for manual ventilation of neonates though to adults. Delivery & Availability: Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.In Stock
  • Spirometer cardboard paper mouth piece are suitable for use with the  spirometer.
  • Significantly reduces the risk of cross-infection between patients.
  • Essential Spirometry Consumables.
  • The mouthpiece used in spirometric testing may vary from instrument to instrument.
  • It is essential that the patient puts it between the teeth with the lips around it, so that the air can pass freely and the mouthpiece is sealed firmly by the lips.
  • Dentures are best left in place because they provide essential support to cheeks and lips; however, if they fit poorly and obstruct airflow during the maneuvers it is better to remove them from the mouth.
Delivery & Availability: Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock
  • Suited for eliciting a full range of reflexes.
  • Tapered handle base to enable plantar reflex testing.
  • Nylon plastic handle. Black rubber head. PVC bumper ring.
  • A reflex/patella hammer is used by medical professionals to test tendon reflexes in order to detect abnormalities in the central or peripheral nervous system.
Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Content
Clinical Requirements - Precision in Catheter Placement
Precise and permanent placement of the catheter is of crucial importance for reliable performance of peripheral nerve blocks. Marhofer et al.1 have analyzed the causes and consequences of catheter misplacement in detail. Among other things, they found a highly significant correlation between dwell time and dislocation rate of the catheter for interscalene and femoral nerves. Primary dislocation If the catheter is pushed further through the nerve, the anesthetic not only misses its target area, but serious complications such as injury to nerve structures and blood vessels can also occur. Secondary dislocation Early mobilization of patients also carries the risk of catheter migration. This can damage vessels or nerves and the effectiveness of regional anesthesia cannot be guaranteed.
Relevance of the Catheter Material - Atraumatic, Flexible Catheter Tip
An important starting point for reducing the dislocation rate is the quality of the catheter tip. In 2012, Shih et al. found a direct correlation between the stiffness of the catheter material and the dislocation rate during epidural block.2 This is exactly where the PAJUNK® development started off from. The result is the SonoLong SoftSecure catheter, which is characterized by a soft catheter material and is equipped with a stylet, a stainless steel spiral, and three lateral openings. The soft tip of the SonoLong SoftSecure catheter ensures precise placement, as the tip is deflected away from the nerve wall due to the wall's resistance. For the same reason, the catheter is also held back by the surrounding, firmer structures of the fascia and rolls up in the immediate vicinity. Further advancement of the catheter and subsequent dislocation during patient mobilization should be avoided.
SonoLong SoftSecure Catheter Features & Advantages

Soft Catheter Material

Makes the tip soft and flexible:
  • Designed to minimize the primary and secondary dislocation rates.
  • Injury to nerve structures and blood vessels can be prevented from occurring.

Markings and Graduations

Outlet markings for the SonoLong needle 50 mm, 100 mm, 150 mm, and six ascending 360° markings in 5 cm increments up to 30 cm:
  • Indicate where the catheter tip exits the needle.
  • Support easy control of catheter position.
Catheter Container with Integrated Insertion Aid
Supports one-handed catheter insertion through the needle and tactile perception:
  • Catheter placement is possible under sterile conditions since the catheter is protected by the catheter container.
  • Memory effect can be avoided.
Three Lateral Openings
Arranged around the first 1.1 cm, the tip is closed:
  • Optimize even distribution of the anesthetic.

Stylet Ensures Stability

Stylet is set back 5 cm from the distal end:
  • Supports convenient and secure placement.
  • The soft catheter tip maintains its atraumatic properties.
Integrated Stainless Steel Helical Coil
Ensures kink resistance and flexibility, and a stable inner lumen3.
  • Enables a high anesthetic flow rate
  • and a smooth connection to the injection pump.
SonoLong NanoLine® Needle Features & Advantages
Cornerstone Reflectors
360° graduations on the first 20 mm of the needle in two sections:
  • Optimized ultrasound visibility of the needle shaft4.
  • Reliable and optimized needle echogenicity at higher insertion angles.
NanoLine Coating
Ultra-thin polymer layer in the inner and outer lumen:
  • Increased stimulation precision only through the non-insulated needle tip.

Click here to download Brochure

All-in-One Design
FDA 510(K) & CLIA Waived Up to 99% accuracy rate Results in as little as 1 minute 24 Month Shelf Life from Date of Manufacture Secure, seal and send to lab for confirmation Built in temperature strip Available to test up to 17 substances with adulterants or 18 without adulterants Adulterants available
 
 
This features small physical size and low mass, and the LCD digital display provides a rapid, unambiguous readout. An audible tone indicates completion of the measuring period and automatic switch-off takes place after ten minutes to conserve battery life.
  • Measurement range: 32.0 to 43.0°C
  • Accuracy: ± 0.1°C
  • Sensor: Thermistor
  • Readout: Three digit LCD with indication of out-of-range high or low temperature and low battery
  • Sampling rate: Two per second
  • Power source: Silver oxide cell type SR41W or equivalent giving 200 hours life (three years of normal use approx)
  • Power switch: Manual on/off button
  • Automatic switch-off: Ten minutes after last indication
  • Dimensions: L130 x W18 x H9mm overall
  • Probe tip diameter: 3mm
  • Mass: 7g
  • Supplied fitted with silver oxide cell SR41W.
The Ambu Oval Silicone resuscitator is designed for manual ventilation of neonates though to adults. Features
  • The Ambu Oval Silicone resuscitator has a special textured surface combined with the unique support strap to ensures that a comfortable and firm grip is guaranteed, allowing for effective ventilation over extended periods, without the problem of hand fatigue.
  • The Ambu Oval Silicone Resuscitators is made out of a view parts that can be disassembled easily. The Ambu Oval Silicone Resuscitator can easy be cleaned and autoclaved (except the oxygen reservoir) at a temperature of 134° Celsius.
  • The unique shape is small and easy to hold. The ergonomic, lightweight design of Ambu Oval Silicone Resuscitator is made for optimal user handling and support even during extended ventilations.
  • The resuscitators are semi-transparent allowing for a visual check of the patient’s condition. A pressure limitation valve is optional for the adult version and has been included into the design of the pediatric versions to ensure the safety of the patient*.

* International guidelines recommend that all manual resuscitators for infant and pediatric patients should be equipped with a pressure limitation mechanism so the airway pressure does not exceed 45 cm H2O.

  • Spirometer cardboard paper mouth piece are suitable for use with the  spirometer.
  • Significantly reduces the risk of cross-infection between patients.
  • Essential Spirometry Consumables.
  • The mouthpiece used in spirometric testing may vary from instrument to instrument.
  • It is essential that the patient puts it between the teeth with the lips around it, so that the air can pass freely and the mouthpiece is sealed firmly by the lips.
  • Dentures are best left in place because they provide essential support to cheeks and lips; however, if they fit poorly and obstruct airflow during the maneuvers it is better to remove them from the mouth.
     
  • Suited for eliciting a full range of reflexes.
  • Tapered handle base to enable plantar reflex testing.
  • Nylon plastic handle. Black rubber head. PVC bumper ring.
  • A reflex/patella hammer is used by medical professionals to test tendon reflexes in order to detect abnormalities in the central or peripheral nervous system.
WeightN/AN/AN/AN/AN/AN/A
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • Rating
  • Price
  • Description
Click outside to hide the comparison bar
Compare