SPROTTE-Needles for Atraumatic Spinal Anaesthesia
$4.20
Shipped From Abroad
With the introduction of the first atraumatic Sprotte needle at the end of the 1970s, spinal anesthesia was rehabilitated as a fully accepted alternative to general anesthesia. A unique tip design is the secret of its success. Sprotte ́s atraumatic puncture and optimal gliding properties minimize possible injuries and prevent foreign bodies and tissue particles from being carried into the subarachnoid space while reducing the incidence of post-dural puncture headache (PDPH).
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Description
Features & Advantages
Atraumatic Tip Design
- The ogive shaped tip significantly reduces the risk of PDPH and the rounded edges of the lateral eye minimise trauma to the dura mater
- Minimises chance of PDPH3
- Consistent tactile feedback
Lateral Eye
- Burr-free rounded atraumatic edges
- Optimized gliding properties
- Minimum chance of tissue coring and carry-over into the subarachnoid space
Highest Processing Quality
- High-quality stainless steel needle for increased stability
- Smoothly polished and burr-free surface and inner lumen designed for optimized gliding properties and CSF backflow
- Consistent feel and reliable performance
Optimal Lateral Eye Size and Placement
- Unobstructed backflow, even if the eye is partially blocked by the arachnoid membrane
- Allows for quicker CSF flashback
Precision-Ground Metal Stylet
- Lateral eye closes precisely to minimize chance of tissue coring2
- Polished, rounded tip prevents abrasion on the inner needle tube
Standard Hub
- Designed for rapid detection of even the smallest quantities of CSF
- Reduced inner space
Magnifying Hub
- Clear, magnifying needle hub allows for easy visualization of blood or CSF
- Easier detection of CSF flashback
Color-coded Needle Hub with Size Indication
- Easy identification of needle size
Introducer with Facet Tip
- Diameter and length perfectly matched to each spinal needle size
- Minimal reduction of useable working length of the spinal needle
- Funnel-shaped hub to reduce the chance of spinal needle tip damage during insertion
Portfolio Excellence
- Wide needle range with different diameters and lengths
- Special designs for pediatrics and obese patients
Quick Comparison
Settings | SPROTTE-Needles for Atraumatic Spinal Anaesthesia remove | Guedel Oropharyngeal Airway remove | Foyomed Nasal Oxygen Cannula remove | Ambu Oval Silicone resuscitator (Ambu Bag) remove | FlowMir Disposable Turbine with Cardboard Mouthpiece remove | Couch Cover remove | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Name | SPROTTE-Needles for Atraumatic Spinal Anaesthesia remove | Guedel Oropharyngeal Airway remove | Foyomed Nasal Oxygen Cannula remove | Ambu Oval Silicone resuscitator (Ambu Bag) remove | FlowMir Disposable Turbine with Cardboard Mouthpiece remove | Couch Cover remove | ||||||||||||||||
Image | ![]() | ![]() | ![]() | ![]() | ![]() | ![]() | ||||||||||||||||
SKU | SF1033560084-47 | SF1033560084-24 | SF1033560084-62 | SF1033560084-22 | SF1033560084-66 | |||||||||||||||||
Rating | ||||||||||||||||||||||
Price | $4.20 | $1.00 | $1.30 | $27.00 | $145.00 | $8.50 | ||||||||||||||||
Stock | In stock | |||||||||||||||||||||
Availability | In stock | |||||||||||||||||||||
Add to cart | ||||||||||||||||||||||
Description | Shipped From Abroad
With the introduction of the first atraumatic Sprotte needle at the end of the 1970s, spinal anesthesia was rehabilitated as a fully accepted alternative to general anesthesia. A unique tip design is the secret of its success. Sprotte ́s atraumatic puncture and optimal gliding properties minimize possible injuries and prevent foreign bodies and tissue particles from being carried into the subarachnoid space while reducing the incidence of post-dural puncture headache (PDPH).
Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| In stock Guedel Oropharyngeal Airway: This is used to create an air passage way between the mouth and the posterior pharyngeal wall. Useful when the tongue and/or epiglottis fall back against the posterior pharynx in anesthetized or unconscious patients obstructing the flow of air. Delivery & Availability: Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | In Stock Foyomed Nasal Oxygen Cannula: The nasal cannula are used for patients needing only low-flow supplemental oxygen. Patients with breathing difficulties and conditions such as emphysema or other pulmonary pathologies require the nasal cannula. The flow rate for the cannula is around .5 to 4 liters per minute (LPM). All materials used in construction of the Oxygen Mask ,and the Oxygen Tubing are latex free, soft and smooth surface without sharp edge and object, They have no undesirable effects on the Oxygen/Medication passing through under ordinary conditions of use. Mask Material are hypoallergenic and shall resist ignition and rapid buring. Delivery & Availability: Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | In Stock The Ambu Oval Silicone resuscitator is designed for manual ventilation of neonates though to adults. Delivery & Availability: Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | In stock Spirometry testing requires maximum accuracy and hygiene. Each Flowmir disposable turbine, which includes a cardboard mouthpiece, has been individually factory calibrated with a computerized system and it is packaged individually. FlowMIR® is an inexpensive alternative to a costly reusable flowmeter and replaces the need for an antibacterial filter Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | In stock Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | ||||||||||||||||
Content | Features & AdvantagesAtraumatic Tip Design
Lateral Eye
Highest Processing Quality
Optimal Lateral Eye Size and Placement
Precision-Ground Metal Stylet
Standard Hub
Magnifying Hub
Color-coded Needle Hub with Size Indication
Introducer with Facet Tip
Portfolio Excellence
| Guedel Oropharyngeal Airway: This is used to create an air passage way between the mouth and the posterior pharyngeal wall. Useful when the tongue and/or epiglottis fall back against the posterior pharynx in anesthetized or unconscious patients obstructing the flow of air.
Technical Specifications:
| Foyomed Nasal Oxygen Cannula: The nasal cannula are used for patients needing only low-flow supplemental oxygen. Patients with breathing difficulties and conditions such as emphysema or other pulmonary pathologies require the nasal cannula. The flow rate for the cannula is around .5 to 4 liters per minute (LPM). All materials used in construction of the Oxygen Mask ,and the Oxygen Tubing are latex free, soft and smooth surface without sharp edge and object, They have no undesirable effects on the Oxygen/Medication passing through under ordinary conditions of use. Mask Material are hypoallergenic and shall resist ignition and rapid buring.
Features:
| The Ambu Oval Silicone resuscitator is designed for manual ventilation of neonates though to adults.
Features
* International guidelines recommend that all manual resuscitators for infant and pediatric patients should be equipped with a pressure limitation mechanism so the airway pressure does not exceed 45 cm H2O. |
| |||||||||||||||||
Weight | N/A | N/A | N/A | N/A | N/A | N/A | ||||||||||||||||
Dimensions | N/A | N/A | N/A | N/A | N/A | N/A | ||||||||||||||||
Additional information |
Reviews
There are no reviews yet.