Description | In stock
Features:
- Extra-wide tops
- Chrome-plated, reinforced base
- Dimensions: Top & Bottom step - 17.25in H x 17.25in W x 26.50in L
- Weight capacity: 600 lbs.
- Skid resistant rubber mat for safety
Manufacturer warranty: 5 years
Delivery & Availability:
Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | In stock
No of Wheel |
4 |
Usage |
Hospital |
Cloth Material |
Synthetic |
Pole Material |
Aluminium / SS |
Delivery & Availability:
Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | In stock
Delivery & Availability:
Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | In stock
Used for Clinical Diagnostics.
Delivery & Availability:
Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | Shipped From Abroad
The product is mainly suitable for solid medical waste (including pollution), waste plastic and rubber etc,at high temperatures they can be divided into organic compounds. We can offer all kinds of waste incinerator for industrial waste, medical waste, chemical waste and daily waste at any capacity.
Delivery & Availability:
Typically 60 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | In stock
Product name |
Wash-hand stand |
Model |
BC316-2 |
Size |
660*320*810mm |
Bowl qty |
double |
Delivery & Availability:
Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. |
Content | Features:
- Extra-wide tops
- Chrome-plated, reinforced base
- Dimensions: Top & Bottom step - 17.25in H x 17.25in W x 26.50in L
- Weight capacity: 600 lbs.
- Skid resistant rubber mat for safety
Manufacturer warranty: 5 years |
No of Wheel |
4 |
Usage |
Hospital |
Cloth Material |
Synthetic |
Pole Material |
Aluminium / SS |
| | Used for Clinical Diagnostics.
- Test Method: Dry Strip color-developing method
- Test Principle: Dual wavelength reflectance photometry
- Light Source: Cold Lamp with high brightness and long lifetime
- Test System: Color-indentify system with high sensitivity and repeatability
- Wavelength: 520nm, 640nm, 660nm
- Throughput: 120 Strips/Hour
- Test Mode: Single and continuous test mode are selectable
- Test Slot: Using sliding Slot, Easy to clean and replace, lower the carryover
- Waste Collection: Waste urine and waste strips can be collected automatically
- Test Strip: Use GENIUS original strips only
- Display: LCD with high brightness and resolution
- Language: Customizable language software
- Memory: Save 2000 samples results, and auto recover the results when power off during working
- Interface: RS-232 serial port, can be connected to external printer and computer Printer: Inner thermal printer, can be connected to external printer
- Report format: Half quantitative and qualitative, report the color and turbidity is available
- Result unit: SI unit and routine unit are selectable
- Status Check: Auto-check the status during power on and off, auto-indentify the alarm
- Working Environment: Temperature10℃~30℃; Humidity: 20%RH~80%RH
- Power: 100-240V, Auto adapt according to the input voltage
- Consumption: ≤80VA
- Quality System: Certified by TUV and CMD
| LDF series waste incinerator adopt gasification combustion that can make garbage more sufficient burning. Waste incinerator is a kind of machine that possess the own intellectual property, features unique and advanced merits with compact size, high burning efficiency, reasonable burning technology, high degree of non-harm etc, it is an ideal choice for waste treatment of hospital, hotels, various stations and industries.
Features:
- Both gas-motivated and oil-motivated are all can be preferred according to customers' needs.
- Gasified incineration is used for burning syringe, paper waste, bandage, absorbent cotton and other medical wastes.
- Daily waste can be burned once by gasified incineration.
- Gasified incineration, mixed incineration and burnout treatment ensures low emission standard of dust (lower than International standard).
- Totally enclosed operation is suitable for treating infectious waste to avoid secondary pollution.
Advantages:
- Long lifetime
- Totally enclosed operation
- Suitable for treating infectious waste
- Avoid secondary pollution
- Simple operation
- Smokeless and no harmful to environment
- Continuously and fully burning
- Simple operation
Incinerator LDF-100 Parameter:
Applicable hospital size |
250 beds |
Max. Burning Ability |
100 kg/time |
Size of the Burner |
1.5m×1.15m×3m |
Volume of the Burner |
Gasification room 0.5m3 |
second buming room 0.3m3 |
Chamber Temperature |
First chamber:600℃-700℃; |
second chamber:300℃-1300℃ |
|
Ash residue |
≤5% |
Size of the filling entrance |
620mm×800mm |
Chimney |
Hight 10m,Out-radiusØ300 |
Blower |
0.37kw |
Auxiliary machine |
Power0.11kw,fuel consumption4-10kg/h |
Re-burning machine |
Power0.11kw,fuel consumption6-10kg/h |
Running voltage |
220V or 380V |
Weight |
About 4600(kg) |
Flue&Gas Emission Standards:
OrdinalNumber |
Refuse name |
Measuring unit |
GB18484-2001 |
1 |
Blackness of Flue |
Ringelmann class |
1 |
|
|
|
Gas |
|
|
|
2 |
Smoke&Dust |
mg/m3 |
100 |
|
3 |
CO |
mg/m3 |
100 |
|
4 |
SO2 |
mg/m3 |
400 |
|
5 |
HF |
mg/m3 |
9.0 |
|
6 |
HCL |
mg/m3 |
100 |
|
7 |
NO2 |
mg/m3 |
500 |
Click Here To Download Catalogue |
Product name |
Wash-hand stand |
Model |
BC316-2 |
Size |
660*320*810mm |
Bowl qty |
double |
|
Reviews
There are no reviews yet.