Sugentech Inclix HbA1c Test Kit

$0.00

Shipped From Abroad

INCLIX™ HbA1c quantitatively measures HemoglobinA1c(HbA1c) concentration in whole blood using the INCLIX™ analyzer. For in vitro diagnostic use only.

Delivery & Availability:
Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.

SF1033560084-228
Brands:: Sugentech
Brands

Description

  • INCLIX™ HbA1c quantitatively measures HemoglobinA1c(HbA1c) concentration in whole blood using the INCLIX™ analyzer. For in vitro diagnostic use only.
  • Hemoglobin A1c (glycated hemoglobin; HbA1c; A1c) test is the immunochromatography assay and intends for the quantitative determination of stable HbA1c in human blood. In this test system, HbA1c level is expressed in a percent as a good indicator to manage long-term glucose control in diabetes.
  • The HbA1c Test is the immunochromatography method to determine the percentage of glycated HbA1c in human blood. The detector antibody conjugated with colloidal gold can bind to HbA1c in human blood at conjugate pad where it dried. The detector antibody and HbA1c complex flows through membrane to where capture antibody for total hemoglobin immobilized at membrane of the strip. The signal intensity is measured with the INCLIX™ analyzer and the signal reflectance is calculated and shown as a percentage of concentration with established standard with known the percentage of HbA1c in blood samples.

Reviews(3)

0 average based on 0 ratings.
  1. webpage dailymacho.com

    This is a great blog.

  2. look at this site thelegaltorts.com

    This is a great blog.

  3. Read Full Report trading-u.com

    Amazin!

Add a review

Your email address will not be published. Required fields are marked *

Quick Comparison

SettingsSugentech Inclix HbA1c Test Kit removeSugentech Inclix (POCT) Immunoassay Analyzer removeiSED Fully Automated ESR Analyzer removeEppendorf Pipette Tip 20ul Per Pack removeAlcohol Pad Per Pack removeAvalun LabPad Device remove
NameSugentech Inclix HbA1c Test Kit removeSugentech Inclix (POCT) Immunoassay Analyzer removeiSED Fully Automated ESR Analyzer removeEppendorf Pipette Tip 20ul Per Pack removeAlcohol Pad Per Pack removeAvalun LabPad Device remove
ImageInclix HbA1c Test KitEppendorf Pipette Tip 20ul Per PackAvalun Labpad machine
SKUSF1033560084-228SF1033560084-89SF1033560084-129SF1033560084-136SF1033560084-64SF1033560084-65
Rating
Price

$0.00

$0.00

$0.00

$0.00

$4.25

$0.00

Stock
Availability
Add to cart

DescriptionShipped From Abroad INCLIX™ HbA1c quantitatively measures HemoglobinA1c(HbA1c) concentration in whole blood using the INCLIX™ analyzer. For in vitro diagnostic use only.
Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock INCLIX™ is an immunochromatographic analyzer providing immediate point-of-care testing (POCT) at patient care settings or clinical laboratories. It facilitates automatic detection of various biomarkers for cardiovascular disease, infectious disease, cancer, diabetes, allergy, and etc. with high accuracy and sensitivity. INCLIX™ analyzer is a compact, easy-to-use and cost-effective multi-parameter POCT instrument and its unique user friendly software provides an efficient data management system. Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.In stock
The technical innovation of the iSED® fully-automated ESR analyzer consists of directly measuring the intensity of the red cell aggregation which is responsible for Erythrocyte Sedimentation Rate (ESR). Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock
  • Made of high quality PP material with good transparency.
  • Applied for Gilson/Finland/Eppendorf Pipettors.
  • Carefully inspect of raw material and manufactured under strict process check, all tips are with excellent accuracy and precison.
  • Special siliconizing on the inner surface ensure no liquid adhesion and accurate sample transfer.
  • Standard tips and filter tips can be autoclaved, high temperature sterilization acceptable.
Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock Alcohol Pad (70% Isopropyl Alcohol Pre Pad, Alcohol Cleansing Swab). Clean the required area. Discard after single use. Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.In stock The coagulometer, LabPad® INR, measures blood coagulation time thanks to a patented optical technology. This portable In-Vitro Diagnostics (IVD) device works with the Tsmart® INR single-use microcuvettes. Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Content
  • INCLIX™ HbA1c quantitatively measures HemoglobinA1c(HbA1c) concentration in whole blood using the INCLIX™ analyzer. For in vitro diagnostic use only.
  • Hemoglobin A1c (glycated hemoglobin; HbA1c; A1c) test is the immunochromatography assay and intends for the quantitative determination of stable HbA1c in human blood. In this test system, HbA1c level is expressed in a percent as a good indicator to manage long-term glucose control in diabetes.
  • The HbA1c Test is the immunochromatography method to determine the percentage of glycated HbA1c in human blood. The detector antibody conjugated with colloidal gold can bind to HbA1c in human blood at conjugate pad where it dried. The detector antibody and HbA1c complex flows through membrane to where capture antibody for total hemoglobin immobilized at membrane of the strip. The signal intensity is measured with the INCLIX™ analyzer and the signal reflectance is calculated and shown as a percentage of concentration with established standard with known the percentage of HbA1c in blood samples.
INCLIX™ is an immunochromatographic analyzer providing immediate point-of-care testing (POCT) at patient care settings or clinical laboratories. It facilitates automatic detection of various biomarkers for cardiovascular disease, infectious disease, cancer, diabetes, allergy, and etc. with high accuracy and sensitivity. INCLIX™ analyzer is a compact, easy-to-use and cost-effective multi-parameter POCT instrument and its unique user friendly software provides an efficient data management system. Features: • Good accuracy owning to superior CMOS sensor & our own Algorism • 10,000 test results data storage • Instrument Check by Reference Kit • Remote Support available (when connected via Internet) • Built-in Thermal Printer and Barcode Scanner • Data export to USB(PDF, Excel), Email and LIS • Storage Temperature of Test Cassette & Buffer : Room temperature, 2 ~ 30 ℃ • Shelf Life of Test Cassette & Buffer : 24 months  
Click Here To Download Catalogue
 
The technical innovation of the iSED® fully-automated ESR analyzer consists of directly measuring the intensity of the red cell aggregation which is responsible for Erythrocyte Sedimentation Rate (ESR). Unlike traditional ESR methodologies that measure the aggregation of the red blood cells indirectly, the iSED measures it directly and expresses the values in mm/hr. Features:
  • Results in 20 Seconds

  • 100µL sample drawn directly from primary EDTA tube

  • Fully automated, walk-away operation

  • Random access

  • Positive patient identification via internal barcode reader

  • Compatible with pediatric tube

     
Technical Specifications: 
Principle of Measure: Photometrical
Results: “Printed mm/hr, Range from 1-130 mm/hr”
Sample Requirements: 500uL whole blood, collected in EDTA anti-coagulant tested 24 hours from venipuncture at room temperature or refrigerated.
Tube Requirements: 13 x 75 mm, pierceable capped tube
Quality Control: Barcoded Seditrol® QC
Barcode Reader: Internal
Printer: Internal
Interface Specifications: serial RS232 port for LIS connection
Weight: 14 kg
Dimensions (H x W x D): 36 x 27 x 34 (cm) /14.3 x 10.5 x13.4 (in)
Voltage: 100-240VAC
Frequency Range: 50-60 Hz
Power: 160W
Click Here To Download Catalogue
  • Made of high quality PP material with good transparency.
  • Applied for Gilson/Finland/Eppendorf Pipettors.
  • Carefully inspect of raw material and manufactured under strict process check, all tips are with excellent accuracy and precison.
  • Special siliconizing on the inner surface ensure no liquid adhesion and accurate sample transfer.
  • Standard tips and filter tips can be autoclaved, high temperature sterilization acceptable.
  Classification: PIPETTE Brand Name: Vchanslab,Yingmed,OEM Model Number: YM-K7028 Place of Origin: China Product name: Pipette Tips Material: Polypropylene Certificate: CE/ISO13485/FDA Color: Natural, Blue, Yellow Application: Laboratory, Teaching, Hospital
Alcohol Pad (70% Isopropyl Alcohol Pre Pad, Alcohol Cleansing Swab). Clean the required area. Discard after single use. Size and packing of Medical Alcohol pad:
  • Pad Size: Unfolded: 30 x 60 mm (other size can be request ).
  • Folded: 30x30 mm, 30 x 35mm,can be 2ply or 4ply ( other size, ply can be request ).
  • Aluminum Package: 60 x 50 mm , 50 x 50mm approximate ( other size can be request ).
  • Packing: 100/200 pcs per inner box, 50/ 100 boxes per carton(packing can be request).
Use of Medical Alcohol pad:
  • For cleaning prior to injection or to disinfect the hurted skin for family and medical treatment organization use.
  • For preparation and immediate disinfection of skin, wound area orr Instrument and utensil.
Notice of Medical Alcohol pad:
  • Not for eyes;
  • keep out of reach of children;
  • For external use only;
  • please stop using if you feel allergic or amyctic
Materials - Non-Woven Fabric
Trademark - OEM/ODM
Specification - CE&ISO13485
   
The coagulometer, LabPad® INR, measures blood coagulation time thanks to a patented optical technology. This portable In-Vitro Diagnostics (IVD) device works with the Tsmart® INR single-use microcuvettes.
  • User-friendly: the LabPad® INR is designed to be easy to use especially thanks to its 3D-shaped microcuvette that only requires a small drop of blood from a fingertip. Thanks to the color screen, both measurement steps and browsing the list of results are easy to visualize.
  • Quick and reliable: the reliability of INR results is obtained by quality controls that are performed automatically before each measurement. In less than one minute, you can see if you are in your therapeutic range.
  • Connected: the result obtained after performing the test can be transferred to healthcare professionals in charge of your treatment monitoring. This result is complementary to the pie charts and trend reports directly displayed on the LabPad® INR to help you monitoring your treatment
 
Click Here To Download Catalogue
   
WeightN/AN/AN/AN/AN/AN/A
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • Rating
  • Price
  • Description
Click outside to hide the comparison bar
Compare