Sugentech Inclix Troponin I Test Kit

$0.00

Shipped From Abroad

  • INCLIX™ Troponin I quantitatively measures troponin I concentration in whole blood, serum or plasma. using the INCLIX™ analyzer. For in vitro diagnostic use only.

Delivery & Availability:
Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.

SF1033560084-230
Brands:: Sugentech
Brands

Description

  • INCLIX™ Troponin I quantitatively measures troponin I concentration in whole blood, serum or plasma. using the INCLIX™ analyzer. For in vitro diagnostic use only.
  • Cardiac troponin I (Tn I) is a protein found in myocardial muscle and the most sensitive biomarker for detection of acute myocardial infarction (AMI).The concentration of Tn I in the healthy human is below about 0.5 ng/ml and the level of Tn I is increased within 4-6 hours after the onset of chest pain. After cardiac injury occurs, peak in approximately 8 to 28 hours, and remain elevated for 3 to 10 days following AMI. The Tn I test is well known to be an important prognostic indicator of heart disease.
  • The Tn I Test is based on immunochromatography technology. When the sample is loaded to the device, the detection antibody which is conjugated with the colloidal gold in the dried pad binds to Tn I and flows through the membrane. The detection antibody-gold conjugate and Tn I move to the test line area and are accumulated by the capture antibody immobilized on the membrane. This leads to the generation of a reddish colored band. The intensity of the band depends on quantity of Tn I molecules and is analyzed by INCLIX™ analyzer for quantitative readout

Reviews

There are no reviews yet.

Be the first to review “Sugentech Inclix Troponin I Test Kit”

Your email address will not be published. Required fields are marked *

Quick Comparison

Sugentech Inclix Troponin I Test Kit removeAvalun 48 INR Microcuvette removeZenithlab (IB-9025A) Laboratory Incubator removeAGD Erma EL-120 ELectrolyte Analyzer removeNikon SMZ745 Stereoscopic Microscope removeSkyla Hi POC Clinical Chemistry Analyzer remove
NameSugentech Inclix Troponin I Test Kit removeAvalun 48 INR Microcuvette removeZenithlab (IB-9025A) Laboratory Incubator removeAGD Erma EL-120 ELectrolyte Analyzer removeNikon SMZ745 Stereoscopic Microscope removeSkyla Hi POC Clinical Chemistry Analyzer remove
ImageSugentech Inclix Troponin I Test KitAvalun 48 INR MicrocuvetteNikon SMZ745 Stereoscopic Microscope
SKUSF1033560084-230SF1033560084-74SF1033560084-109SF1033560084-125SF1033560084-49SF1033560060-2
Rating
Price

$0.00

$0.00

$350.00

$1,320.00

$0.00

$0.00

Stock

Out of stock

AvailabilityOut of stock
Add to cart

DescriptionShipped From Abroad
  • INCLIX™ Troponin I quantitatively measures troponin I concentration in whole blood, serum or plasma. using the INCLIX™ analyzer. For in vitro diagnostic use only.
Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Out stock LabPad®’s versatility comes especially from its Tsmart® single-use microcuvette, which contains a lyophilized reagent specific to each test. The Tsmart® microcuvette is the fruit of numerous innovations that have led to many benefits for users. Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.In stock
  • Microprocessor control.
  • Digital display setting and actual temperature.
  • Over temperature alarm, PID self-tuning.
  • Digital display running timer.
  • Stainless steel interior.
  • Electricity leakage protection.
  • With glass inner door, With hidden door locks.
  • Mechanical overheat protection, cut off the heating sources.
  • Automatic alarm after operation.
  • Suitable for constant temperature tests.
  • Suitable for bacteria cultivation, breeding, ferment.
Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad
Electrolyte Analyzer ERMA EL-120 is ideal for medium to high volume Laboratories and Hospitals . It offers reliable, automated samples handling and work flow offences . It also allows measurement of specific ions, accurately and precisely . This supports fast diagnosis of critically ill patients and reduces the risks of patient discomfort associated with repeated sampling Precise & Accurate Results Economical to use Large Touchscreen Display with Graphical User Interface. Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock Nikon SMZ745 Stereoscopic Microscope: Featuring a zoom magnification of 7.5X and a long working distance of 115mm, Nikon SMZ745 microscopes are well suited for both industrial and biomedical applications. The adoption of a new total reflection prism produces brighter images with higher contrast, and the anti-mold design allows the microscope to be used in environments where the temperature and humidity are high. The SMZ-745T trinocular model comes equipped with a microscope camera port and a built-in 0.55x c-mount adapter, permitting direct mounting of Nikon DS Series Digital Cameras. Delivery & Availability: Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.Shipped from Abroad The skyla Hi POC Clinical Chemistry Analyzer provides clinical testing laboratories of medical facilities and clinics with an in-vitro clinical chemistry diagnostic tool that is compact, portable, and reports rapid results.The use of skyla Hi in the management of diabetes enables better access to testing and rapid clinical decision making, discussion,and implementation of optimized treatment. Delivery & Availability: Typically 14 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Content
  • INCLIX™ Troponin I quantitatively measures troponin I concentration in whole blood, serum or plasma. using the INCLIX™ analyzer. For in vitro diagnostic use only.
  • Cardiac troponin I (Tn I) is a protein found in myocardial muscle and the most sensitive biomarker for detection of acute myocardial infarction (AMI).The concentration of Tn I in the healthy human is below about 0.5 ng/ml and the level of Tn I is increased within 4-6 hours after the onset of chest pain. After cardiac injury occurs, peak in approximately 8 to 28 hours, and remain elevated for 3 to 10 days following AMI. The Tn I test is well known to be an important prognostic indicator of heart disease.
  • The Tn I Test is based on immunochromatography technology. When the sample is loaded to the device, the detection antibody which is conjugated with the colloidal gold in the dried pad binds to Tn I and flows through the membrane. The detection antibody-gold conjugate and Tn I move to the test line area and are accumulated by the capture antibody immobilized on the membrane. This leads to the generation of a reddish colored band. The intensity of the band depends on quantity of Tn I molecules and is analyzed by INCLIX™ analyzer for quantitative readout
LabPad®’s versatility comes especially from its Tsmart® single-use microcuvette, which contains a lyophilized reagent specific to each test. The Tsmart® microcuvette is the fruit of numerous innovations that have led to many benefits for users.
Features:
  • Fully automated "plug-and-play"   behavior
  • Reduced blood volume (only 3µL)
  • A large space for blood drop-off
  • Fills up quickly, using just capillarity
  • Easy handling, thanks to its 3D shape
  • Optimized preservation in individual pouches, in boxes of 12, 24, or 48 units
Features:
  • Microprocessor control.
  • Digital display setting and actual temperature.
  • Over temperature alarm, PID self-tuning.
  • Digital display running timer.
  • Stainless steel interior.
  • Electricity leakage protection.
  • With glass inner door, With hidden door locks.
  • Mechanical overheat protection, cut off the heating sources.
  • Automatic alarm after operation.
  • Suitable for constant temperature tests.
  • Suitable for bacteria cultivation, breeding, ferment.
  Technical Specification: Model: IB-9025A Working size: 250x250x250mm/9.84x9.84x9.84inch Power: 150W Temperature range: Room temperature+5~65℃ Temperature resolution: 0.1℃ Temperature fluctuation: ±0.5℃ Timer: 0-9999min Voltage: 110V 60Hz / 220V 50Hz Dimension: 380x370x580mm/14.96x14.57x22.83inch Size: 52cm*46cm*75cm / 20.5in*18.2in*29.6in Gross Weight:42kg / 93lb Net Weight: 23kg / 51lb Warranty: 1 year
Electrolyte Analyzer ERMA EL-120 is ideal for medium to high volume Laboratories and Hospitals . It offers reliable, automated samples handling and work flow offences . It also allows measurement of specific ions, accurately and precisely . This supports fast diagnosis of critically ill patients and reduces the risks of patient discomfort associated with repeated sampling Precise & Accurate Results Economical to use Large Touchscreen Display with Graphical User Interface. Features:
  • Parameters: Na+,K+,Cl-, iCa++ / Li
  • It works on ISE principle
  • Sample Type: Whole blood, Serum, Plasma, Urine
  • Low reagent consumption
  • Sample requirement is only 90ul
  • 60 samples per hour
  • Automatic two point calibration after 4hrs and one point calibration with each sample analysis
  • Air bubble detection
  • Track reagents consumption and provides alerts
  • For low reagent volume
  • Precision testing facility to get CV and SD
  • Trilevel Quality Control with LJ plots of last 30days
  • Low aspiration volume
  • Fast sample processing
  • Accurate and Precise results
Technical Specifications:
Parameters Na+, K+, Cl– /Ca++
Principle Ion Selective Electrode (ISE)
Sample Type Analyses whole blood, serum, plasma and urine
Sample Volume ≤100 µL
Analysis Time ≤60 seconds
Throughout ≤60 samples per hour
Data Link Serial (RS232)
External Interface USB (Keyboard, Mouse)
Operating Condition 10° C to 35° C, Relative Humidity up to 85%
Storage Condition Temp: 10° C to 40° C
Relative Humidity up to 85% non- condensing
Power Supply 100 to 240 VAC ±10%, 50Hz
Dimensions 395 x 260 x 375 mm
Weight 7.5 kg
 
Click Here To Download Catalogue
Nikon SMZ745 Stereoscopic Microscope: Featuring a zoom magnification of 7.5X and a long working distance of 115mm, Nikon SMZ745 microscopes are well suited for both industrial and biomedical applications. The adoption of a new total reflection prism produces brighter images with higher contrast, and the anti-mold design allows the microscope to be used in environments where the temperature and humidity are high. The SMZ-745 trinocular model comes equipped with a microscope camera port and a built-in 0.55x c-mount adapter, permitting direct mounting of Nikon DS Series Digital Cameras. Features:
  • Trinocular optical head for monitoring and digital imaging
  • Impressive 7.5x zoom magnification
  • 115 mm working distance
  • Maximum ergonomics
  • Rugged, durable design suits a variety of applications and environments
Technical Specifications:
Optical system Greenough optical system
Total magnification 3.35-300x, depending on eyepiece and auxiliary objective used
Vertical tube Built-in C-mount 0.55x magnification lens (F.N. 11), compatible with 2/3 in. or smaller CCD
Eyepiece tube Fixed type
Eyepiece inclination 45°
Interpupillary distance adjustment 52-75 mm
Eyepieces (with diopter adjustment) C-W 10xB (F.N. 22), C-W 15x (F.N. 16), C-W 20x (F.N. 12.5), C-W 30x (F.N. 7)
Zooming ratio 7.5:1 (approx.)
Zooming range 0.67-5x
Auxiliary objectives G-AL 0.5x (W.D. 211 mm), G-AL 0.7x (W.D. 150 mm), G-AL 1.5x (W.D. 61 mm), G-AL 2x (W.D. 43.5 mm)
Working distance 115 mm
     
 
 
skyla Hi Analyzer enables better access to testing and rapid clinical decision making, discussion, and implementation of optimized treatment. To get the result, only prepare <1 μl fingertips blood or venous blood (depends on test item) without pretreatment with easy steps and then read the result after 6 mins. The device allows two specimens be tested in one run and provides fully automatic procedures from checking the validity of cartridge to printing the results. Reagent Kit
  • HbA1C
  • CRP
  • Lipid Panel (TC,TG, HDL, LDL#)
  • Lipid Plus Panel (Glu,TC,TG, HDL, LDL#)
Main Specification
Principle
Turbidimetric Method / Biochemistry
Device
Testing Time
5~20 minutes (depends on test items)
Display and Interface
5″ TFT color touch screen LCD
Memory Capacity
50,000 test results
Dimension of Analyzer
270 x 188 x 148 mm
Weight of Analyzer
1.7 kg
Dimension of Printer Module
134 x 100 x 82.7 mm
Weight of Printer Module
0.37 kg
Power Supply
100~240 volts AC, 50-60Hz
Data Transmission
USB 2.0*4 / USB 3.0*1 / RS232*1 / RJ45*1 / Wi-Fi (optional)
Reagent and Samples
Samples
Fingertips blood or venous blood
Samples Volume
0.8 ~ 30 μL (depends on test item)
Storage Temperature (Reagent)
2 ~ 8˚C
Humidity
Relative humidity < 95% (Non-condensing)
Temperature
10 ~ 32 ˚C
Click Here To Download Catalogue
WeightN/AN/AN/AN/AN/AN/A
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • Rating
  • Price
  • Description
Click outside to hide the comparison bar
Compare