Super-Full Touch Screen Water Purification System

$0.00

Shipped From Abroad

The Super series uses city tap water as the water source, and can easily and quickly produce secondary RO (reverse osmosis) water, EDI deionized water and UP ultrapure water. It uses a standard two-stage reverse osmosis system and Ionpure EDI technology and modules to continuously produce Class II pure water with a TOC of more than 10MΩ.cm (25℃) and <30ppb, and ultrapure water of 18.2MΩ.cm (25℃). System water output: 10 liters/hour, and the daily output of pure water can reach 240 liters.

Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
SF1033560130126-3
Brands:: Hi-Tech

Description

Performance characteristics
  • New 7.0-inch color touch screen

The new 7-inch color 16:9 widescreen high-resolution full touch screen control system provides a new fingertip touch operation experience.

  • 4-channel water quality and 3-channel flow monitoring on the host

Source water, secondary RO water, EDI deionized water, UP ultrapure w

  • The lab optimized standard two-stage reverse osmosis system

The use of dual pumps, dual membranes and transition water tanks reduces system energy consumption and wastewater, ensuring stable water quality under different source water conditions.

ater, 4-way water quality online monitoring and water quality exceeding standard alarm function.

1-way source water flow statistics, EDI deionized water and UP ultrapure water 2-way high-precision quantitative water extraction function.

  • Standard-50L PE pure water tank

The polyethylene pure water tank with conical bottom design contains an air filter, which can effectively absorb CO2, organic matter and filter bacteria and particles, and can be equipped with UV ultraviolet irradiation sterilization components.

Features and Advantages
  • Built-in 3-pump system with primary and secondary RO booster pumps and circulation disinfection pumps to achieve complete two-stage reverse osmosis, system circulation and disinfection functions
  • Full-level filter element alarm prompt function based on time and flow, showing the used and remaining life of consumables
  • Automatic detection and alarm functions such as system water shortage alarm, water tank full alarm, water quality exceeding standard alarm, consumable life end alarm, water leakage protection alarm, etc. provide safety guarantee
  • Fully automatic RO membrane anti-scaling flushing program (flushing interval and duration can be set) to extend the service life of the RO membrane
  • Built-in SD card, can store and view operation data charts and curves, and can be inserted into a USB flash drive for complete data export, providing data traceability
  • With USB interface system program upgrade function, and optional WIFI module
  • Built-in perpetual calendar clock, convenient for consumables management and service settings
  • Ultrapure water full pipeline dosing disinfection function, just add disinfection tablets to start the one-key disinfection program to ensure high-quality pure water
  • Ultrapure water circulation function, which can be started and shut down freely to maintain low bacterial contamination level in the system
  • Factory and customer secondary passwords, system parameter settings are all password protected to prevent unauthorized changes
  • Compatible with 2 pure water storage methods of pressure water barrels to meet different application needs
  • High-strength all-engineering plastic chassis, ergonomic design, beautiful appearance, no corrosion and rust, ensure the cleanliness of the machine body, in line with GLP specifications
  • Unique 4-door design, pretreatment, RO and ultra-purification components, EDI and TOC modules, water tanks and control components adopt independent modular structures, making system maintenance more convenient
  • Pipes and joints are NSF certified to minimize TOC precipitation in the system and ensure the highest pure water quality
  • Powerful pre-treatment components, combined with 5μm PP transparent filter, KDF composite filter, coconut shell water-washing grade precision activated carbon filter, effectively protect the RO membrane
  • DOW RO reverse osmosis membrane, RO membrane components optimized by The lab, achieve the combination of long life, stability and high desalination rate of RO membrane
  • The new integrated ultra-purification component of DOW resin ensures that the water produced reaches 18.2MΩ.cm and reduces TOC precipitation
  • Ultra-long life 254&185nm dual wavelength UV lamp, combined with medical grade 316L flow hood, effectively sterilizes, reduces TOC, and enhances the system’s application range
  • UF ultrafiltration components, molecular weight cut-off: MWCO5000D, effectively remove pyrogens/endotoxins, can be used for precision cell culture and IVF
  • Double-layer terminal sterilizing filter, accuracy: (0.45+0.1)μm, using PES polyethersulfone composite filter membrane, double-layer filtration design to ensure the terminal effluent is sterile

 

Technical Parameters
name Basic Heat removal prototype Low organic matter type Comprehensive Built-in TOC monitor
model Super 10 Super 10F Super 10V Super 10FV Super-TOC10V Super-TOC 10FV
Pure water output 10 L/hour
Ultrapure water output Up to 2.0L/min (when there is water in the water tank)
Ultrapure water index
Resistivity (25℃) 18.2MΩ.cm
Total Organic Carbon TOC* <10ppb <10ppb <3ppb <3ppb <3ppb <3ppb
bacteria <0.01cfu/ml
Particles (>0.1μm) <1/ml
Pyrogens/endotoxins N/A <0.001Eu/ml N/A <0.001Eu/ml N/A <0.001Eu/ml
RNases N/A <1pg/ml N/A <1pg/ml N/A <1pg/ml
Deoxyribonucleases (DNases) N/A <5pg/ml N/A <5pg/ml N/A <5pg/ml
Pure water index
Resistivity* >5MΩ.cm
Total Organic Carbon (TOC)* <30ppb
Silicon Rejection Rate >99.9%
Source water requirements Urban drinking tap water, water temperature 5-45℃, water pressure 1.0-4.0Kgf/cm2
Size and weight Length × width × height: 545 × 470 × 649 mm, weight: about 35 kg
Electrical requirements 220-240V, 50/60Hz
power 240W
System Configuration Host (including 1 set of purification column) + TOC monitor (TOC type) + 50L PE ultrapure water storage tank

 

 

Reviews

There are no reviews yet.

Be the first to review “Super-Full Touch Screen Water Purification System”

Your email address will not be published. Required fields are marked *

Quick Comparison

SettingsSuper-Full Touch Screen Water Purification System removeVENUS SOLO OEM SENSOR removeLOW LEVEL CARBON MONOXIDE MONITOR removeMIR Spirolab Spirometer removePARTIAL PRESSURE O2 ANALYSER removeOXYGEN & CARBON DIOXIDE MONITOR remove
NameSuper-Full Touch Screen Water Purification System removeVENUS SOLO OEM SENSOR removeLOW LEVEL CARBON MONOXIDE MONITOR removeMIR Spirolab Spirometer removePARTIAL PRESSURE O2 ANALYSER removeOXYGEN & CARBON DIOXIDE MONITOR remove
ImageMIR Spirolab Spirometer
SKUSF1033560130126-3SF1033560130141-15SF1033560130141-4SF1033560084-13SF1033560130141-19SF1033560130141-12
Rating
Price

$0.00

$0.00

$0.00

$2,101.00

$0.00

$0.00

Stock
Availability
Add to cart

DescriptionShipped From Abroad The Super series uses city tap water as the water source, and can easily and quickly produce secondary RO (reverse osmosis) water, EDI deionized water and UP ultrapure water. It uses a standard two-stage reverse osmosis system and Ionpure EDI technology and modules to continuously produce Class II pure water with a TOC of more than 10MΩ.cm (25℃) and <30ppb, and ultrapure water of 18.2MΩ.cm (25℃). System water output: 10 liters/hour, and the daily output of pure water can reach 240 liters.
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad
Key Features
  • Single gas (user defined)
  • Backward compatible with ADC’s ‘Eclipse’
  • Linearised Output
  • Continuous status signal to check device health
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad
Key Features
  • Highly accurate 4-pin sensor
  • >3-year expected cell life
  • Temperature compensation Sub-ppm gas measurement
  • RS485 digital output
  • Optional pressure sensor
  • Easy cell replacement
  • High stability, low drift
  • Easy cell replacement
  • High stability, low drift
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In Stock
Spirometry test:
FVC, VC, MVV, PRE/POST Bronchodilator comparison with a wide range of selectable parameters. Pediatric Incentive for Spirometry. Each function can be easily activated by a simple touch on the bar menu Stand Alone Mode Delivery & Availability: Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad
Key Features
  • Compact in size making it ideal for confined space use
  • Fitted with a reliable PPO2 sensor, proven and tested within the hyperbaric environment
  • Large LCD display making readings easy to view
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad
Key Features
  • Operating temperature 0 °C to 40 °C (32 °F to 104 °F)
  • Dual state-of-the-art oxygen and carbon dioxide sensors
  • Two analogue outputs, one for each gas detected
  • Maximum power consumption less than 5 watts
  • Designed to operate safely in a vacuum for four hours
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Content
Performance characteristics
  • New 7.0-inch color touch screen

The new 7-inch color 16:9 widescreen high-resolution full touch screen control system provides a new fingertip touch operation experience.

  • 4-channel water quality and 3-channel flow monitoring on the host

Source water, secondary RO water, EDI deionized water, UP ultrapure w

  • The lab optimized standard two-stage reverse osmosis system

The use of dual pumps, dual membranes and transition water tanks reduces system energy consumption and wastewater, ensuring stable water quality under different source water conditions.

ater, 4-way water quality online monitoring and water quality exceeding standard alarm function.

1-way source water flow statistics, EDI deionized water and UP ultrapure water 2-way high-precision quantitative water extraction function.

  • Standard-50L PE pure water tank

The polyethylene pure water tank with conical bottom design contains an air filter, which can effectively absorb CO2, organic matter and filter bacteria and particles, and can be equipped with UV ultraviolet irradiation sterilization components.

Features and Advantages
  • Built-in 3-pump system with primary and secondary RO booster pumps and circulation disinfection pumps to achieve complete two-stage reverse osmosis, system circulation and disinfection functions
  • Full-level filter element alarm prompt function based on time and flow, showing the used and remaining life of consumables
  • Automatic detection and alarm functions such as system water shortage alarm, water tank full alarm, water quality exceeding standard alarm, consumable life end alarm, water leakage protection alarm, etc. provide safety guarantee
  • Fully automatic RO membrane anti-scaling flushing program (flushing interval and duration can be set) to extend the service life of the RO membrane
  • Built-in SD card, can store and view operation data charts and curves, and can be inserted into a USB flash drive for complete data export, providing data traceability
  • With USB interface system program upgrade function, and optional WIFI module
  • Built-in perpetual calendar clock, convenient for consumables management and service settings
  • Ultrapure water full pipeline dosing disinfection function, just add disinfection tablets to start the one-key disinfection program to ensure high-quality pure water
  • Ultrapure water circulation function, which can be started and shut down freely to maintain low bacterial contamination level in the system
  • Factory and customer secondary passwords, system parameter settings are all password protected to prevent unauthorized changes
  • Compatible with 2 pure water storage methods of pressure water barrels to meet different application needs
  • High-strength all-engineering plastic chassis, ergonomic design, beautiful appearance, no corrosion and rust, ensure the cleanliness of the machine body, in line with GLP specifications
  • Unique 4-door design, pretreatment, RO and ultra-purification components, EDI and TOC modules, water tanks and control components adopt independent modular structures, making system maintenance more convenient
  • Pipes and joints are NSF certified to minimize TOC precipitation in the system and ensure the highest pure water quality
  • Powerful pre-treatment components, combined with 5μm PP transparent filter, KDF composite filter, coconut shell water-washing grade precision activated carbon filter, effectively protect the RO membrane
  • DOW RO reverse osmosis membrane, RO membrane components optimized by The lab, achieve the combination of long life, stability and high desalination rate of RO membrane
  • The new integrated ultra-purification component of DOW resin ensures that the water produced reaches 18.2MΩ.cm and reduces TOC precipitation
  • Ultra-long life 254&185nm dual wavelength UV lamp, combined with medical grade 316L flow hood, effectively sterilizes, reduces TOC, and enhances the system's application range
  • UF ultrafiltration components, molecular weight cut-off: MWCO5000D, effectively remove pyrogens/endotoxins, can be used for precision cell culture and IVF
  • Double-layer terminal sterilizing filter, accuracy: (0.45+0.1)μm, using PES polyethersulfone composite filter membrane, double-layer filtration design to ensure the terminal effluent is sterile
 
Technical Parameters
name Basic Heat removal prototype Low organic matter type Comprehensive Built-in TOC monitor
model Super 10 Super 10F Super 10V Super 10FV Super-TOC10V Super-TOC 10FV
Pure water output 10 L/hour
Ultrapure water output Up to 2.0L/min (when there is water in the water tank)
Ultrapure water index
Resistivity (25℃) 18.2MΩ.cm
Total Organic Carbon TOC* <10ppb <10ppb <3ppb <3ppb <3ppb <3ppb
bacteria <0.01cfu/ml
Particles (>0.1μm) <1/ml
Pyrogens/endotoxins N/A <0.001Eu/ml N/A <0.001Eu/ml N/A <0.001Eu/ml
RNases N/A <1pg/ml N/A <1pg/ml N/A <1pg/ml
Deoxyribonucleases (DNases) N/A <5pg/ml N/A <5pg/ml N/A <5pg/ml
Pure water index
Resistivity* >5MΩ.cm
Total Organic Carbon (TOC)* <30ppb
Silicon Rejection Rate >99.9%
Source water requirements Urban drinking tap water, water temperature 5-45℃, water pressure 1.0-4.0Kgf/cm2
Size and weight Length × width × height: 545 × 470 × 649 mm, weight: about 35 kg
Electrical requirements 220-240V, 50/60Hz
power 240W
System Configuration Host (including 1 set of purification column) + TOC monitor (TOC type) + 50L PE ultrapure water storage tank
   
Description
The Venus Solo OEM sensor is a self-contained unit designed for integration into other manufacturers’ equipment and provides a measurement of gas concentration according to specific user requirements. These GFC (Gas Filter Correlation) sensors generate a signal proportional to the infrared absorption of the measured gas. Providing the gas concentration lies within the designed range of the sensor, the signal is periodically compared with a reference gas. Gas concentrations are indicated through the non-linearised analogue signal output. Gas connections to and from the sensor are via suitable fittings on the gas measuring cell. The Venus Solo OEM Series sensors electrical supply is designed to accept 24V DC (3amp max). Our Venus Solo OEM sensor uses GFC (Gas Filter Correlation) technology to give highly accurate gas measurements. The Venus Solo can be integrated into your own gas analyzer or management system and offers the user a 0-2.5v analogue output.

The sensor is currently available as either: Carbon dioxide (CO2), carbon monoxide (CO), nitrous oxide (N20), methane (CH4) or nitric oxide (NO). If your application requires a different gas, just let us know and we can customise it to your needs. The Venus Solo is used in Military applications to protect submariners from carbon monoxide (CO) exposure.  

Technical Specification
Venus Solo
Description
The TEC CO is a device for monitoring very low levels of carbon monoxide (CO). This is housed in a robust miniature enclosure rated for IP55 ingress protection, with built-in temperature compensation and an RS485 digital output via Analox communications protocol. The sensors are backwards-compatible with the existing MEC (mini electrochemical) range and offer the same modular approach to gas monitoring.  
Technical Specifications
TEC CO
Spirometry test:
FVC, VC, MVV, PRE/POST Bronchodilator comparison with a wide range of selectable parameters. Paediatric Incentive for Spirometry. Each function can be easily activated by a simple touch on the bar menu Stand Alone Mode. Colour screen Touchscreen 7 inches TFT display Database up to 10,000 Spirometry tests or 900 hours of Oximetry recording coupled with powerful and flexible search services. Optional function available: Oximeter with adult or paediatric finger probe. Long life Rechargeable Battery. Available with both DISPOSABLE or REUSABLE turbine flowmeter. PC based mode, using WinspiroPRO® Bluetooth® 2.1 and USB Connectivity Wireless or via cable Real Time test directly on your PC. Winspiro PRO® PC software provides Real Time Flow/Volume and Volume/Time curves with PRE/POST Bronchodilator comparison on your PC. Includes free online updates. Paediatric Incentive for Spirometry with wide choice of pictures and animations. Spirometry test after drug adminitration Bronchodilator Reversibility, Bronchial Challenge with FEV1-response curve with protocols for both Methacholine and Mannitol. Quanjer 2012-GLI Predicted values with LLN and Z-score Patient Trend Charts for easy follow-up Search engine for instant access to database. Wide choice of communication protocols for integration with EMR.
Spirometry parameters: FVC, FEV1, FEV1/FVC, FEV1/VC, PEF, FEF25, FEF50, FEF75, FEF25–75, FEF75–85, Lung Age, Extrapolated Volume, FET, Time to PEF, FEV0.5, FEV0.5/FVC, FEV0.75, FEV0.75/FVC, FEV2, FEV2/FVC, FEV3, FEV3/FVC, FEV6, FEV1/ FEV6, FEV1/PEF, FEV1/ FEV0.5, FIVC, FIV1, FIV1/FIVC, PIF, FIF25, FIF50, FIF75, FEF50/FIF50, VC, IVC, IC, ERV, IRV, Rf, VE, VT, tI, tE, VT/tI, tE/tTOT, MVV (measured), MVV (calculated).  
Click Here To Download Catalogue
 
Description
The HYP is a rugged and compact portable partial pressure monitor. Simple to operate, the HYP accurately reads oxygen (O2) levels within the hyperbaric environment.
O2 monitoring with the HYP
Classification bodies and industry guidelines within the diving market require each hyperbaric chamber to have a means of providing independent oxygen (O2) monitoring in the event of the primary monitor failing. The HYP is a portable PPO2 monitor capable of helping you to achieve such guidelines.  
Oxygen Sensor
The compact size allows for convenient fitting within confined spaces such as diving bells and hyperbaric lifeboats, or alternatively the unit can easily be hand carried. It is very simple to use, with just a single push-button to switch power on and off, and an LCD display. It may be used at depths of up to 600MSW / 2000FSW, and can also be used at surface pressures.
Technical Specification
HYP
Click here to download Data Sheet
Click here to download Quick Start Guide
Click here to download User Manual
Description
The SV-Multigas-2 is a dual oxygen (O2) and carbon dioxide (CO2) monitor designed for vehicles operating in the upper atmosphere. Housed in a robust, compact enclosure, the unit is ideal for use in airborne delivery systems, satellites and aircraft cabins. Since 2014 the SV-Multigas-2 has been successfully used in rockets travelling to outer space. Flexibility The SV-Multigas-2 incorporates user maintainable analogue sensors that provide a 1 to 5 V output. This modular approach to gas monitoring ensures that our customers have the flexibility to integrate the unit into their own system. It can be either installed directly in the gas path or used for general air monitoring.  
Technical Specification
SV-Multigas-2
WeightN/AN/AN/AN/AN/AN/A
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • Rating
  • Price
  • Description
Click outside to hide the comparison bar
Compare