Description

SURTRON 160 is a high-frequency electrosurgical equipment that is suitable to light and medium surgery. SURTRON 160, through its performance, allows pure CUT, cut-coagulation BLEND, superficial coagulation FORCED COAG, deep coagulation in the absence of necrosis SOFT COAG, and, with a special adapter, BIPOLAR coagulation. The digital reading of delivered power and the monitoring of operative function by a microcontroller guarantee the absolute reliability of working conditions. SURTRON 160 allows a highly professional surgery thanks to the user-friendly and safety solutions normally used. The connection of the neutral electrode is constantly monitored. Safety control of patient/plate contact using split neutral electrode. The possibility to control by the handle the monopolar output functions as well as the delivery of output power, allows for the implementation of the surgical operation without diverting the surgeon’s attention from the surgical field.

Key Features
  • Operating Modes: Supports multiple modes including pure CUT, cut-coagulation BLEND, superficial coagulation (FORCED COAG), deep coagulation without necrosis (SOFT COAG), and, with a special adapter, BIPOLAR coagulation.

  • Digital Interface: Equipped with a microcontroller for digital reading of delivered power and monitoring of operative functions, ensuring reliable performance.

  • Safety Measures: Features patient/plate circuit monitoring, output power monitoring, and self-check control. The connection of the neutral electrode is constantly monitored, with safety control of patient/plate contact using a split neutral electrode.

  • Underwater Cutting and Coagulation: Capable of performing procedures in wet environments, expanding its range of applications.

 

Technical Data
  • Max output power CUT 160 W-250 Ω
  • Max output power BLEND 120 W-200 Ω
  • Max output power FORCED COAG 100W-150Ω
  • Max output power SOFT COAG 80 W-100 Ω
  • Max output power BIPOLAR 60 W-100 Ω
  • Working frequency 600 KHz
  • Patient circuit F
  • Selectable input voltage 115-230 VAC
  • Main frequency 50-60 Hz
  • Electrical input power: 350 VA
  • Size WxHxD  254x104x288 mm
  • Weight 5 Kgs

 

CONTROLS

  • Patient/Plate circuit monitoring
  • Output power monitoring
  • Self-check control

 

SAFETY

  • EN60601-1
  • EN60601-1-2
  • EN60601-2-2
  • Electrical Class: I CF
  • MDR 2017/745/UE Class: II b

Reviews

There are no reviews yet.

Be the first to review “SURTRON 160”

Your email address will not be published. Required fields are marked *

Quick Comparison

SURTRON 160 removeDisposable ECG Monitoring Electrode removeDisposable Subdermal Needle Electrodes removeElectrotherapy Electrode with Cables removeOBS-100C(II) Cold RF Unit removeBipolar Artery Forceps remove
NameSURTRON 160 removeDisposable ECG Monitoring Electrode removeDisposable Subdermal Needle Electrodes removeElectrotherapy Electrode with Cables removeOBS-100C(II) Cold RF Unit removeBipolar Artery Forceps remove
Image
SKUSF1033560130165-24SF1033560130165-25SF1033560130165-23SF1033560130165-6SF1033560130165-20
Rating
Price

$0.00

$0.00

$0.00

$0.00

$0.00

$0.00

Stock
Availability
Add to cart

DescriptionShipped From Abroad
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad Disposable ECG Electrodes consist of snap set, conductive gel, backing material with medical adhesive, and release film. OBS Disposable ECG Electrodes model 301 are Non-woven, Micropore fabric backing Electrodes . These electrodes are applied by or on the order of a physician on a patient’s skin, the model 301 is fit for the general electrocardiographic application of both adults and children.
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad OBS-100C(II) uses high-frequency radio wave technology as an energy source to cut and coagulate soft tissue. it operates at 3.8MHz, enabling a precise incision with significantly less heat and resultant heat damage than typically found with conventional electrosurgery. Since tissue stays cooler with high-frequency radio wave technology, you can feel confident that you are minimizing cellular destruction along the incision path.
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
ContentSURTRON 160 is a high-frequency electrosurgical equipment that is suitable to light and medium surgery. SURTRON 160, through its performance, allows pure CUT, cut-coagulation BLEND, superficial coagulation FORCED COAG, deep coagulation in the absence of necrosis SOFT COAG, and, with a special adapter, BIPOLAR coagulation. The digital reading of delivered power and the monitoring of operative function by a microcontroller guarantee the absolute reliability of working conditions. SURTRON 160 allows a highly professional surgery thanks to the user-friendly and safety solutions normally used. The connection of the neutral electrode is constantly monitored. Safety control of patient/plate contact using split neutral electrode. The possibility to control by the handle the monopolar output functions as well as the delivery of output power, allows for the implementation of the surgical operation without diverting the surgeon's attention from the surgical field.
Key Features
  • Operating Modes: Supports multiple modes including pure CUT, cut-coagulation BLEND, superficial coagulation (FORCED COAG), deep coagulation without necrosis (SOFT COAG), and, with a special adapter, BIPOLAR coagulation.

  • Digital Interface: Equipped with a microcontroller for digital reading of delivered power and monitoring of operative functions, ensuring reliable performance.

  • Safety Measures: Features patient/plate circuit monitoring, output power monitoring, and self-check control. The connection of the neutral electrode is constantly monitored, with safety control of patient/plate contact using a split neutral electrode.

  • Underwater Cutting and Coagulation: Capable of performing procedures in wet environments, expanding its range of applications.

 
Technical Data
  • Max output power CUT 160 W-250 Ω
  • Max output power BLEND 120 W-200 Ω
  • Max output power FORCED COAG 100W-150Ω
  • Max output power SOFT COAG 80 W-100 Ω
  • Max output power BIPOLAR 60 W-100 Ω
  • Working frequency 600 KHz
  • Patient circuit F
  • Selectable input voltage 115-230 VAC
  • Main frequency 50-60 Hz
  • Electrical input power: 350 VA
  • Size WxHxD  254x104x288 mm
  • Weight 5 Kgs
  CONTROLS
  • Patient/Plate circuit monitoring
  • Output power monitoring
  • Self-check control
  SAFETY
  • EN60601-1
  • EN60601-1-2
  • EN60601-2-2
  • Electrical Class: I CF
  • MDR 2017/745/UE Class: II b
Indications for Use:

Disposable ECG Electrodes are pre-gelled, non-sterile, single use disposable electrocardiographic electrodes which are intended for use as an accessory to ECG equipment for ECG monitoring , diagnostic procedures and can used for stress test & holter.

Instruction for Use:

1. Clean the skin area where the electrode will stick on. Make sure the skin area for sticking is intact (uninjured). 2. Connect the leadwire with the electrode. Make sure it is fastened and in good contact. 3. Tear off the release film from the bottom (the part away from metal stud) of electrode. 4. Press lightly when stick the electrodes to the skin and make sure the conductive gel and adhesive backing stick on the skin tightly. Caution

  • Don’t peel the release film from the metal stud of the electrode. It may break the structure and affect the function of electrodes.
  • ECG electrodes should only be used by or in consultation with a healthcare provider familiar with their proper placement and use.
  • ECG electrodes may damage the skin if removed carelessly.
  • ECG electrodes should be applied only to intact, clean skin (e.g., not over open wounds, lesions, or infected, or inflamed areas).
  • Do not reuse this device. It may cause infection and affect the performance of the reuse of this device.
Electrotherapy electrodes with cables are used to connect the electrodes to the electrotherapy device, allowing electrical currents to be delivered to the targeted area. These cables typically have a standard 2mm pin connector that plugs into the device and the electrodes. There are different types of cables available, such as:
  • Standard Lead Wires: These are the basic cables that come with most electrotherapy units.
  • Bifurcation Cables: These cables allow you to connect multiple electrodes to a single channel, effectively doubling the number of electrodes you can use.
  • Extended Length Cables: These are longer cables that provide more flexibility in positioning the electrodes.
WeightN/AN/AN/AN/AN/AN/A
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • Rating
  • Price
  • Description
Click outside to hide the comparison bar
Compare