New

SURTRON EVAC-Vacuum and Filtering Smoke System

$0.00

Shipped From Abroad

The SURTRON EVAC is a surgical smoke evacuation and filtration system developed by LED SpA. It is designed to efficiently remove and filter the smoke generated during electrosurgical procedures, enhancing both safety and visibility in the operating room.

 

Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Brands:: LED Surtron

Description

SURTRON EVAC is an aspiration and filtering system for the smoke produced during the surgical procedures. The smokes, generated during the surgical procedures, have a bad, strong, and long smell. These smokes consist of water vapour, organic gas, visible or invisible solid particles, and viral particles. So a good aspiration and filtration eliminates bad smells, reduces the bacteriologist and/or viral risks, and solves the particularly annoying problem of the optimal vision of the zone of the intervention, during the laparoscopic procedures. In SURTRON EVAC, the activation of the aspiration can be: AUTOMATIC, through an electronic system of survey of the activation of the high-frequency electrosurgical unit; or MANUAL, acting directly on the unit through a foot switch (optional). The flux of the aspiration can be regulated to be suitable for the singular necessities. For laparoscopic procedures, there is a specific function, quickly selectable. SURTRON EVAC has an electronic control of the aspiration with the indication of the status of the filters.

There are two different kinds of filters, quickly substitutable and constituted by a filtering ULPA type with an active carbon part dedicated to the elimination of the bad smells of the electrosurgical smokes and a connector of 7/8” (22mm). The filters have an electronic system for the control of the status of use.

The BLUE filter is the standard filter and it is included with the unit for the first time of use.

The RED filter is an optional spare part, created for a long time of use.

 

Technical Data
  • Input voltage 230 VAC or 115 VAC
  • Main frequency 50 Hz
  • Electrical input power 800 VA
  • Max vacuum flow rate 1000 LPM (35 CFM)
  • Max static suction 250 mbar (83 in H2O)
  • Filter type ULPA with active carbon
  • Filter efficiency 99,999X%
  • Particle diameter 0,12 micron
  • Max vacuum flow rate with filter 300 LPM (11 CFM)
  • Size WxHxD 370x144x319 mm
  • Weight 4 Kg

Reviews

There are no reviews yet.

Be the first to review “SURTRON EVAC-Vacuum and Filtering Smoke System”

Your email address will not be published. Required fields are marked *

Quick Comparison

SettingsSURTRON EVAC-Vacuum and Filtering Smoke System removeDisposable LOOP Tungsten Electrode removeSS-100 Smoke Evacuation System removeElectrotherapy Electrode with Cables removeDisposable ECG Monitoring Electrode removeOBS-100C(II) Cold RF Unit remove
NameSURTRON EVAC-Vacuum and Filtering Smoke System removeDisposable LOOP Tungsten Electrode removeSS-100 Smoke Evacuation System removeElectrotherapy Electrode with Cables removeDisposable ECG Monitoring Electrode removeOBS-100C(II) Cold RF Unit remove
Image
SKUSF1033560130165-14SF1033560130165-9SF1033560130165-23SF1033560130165-24SF1033560130165-6
Rating
Price

$0.00

$0.00

$0.00

$0.00

$0.00

$0.00

Stock
Availability
Add to cart

DescriptionShipped From Abroad The SURTRON EVAC is a surgical smoke evacuation and filtration system developed by LED SpA. It is designed to efficiently remove and filter the smoke generated during electrosurgical procedures, enhancing both safety and visibility in the operating room.  
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad

The SS-100 Smoke Evacuation System is designed to protect medical staff and patients from harmful surgical smoke generated during electrosurgical procedures

Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad Disposable ECG Electrodes consist of snap set, conductive gel, backing material with medical adhesive, and release film. OBS Disposable ECG Electrodes model 301 are Non-woven, Micropore fabric backing Electrodes . These electrodes are applied by or on the order of a physician on a patient’s skin, the model 301 is fit for the general electrocardiographic application of both adults and children.
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad OBS-100C(II) uses high-frequency radio wave technology as an energy source to cut and coagulate soft tissue. it operates at 3.8MHz, enabling a precise incision with significantly less heat and resultant heat damage than typically found with conventional electrosurgery. Since tissue stays cooler with high-frequency radio wave technology, you can feel confident that you are minimizing cellular destruction along the incision path.
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
ContentSURTRON EVAC is an aspiration and filtering system for the smoke produced during the surgical procedures. The smokes, generated during the surgical procedures, have a bad, strong, and long smell. These smokes consist of water vapour, organic gas, visible or invisible solid particles, and viral particles. So a good aspiration and filtration eliminates bad smells, reduces the bacteriologist and/or viral risks, and solves the particularly annoying problem of the optimal vision of the zone of the intervention, during the laparoscopic procedures. In SURTRON EVAC, the activation of the aspiration can be: AUTOMATIC, through an electronic system of survey of the activation of the high-frequency electrosurgical unit; or MANUAL, acting directly on the unit through a foot switch (optional). The flux of the aspiration can be regulated to be suitable for the singular necessities. For laparoscopic procedures, there is a specific function, quickly selectable. SURTRON EVAC has an electronic control of the aspiration with the indication of the status of the filters. There are two different kinds of filters, quickly substitutable and constituted by a filtering ULPA type with an active carbon part dedicated to the elimination of the bad smells of the electrosurgical smokes and a connector of 7/8” (22mm). The filters have an electronic system for the control of the status of use. The BLUE filter is the standard filter and it is included with the unit for the first time of use. The RED filter is an optional spare part, created for a long time of use.  
Technical Data
  • Input voltage 230 VAC or 115 VAC
  • Main frequency 50 Hz
  • Electrical input power 800 VA
  • Max vacuum flow rate 1000 LPM (35 CFM)
  • Max static suction 250 mbar (83 in H2O)
  • Filter type ULPA with active carbon
  • Filter efficiency 99,999X%
  • Particle diameter 0,12 micron
  • Max vacuum flow rate with filter 300 LPM (11 CFM)
  • Size WxHxD 370x144x319 mm
  • Weight 4 Kg
 
Features
1. Stainless steel & non-stick finish 2. The hexagonal connection ring fits the pencil locking design. 3. Different shapes fitting for different surgeries
Experts have identified harmful smoke which contains a variety of toxic gases and vapors will occur during electrosurgical operation. Medical staff and patients exposure to the smoke in large may cause viral contamination,respiratory problems,nausea and burning eyes.To use a smoke evacuation system is the most effective way of protecting operating room staff and patients from hazards.
 
Features
  • Effective smoke removal: Captures toxic gases and vapors.
  • Compact and portable: Weighs 3.5 kg with a trolley cart for easy mobility.
  • Quiet operation: Works at 55 dB.
  • High efficiency: Processes 3.5-4.2 cubic meters of smoke per hour.
  • Automatic startup: Can be activated by an internal sensor or foot switch
Electrotherapy electrodes with cables are used to connect the electrodes to the electrotherapy device, allowing electrical currents to be delivered to the targeted area. These cables typically have a standard 2mm pin connector that plugs into the device and the electrodes. There are different types of cables available, such as:
  • Standard Lead Wires: These are the basic cables that come with most electrotherapy units.
  • Bifurcation Cables: These cables allow you to connect multiple electrodes to a single channel, effectively doubling the number of electrodes you can use.
  • Extended Length Cables: These are longer cables that provide more flexibility in positioning the electrodes.
Indications for Use:

Disposable ECG Electrodes are pre-gelled, non-sterile, single use disposable electrocardiographic electrodes which are intended for use as an accessory to ECG equipment for ECG monitoring , diagnostic procedures and can used for stress test & holter.

Instruction for Use:

1. Clean the skin area where the electrode will stick on. Make sure the skin area for sticking is intact (uninjured). 2. Connect the leadwire with the electrode. Make sure it is fastened and in good contact. 3. Tear off the release film from the bottom (the part away from metal stud) of electrode. 4. Press lightly when stick the electrodes to the skin and make sure the conductive gel and adhesive backing stick on the skin tightly. Caution

  • Don’t peel the release film from the metal stud of the electrode. It may break the structure and affect the function of electrodes.
  • ECG electrodes should only be used by or in consultation with a healthcare provider familiar with their proper placement and use.
  • ECG electrodes may damage the skin if removed carelessly.
  • ECG electrodes should be applied only to intact, clean skin (e.g., not over open wounds, lesions, or infected, or inflamed areas).
  • Do not reuse this device. It may cause infection and affect the performance of the reuse of this device.
WeightN/AN/AN/AN/AN/AN/A
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • Rating
  • Price
  • Description
Click outside to hide the comparison bar
Compare