SURTRON EVAC-Vacuum and Filtering Smoke System

$0.00

Shipped From Abroad

The SURTRON EVAC is a surgical smoke evacuation and filtration system developed by LED SpA. It is designed to efficiently remove and filter the smoke generated during electrosurgical procedures, enhancing both safety and visibility in the operating room.

 

Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Brands:: LED Surtron

Description

SURTRON EVAC is an aspiration and filtering system for the smoke produced during the surgical procedures. The smokes, generated during the surgical procedures, have a bad, strong, and long smell. These smokes consist of water vapour, organic gas, visible or invisible solid particles, and viral particles. So a good aspiration and filtration eliminates bad smells, reduces the bacteriologist and/or viral risks, and solves the particularly annoying problem of the optimal vision of the zone of the intervention, during the laparoscopic procedures. In SURTRON EVAC, the activation of the aspiration can be: AUTOMATIC, through an electronic system of survey of the activation of the high-frequency electrosurgical unit; or MANUAL, acting directly on the unit through a foot switch (optional). The flux of the aspiration can be regulated to be suitable for the singular necessities. For laparoscopic procedures, there is a specific function, quickly selectable. SURTRON EVAC has an electronic control of the aspiration with the indication of the status of the filters.

There are two different kinds of filters, quickly substitutable and constituted by a filtering ULPA type with an active carbon part dedicated to the elimination of the bad smells of the electrosurgical smokes and a connector of 7/8” (22mm). The filters have an electronic system for the control of the status of use.

The BLUE filter is the standard filter and it is included with the unit for the first time of use.

The RED filter is an optional spare part, created for a long time of use.

 

Technical Data
  • Input voltage 230 VAC or 115 VAC
  • Main frequency 50 Hz
  • Electrical input power 800 VA
  • Max vacuum flow rate 1000 LPM (35 CFM)
  • Max static suction 250 mbar (83 in H2O)
  • Filter type ULPA with active carbon
  • Filter efficiency 99,999X%
  • Particle diameter 0,12 micron
  • Max vacuum flow rate with filter 300 LPM (11 CFM)
  • Size WxHxD 370x144x319 mm
  • Weight 4 Kg

Reviews

There are no reviews yet.

Be the first to review “SURTRON EVAC-Vacuum and Filtering Smoke System”

Your email address will not be published. Required fields are marked *

Quick Comparison

SURTRON EVAC-Vacuum and Filtering Smoke System removeArthroscopic Ablator removeOBS-100C(I) Intelligent Electrosurgical Unit removeOBS-350A LCD Version Electrosurgical Generator removeOBS-100A Monopolar Electrosurgical Unit removeSS-100 Smoke Evacuation System remove
NameSURTRON EVAC-Vacuum and Filtering Smoke System removeArthroscopic Ablator removeOBS-100C(I) Intelligent Electrosurgical Unit removeOBS-350A LCD Version Electrosurgical Generator removeOBS-100A Monopolar Electrosurgical Unit removeSS-100 Smoke Evacuation System remove
Image
SKUSF1033560130165-13SF1033560130165-2SF1033560130165-4SF1033560130165-7SF1033560130165-9
Rating
Price

$0.00

$0.00

$0.00

$0.00

$0.00

$0.00

Stock
Availability
Add to cart

DescriptionShipped From Abroad The SURTRON EVAC is a surgical smoke evacuation and filtration system developed by LED SpA. It is designed to efficiently remove and filter the smoke generated during electrosurgical procedures, enhancing both safety and visibility in the operating room.  
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad Portable in size, available in both monopolar and bipolar modes, convenient handle power control and memory function, suitable for microsurgery, gynecology, and arthroscopy.
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad The OBS-350A LCD Version Electrosurgical Generator is a versatile medical device used in various surgical procedures. It provides up to 350W of cutting power and 150W of coagulating power, operating at a frequency of 417 kHz. Featuring both monopolar and bipolar modes, it offers 8 working modes, including pure cut and bipolar vessel sealing. The device has a user-friendly LCD display and can store up to 10 presets for quick access. It's suitable for surgeries such as general, vascular, laparoscopic, and gynecological procedures.
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad

The SS-100 Smoke Evacuation System is designed to protect medical staff and patients from harmful surgical smoke generated during electrosurgical procedures

Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
ContentSURTRON EVAC is an aspiration and filtering system for the smoke produced during the surgical procedures. The smokes, generated during the surgical procedures, have a bad, strong, and long smell. These smokes consist of water vapour, organic gas, visible or invisible solid particles, and viral particles. So a good aspiration and filtration eliminates bad smells, reduces the bacteriologist and/or viral risks, and solves the particularly annoying problem of the optimal vision of the zone of the intervention, during the laparoscopic procedures. In SURTRON EVAC, the activation of the aspiration can be: AUTOMATIC, through an electronic system of survey of the activation of the high-frequency electrosurgical unit; or MANUAL, acting directly on the unit through a foot switch (optional). The flux of the aspiration can be regulated to be suitable for the singular necessities. For laparoscopic procedures, there is a specific function, quickly selectable. SURTRON EVAC has an electronic control of the aspiration with the indication of the status of the filters. There are two different kinds of filters, quickly substitutable and constituted by a filtering ULPA type with an active carbon part dedicated to the elimination of the bad smells of the electrosurgical smokes and a connector of 7/8” (22mm). The filters have an electronic system for the control of the status of use. The BLUE filter is the standard filter and it is included with the unit for the first time of use. The RED filter is an optional spare part, created for a long time of use.  
Technical Data
  • Input voltage 230 VAC or 115 VAC
  • Main frequency 50 Hz
  • Electrical input power 800 VA
  • Max vacuum flow rate 1000 LPM (35 CFM)
  • Max static suction 250 mbar (83 in H2O)
  • Filter type ULPA with active carbon
  • Filter efficiency 99,999X%
  • Particle diameter 0,12 micron
  • Max vacuum flow rate with filter 300 LPM (11 CFM)
  • Size WxHxD 370x144x319 mm
  • Weight 4 Kg
Features

1. Intended for ablation,tissue modification, and coagulation of soft tissue in arthroscopic procedures such as hip,  shoulder, ankle, wrist, elbow, and knee. 2. The Extending shaft enables good visualization and easy insertion through subcutaneous tissue,and  well insulated coating guarantee its safety and reliability. 3.Irrigation/suction solution is available with a cannula and an adjustable flow control valve. 4. Tips in different shapes and angles fit in particular arthroscopic procedures. 5. Compatible with most electrosurgical generators.

Use Indication

This device should never be used when:

  • There is visible evidence of damage to the exterior of the device such as cracked or damaged plastic or connector damage.
  • These devices fail the inspection described herein.
  • In the presence of flammable gases, flammable prep solutions or drapes. Oxidizing. Gases such as Nitrous Oxide (N2O), or in oxygen-riched environments.
  • Do not use monopolar electrosurgery on small appendages, as in circumcision or finger surgery.
 
Key Features
OBS-100 Electrosurgical Generator with state-of-art technology offers superb performance on the electro-surgery, and shows remarkable safety, reliability and convenience. 1. Two levels of coagulation: pinpoint coagulation and fulguration Pinpoint coagulation provides precise control of bleeding in localized areas. Fulguration provides greater control of bleeding in highly vascular over-surface areas. 2. Presets The unit incorporates as many as ten user-defined presets for easy recall of frequency and settings. 3. Isolated RF output for Cut, Blend, and Coag modes This minimizes the potential of alternate site burns. 4. Ground Referenced RF output for Fulguration modes 5. Self-diagnostics These diagnostics continually monitor the unit to ensure proper performance. If the diagnostics is unsuccessful, the warning tones can be heard.
Technical parameters:
Environmental temperature range: 5°C~ 40°C
Relative moisture range: ≤80%
Atmosphere pressure range: 86.0 ~ 106.0 Kpa
 Working modes:
Pure cut: 1w ~ 60w (Load 500Ω)
Blend: 1w ~ 60w (Load 800Ω)
Coagulation: 1w ~ 60w (Load 1000Ω)
Fulguration: 0.1w ~ 35w (Load 1000Ω)
Bipolar: 1w ~ 30w (Load 200Ω)
Technology data:
Voltage: 220V±10V, 50Hz ±1Hz
Working frequency: 357 KHz ~ 575 KHz
Leakage currents to ground: Less than 0.5mA
Leakage currents to patient: Less than 0.01mA
Display Setting: Fulguration a.      0-10 range: 0.1watt increments b.      10-35range: 1.0 watt increments Cut, Blend, Coagulation, and Bipolar 1.0-watt increments Power supply:220V±10%,50±1%Hz. Transportation and storage a)        Ambient temperature range: -40°C~55°C; b)        Relative moisture range: ≤95%; c)        Atmosphere pressure range: 500hPa~1060hPa. Accessories Included: Electrosurgical Pencil, disposable                           2pcs Bipolar Forceps with cable, reusable                      1pc Disposable Electrosurgical Pad                               2pcs Cable for Electrosurgical Pad, reusable                  1pc Footswitch                                                              1pc Power cord                                                             1pc Manual                                                                    1pc
Features
  • Power: It offers cutting power up to 350W and coagulating power up to 150W.
  • Frequency: Operates at 417 kHz.
  • Applications: Suitable for general surgery, vascular surgery, hepatobiliary and pancreatic surgery, cardiothoracic surgery, gastroenterology, TURP (Transurethral Resection of the Prostate), TUVP (Transurethral Vaporization of the Prostate), and compatible with cystoscopy, arthroscopy, laparoscopy, and hysteroscopy.
  • Modes: It has 8 different working modes including pure cut, blend, coagulation, and bipolar vessel sealing.
  • Display: Features a 7-segment LED display for easy monitoring.
  • Presets: Comes with 10 saved presets for quick access
  • Monopolar and Bipolar Modes: This device supports both monopolar and bipolar modes, offering flexibility for various surgical needs.
  • User-friendly Interface: The intuitive LCD display provides real-time feedback and easy control settings, enhancing the precision and efficiency of surgical procedures.
  • Safety Features: It includes automatic self-checking systems and alarms for safety, ensuring reliable performance during operations.
  • Memory Function: You can save and recall up to 10 presets, allowing for quick setup and operation tailored to specific surgical requirements.
  • Efficient Smoke Evacuation: Integrated smoke evacuation system helps maintain a clear surgical field and improves visibility.
Technical Specifications
  • Cutting Power: Up to 350W
  • Coagulating Power: Up to 150W
  • Frequency: 417 kHz
  • Power Supply: AC 100-240V, 50/60Hz
  • Dimensions: 380mm x 280mm x 120mm
  • Weight: Approximately 6kg
Applications
  • General Surgery: Versatile for cutting and coagulating tissue.
  • Vascular Surgery: Precise control for delicate procedures.
  • Laparoscopy: Compatible with minimally invasive surgical techniques.
  • Hysteroscopy: Suitable for gynecological procedures.
 
Features

1. Portable and  affordable

2. Suitable for general surgery and veterinary
Technical Details
Environmental temperature range: 5°C~ 40°C
Relative moisture range: ≤80%
Atmosphere pressure range: 86.0 Kpa ~ 106.0 Kpa
Working modes:
Pure cut: 5w ~ 100w (Load:300Ω)
Blend cut: 5w ~ 50w (Load:300Ω)
Forced coagulation: 5w ~ 80w (Load:500Ω)
Soft coagulation: 5w ~ 50w (Load:500Ω)
Technology data:
Voltage: 230V±10V, 50Hz
Working frequency: 330KHz ~ 460KHz
Leakage currents to ground: Less than 0.5mA
Leakage currents to patient: Less than 0.01mA
Experts have identified harmful smoke which contains a variety of toxic gases and vapors will occur during electrosurgical operation. Medical staff and patients exposure to the smoke in large may cause viral contamination,respiratory problems,nausea and burning eyes.To use a smoke evacuation system is the most effective way of protecting operating room staff and patients from hazards.
 
Features
  • Effective smoke removal: Captures toxic gases and vapors.
  • Compact and portable: Weighs 3.5 kg with a trolley cart for easy mobility.
  • Quiet operation: Works at 55 dB.
  • High efficiency: Processes 3.5-4.2 cubic meters of smoke per hour.
  • Automatic startup: Can be activated by an internal sensor or foot switch
WeightN/AN/AN/AN/AN/AN/A
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • Rating
  • Price
  • Description
Click outside to hide the comparison bar