Ultrasonic Vascular Doppler Detector Bi
Ask for Price$0.00
Shipped From Abroad
Feature:
620VP TFT LCD displays the wave of the instant blood flow average velocity and strength. It prints the monitoring blood flow curve simultaneously;
Detect the blood stream status of arterial/venous by 8MHz probe;
Detect the blood flow average velocity, detect the result of fingers/toes and part of body’s vein anatomies operation;
BV-620VP(TFT) portable bidirectional vascular Doppler with large color LCD screen;
Built-in ARM microprocessor & real-time displays blood flow velocity waveform;
Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Description
Feature:
620VP TFT LCD displays the wave of the instant blood flow average velocity and strength. It prints the monitoring blood flow curve simultaneously;
Detect the blood stream status of arterial/venous by 8MHz probe;
Detect the blood flow average velocity, detect the result of fingers/toes and part of body’s vein anatomies operation;
BV-620VP(TFT) portable bidirectional vascular Doppler with large color LCD screen;
Built-in ARM microprocessor & real-time displays blood flow velocity waveform;
Can store 50 detected waveforms;
High-speed USB/RS -232 port, can be connected directly to computer to analyze, store, and print the waveform data;
Detect peak and average blood speed
Detect blood flow of peripheral vessel
Detect subsection systolic pressure
Detect phlebostenosis, vein occlusions
Detect Systolic pressure of toes and fingers
Detect blood speed during recovery
Detect the pulse rate and show PR simultaneously
Specification:
Frequency range:Main unit:200±80~5000±1000HZ
Probe:350±80~2500±500HZ
External output:loudspeaker, single channel with earphone jack
Emissive waveform: sine wave
Ultrasonic frequency:5.0MHz±10% 、8.0MHz ±10%
Ultrasonic frequency average intensity: < 50mW/cm2
Velocity measure range:0~100 cm /s.
Test error:≤20%(relative error)
Overall sensitivity:> 100dB
Printing speed:40cm/min,60cm/min ,display synchronize with print
Frequency mode display range:0.2 KHz~7.0 KHz
LCD Display:128 X 64 dots, LCD cursor indicates blood stream speed, double display mode for the spectrum and velocity.
Power indication: blue LED indication
Charge indication: the charge indicator is yellow when charging and become green after full charge
Alarm indication: the indicator light is red when the lack of battery
Lack of paper indication: When the recorder is lack of paper, the indication light is red
Outline dimension:210*220*105 (mm)
Net weight:1.9 Kg
Environment condition:
Temperature:+5℃ ~ +40℃ ,
Humidity:<80%,
Atmospheric pressure:86kPa ~ 106kPa.
Transport and storage environment:
Temperature:-10℃ ~ +55℃ ,
Humidity:<80%,
Atmospheric pressure:86kPa ~ 106kPa
Quick Comparison
Ultrasonic Vascular Doppler Detector Bi remove | Feeding Table remove | Wash Hand Bowl with Stand remove | Syringe Needle Destroyer remove | Instrument Tray remove | Siare Morpheus M Anaesthetic Machine remove | |||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Name | Ultrasonic Vascular Doppler Detector Bi remove | Feeding Table remove | Wash Hand Bowl with Stand remove | Syringe Needle Destroyer remove | Instrument Tray remove | Siare Morpheus M Anaesthetic Machine remove | ||||||||
Image | ||||||||||||||
SKU | SF103356013038 | SF1033560084-195 | SF1033560084-246 | SF1033560084-206 | SF1033560084-199 | SF1033560101-2 | ||||||||
Rating | ||||||||||||||
Price | Ask for Price | $31.50 | $36.00 | $157.00 | $6.90 | Ask for Price | ||||||||
Stock | ||||||||||||||
Availability | ||||||||||||||
Add to cart | ||||||||||||||
Description | Shipped From Abroad
Feature:
620VP TFT LCD displays the wave of the instant blood flow average velocity and strength. It prints the monitoring blood flow curve simultaneously;
Detect the blood stream status of arterial/venous by 8MHz probe;
Detect the blood flow average velocity, detect the result of fingers/toes and part of body's vein anatomies operation;
BV-620VP(TFT) portable bidirectional vascular Doppler with large color LCD screen;
Built-in ARM microprocessor & real-time displays blood flow velocity waveform;
Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| In stock
| In stock
| In stock
Needle destruction destroy the needle immediately following its use. Needle destruction are an absolute necessity in developing parts of the world to prevent the reuse of needles and the spread of bloodborne pathogens. They are NOT a good alternative, however, for hospital use in the developed parts of the world. Needle destruction are products that bend, cut, or destroy the needle. This are distinctly different from needle destroyer that send an arc of electricity to vaporize and melt the needle.
| In stock
| Shipped from Abroad The MORPHEUS M is an anaesthesia machine and it can be used on adult, children and newborn patients. The MORPHEUS M is suitable for administration of Oxygen – Air – Nitrous Oxide – Halothane – Enflurane – Isoflurane – Sevoflurane – Desflurane mixtures. Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | ||||||||
Content | Feature: 620VP TFT LCD displays the wave of the instant blood flow average velocity and strength. It prints the monitoring blood flow curve simultaneously; Detect the blood stream status of arterial/venous by 8MHz probe; Detect the blood flow average velocity, detect the result of fingers/toes and part of body's vein anatomies operation; BV-620VP(TFT) portable bidirectional vascular Doppler with large color LCD screen; Built-in ARM microprocessor & real-time displays blood flow velocity waveform; Can store 50 detected waveforms; High-speed USB/RS -232 port, can be connected directly to computer to analyze, store, and print the waveform data; Detect peak and average blood speed Detect blood flow of peripheral vessel Detect subsection systolic pressure Detect phlebostenosis, vein occlusions Detect Systolic pressure of toes and fingers Detect blood speed during recovery Detect the pulse rate and show PR simultaneously Specification: Frequency range:Main unit:200±80~5000±1000HZ Probe:350±80~2500±500HZ External output:loudspeaker, single channel with earphone jack Emissive waveform: sine wave Ultrasonic frequency:5.0MHz±10% 、8.0MHz ±10% Ultrasonic frequency average intensity: < 50mW/cm2 Velocity measure range:0~100 cm /s. Test error:≤20%(relative error) Overall sensitivity:> 100dB Printing speed:40cm/min,60cm/min ,display synchronize with print Frequency mode display range:0.2 KHz~7.0 KHz LCD Display:128 X 64 dots, LCD cursor indicates blood stream speed, double display mode for the spectrum and velocity. Power indication: blue LED indication Charge indication: the charge indicator is yellow when charging and become green after full charge Alarm indication: the indicator light is red when the lack of battery Lack of paper indication: When the recorder is lack of paper, the indication light is red Outline dimension:210*220*105 (mm) Net weight:1.9 Kg Environment condition: Temperature:+5℃ ~ +40℃ , Humidity:<80%, Atmospheric pressure:86kPa ~ 106kPa. Transport and storage environment: Temperature:-10℃ ~ +55℃ , Humidity:<80%, Atmospheric pressure:86kPa ~ 106kPa |
|
| Needle destruction destroys the needle immediately following its use. Needle destruction are an absolute necessity in developing parts of the world to prevent the reuse of needles and the spread of bloodborne pathogens. They are NOT a good alternative, however, for hospital use in the developed parts of the world. Needle destruction are products that bend, cut, or destroy the needle. This are distinctly different from needle destroyer that send an arc of electricity to vaporize and melt the needle.
Features:
|
| The MORPHEUS M is an anaesthesia machine and it can be used on adult, children and newborn patients. The MORPHEUS M is suitable for administration of Oxygen – Air – Nitrous Oxide – Halothane – Enflurane – Isoflurane – Sevoflurane – Desflurane mixtures.
Features:
Click Here To Download Catalogue) | ||||||||
Weight | N/A | N/A | N/A | N/A | N/A | N/A | ||||||||
Dimensions | N/A | N/A | N/A | N/A | N/A | N/A | ||||||||
Additional information |
Reviews
There are no reviews yet.